INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL HS305

Similar documents
INSTRUCTION MANUAL TIPPING BUCKET RAIN GAUGE MODEL HS305

SBS Range Rain Gauge User Manual

INSTRUCTION MANUAL LABORATORY CALIBRATION UNIT MODEL TB340

STORM Guardian. Operator s Handbook

ARG100 Rain Gauge User Manual

TABLE OF CONTENTS. Contents CONTENTS... PAGE. Jan 2006 COPYRIGHT. Tipping Bucket Rain Gauges User Manual. Tipping Bucket Rain Gauges User Manual

Kalyx-RG Rain Gauge User Manual

Siphon Tipping Bucket & Operations & Maintenance Manual

TR-4 Tipping Bucket Rain Gauge User s Manual

Rain Gauge RG13 and RG13H USER'S GUIDE

RS-110 Rainfall Sensor Installation Guide

Belt-Way Integrator Features

Data-Logging Rain Gauge PRODUCT MANUAL

NECO Pumping Systems

METEOROLOGICAL INSTRUMENTS

Tipping Bucket Assembly for Snow Lysimeters Installation and Use

C-Drive 7 Motor Control Unit For Electric Steering & Autopilots

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

UPG1000 & Windshield. Manual

Digital Tipping Bucket Rain Collector PRODUCT MANUAL

HOUSTON OILFIELD EQUIPMENT 9669 PORT ERROLL RD. HOUSTON, TX PHONE: (713) FAX: (713)

Ørstedsvej Silkeborg DENMARK

Rain Collector (#7857 & 7857M)

HD [ GB ] Tipping bucket rain gauge

Rain Gauge Smart Sensor (Part # RGA-M0XX, RGB-M0XX)

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

Environdata Sensor Guide

HOBO Data Logging Rain Gauge (RG3 and RG3-M) Manual

T-200B SERIES PRECIPITATION GAUGE

General Purpose Buck - Boost Wiring Diagrams... 86

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

Met One Meteorological Monitoring Station

DATA LOGGING RAIN GAUGE MANUAL Part # RG2 and RG2-M

Displacement Sensor. Model 8739, 8740, 8741

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

M3770: SOLENOID CONTROLLED / ELECTRICALLY POSITIONED VALVE - STEP BY STEP VALVE

MOTOR INSTALLATION. Knowledge of proper installation techniques is vital to the effective operation of a motor

KOBOLD KSK FLOWMETER. User Instructions

KOBOLD DF-MA Flow Transmitter. User Instructions

TX 115/215 Hot-tap Insertion Turbine Instructions

CORPORATION REPAIR MANUAL HWH SPACEMAKER ROOM EXTENSION SYSTEM NO LEVELING SYSTEM FOR NATIONAL RV NON-MOTORIZED VEHICLES

Your Name Lab Section

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Operators manual Bumpa 8 metre 110v Bumpa 10 metre 110v

TESTING/VERIFICATION MANUAL FOR WEIGHBRIDGES

Operators manual Hoddi 6 metre 110v Bumpa 8 metre 110v Bumpa 10 metre 110v

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

NIAGARA. Series WPX. Installation, Operation & Maintenance Manual. Models 210 and 222. Series WPX

B BASIC HEAT TREATMENT CONSOLE

TX115/215 Hot-tap Insertion Turbine Instructions

APPENDIX A. 15 DUAL WELD STATION FUME EXTRACTION with 30 WELDING BOOTHS

NATIONAL TURBINE CORPORATION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG CEG

GPS AutoSteer System Installation Manual

Last date for sending comments : 30 November 2011

OD DIGITAL DISSOLVED OXYGEN CONTROLLER POLAROGRAPHIC CELL

Outdoor Enclosure Power System ENC X100MP48F20-AC6

Pre-lab Quiz/PHYS 224 Ohm s Law and Resistivity. Your name Lab section

Operating & Installation Manual

PAPI System Hella Induperm type 801 USER MANUAL GB

TX101/201 Insertion Turbine Instructions

California Friendly Landscape Training

PROMAG SR SERIES SEAL-LESS CENTRIFUGAL PUMPS

APPENDIX A USACE INSPECTION ITEMS AND RATINGS GUIDELINES

COMPLETE WEATHER STATION USER S MANUAL

N-03 STEERING GEAR CONTROL SYSTEMS

RATE CONTROLLED TORQUE WRENCH TESTER

TX101/201 Insertion Turbine Instructions

ETgage Model E Instructions

Requirements LEO Power Operator Installation Instructions Patents: 5,881,497; 7,316,096; 7,484,333 CAUTION CAUTION WARNING

Outdoor Enclosure Power System ENC X100MP48F20

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

IMPORTANT: Before you install the automatic gate lock be sure your gate is level, moves freely on hinges, and is free from binding and/or dragging.

Dosage Pumps - Installation Guide

Installation Instructions

INSTRUMENT TEST REPORT 652. Evaluation of a Tipping Bucket Rain Gauge Calibrator

McCANNA Actuation Systems B

Gauges, Sight Glasses and Vacuum Breakers

Callisto 100. Cold Filter Plugging Point Tester

MAINTENANCE NOTICE. YM-2000 Switch Machine Motor Cutout Switch Adjustment. (US&S Part No. N , N , N )

MAJOR INSPECTION SPECIFIC RECOMMENDATIONS

StopGate TM Barrier Arm GENERAL SPECIFICATIONS

User manual. B950I, B1000i, B2000i, B3000i

Stepper Motor Drive. Description: Specifications:

M-200 Series. High flow, Adjustable flow switch with right-angle flow

Agro-Meteorological Station

PRODUCT INFORMATION BULLETIN

Adjustable Flow Switches

KOBOLD DF-WM Flow Monitor. User Instructions

Diesel generator set QSK23 series engine

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG

TomTom-Tools GmbH Wiesenstrasse Baden Switzerland. Phone 1: Phone 2: VAT ID:

Georgia Pacific Crossett Operations Hydrogen Sulfide and Meteorological Monitoring Program

Impeller Replacement

Standard Operating Procedure for Detecting MEA Triazine in a Crude Oil Matrix using LONESTAR TM

before serial number 2214

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Pneumatic Rotary Actuator Type 3278

GPS AutoSteer System Installation Manual

TELETOM PREINSTALLATION MANUAL

Transcription:

INSTRUCTION MANUAL TIPPING BUCKET RAINGAUGE MODEL HS305 HS305 100-01

CONTENTS Page I General HS305 100-03 II Specification HS305 100-03 III Installation HS305 100-04 IV Test Operation HS305 100-05 V Maintenance HS305 100-05 VI Electrical HS305 100-06 Schematic Layout HS305 100-07 Parts List HS305 110-01 HS305 100-02

TIPPING BUCKET RAINGAUGE MODEL HS305 I. GENERAL The HS305 raingauge operates on the tipping bucket principle. A receiver of 305mm diameter collects the rainfall which is strained by a metal gauze before being passed to the synthetic ceramic coated tipping bucket measuring system. Tips of the bucket occur with each 1.0mm of precipitation collected and a reed switch detects these events and produces a momentary contact closure signal for logging in our Rain/River Data Logger Model RRDL-3, for transmission by our Radio Reporting Raingauge Model RRG-1 or for display on our Rainfall Counter. II. SPECIFICATION Receiver (cover) : Diameter 305mm (within + 0.5mm) Sensitivity : One switch closure per tip of 1mm bucket. Measuring range : Max. rainfall intensity, 600mm/hr Measuring accuracy : Better than 2% @ 100mm/hr. Sensor : Tipping bucket (synthetic ceramic coated brass). Contact system : Dual reed switches (glass encapsulated normally open contact) Contact capacity : 12 VA (maximum current 0.5 amp) Contact time : 0.1 second HS305 100-03

III. INSTALLATION (i) Site Selection Rainfall measurements are intended to be representative of the actual rain falling on a given area. Some of the more important factors which influence the representativeness of a gauge are as follows: a) Site the gauge on level ground where possible. Avoid sloping sites. b) Site should have adequate protection from strong winds. c) Site should be free of large obstructions such as buildings and trees. d) Provide suitable ground surface to avoid splashing into the gauge. (ii) Setting up a) Remove the gauge from package b) Install the gauge on the foundation. c) Remove the enclosure from the gauge - to do this, loosen the three screws (Item 18)and lift off. d) The gauge is provided with a bullseye level. Level the gauge adjusting the nuts on the anchor bolts. e) Connect lead to recording instrument. f) Remove elastic band from bucket assembly. g) Remove packer between bucket (8) and adjusting screw (6). h) Manually tip the bucket a number of times, ensuring that each tip is being recorded and that the tipping mechanism is operating freely. i) Replace the enclosure. HS305 100-04

IV. TEST OPERATION 1. Measure a volume of water corresponding to 10mm of rainfall using a rainfall measure and pour it very slowly, over about 15 minutes, into the receiver. This creates a condition of heavy rain striking the ground sufficient to make a pool of water of the ground. 2. If a rainfall measure is not at hand, pour 726cc or water into the 305mm receiver. (Since 1mm rainfall measured in this apparatus corresponds to approximately 72.62cc, 72.6 x 10 = 726cc) 3. After this water has passed through the gauge, the Tipping Bucket should have tipped: 10 times 1.0mm Bucket and the recording device should indicate a reading equivalent to 10mm of rain. 4. If the above results cannot be obtained, check the following points: a) Is the apparatus levelled accurately? b) Is the wiring correct? c) Is the battery condition OK? d) If the above (a to c) are OK, refer to 'Calibration' Section VIII V. MAINTENANCE The only routine maintenance required is cleaning. The following items should be checked regularly for cleanliness: a) Catch filter b) Syphon c) Interior of bucket d) Top surface of adjusting screws e) Lubricate enclosure locking screws with plus oil, part no. SC034-02. f) All insect screens HS305 100-05

VI. ELECTRICAL Dual reed switches are provided for several reasons: a) Two isolated switches permit the control of two separate circuits; e.g. a local counter and a telemetry circuit. b) Parallel connection of both switches increases the current carrying capacity of the contact system if required. c) Parallel switch operation confers a degree of redundancy in locations where data from the raingauge is critical to flood warning etc. DIAGRAM 1 HS305 100-06

DIAGRAM 2 HS305 100-07

TIPPING BUCKET RAINGAUGE MODEL HS305 PARTS LIST (Refer Diagram 2) ITEM DESCRIPTION PART NO. QTY/ASSY 1 SPIN BASE HS305-02 1 2 CAST BASE HS305-01 1 3 ENCLOSURE HS305-03 1 4 FUNNEL ASSEMBLY HS305-04 1 5 TIPPING BUCKET HS305-05 1 6 BUCKET SHAFT HS305-05-01 2 7 PIVOT SCREW HS305-06 2 8 PIVOT LOCK NUT TB301-06 2 9 STOP SCREW TB312 2 10 LOCK NUT SCO08-24 2 11 LEVELLING WING NUTS M6 2 12 GUIDE SCREWS M6 X 45 3 13 REED ASSEMBLY TB303 1 14 BULL'S EYE LEVER SCO23-09 1 15 SYPHON HS305-09 1 16 SPRINGS HS305-07 3 17 FILTER ASSEMBLY TB310 1 HS305 110-01