Technical Data Sheets

Similar documents
Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

Technical data sheets

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 400/500 kw With eboost Technology

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

POWER kva

POWER kva

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

PowerValue 11/31 T kva

EFFEKTA Power Supplies

ConceptpowerTM Modular kVA

PowerScale kva Technical Specifications

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

PowerScale TECHNICAL SPECIFICATIONS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

1.1 GENERAL CHARACTERISTICS

POWERTRONIX QUASAR 5-40 KVA

Industrial PFC UPS System

TECHNICAL SPECIFICATIONS

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Master Plus kva

AME. Rectifier - Battery charger. Industrial applications: Key features:

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Master Plus kva

Master MPS kva kva 3:1 3:3 VFI TYPE

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Master MPS kva kva 3:1 3:3 VFI TYPE

Master DIALOG INDUSTRY RANGE

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Three Phase UPS Systems Range: 10 to 500kVA

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

UPS Multi Sentry 10-20kVA

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

DC POWER SUPPLY SYSTEMS

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

60 to 160 kva.

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

EATON 9315 UPS 200 TO 300 KVA Specifications

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

MASTERYS IP+ 10 to 80 kva

Green Power 2.0 MASTERYS GP

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Liebert. FP 50Z kva

Marketing Management Team of Europe

Aurora Single Phase Emergency Lighting Inverters

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

D Series: UPS UPTO - 300KVA - Three / Three Phase

Industrial Chargers and

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Master MPS kva kva 3:1 3:3 VFI TYPE

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

LIEBERT APM 3-PHASE UPS: 15-90KVA/KW, 60HZ, VAC, SINGLE & DUAL INPUT - SITE PLANNING DATA

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Transcription:

GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01 SGSE250-300S1UPS01 SG-CE Series 160-200 kva PurePulse TM SG-CE Series 250-300 kva PurePulse TM GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 51 44 www.gedigitalenergy.com GE imagination at work

GENERAL DATA Topology VFI, double conversion with integrated transformer Nominal output power from PF=0.6 lag. to 0.9 leading KVA/kW 160/144 200/180 250/225 300/270 Overall efficiency at 100% load in VFI mode % 91.8 92.2 92.0 92.3 Overall efficiency at 75% load in VFI mode (guaranteed 92.1 92.8 92.4 92.9 Overall efficiency at 50% load in VFI mode values) 92.1 92.9 92.7 93.2 Overall efficiency at 100% load in SEM mode % 98.2 98.4 98.4 98.5 Heat dissipation at 100% load in VFI mode, PF=0.8 lag. & charged battery kw 11.44 13.54 17.40 20.02 Cooling air (25 C 30 C) m 3 /h 3340 3950 5080 5840 Audible noise level db(a) 69 69 69 69 Battery type Valve regulated lead-acid (VRLA), vented lead-acid, NiCd Operating temperature range UPS: 0 C 40 C Storage temperature range -25 C +55 C Relative Humidity Max. 95% (non-condensing) Max. altitude without power derating 1000m Power derating (according to IEC 62040-3) 1500m: -5% / 2000m: -9% / 2500m: -14% / 3000m: -18% Protection degree IP 20 (IEC 60529) s IEC 62040, CE marking EMC IEC 62040-2 (Category C2 as option) Electrostatic discharge immunity 4kV contact / 8kV air discharge Internal protection All live parts shrouded Transport Cabinet suitable for handling by forklift Colour RAL 9003 (white) Installation Can be positioned against a wall and floor fixed Service access Front and top access only External cable connections Bottom at front of the cabinet (top as option) Cooling Enforced ventilation with fan failure detection Paralleling (RPA version) Up to 6 units parallelable for redundancy or capacity in RPA configuration (optional). RECTIFIER Rectifier bridge Three phase, IGBT rectifier, PurePulse TM technology, overtemperature protection input voltage Nominal: 3 x 380V / 400V / 415V + N Rectifier accepted ph-ph voltage range: 340V 460V Other input voltages On request Input frequency 50/60 Hz +/-10% (45-66 Hz) Power factor 0.99 Input current THD <4% from 60% to 100% load / <5% from 25% to 50% load Inrush current Limited by soft-start circuit Power walk-in 15 seconds Output voltage tolerance +/- 1% DC voltage ripple <1% DC current ripple Max. 5% the battery capacity [Ah], expressed in A Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Programmable Input power data kva 160 200 250 300 Input power at inverter nominal load and charged battery at PF=0.8 lag. 139.5 173.6 217.4 260.1 kw at PF=0.9 lag. 156.9 195.3 244.6 292.6 Max. input power at inverter nominal load and max. battery recharge current (programmable) kw 174.8 217.2 271.4 326.6 Max. battery charging current (programmable) at at PF=0.8 lag. 85 105 130 160 A the beginning of battery recharge at nominal load at PF=0.9 lag. 40 50 70 80 UPS OUTPUT POWER CAPABILITY Output UPS power versus power factor for: Inductive loads Resistive loads Capacitive loads Modifications reserved Page 2/5

