AC/DC Arc Furnace and Ladle Furnace Transformers

Similar documents
Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Cast resin transformers

Medium Voltage. KOFD Indoor Type Current Transformers Cast Resin Insulated. Catalogue. 12, 13.8, 17.5, 24 and 36 kv KOFD 1 GB

Benefits, typical uses

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

Power IT RESIBLOC Dry Type Distribution Transformers. 250 kva up to 40,000 kva

On-Load Tap changer Type V

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

TECHNICAL SPECIFICATIONS

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

PowerIT Indoor Voltage Transformer Fuses, WBP. Outdoor Voltage Transformer Fuses, BRT. Catalogue 1YMB en. Industrial IT.

Minera. Oil distribution transformers up to kva. eco design. Minera at a glance. Standards

High Voltage Technology & Testing

OLIVER ONLINE VOLTAGE REGULATION

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

TRANSFORMERS UP TO 750 kv

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

132/11 kv, 25 MVA MOBILE SUBSTATION

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

Transformer bushings, type GOH. Technical guide

Indoor switches for railway lines. single-pole design rated voltage up to 27,5 kv rated current up to 4000 A

DAQO Technical Differences of Isolated Phase Bus Standards. Study of Design Standard Variances, Insulator Design and Shipping Section Design

CAST RESIN DISTRIBUTION TRANSFORMERS 2017 EDITION

NXPLUS C Single busbar. Maintenance-free for lifetime

Vacuum Generator Circuit Breaker - A trend-setting power plant technology

Medium Voltage Metal-Enclosed Switches

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Vacuum Circuit Breaker VS1

CONTENTS About the company 1. Low-voltage arresters LVA type 2. Metal-oxide surge arresters for distribution systems. 3.

CAST RESIN TRANSFORMERS

3TM Vacuum Contactors

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

EMPAC Metal enclosed capacitor bank for wind applications

Transformer Technology Seminar HV Collector (Power) Transformers

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

HARMONIC FILTER REACTOR

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

LV Capacitor CLMD03 Power Module Instruction manual

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Combined Current and Voltage Instrument Transformer CVS-P-24-O Technical Specifications

HPS EnduraCoil. Cast Resin Transformer

3EK7 Medium Voltage Silicone Insulated Surge Arresters


UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Transformers for Power Applications

Independent Testing Laboratory for High Voltage Equipment

Small wonder. Station service voltage transformers for small power requirements

TRANSFORMER RECTIFIER

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

MESSKO MTraB product line (see application table page 3) MESSKO MTraB connection requirements

FUSES. Safety through quality

Our Global Solutions CAPABILITIES

Make : BHEL / Siemens Type : THDF 115/ Reference Standard : IEC 60034

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

Medium Voltage Metal-Enclosed Switches

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

ELECTRICAL MATERIAL SUPPLY

High-voltage high-breaking capacity VV fuse-links

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

Thermal Overcurrent Circuit Breaker 3120-F...

Solenoid coil for control in potentially explosive areas Type BZ

High Performance Thermal Circuit Breaker

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

Power & Distribution Transformers

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Thermal Overcurrent Circuit Breaker 3120-F...

Tamini is the leading Italian company in the world for the design and production of industrial, power and special transformers.

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

Thermal-Magnetic Circuit Breaker M1-...

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Power Supplies. 11/2 Introduction

Power and Distribution Transformers

Power Voltage Transformers for Air Insulated Substations

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Gas Insulated Metal-clad Switchgear, HMGS!

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Film Capacitors Power Factor Correction

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Concentrated savings for your applications. Altivar Medium-voltage variable speed drive 0.5 to 10 MW. DIA2ED EN.indd 1 17/07/08 8:58:49

Concentrated savings for your applications. Altivar Medium-voltage variable speed drive 0.5 to 10 MW

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Transcription:

AC/DC Arc Furnace and Ladle Furnace Transformers Specification parameter Specify the requirements for 1. Environmental condition and standards Applicable standard Electrical standard Mechanical standard IEC / IEEE / GOST DIN, EN ISO / ANSI (with metric screw system) Location Indoor / Outdoor / Offshore / Explosion-proof Environment High pollution / Salty and or mist / Tropical / Artic Altitude m 1,000 m Ambient s Yearly average ambient Monthly average ambient Yearly maximum ambient Yearly minimum ambient C 20 C C 30 C C 40 C C -25 C Max. water inlet C 35 C 1

Specify the requirements for 2. Electrical design Design criteria Type Cooling type Oil-immersed 3-phase EAF transformer ODWF Rated power MVA 124 MVA Operating mode Continuous Rated frequency Hz 60 Hz Vector group Dd0 (internally-closed delta) Rated voltage kv 34.5 kv / 0.728 kv Tapping range V 727.8-616.1-348.5 V No. of steps/pos. 17/18 Overexcitation % 10% Rated current HV A 1,339 A Rated current LV ka 63.458 ka (max. 74.97 ka) Short-circuit duration s 2 s Short-circuit power MVA max. 500 MVA Isolation level Highest voltage for equipment HV winding kv 36 kv LV winding kv 1.5 kv Rated power frequency HV winding kv 70 kv LV winding kv 10 kv Rated lightning impulse HV winding kv 200 kv LV winding kv 30 kv Rated switching impulse HV winding kv - LV winding kv - 2

