Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Similar documents
Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 400/500 kw With eboost Technology

Technical data sheets

TLE Series UPS 160/200/225/250 kw with eboost Technology

TLE Series UPS 750/1000 kw With eboost Technology

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical data sheets

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

POWER kva

POWER kva

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

PowerValue 11/31 T kva

EFFEKTA Power Supplies

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

ConceptpowerTM Modular kVA

1.1 GENERAL CHARACTERISTICS

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

PowerScale TECHNICAL SPECIFICATIONS

PowerScale kva Technical Specifications

Master Plus kva

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

POWERTRONIX QUASAR 5-40 KVA

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Master Plus kva

AME. Rectifier - Battery charger. Industrial applications: Key features:

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Industrial PFC UPS System

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

TECHNICAL SPECIFICATIONS

MASTERYS IP+ 10 to 80 kva

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

Three Phase UPS Systems Range: 10 to 500kVA

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

Marketing Management Team of Europe

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

UPS Multi Sentry 10-20kVA

Liebert. FP 50Z kva

Green Power 2.0 MASTERYS GP

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

Master DIALOG INDUSTRY RANGE

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

DC POWER SUPPLY SYSTEMS

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

60 to 160 kva.

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

SG Series 225 & 300. GE Digital Energy Power Quality. User Manual. imagination at work. Uninterruptible Power supply. 225 & 300 kva / 480Vac UL / S2

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

D Series: UPS UPTO - 300KVA - Three / Three Phase

Power+ CLASSIC. 20/30 kva, 3x208 Vac

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Illuminator Series CR NEMA 3R

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

EATON 9315 UPS 200 TO 300 KVA Specifications

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

Master MPS kva kva 3:1 3:3 VFI TYPE

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

Transcription:

Technical Data Sheet Uninterruptible Power Supply TM SG Series 200-250 - 300 PurePulse CE S3 TM SG Series 160 PurePulse CE S3 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com g imagination at work

Model: Issued by: Approved by: SG Series 160 200 250-300 PurePulse CE S3 Product Document Department Riazzino - CH R & D Department Riazzino - CH Date of issue: 20.04.2013 File name: GE_UPS_TDS_SGS_PCE_M16_M30_3GB_V020 Revision: 2.0 Identification No.: Up-dating Revision Concern Date 2.0 ECN 1825: Start-Up key & Update template 20.04.2013 COPYRIGHT 2013 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE s Critical Power. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6