BATTERY Battery type Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd Float voltage at 20 C 400V 436V (dependent on the number of cells) VRLA at 2.27V/cell: 177 192 cells Vented lead acid at 2.23V/cell, no boostcharge: 180 195 cells Number of cells Vented lead acid at 2.23V/cell, with boostcharge at 2.35 V/cell: 180 185 cells NiCd at 1.41V/cell, no boostcharge: 284 309 cells NiCd at 1.41V/cell, with boostcharge at 1.55 V/cell: 281 cells Min. discharge voltage (programmable) Up to 310V (dependent on the number of cells) Recharge time <5 hours up to 90% of battery capacity Battery to earth fault detection Automatic and manual battery test Automatic battery contactor Battery power data kva 160 200 250 300 DC power at full load and PF=0.8 lag. kw 135.2 168.3 210.8 252.1 DC power at full load and PF=0.9 lag. kw 152.1 189.3 237.1 283.6 DC power at full typical computer load (PF=0.66 lag.) kw 111.5 138.8 173.9 208.0 Matching battery cabinets See optional features on page 4 INVERTER Nominal output power at PF=0.6... 0.9 lag. 160 200 250-300 kva Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge SVM (Space Vector Modulation) and IGBT technology Output transformer (for galvanic separation) Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 3% - dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 5 ms - output voltage THD for 100% linear load... Max. 1.5% - output voltage THD for 100% non-linear load (EN 50091) Max. 3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 3% Overload capability (at 25 C ambient temperature) 125% - 10 minutes, 150% - 1 minute Short-circuit characteristic Electronic short-circuit protection, current limit to 2.2 times In for 200 ms MTCB clearance capability (selectivity) 20% In within 5-10ms (with MTCB class C or magn. trip at max 10In) Crest factor >3:1 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass Separate (dual input-recommended) or common to the rectifier input - Static switch (SCR) on bypass - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass +/- 10% (adjustable) 200% for 5 minutes & 45 times In for 10 ms, non repetitive INTERFACING 6 programmable signalling voltage-free contacts - information for easy integration and signalling (available on Delta and block terminals) - 27 user settable signals Serial channel RS232 (on Delta 9 pin connector) - EMERGENCY POWER OFF (n/c contact, customer supplied) Input signals - GEN ON (emergency power supply ON, n/o contact, customer supplied) - 1 auxiliary signal, with settable functionality Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 3/5

