Series 4600F. HSC Fire Pumps & Packaged Systems

Similar documents
FIRE PUMPS & PACKAGED

Horizontal Split Case Fire Pump Series 4600f 60 Hz

Series 40MF. End Suction Fire Pumps & Packaged Systems

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

900 Series Split Case Fire Pump Systems

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

SINCE Double Suction Split Case Fire Pump. Series 4800 & (New Generation) 001-cat f

Series SG & FTV. Suction Guides & Flo-Trex Valves

Fire Pump Systems. For the protection of life and property, A-C Fire Pump offers package systems that meet every fire protection need.

Series Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

PRODUCT OF FIRE PUMPS SYSTEMS

Goulds Small Capacity Double Suction Pump

GROOVED END FLO-TREX COMBINATION VALVE

Head - m. Flow - US gpm. Comments. Customer : Contact : Re Cotizacion Metro Linea 4 EDB Project : Quote No. :

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

Waterfall Pumps Manufacturing

Contents. Identification

Suction Guide & Flo-Trex Valve Series

JOCKEY PUMPS MTH Tool Co. Series T41, T51, 150, 160 Regenerative Turbine Vane Type. TYPICAL SPECIFICATION MTH Tool Co. Series T41, T51 Pumps

FIRE PUMP SYSTEMS. FIRE PUMP SINGAPORE PTE LTD No.8 Keng Chin Road #13-11 Cyan South Tower Singapore

340 Series Double Suction Split Case Pumps

3312 Model. pumping Model Model AURORA Series HORIZONTAL AND VERTICAL CLOSE-COUPLED PUMPS

ZPP and Z22 Double Suction Axially Split Single Stage Centrifugal Pumps

Centrifugal End Suction Fire Pumps

F-Series Fire Fighting Pumps

Bristol: A History & Future.

COMMERCIAL PUMPS SERIES 4700 VERTICAL MULTISTAGE PUMP INSTALLATION AND OPERATING INSTRUCTIONS

SECTION PUMPS GENERAL PUMPS PART RELATED DOCUMENTS

CBV Series. Circuit Balancing Valves

Regenerative Turbine Pumps

Bulletin BX-512H. Bell & Gossett. Series HSC-S Pumps Technical Bulletin. Bell & Gossett. Part of the. Equipment Selection Programs

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

PWA-IL B73.2 IN-LINE

XFLO XS SERIES. Single Stage Double Suction Split Casing Centrifugal Pump

Series HSC-S Pumps Technical Brochure

PWM API 610 BB3 Multistage Pump

University of Houston Master Construction Specifications Insert Project Name

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPP. Heavy Duty, Single Stage ANSI Chemical Process Pump

Fire Protection. FP-XA End Suction

Axially Split Case Pumps

Goulds API th Edition/ISO nd Edition API OH3 Overhung. Vertical In-Line with Bearing Frame. An ITT Brand

PWM. API 610 BB3 Multistage Pump

PWD. PWD API 610 BB1 Single Stage Pump

Six-Inch Submersible Pumps

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

VSC /VSCS Pumps Technical Brochure

HORIZONTAL SPLIT CASING PUMP

Goulds High-Pressure Multi-Stage Pumps

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

NC State University Design and Construction Guidelines Division 23 Hydronic Pumps

Series Split Coupled Vertical In-Line Pumps

Hydropak Booster Systems. Series motralec

PA SERIES END SUCTION CENTRIFUGAL PUMP SINGLE STAGE BACK PULL-OUT DIN24255 THONG FATT JAYA MACHINERY HARDWARE SDN. BHD.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

PWM APi 610 BB3 Multistage Pump

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

EN. 850 Filtrate Pumps. Technical Specification Pages

Regenerative Turbine Pumps

Regenerative Turbine Pumps

G&L Pumps. TECHNICAL Brochure BAC8100. Series A-C 8100 SPLIT CASE PUMPS

ASME END SUCTION PUMPS Catalogue K-90

CE Close-Coupled End Suction Pumps. Leading The Flow. TACO.