GENERAL DATA Topology VFI, double conversion with integrated transformer Nominal output apparent power from PF=0.6 lag. to 0.9 lag. and at 0.9 leading KVA 160 200 250 300 Nominal output active power from PF=0.9 lag. to 0.9 leading kw 144 180 225 270 Efficiency at 100% load PF=1 in VFI / eboost Operation Modes 93.6/98.4 93.7/98.4 93.4/98.4 93.5/98.5 Efficiency at 75% load PF=1 in VFI / eboost Operation Modes % 93.9/98.3 94.3/98.3 94.0/98.3 94.0/98.5 Efficiency at 50% load PF=1 in VFI / eboost Operation Modes 94.2/98.1 94.6/98.1 94.1/98.1 94.2/98.3 Heat dissipation at 100% load, PF=0.8 lag. & charged battery (VFI) kw 8.2 10.1 13.2 15.6 Heat dissipation at 100% load, PF=0.9 lag. & charged battery (VFI) kw 9.2 11.3 14.9 17.6 Cooling air at PF=0.8 (25 C 30 C) m 3 /h 2389 2940 3850 4550 Cooling air at PF=0.9 (25 C 30 C) m 3 /h 2688 3308 4331 5119 Audible noise level db(a) 69 Battery type Valve regulated lead-acid (VRLA), vented lead-acid, NiCd Operating temperature range UPS: 0 C 40 C Storage temperature range UPS: -25 C +55 C Battery: -20 C +40 C (higher the temperature, shorter the storage time of the battery) Relative Humidity Max. 95% (non-condensing) Max. altitude without power derating 1000m Power derating (according to EN/IEC 62040-3) 1500m: -2.5% / 2000m: -5% / 2500m: -7.5% / 3000m: -10% Protection degree IP 20 (IEC 60529 s EN/IEC 62040, CE marking EMC (Electromagnetic Compatibility) EN/IEC 62040-2 (Category C2 as option) Electrostatic discharge immunity 4kV contact / 8kV air discharge Internal protection All internal live parts shrouded Transport Cabinet suitable for handling by forklift Colour RAL 9005 (black) Installation Can be positioned against a wall and floor fixed Service access Front and top access only External cable connections Bottom at front of the cabinet (top as option) Cooling Enforced ventilation with fan failure detection and fan speed regulation Paralleling (RPA version) Up to 6 units for redundancy or capacity in RPA configuration (option) RECTIFIER Rectifier bridge Three phase, IGBT rectifier, PurePulse technology, overtemperature protection input voltage Nominal: 3 x 400V + N Programmable: 3 x 380 / 415V + N Rectifier accepted ph-ph voltage range: 340V 460V Other input voltages On request Input frequency 50/60 Hz +/-10% (45 66 Hz) Power factor 0.99 Input current THD 2% at 100% load <2.5% at 75% load <3% at 50% load Inrush current Limited by soft-start circuit Power walk-in 15 seconds Output voltage tolerance +/- 1% DC voltage ripple <1% DC current ripple Max. 5% the battery capacity [Ah], expressed in A Battery charging characteristic IU (DIN 41773), T compensated floating voltage Battery charging current limit Programmable Input power data kva 160 200 250 300 Input power at inverter nominal load and charged battery at PF=0.8 lag. 136.8 170.8 214.1 256.7 kw at PF=0.9 lag. 153.9 192.1 240.9 288.8 Max. input power at inverter nominal load and max. battery recharge current (programmable) kw 170.5 212.7 267.8 321.1 Max. battery charging current (programmable) at at PF=0.8 lag. 85 105 130 160 A the beginning of battery recharge at nominal load at PF=0.9 lag. 40 50 70 80 UPS OUTPUT POWER CAPABILITY Output UPS power versus power factor for: Inductive loads Resistive loads Capacitive loads Modifications reserved Page 3/6