SGSE160-300OPTB1 cabinet01 SGSE160-300OPTB2 cabinet01 FRONT PANEL CONTROLS, SIGNALS AND ALARMS SYNOPTIC DIAGRAM OF THE UPS: Represents the operational status with integrated LEDs and power flow indicators. SERVICE CHECK: Turns on when maintenance is due or when the UPS is Service mode. ALARM: Visual (LED) and audible signal (buzzer), active when an alarm condition is present. STOP OPERATION: Visual (LED) and audible signal (buzzer) active approx. 3 minutes before complete and automatic load disconnection (due to an overtemperature condition or fully discharged battery). LOAD LEVEL, BATTERY AUTONOMY: Status indicator bar graphs. PUSH-BUTTONS: - INVERTER ON - MUTE - INVERTER OFF - LAMP TEST - TOTAL OFF (key with protective cover): to be pressed for emergency off. MONITORING SYSTEM with multi language LCD display and control keys. OPTIONS COMMUNICATION: 1. Additional Customer Interface Card 2. Advanced SNMP Card 2. GE Power Diagnostics 3. GE Data Protection 4. RSB - Remote Signalling Box (cable for connection to UPS not included) BUILT-IN UPS OPTIONS: 1. RPA kit 2. Auxiliary Power Supply (APS) 24VDC 3. Surge suppressors OPTIONS IN ADDITIONAL CABINETS: Dimensions (WxDxH): 500x850x1900mm 850x850x1900mm 1000x850x1900mm 1500x850x1900mm 1. Rectifier or bypass or UPS input transformer 160 & 200 kva / 250 & 300 kva 2. EMC filter IEC 62040-2 Category C2 (Class A) 3. Top entry cables cabinet 4. Special voltages: input and/or output On request 5. Empty battery cabinets 6. Battery cabinet 2x50Ah (without fuses) BATTERY TABLE 7. Battery cabinet 2x75Ah (without fuses) At 75% load PF 0.8 At 100% load PF 0.8 UPS 2x50Ah 1170 Kg 2x75Ah 1800 Kg 2x50Ah 2x75Ah 4x50Ah 4x75Ah 2x50Ah 2x75Ah 4x50Ah 4x75Ah 160 9 min. 15 min. 22 min. 36 min. 6 min. 11 min. 16 min. 25 min. 200 6 min. 12 min. 17 min. 27 min. 8 min. 12 min. 19 min. 250 8 min. 13 min. 21 min. 6 min. 8 min. 15 min. 300 10 min. 17 min. 6 min. 12 min. These runtimes can be achieved only with our High Rate batteries EXTERNAL ACCESSORIES: 1. ISM - Intelligent Synchronization Module 350mm x 190mm x 584mm 2. Parallel output cabinet with centralized maintenance bypass On request 3. Battery fuses box On request Modifications reserved Page 4/5

TECHNICAL DATA SG-CE Series 160 & 200 kva SGSE160-200S1UPS dimension01 UPS cabinet WEIGHTS (kg) Additional cabinet SG-CE Series 250 & 300 kva SGSE250-300S1UPS dimension01 1'900mm UPS Rating (kva) UPS standard (kg) Floor loading UPS standard (kg/m 2 ) Rectifier or bypass transformer (1000x850x1900mm) EMC filters IEC 62040-Cat. C2 (500x850x1900mm) Top entry cables cabinet (500x850x1900mm) 1'900mm 160 1225 1068 800 230 125 200 1315 1146 800 230 125 850mm 1'350mm 250 1675 1314 900 230 125 850mm 1'500mm Dimensions (WxDxH): 1350mm x 850mm x 1900mm 300 1775 1393 900 230 125 Note: Single weights have to be added up for system configuration to get the total weight! Dimensions (WxDxH): 1500mm x 850mm x 1900mm UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass 1 = Rectifier 3 = Electronic Bypass 5 = Mains 7 = External Battery 2 = Inverter 4 = Manual Bypass 6 = Load F4 = External Battery Fuses Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Protections and cable sections Cable sections A, B, C, D, E and K Recommended by European s Alternatively, local standards to be respected kva Fuses AgL or equivalent MTCB Cable sections (mm 2 ) F1 F2 F3 F4 A B C & E & D K 160 3x250A 3x250A 3x250A 2x400A 3x120+70 4x120 4x120+70 2x240+120 200 3x315A 3x315A 3x315A 2x500A 3x150+95 4x150 4x150+95 2x(2x120)+120 250 3x400A 3x400A 3x400A 2x630A 3x240+120 4x240 4x240+120 2x(2x150)+150 300 3x500A 3x500A 3x500A 2x800A 3x(2x120)+120 4x(2x120) 4x(2x120)+120 2x(2x240)+240 SEV / ASE cable sections recommended in Switzerland (mm 2 ) F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer kva A B C & E & D K K: supplied by GE only with battery 160 3x150+95 4x150 4x150+95 2x(2x95)+95 F4: can be supplied by GE. 200 3x185+95 4x185 4x185+95 2x(2x150)+150 250 3x(2x95)+95 4x(2x95) 4x(2x95)+95 2x(2x185)+185 300 3x(2x150)+150 4x(2x150) 4x(2x150)+150 2x(3x185)+2x150 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Modifications reserved Page 5/5 Technical Data Sheets SG Series 160-300 kva