855 Filtrate Pump, Close Coupled and Overhead Mounted Pumps

Dry installed end-suction pumps, LSN-series. according to ISO 2858 / ISO 5199

FI / SFI Frame-Mounted End Suction Pumps

SERIES CS CLOSE COUPLED TURBINE PUMPS

D51 D61 D71 D91 Series

SUGGESTED SPECIFICATIONS Pump Frames NS3 thru OMC5

KS / SKS Vertical Split Coupled Inline Pumps

390 Series Multi-Stage Vertical In-Line Centrifugal Pumps

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

A-C Fire Pump. Fitting and Accessories A-C 100A

EFQT/EFQU. EBARA Self Priming Trash Pump. Contents Project: Model: Chk d: Date:

SERIES CS CLOSE COUPLED TURBINE PUMPS

M50 L50 Series Multistage Regenerative Turbine Pumps

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

FLHC SERIES DATA BOOKLET

PROCESS PUMPS MODEL V200 ANSI B73.2

SMN Double-Suction Axially Split Pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

RS Multi-Stage, Ring Section Pumps

4500C Series Vortex Pumps

ZE/ZF Process Pump API 610

SECTION MOTOR REQUIREMENTS for HVAC

IL-DSIL Range Vertical Single Stage Pumps. Excellent Oil & Gas Solutions

3800 Series. Single Stage End Suction Pumps. Capacities to 4200 G.P.M. (954 m 3 /hr) Heads to 520 Feet (180 Meters) Temperatures to 300 F (149 C)

Elite. KSB Australia Pty Ltd. Centrifugal Pump

SM / SMI N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SMD axially split casing, double suction pump

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y JTN. Heavy Duty, Multi-Stage, API 610 Process Pump

900 Series. 2000/2500 GPM High Head. Expanding our line to meet your needs. Model Latest Addition to the Aurora Fire Pump Line

Self-Priming Fiberglass Pumps

F F F F F F. Foam Systems Deluge Systems Hydrant Systems Sprinkler Systems Hose Reel Systems Hose Rack Systems

TKL. Hydro-Titan Heavy Duty Back Pull-out Water & Process Liquid Pump. Experience In Motion

Bulletin C Dean Pump Division. Heavy Duty, High Temperature Process Pumps. R4140 Telescoping Guard. R4140 C-Face Motor Support

Volute Casing Pumps LSN. according to iso 2828 / iso Jansen Pompentechniek T: +31(0) E:

SCE Heavy Duty, Single Stage, Overhung, API 610 Process Pump (OH2)

Transcription:

Series 4600F HSC Fire Pumps & Packaged Systems FILE NO: F43.11 DATE: May 26, 2008 SUPERSEDES: F43.11 DATE: Dec. 15, 2007

Series 4600F Series 4600F - Truly Superior The Series 4600F, drawing on over 100 years of pump design expertise and leadership, is the state of the art in Horizontal Split Case pumps. It meets or exceeds the requirements of NFPA and testing laboratories involved in fire protection such as UL, ULC, & FM. The family of pumps capitalize on the Tilted Parting concept to minimize turbulence at the eye of the impeller by its straight laminar approach, thus maximizing efficiency. The family was designed with commonality of parts, low installation cost, and ease of maintenance objectives. The pumps compact sizes are ideally suited for space saving packages and retrofit applications. Recirculation External Water Seal Recirculation Lines Coupling UL Listed close-coupled coupling Stuffing Box Housing Self contained Combination Bearing & Seal Housing Permits packing change-out without having to be removed Drip Containment Fitted with drain connection Casing Wear Ring Replaceable Case Wear Rings Locked to prevent rotation or axial displacement Impeller Wear Ring available as an option Pump Casing Designed to withstand the high pressure requirement typical in fire protection

Impeller Hydraulically balanced double suction Dynamically balanced Minimum axial thrust High efficiency throughout operating range Shaft Sealing with Packing Three-piece Split Gland standard Packing replaceable without disturbing wetted parts Stuffing Box Extension designed for easy access Shaft Sleeves Replaceable bronze sleeves Protects shaft throughout Stuffing Box Bearings Easy removal with bearing nut Sealed, permanently greased bearings Low Friction Lost Bearing Maintenance free Tilted Parting Design Casing Permits laminar approach to eye of Impeller Lower NPSH required Lower pump profile Minimum pump footprint Removeable rotating element without disturbing piping Low foot-mounted Casing to reduce vibrations Bearing Housing Removable without removing top casing 15 ANGLE CASING Shaft Minimum deflection for long bearing life Minimum vibrations Identical shaft and parts for left and right-hand drives Suction and Discharge on same center line

