Ductable water unit FWD UNT-PRC002-E4

Similar documents
Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Commercial Blower Coil Air Handlers

CHILLED WATER FAN-COIL UNITS

CENTRIFUGAL FAN COIL UNIT VCE

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

Product Data. Convertible Air Handlers 1 1/2 5 Ton B-EN. August 2015

Product Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP

Fan Coil Units. Technical Data. Conceiled ceiling unit ECDEN FWB-BT

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

High Static Pressure Duct Fan Coil Unit

CFM (L/s) Min Max 450 (212) 600 (283) 750 (354) Dimensions H x W x D in. (mm) 675 (319) 36 1/2 x 20 1/2 x (425)

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

Fan coil unit NBS 100/150

The World Leading Air-conditioning Company

AHN 064 to 304 EHN/CHN 064 to 304

42HS Fan Coil Unit (High Static Pressure)

HRS. Very high efficiency heat recovery units. from 300 to m³/h >90 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

HEAT-RECOVERY UNITS WITH ENTHALPY/ROTARY HEAT EXCHANGER TECHNICAL MANUAL

ACOUSTIC CABINET FANS CVB / CVT Series

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Modular Air Handling. Up to 3,500 Litres / sec. Low profile & Plant room application. Draft. Version. Second Edition A-. AirDesign 2015 AirDesign 2016

Fan Coil Units. Technical Data. Flexi type unit ECDEN FWD-AT/AF

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

Chilled Water Fan Coil Unit. DCBL VAV Stepless FCU Model : HFCF02~HFCF14

CFM (L/s) Dimensions. Filter Size Ship Wt. H x W x D in. (mm) 1800Aǂ 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data. FFMA Base Series Fan Coil Sizes 018 thru 037 FEATURES

Product Data FFMA BASE SERIES FAN COIL SIZES 018 TO 037 FEATURES

Fan Coil Units. Technical Data ECDEN FWL-DT/DF

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

DIRECT-AIR ILB / ILT Series Rectangular duct fans

WATER SOURCE HEAT PUMPS

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

CFM (L/s) Dimensions. Filter Size in. Ship Wt. H x W x D in. (mm) 1800A 1 1/2 18, (212) 675 (319) 36 1/2 x 20 1/2 x 15

Prepared By : Checked By : Approved By : Page 1 out of 6

CFM (L/s) Dimensions. Filter Size Ship Wt. HxWxDin.(mm) 1800Aǂ 1-1/2 18, (212) 675 (319) 36-1/2 x 20-1/2 x (45) FMA4P (928 x 521 x 381)

2 1/2 Ton Convertible Air Handler TAM7A0B30H21SD Standard Coil TAM7A0B30H21EA Black Epoxy Coil

3 1/2 Ton Convertible Air Handler TAM7A0C42H31SD Standard Coil TAM7A0C42H31EA Black Epoxy Coil

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

FCC DUCTABLE AIR TREATMENT UNIT

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Specifications & Submittal

HRH. High efficiency heat recovery units. from 300 to m³/h >70 % WITH HIGH EFFICIENCY HEAT RECOUPERATOR

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

Technical Service Manual

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation. Low Energy Consumption

CWP-CO / CWP-RC / CWP-HP 02 to 35

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

42NL & 42NH. Hydronic Ducted Fan Coil Units PRODUCT SELECTION DATA. Modular Horizontal ducted unit. Extremely quiet operation

IDENTIFICATION ACCESSORIES DESCRIPTION

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

Fan coil units. Why choose Daikin fan coil units? 540 Products overview 542. Options & accessories 560. Round flow cassette 544 FWC-BT/BF 544

VERSO-CF H-PM/IE5/2/2-F7-M5-HW/4R/2.6-X-R1-C5.1-X

Fan Coil Units. Technical Data

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

FMU4X, FMC4X FMU4Z, FMC4Z

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

T Series. The most reliable HVAC system for transit is now better than ever.

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

Specification. 3 Ton Convertible Air Handler TAM7A0C36H31SC TAM7A0C36 SPEC-1D

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

Product Data. Single Packaged Gas/Electric 15 SEER Convertible, 2 5 Ton A-EN. July 2016

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

BUILDING EFFICIENCY Energy Efficient Variable Speed EC Motor Fan Coil Unit Solutions Model YECFC

Air Conditioners. Technical Data UATYQ-CY1

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

Model METRIC SHAFT WT (LBS) mm mm mm mm mm mm mm 572

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

Product Data. FPMA Sizes 018 thru 036 FPMB Sizes 018 thru 030 Base Series Horizontal Fan Coil

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

VXI Closed circuit cooling towers

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

MCE4 MCE4. Electric Heating / Electric Cooling Packaged Thru-the-Wall Units

Regulation and shut-off damper SPB and SPC

Vertical Air Handling Unit type

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

Transcription:

Ductable water unit FWD 08-1 - 0-0 - 4 UNT-PRC00-E4

Table of Contents General data... Performance data... 4 Cooling capacities... 4 Heating capacities... Water pressure losses... 6 Available static pressure... Sound power levels... 8 Accessories... 9 Hot water coil... 9 Plenums... 11 Filter boxes... 11 01 Trane UNT-PRC00-E4

