MODEL U801 PTFE Flo-Controller for UHP Liquid Applications. uhp

Similar documents
MODEL 106F TEFLON LIQUID FLOW SENSOR

Ultra Compact UHP Liquid Flow Controllers

NT ELECTRONIC FLOWMETER, MODEL 4400

InVue Electronic Flowmeter, NT4400

NT Flowmeter, Model 4401

Integrated Flow Controller, Model NT6500

LFC Integrated Flow Control Module. Description Malema Sensors

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

Integrated Flow Control Module for Slurries and Chemicals LFC-7000

LFC Integrated Flow Control Module. Description.

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale

PSF50 Paddle flow switch

Type Type 1001 Transducers. I/P & E/P Transducers

MFC Integrated Flow Control Module For Slurries and Chemicals. Key Features. applications.

DPT TARGET TYPE FLOWMETERS

2100 Turbine Flow Sensor

Installation Manual & Operating Instructions

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

Flow Monitors Excess Flow Valves Flow Meters. ChemTec.com

Inline Ultrasonic Flowmeter

Models 415 & 425. Electronic Pressure Regulators. Customer Value Proposition: Contact Information:

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

MPV1 INSTALLATION & MAINTENANCE INSTRUCTIONS

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

Pneutronics. Miniature Proportional Valves. Catalog PND-MPV-001/US January 2007

NT PROPORTIONAL CONTROL VALVE, MODEL 6300

InVue Electronic Flowmeter, Model NT4400

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

RCM - Direct Reading Flowmeters

KDM ARMORED FLOW METER & SWITCH

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

MM1/MM2 INSTALLATION & MAINTENANCE INSTRUCTIONS

Aera FC-7800 Series MFCs. Precise, reliable, metal-sealed design

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

VSO Thermally Compensated Proportional Valve

Miniature Proportional Valve Thermally Compensated Proportional Valve. Physical Properties

Thermal Mass Flow Meter (Analog)

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Electromagnetic Flow Monitor magphant

M Series. Feature rich flow meter and switch with in-line. flow

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Paddle-wheel flow controller for On/Off control

Figure 1: WPR2 Dimensions and Hardware

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

G2 Industrial Grade Meters

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Paddle-wheel flow controller with optical principle for On/Off control

INVUE INTEGRATED FLOW CONTROLLERS, MODELS NT6510, NT6520. User guide

Product Catalog Pressure Regulators. Proportional Valves

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

Mechanical Specifications:

Models SPG5A and SPG6A

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Ultrahigh-Purity Fluoropolymer Diaphragm Valves

TELEDYNE HASTINGS INSTRUMENTS

Paddle-wheel flow controller for On/Off control

Miniature Proportional Valves Precision Fluidics

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps

PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

8000 Series Liquid Flow Meter

ProMinent Beta Solenoid Diaphragm Metering Pumps

Data Sheet. I/P and E/P converters. RS stock numbers ,

E22 Proportional Technology

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

ISTEC MAGNETIC METERS

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Normally Open Miniature Proportional Valve Thermally Compensated Proportional Valve

ELECTRONIC CONTROLLER

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

VORTEX IN-LINE FLOW METERS

EVP SERIES PROPORTIONAL CONTROL VALVES

FLEX-PRO TM PERISTALTIC PUMPS

BULLETIN NO.ELEC IM121/10A Replaces IM121/09A

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Hydro-Flow Model 2300 Installation and Operation Guide B

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

M-50/55 Series. Fixed setting flow switch with in-line flow

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps

LTX RF LEVEL SENSOR. Instruction Manual

Vortex Eggs Delta Flowmeter

KEL DIFFERENTIAL PRESSURE FLOWMETERS

ProMinent delta Solenoid Diaphragm Metering Pumps

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

Miniature I/P, E/P Transducer

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

7000 Series OPTIMASS Mass Flowmeters. Titanium Hastelloy Stainless Steel

Selectable ranges and an LCD are a technician s best friend, that s why we make them standard on every dry media differential pressure sensor!

Transmitters. Differential Pressure Transmitters Pneumatic Design FOXBORO 13A D/P Cell

Installation. Global Vision Inc Jefferson Hwy - Osseo, MN USA - ph fx

Transcription:

PTFE Flo-Controller for UHP Liquid Applications PRELIMINARY Patented* microturbine design provides no zero drift and highly repeatable flow measurement data All high-purity wetted surfaces: PTFE, Kal-Rez, and sapphire only uhp Fully compatible with CMP slurries, acids, solvents, and most other high-purity fluids DESCRIPTION The Model U801 Ultra-High-Purity (UHP) Flo-Controller will precisely measure and control flow rates of virtually any fluid as low as 15 ml/minute or as high as 10 LPM. Repeatable results are achieved by utilizing a patented* microturbine flow sensor design. The system includes both a valve module (shown above) where fluid connections are made and a control module (below) where electrical connections are made. The Model U801 UHP Flo-Controller integrates a proportional double-diaphragm valve to accurately control flow rate. McMillan design* insures long life expectancy under normal operating conditions - millions of cycles with no valve degradation. ±1.0% full-scale accuracy (including linearity & hysteresis) provides the critical control required for modern microelectronic applications. Unparalleled repeatability reassures process engineers that results will be consistent. An optional temperature rating of 0-90 C allows use in most UHP applications. *US Patents 4,467,660; 5,542,302; 5,728,949. Other patents pending. Kal-Rez - Reg TM E.I. dupont de Nemours Co. TABLE OF CONTENTS Principle of operation...2 Detailed specifications...3 Dimensions...4 Ordering information...5 CONTROL MODULE Included with U801. Provides digital display for flow rate and setpoint display. Also provides removable terminal connector for easy connections. 600 500 400 300 200 100 RESPONSE 0 0 15 30 45 60 75 90 105 120 Time (Seconds) Flow Rate (ml/minute) Tests run on a new, randomly chosen McMillan 500 ml/minute (range 5) liquid flow controller on deionized water with 20 psig input pressure.

PRINCIPLE OF OPERATION The Model U801 Liquid Flo-Controller for UHP applications functions with liquids much the same way a mass flow controller (MFC) operates with gases. A signal is passed to the controller from a user or other external device (such as a computer). That signal is processed and compared to the actual flow rate, which is provided in realtime by the integrated flow sensor. Any difference between the two signals results in adjustments to the internal valve, therefore maintaining the requested flow rate automatically. Figure 1 shows the internal design. The flow sensor utilized in the U801 is McMillan s patented microturbine design. Figure 1. McMillan U801 Liquid Flo-Controller. McMillan s microturbine wheel technology utilizes the Pelton turbine wheel concept. This type of design allows usage of a sub-minature microturbine wheel, only about 0.8 inches (20mm) in diameter. The turbine wheel is then supported on a very small sapphire shaft held in position by two sapphire bearings - see Figure 2. Because of the very light weight of both the wheel and the shaft, the microturbine wheel virtually floats in the liquid. This flotation effect causes the turbine wheel to be suspended in the middle of the bearings and thus eliminates shaft and bearing wear. Therefore, no particles are generated, as is evident in Figure 3, which shows a new sensor virtually at background levels in just a few minutes (data obtained by a third party). As flow passes through the flow sensor, it is directed onto the teeth of the wheel using a precision-machined orifice, which is sized according to flow range. The flow is projected onto the wheel, spinning the wheel faster as flow increases. This speed increase is directly proportional to the increase in flow rate. Figure 2. Microturbine wheel assembly. The microturbine wheel features 8 small windows, spaced evenly around the center of the wheel. As the wheel spins, a light beam is projected through a PTFE 100 window and onto the wheel. A sensor on the 90 0.05µ 0.10µ 0.50µ 1.00µ other side of the wheel detects each hole and 80 translates those signals into pulses. Thus, as the 70 wheel spins faster, more pulses are generated. When the wheel stops, no pulses are 60 generated. 50 The U801 incorporates a double-diaphragm type valve, common in the semiconductor industry. This valve is actuated by an advanced stepper motor to provide precise control and repeatable results. Diaphragm valves require minimum maintenance and the McMillan U801 valve has been tested to millions of cycles with no degradation of performance - which equates to many years of reliable service. Particles/mL above baseline 40 30 20 10 0 2 of 5 1 2 3 4 5 6 7 8 9 10 11 12 13 Time (in 10 minute intervals) Figure 3. Flow sensor particle release in first 130 minutes. Data shown is typical with U801 microturbine design.