AC/DC Arc Furnace and Ladle Furnace Transformers Voltage table Typical voltage values of AC/DC arc furnace and ladle furnace transformers Position S [MVA] LV phase current LV voltage [V] HV voltage [V] HV voltage [A] [ka] 18 80.00 63.458 728 34,500 1,339 17 80.00 65.600 704 34,500 1,339 16 80.00 67.742 682 34,500 1,339 15 80.00 70.152 658 34,500 1,339 14 80.00 72.562 637 34,500 1,339 13 80.00 74.972 616 34,500 1,339 12 76.19 74.972 587 34,500 1,275 11 72.73 74.972 560 34,500 1,217 10 69.57 74.972 536 34,500 1,164 9 66.67 74.972 513 34,500 1,116 8 63.28 74.972 487 34,500 1,059 7 60.22 74.972 464 34,500 1,008 6 57.44 74.972 442 34,500 961 5 54.50 74.972 420 34,500 912 4 51.85 74.972 399 34,500 868 3 49.45 74.972 381 34,500 828 2 47.26 74.972 364 34,500 791 1 45.25 74.972 348 34,500 757 3

Heavy Duty Rectifier Transformer Specification parameter Specify the requirements for 1. Environmental condition and standards Applicable standard Electrical standard Mechanical standard IEC / IEEE DIN, EN ISO / ANSI (with metric screw system) Location Indoor / Outdoor / Offshore / Explosion-proof Environment High pollution / Salty and or mist / Tropical / Artic Altitude m 1,000 m Ambient s Yearly average ambient Monthly average ambient Yearly maximum ambient Yearly minimum ambient C 12 C C - C 35 C C -20 C Max. water inlet C - 4

Specify the requirements for 2. Electrical design Design criteria Type Cooling type Oil-filled 3-phase rectifier transformer with regulation (auto) transformer with built-in transducers OFAF Rated power MVA 76,368 / 4x 19,092 MVA Operating mode Continuous Rated frequency Hz 50 Hz Vector group Da0 Dy0d1 + 7.5 el / Dy0d1-7.5 el Rated voltage kv 30.0 kv / 4x0.75 kv Tapping range V 750 to 272 V No. of steps/pos. approx. 71/72 (67/68 effective + necessary number of taps/positions for voltage fluctuation) Rated current LV ka 4x 14.697 ka Harmonics specified by Siemens Erlangen Short-circuit duration s 2 s Short-circuit power MVA max. 3,000 MVA Type of rectifier circuit 3-phase bridge or double star Only for double-star transformers: Transducers control range V 20 V Only for double-star transformers: Interphase reactor Rated voltage V 2x 160 V Rated current ka 15,0 ka per LV System Rated frequency Hz 150Hz Isolation level Highest voltage for equipment HV winding kv 36 kv LV windings kv 3 kv Rated power frequency HV winding kv 70 kv LV windings kv 10 kv 5

Specify the requirements for Rated lightning impulse HV winding kv 170 kv LV windings kv - Rated switching impulse HV system - LV system - 6

Converter Trasnformer for Variable speed drives Specification parameter Specify the requirements for 1. Environmental condition and standards Applicable standard Electrical standard Mechanical standard IEC / IEEE / CSA / GOST DIN, EN ISO / ANSI (with metric screw system) Location Indoor / Outdoor / Offshore / Explosion-proof Environment High pollution / Salty and or mist / Tropical / Artic Altitude m 1,000 m Ambient s Yearly average ambient Monthly average ambient Yearly maximum ambient Yearly minimum ambient C 20 C C 30 C C 40 C C -25 C Max. water inlet C - 7

Specify the requirements for 2. Electrical design Design criteria Type Cooling type Oil-immersed, 3-phase double-tier converter transformer with filter winding KFAF Rated power MVA 136.0 / 2x 68 MVA / 50 Mvar Operating mode Continuous Rated frequency Hz 60 Hz ± 5% Vector group D d0 y11 y11 Rated voltage kv 132 kv / 2x 14.1 kv / 17.5 kv Tapping range % 2x (+/- 2.5) % No. of steps +/- 2 Harmonics specified by Siemens PD OM OGD Short-circuit duration s 2 s Short-circuit power MVA max. 500 MVA Isolation level Highest voltage for equipment HV winding kv 138 kv LV1/2 winding kv 15 kv LV winding kv 15 kv Rated power frequency HV winding kv 207 kv LV1/2 winding kv 34 kv LV winding kv 34 kv Rated lightning impulse HV winding kv 550 kv LV1/2 winding kv 110 kv LV winding kv 110 kv Rated switching impulse HV system - LV system - F system - 8