HSC Fire Pumps & Packaged Systems JOCKEY CONTROLLER FIRE PUMP FUEL TANK 8 4 3 12 2 CONTROLLER 3 1 ARMST RONG 10 9 11 6 7 Horizontal Fire Systems With years of experience in fire protection industry, Armstrong can supply fire pump systems with all necessary accessories ready for site installation. GUARANTEED ADVANTAGES Simplifies piping design Single source unit responsibility A complete package that will meet NFPA-20 requirements FIRE PUMP - ELECTRIC DRIVEN 1. Pump/motor 2. Fire pump controller (with optional transfer switch) 3. Suction and discharge gauges 4. Air release valve 5. Casing relief valve (not shown) 6. Jockey pump 7. Common base FIRE PUMP - DIESEL ENGINE DRIVEN 1. Pump/engine assembled with Cooling system Fuel system Battery system Exhaust system 2. Fire pump controller 3. Suction and discharge gauges 4. Air release valve 6. Jockey pump 7. Common base ACCESSORIES - ADDITIONAL (ELECTRIC OR DIESEL) 8. Suction OS&Y gate valve 9. Discharge butterfly valve 10. Check valve 11. Test tee ACCESSORIES - SPECIAL FOR DIESEL OR VFD 12. Main relief valve 13. Enclosed cone (not shown) Features common to electric and diesel Accessories - (electric or diesel) Accessories - special for diesel or VFD

Fire Pump Coverage Chart Electrical 60 hz Rated Capacity (L/min) 1890 2850 3800 4750 5700 7600 9500 11400 1800 RPM Rated Head (psi) 250 200 150 100 5 X 4 X 10 5 X 4 X 10 6 X 5 X 10 12 X 8 X 18 8 X 6 X 15 3600 RPM 12 X 8 X 18 12 X 8 X 18 1750 1500 1250 1000 750 Rated Head (kpa) 50 5 X 4 X 12 8 X 6 X 15 500 275 500 750 1000 1250 1500 2000 2500 3000 Rated Capacity (USGPM) Electrical 50 Hz Rated Capacity (L/min) 1890 2850 3800 4750 5700 7600 9500 1500 RPM Rated Head (psi) 250 200 150 3000 RPM 1750 1500 1250 1000 Rated Head (kpa) 100 5 X 4 X 10 6 X 5 X 10 10 X 8 X 11 750 50 5 X 4 X 10 6 X 5 X 9.5 8 X 6 X 16 8 X 6 X 16 8 X 6 X 16 8 X 6 X 15 12x8x18 500 275 500 750 1000 1250 1500 2000 2500 Rated Capacity (USGPM) Note: Higher ranges may be available for diesel driven applications.