BATTERY Battery type Valve regulated lead-acid (VRLA)-standard, Vented lead-acid, wet battery and NiCd Float voltage at 20 C 400V 436V (dependent on the number of cells) VRLA at 2.27V/cell: 177 192 cells Vented lead acid at 2.23V/cell, no boostcharge: 180 195 cells Number of cells Vented lead acid at 2.23V/cell, with boostcharge at 2.35 V/cell: 180 185 cells NiCd at 1.41V/cell, no boostcharge: 284 309 cells NiCd at 1.41V/cell, with boostcharge at 1.55 V/cell: 281 cells Min. discharge voltage (programmable) Up to 310V (dependent on the number of cells) Recharge time <5 hours up to 90% of battery capacity Battery to earth fault detection Automatic and manual battery test Battery power data kva 160 200 250 300 DC power at full load and PF=0.8 lag. / PF=0.9 lag. kw 134.7 / 151.6 168.4 / 189.5 210.5 / 236.8 252.6 / 284.2 DC power at full typical computer load (PF=0.66 lag.) kw 111.2 138.9 173.7 208.4 Matching battery cabinets See option features on page 5 INVERTER Nominal output apparent power from PF=0.6 lag. to 0.9 lag. & at 0.9 leading 160 200 250-300 kva Nominal output voltage (on site programmable) 3 x 380V / 400V / 415V + N Inverter bridge SVM (Space Vector Modulation) and IGBT technology Output transformer (for galvanic separation) Output waveform Sine wave Output voltage tolerance: - static... +/- 1% - dynamic (at load step 0 100 0%)... +/- 3% - dynamic (at load step 0 50 0%)... +/- 2% - recovery time to +/-1%... 5 ms - output voltage THD for 100% linear load... Max. 1.5% - output voltage THD for 100% non-linear load (EN 62040) Max. 3% Output voltage tolerance at 100% unbalanced load (Ph-N) +/- 3% Output frequency 50/60 Hz (selectable) Output frequency tolerance: - free-running... +/- 0.1% - with mains synchronisation adjustable to... +/- 4% Phase displacement: - at 100% balanced load... 120 : +/- 1% - at 100% unbalanced load... 120 : +/- 3% Overload capability (at 25 C ambient temperature) 125% - 10 minutes, 150% - 1 minute Electronic short-circuit protection, current limit to: Short-circuit characteristic 2.7 times In for 200 ms between phase and phase 4.0 times In for 200 ms between phase and N/PE MCCB clearance capability (selectivity) 20% In within 5-10ms (with MCCB class C or magn. trip at max. 10In) Crest factor >3:1 eboost OPERATION MODE (OPTION) eboost Operation Mode Output waveform Continuously monitored characteristics (option) Inverter reaction time ms <2 (typical) Steady-State RMS tolerance Vrms +/- 10 Transfer limits in Instantaneous voltage distortion Magnitude Vp +/- 50 eboost Operation Mode (w.r.t. normal sine wave) Duration us 500 (option) Steady-State frequency tolerance Hz +/- 3 Instantaneous phase shift rad 0.15 BYPASS Input connection Primary components Voltage limits for inverter/bypass load transfers Overload on bypass Separate for rectifier and bypass input or common to the rectifier input (option) - Static switch (SCR) on bypass - Electromechanic contactors (backfeed protection) on bypass and inverter - 2 manual switches for maintenance bypass +/- 10% (adjustable) 150% for 1 minute & 45 times In for 10 ms, non repetitive INTERFACING RS232 serial port EPO - EMERGENCY POWER OFF (n/c contact, customer supplied) Customer Interface board 6 programmable signalling voltage-free contacts... (available on block terminals) Connector RJ45... Input signals... Note: all indicated values are typical. Variations may be found from one unit to another. Modifications reserved Page 4/6 - information for easy integration and signalling - 27 user settable signals With adaptation cable for a serial port RS232 / sub DB9 connection - GEN ON (emergency power supply ON, n/o contact, customer supplied) - 1 auxiliary signal, with settable functionality

SGSE_160-300_OPT_B1 cabinet_01 SGSE_160-300_OPT_B2 cabinet_01 Critical Power FRONT PANEL CONTROLS, SIGNALS AND ALARMS The control panel, positioned on the UPS front door, acts as the UPS user interface and comprises of the following elements: Back lit Graphic Display (LCD) with the following characteristics: Multilanguage communication interface: English, German, Italian, Spanish, French, Finnish, Polish, Portuguese, Czech, Slovakian, Chinese, Swedish, Russian and Dutch; Graphic diagram indicating UPS status. Command keys and parameters setting. UPS status control LED. OPTIONS COMMUNICATION: 1. Additional Customer Interface Card 2. 3-ph SNMP/WEB plug-in Adapter 3. GE iupsguard 4. GE Data Protection 5. RSB - Remote Signalling Box (cable for connection to UPS not included) BUILT-IN UPS OPTIONS: 1. eboost Operation Mode 2. RPA kit (Redundant Parallel Architecture) 3. Kit for common input mains 4. Auxiliary Power Supply (APS) 24VDC 5. Surge suppressors OPTIONS IN ADDITIONAL CABINETS: Dimensions (WxDxH): 500x850x1900mm 850x850x1900mm 1000x850x1900mm 1500x850x1900mm 1. Rectifier or bypass or UPS input transformer 160 & 200 kva / 250 & 300 kva 2. EMC filter EN/IEC 62040-2 Category C2 (Class A) 3. Top entry cables cabinet 4. Special voltages: input and/or output On request 5. Empty battery cabinets 6. Battery cabinet 2x50Ah (without fuses) BATTERY TABLE 7. Battery cabinet 2x75Ah (without fuses) UPS At 75% load PF 0.8 At 100% load PF 0.8 2x50Ah 1170 Kg 2x75Ah 1800 Kg 2x50Ah 2x75Ah 4x50Ah 4x75Ah 2x50Ah 2x75Ah 4x50Ah 4x75Ah 160 9 min. 15 min. 22 min. 36 min. 6 min. 11 min. 16 min. 25 min. 200 6 min. 12 min. 17 min. 27 min. _ 8 min. 12 min. 19 min. 250 _ 8 min. 13 min. 21 min. _ 6 min. 8 min. 15 min. 300 10 min. 17 min. 6 min. 12 min. These runtimes can be achieved only with our High Rate batteries EXTERNAL ACCESSORIES: 1. Parallel output cabinet with centralized maintenance bypass On request 2. Battery fuses box On request Modifications reserved Page 5/6