DETAILED SPECIFICATIONS Accuracy, including Linearity & Hysteresis ±1.0% Full Scale* Repeatability ±0.20% Full Scale* (based on data accumulated over thousands of cycles) Power Requirements 22-25 VDC; 1.0 A peak, 250 ma typical Pressure Rating Over pressure limit is 80 psig (5.4 bar). Recommended maximum pressure is 60 psig (4.08 bar) Temperature Rating Standard fluid temperature range (internal): 0 to 60 C ** Option Code HT fluid temperature range (internal): 0 to 90 C ** Ambient environment range (external): 0 to 50 C Storage range: -10 to 70 C Materials of Construction Wetted parts - PTFE, sapphire, Kal-Rez Exterior surfaces - PTFE, polypropylene, PVC, FEP-jacketed cable, PVDF, Viton Recommended Filtration 25 microns or less Compatible Fluids Most all liquids compatible with wetted materials. Contact the factory for calibration information on fluids with high viscosities. Input/Output Code B Analog voltage input/output, 0-5 VDC. Voltage level is proportional to flow rate (zero VDC is zero flow). Input load approximately 100 Kohms; output load should be at least 2.5 Kohms. Code C Analog current input/output, 4-20 ma. Current level is proportional to flow rate (4 ma is zero flow). Input load loop is 250 ohms; output current loop should not exceed 500 ohms. Code J Analog voltage input/output, 0-10 VDC. Voltage level is proportional to flow rate (zero VDC is zero flow). Input load is approximately 100 Kohms; output load should be at least 5 Kohms. Optional Relay Error Output R This provides three-wire connections to a relay - common, normally closed, and normally open. The relay is activated when the controller cannot maintain the desired flow rate. Current load should not exceed 500 ma. All units also provide internal setpoint selection, which defeats setpoint input and allows user to adjust setpoint using provided potentiometer. Reliability Testing shows no valve performance degradation with over 1 million full cycles on deionized water at room temperature. At a typical rate of 0.5 million cycles per year, units in similar installations should perform well for at least two years before service. Longer valve life will be experienced in many applications. Reliability tests are ongoing. Microturbine flow sensor life is over 50,000 hours MTBF (tests ongoing). Flow Connections PTFE male flare-type connections on all units. If PVDF flare nuts are required, add option code FN. For alternative nut materials, or to specify other connection types, please contact the factory. Electrical Connections Connections between valve unit and control module FEP-jacketed shielded cable, terminated with 15-pin connector. Length determined by part number - contact factory for custom cable lengths. Connections to control module (all power and signal connections) 12-pin removable connector plug. Connector plug features screw-type terminals that accept wires up to 18 gauge. Standby Mode Standby mode inhibits the valve function upon command. Flow sensor output continues, but all controller functions (including error output and control functions) are disabled. Standby mode may be activated externally by a 24VDC signal applied to pin #8, or will automatically be enabled when the external setpoint falls below 5% of full scale. Packaging Final packaging performed in Class 100 environment. All units double-bagged before shipment. *Full Scale is from 10% to 100% of rated flow (except range 3, which is 15 to 100%). Linearity is best fit straight line. All calibrations performed with deionized water. **Temperature affects fluid viscosity, and changes in viscosity will have effect on full scale output. Zero is unaffected by temperature. Viton & Kal-Rez - Reg TM E.I. dupont de Nemours Co. SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE. 3 of 5

DIMENSIONS (in inches) Valve module: Control Module: 4 of 5

ORDERING INFORMATION Build your Part Number: U801 - <range> - <signal> - <fitting> - <cable> - <valve> - <opt> Flow Range <range> 15-100 ml/minute <range>= 3 20-200 ml/minute <range>= 4 50-500 ml/minute <range>= 5 100-1000 ml/minute <range>= 6 0.2-2.0 L/minute <range>= 7 0.5-5.0 L/minute <range>= 8 1.0-10.0 L/minute <range>= 9 I/O Signal Configuration <signal> 0-5 VDC <signal>= B 4-20 ma <signal>= C 0-10 VDC <signal>= J For relay error output, add R after the signal code (i.e. JR ) Fitting Type <fitting> Range: 3 4 5 6 7 8 9 1/4 male flare <fitting>= F4 available: no no no no 3/8 male flare <fitting>= F6 available: no no no 1/2 male flare <fitting>= F7 available: no no no no Cable Length (cable between valve and control module) <cable> 3 feet (0.92 meters) <cable>= C3 6 feet (1.85 meters) <cable>= C6 10 feet (3.1 meters) <cable>= C10 15 feet (4.6 meters) <cable>= C15 20 feet (6.2 meters) <cable>= C20 25 feet (7.7 meters) <cable>= C25 Differential Pressure / ÄP* <valve> Range: 3 4 5 6 7 8 9 2-10 psid (5 psid*) <valve>= P5 no no no 4-20 psid (10 psid*) <valve>= P10 no no no 5-40 psid (20 psid*) <valve>= P20 no 7-50 psid (25 psid*) <valve>= P25 no no no no no no 10-60 psid (40 psid*) <valve>= P40 * Range shown indicates recommended differential pressure operating range. Low number of range indicates minimum pressure required to flow 50% of rated flow. High number of range indicates maximum differential pressure recommended for stable control. Value in parentheses indicates minimum pressure required to flow 100% of rated flow. Please note that P5 and P10 will only control 20-100% of rated flow. P20, P25 and P40 will control 10-100% of rated flow range (except on range 3, which is 15-100% of rated flow). Additional Options (leave off if none) High Temperature Operation (Fluid Temp: 0-90 C) Include Pair of PVDF Flare Nuts Option Code <opt>= HT <opt>= FN Example: U801-8 - CR - F7 - C10 - P20 - HT would give you a U801 Flo-Controller rated for 0.4-5.0 L/minute. The input and output signals would be 4-20 ma. A relay error output would be included. The fluid connections would be 1/2 male flare. The cable length would be 10 feet, and the recommended differential pressure range would be 5-40 psid. The unit would be rated for fluid temperature from 0 to 90 C. P.O. Box 1340 Georgetown, TX 78627 Phone: (800) 861-0231 / (512) 863-0231 Fax: (512) 863-0671 sales@mcmflow.com www.mcmflow.com 2003 R.D. McMillan Co., Inc. All rights reserved. Printed in the U.S.A. Sales Bulletin U801-S001.