Typical Specifications Horizontal Fire Pump - Electric Motor Driven* Supply and install as indicated on plans one (1) fire pump system consisting of: 1. FIRE PUMP One Armstrong, SERIES 4600F, Size double suction horizontal split case fire pump listed by [Underwriters Laboratories of Canada (ULC)], [Underwriters Laboratories Inc. (UL)] and/or [approved by Factory Mutual (FM)] having a capacity of USGPM for a pressure boost of PSIG. Suction pressure PSIG. Pump casing shall be of cast iron, axially split with a 15 angle that will minimize NPSH requirements and dimensions. Lower half shall contain suction and discharge nozzles. Suction and discharge connections shall be on the same elevation. Top half and rotating element shall be removable without disturbing the piping. Casing shall be fitted with replaceable bronze wearing rings. Impeller shall be bronze, double suction, enclosed type fully balanced and keyed to an alloy steel shaft. Shaft shall to be fitted with replaceable bronze sleeves. Shaft shall be mounted in two dust tight deep grooves, sealed, and permanently greased ball bearings. 5. FIRE PUMP CONTROLLER The fire pump controller shall be specifically approved for fire pump service by [ULC], [UL] and/or [FM]. The controller shall be of the combined manual and automatic stop, starting method, Model as manufactured by. All equipment shall be enclosed in an approved drip proof enclosure. The control equipment shall be completely assembled, wired and tested at point of manufacture prior to shipment. Circuit breaker shall have an interrupting capacity of kamps or a withstand rating of kamps RMS. Water pressure switch shall be suitable for PSI working pressure. 5A. FIRE PUMP CONTROLLER AND AUTOMATIC TRANSFER SWITCH COMBINATION The automatic transfer switch controller combination shall be approved by [UL], [ULC] and/or [FM], Model as manufactured by. The automatic transfer switch and the pump controller shall each be mounted in separate enclosures, mechanically attached to form one unit and provide for protected interlock wiring. Bearings shall be mounted in cartridge type housing so that they shall be replaceable without opening pump casing. Bearings shall be easily removable by rotating bearing removal nut. No special tools or bearing puller are to be necessary. Each stuffing box shall be fitted with a three piece bronze gland. Stuffing box shall be fitted with a stuffing box extension to facilitate the packing rings removal. Packing rings shall be removable without disturbing wetted parts or the pump bearings. Water seal recirculation lines made from non-corroding material shall be piped to pump volute. 2. ELECTRIC MOTOR The fire pump shall be directly coupled through flexible coupling to a horizontal electric motor with a maximum HP of at RPM, VOLT, PHASE CYCLE. Motor shall be UL Listed for fire pump service, open drip proof, standard efficiency with 1.15 service factor. 3. MINIMUM FITTINGS The pump shall be supplied with the following accessories: One (1) combination suction gauge 3½ dial type with ¼ cock and lever handle. One (1) discharge gauge, 3½ dial type, with ¼ cock and lever handle. One (1) air release valve. One (1) casing pressure relief valve. 4. OTHER ACCESSORIES Pump shall be fitted with one (1) eccentric suction reducer and one (1) concentric discharge increaser, as required (by mechanical contractor) to fit NFPA20 recommended piping sizes. One (1) outside test header shall be supplied with one (1) set of x 2½ hose valves with caps and chains. * The automatic transfer switch shall be capable of automatic power transfer from normal to alternate [generator] / [second utility] emergency power source in case of normal supply failure and automatically re-transfer after restoration of normal power conditions. 6. JOCKEY PUMP The jockey pump shall be manufactured by Model for a capacity of USGPM and a pressure boost of PSIG. The jockey pump shall be driven by an [open drip proof] [totally enclosed fan cooled] electric motor of HP RPM VOLT PHASE CYCLE. 7. JOCKEY PUMP CONTROLLER The jockey pump shall be controlled by an automatic jockey pump controller model as manufactured by with full voltage starter. 8. MOUNTING AND TESTING The fire pump shall be suitable for a maximum working pressure of. The fire pump shall be hydrostatically tested at twice the maximum working pressure for at least 5 minutes. The fire pump shall be performance tested at rated speed. The fire pump shall furnish not less than 150% of rated capacity at a pressure not less than 65% of rated head. The shut-off total head of the fire pump should not exceed 140% of total rated head. A certified test curve, indicating the flow, head, power and efficiency shall be supplied for the field acceptance test. The fire pump and electric motor shall be base mounted and aligned at the pump manufacturer s factory. Final alignment shall be made after installation on site Please refer to Armstrong Fire Pump Catalogue for Diesel Driven Typical Specifications. S. A. Armstrong Limited 23 Bertrand Avenue Toronto, Ontario Canada, M1L 2P3 T: (416) 755-2291 F (Main): (416) 759-9101 Armstrong Pumps Inc. 93 East Avenue North Tonawanda, New York U.S.A., 14120-6594 T: (716) 693-8813 F: (716) 693-8970 Armstrong Holden Brooke Pullen Wenlock Way Manchester United Kingdom, M12 5JL T: +44 (0) 161 223 2223 F: +44 (0) 161 220 9660 S.A. Armstrong Limited 2008 For Armstrong locations worldwide, please visit www.armstrongpumps.com