1'900mm UPS Rating (kva) UPS standard (kg) Floor loading UPS standard (kg/m 2 ) eboost Operation Mode (kg) Rectifier or bypass transformer (850/1000x850x1900mm) EMC filter EN/IEC 62040-Cat. C2 (500x850x1900mm) Top entry cables cabinet (500x850x1900mm) 1'900mm Critical Power TECHNICAL DATA SG Series 160 PurePulse WEIGHTS (kg) SG Series 200-250 - 300 PurePulse SGSE_160_S3_UPS dimension_01 UPS cabinet Built-in UPS options Options in additional cabinet SGSE_200-300_S3_UPS dimension_01 160 1050 1373 20 800 230 125 200 1220 1105 800 230 125 850mm 900mm 250 1470 1331 30 900 230 125 850mm 1'300mm Dimensions (WxDxH): 900mm x 850mm x 1900mm 300 1560 1412 900 230 125 Note: Single weights have to be added up for system configuration to get the total weight! Dimensions (WxDxH): 1300mm x 850mm x 1900mm UPS BLOCK DIAGRAM, PROTECTIONS AND CABLE SECTIONS Common input Rectifier & Bypass Separated input Rectifier & Bypass 1 = Rectifier 3 = Automatic Bypass 5 = Mains 7 = External Battery 2 = Inverter 4 = Manual Bypass 6 = Load F4 = External Battery Fuses Protections and cable sections Protections for mains voltages 3x380/220V, 3x400/230V, 3x415/240V Cable sections recommended by European s Alternatively, local standards to be respected kva Fuses AgL or equivalent MCCB Cable sections (mm 2 ) F1 F2 F3 F4 A B C & E & D K 160 3x250A 3x250A 3x250A 2x400A 3x120+70 4x120 4x120+70 2x240+120 200 3x315A 3x315A 3x315A 2x500A 3x150+95 4x150 4x150+95 2x(2x120)+120 250 3x400A 3x400A 3x400A 2x630A 3x240+120 4x240 4x240+120 2x(2x150)+150 300 3x500A 3x500A 3x500A 2x800A 3x(2x120)+120 4x(2x120) 4x(2x120)+120 2x(2x240)+240 Cable sections recommended in Switzerland (mm 2 ) F1, F2, F3, F4, A, B, C, D, E, (K): supplied by customer kva A B C & E & D K K: supplied by GE s Critical Power only with battery 160 3x150+95 4x150 4x150+95 2x(2x95)+95 F4 and Q3: can be supplied by GE s Critical Power 200 3x185+95 4x185 4x185+95 2x(2x150)+150 250 3x(2x95)+95 4x(2x95) 4x(2x95)+95 2x(2x185)+185 300 3x(2x150)+150 4x(2x150) 4x(2x150)+150 2x(3x185)+2x150 IMPORTANT NOTE! The UPS is designed for TN System. The input neutral shall be grounded at source and shall never be disconnected. 4 pole breaker shall not be used at the UPS input (see also IEC 60634, IEC 61140, IEC 61557). Modifications reserved Page 6/6