General data FWD 08 1 0 0 4 Power supply Capacities (V/Ph/Hz) 0/1/0 Cooling capacity on water (1) (kw), 8, 18,8 0,1 Heating capacity on water () (kw) 6, 11,9 18,9 0,9 8, Fan motor (type) x direct drive centrifugal Fan power input () (kw) 0, 0,46 0,6 1,04 1,1 Current amps () (A) 1,1,,1 4,, Start-up amps Air flow (A),, 9, 14,1 16, minimum (m /h) 490 980 1400 1800 00 nominal (m /h) 80 160 00 000 400 maximum (m /h) 980 190 600 600 400 Main coil Water entering/leaving connections (type) ISO R rotating female (Dia) /4" /4" 1 1/" 1 1/" 1 1/" Hot water coil (accessory for blower only) Heating capacity (4) G filter (filter box accessory) (kw) 6, 1 1,4,4 4, Quantity Dimensions ( LxWxth) G4 filter (filter box accessory) (mm) 86x1x8 486x1x8 86x1x8 86*41*8 86*61*8 Quantity - Dimensions ( LxWxth) (mm) - 486x64x48 86x14x48 86*414*48 86*614*48 Condensate pump (accessory) (type) Centrifugal Water flow - lift height Not available for FWD0 and FWD4 Sound level (L/M/H speed) (l/h - mm) 4-00 Sound pressure level () (db(a)) 6/40/4 8/41/44 46/0/ 4// 4//8 Sound power level () Unit dimensions (db(a)) 46/0/ 48/1/4 6/60/6 /6/6 /6/68 Width x Depth (mm) 890 x 600 1090 x 10 190 x 80 190 x 90 190 x 1090 Height Shipped unit dimensions (mm) 0 00 0 40 60 Width x Depth (mm) 9 x 644 11 x 4 1 x 864 1 x 1008 1 x 11 Height (mm) 60 10 60 460 660 Weight (kg) 46 61 6 118 Colour galvanised steel Recommended fuse size Unit alone (am/gi) (A) 8/16 8/16 8/16 8/ 8/ (1) Conditions: Water entering/leaving temperature: /1 C, Air inlet temperature /19 C DB/WB - Nominal air flow () Conditions: Water entering/leaving temperature: 0/4 C, Air inlet temperature 0 C DB - Nominal air flow () At high speed with nominal air flow. (4) Water entering/leaving temperature 90/0 C, air inlet temperature 0 C DB, Nominal air flow. () A rectangular glass wool duct 1m0 long is placed on the blower.the measurement is taken in the room containing the blower unit. Heat exchanger operating limits: FWD: *water temperature: max 100 C *absolute service pressure: min 1 bar/max 11 bars Accessories - Hot water coil: *water temperature: min. + C/max. 100 C *absolute service pressure: min 1 bar/max 11 bars UNT-PRC00-E4

Performance data Cooling capacities Unit W.E.T. Cooling capacity (kw) ( C) Air inlet temperature DB/WB ( C) 1/ /16 /1 /19 9/1. 4. 4.9 6..8.. 4. 6. FWD 08 9.6. 4..6 80 m /h 11 1.4..4 4. 1 0.9 1.4.1.. 0. 0.9 1.4.1.. 6..8 10.1 1.8..1 6. 8. 10.9 FWD 1 9. 4. 6.6 8.9 160 m /h 11.1.8 4.1. 1 1.4.1.8 4.. 0. 1.4 4. 10. 1. 14. 1.8 1.9 8.1 9.9 11. 18.9 FWD 0 9 6..8 9. 1..8 00 m /h 11 4.4 6..9 9.8 1. 9 1.9 4. 6.4 8 10. 1. 4. 6.4 8.1 1.4 1.8.4. 9.9 1. 14.6 18.8.8 FWD 0 9. 9. 11.9. 19.9 000 m /h 11.1. 9.8 1. 16. 1 1.4.4.8 9.9 1. 1...6 8 10 1 4. 8.. 4.8 16. 19.8.4 0.1.9 FWD 4 9 1.. 19 4.6 1.8 400 m /h 11 8.8 1.. 19.. 8 1.8 9.1 1..9 0.4.9 6.1 9.4 1.9 16.1 W.E.T.: Water entering temperature Water temp. delta: C Capacities at indicated nominal air flow QW = 4186 x m /s (l/s) x t C = kw Capacity correction factors 1. Water temp. delta ( C) 1.0 0.1 9 0.4-0% 0.8 Air flow Nominal 1 + 0% 1.1 0.8 Ethylene-glycol (%) 0 0 0.0 0.6 0.61 4 UNT-PRC00-E4

Performance data Heating capacities Unit Water ent./leav. Heating capacity (kw) temp. ( C) Air inlet temperature DB ( C) 0 10 0 4/40. 6.. 8.6 9.8 FWD 08 0/4 6.. 8.6 9.8 10.9 80 m /h 0/0 9. 10.4 11.6 1. 1.9 90/0 14. 16.4 1. 18. 4/40 9.6 11.8 14 16. 18.4 FWD 1 0/4 11.9 14.1 16. 18.4 0.6 160 m /h 0/0 16.8 19.1 1... 90/0 6.1 8. 0. 4 4.9 4/40. 18.9.. 9.1 FWD 0 0/4 18.9.. 9.1. 00 m /h 0/0.9 1.4 4.9 8.4 41.8 90/0 4. 4.6 49..9 4/40 1 0.8 4.6 8.. FWD 0 0/4 0.9 4. 8.. 6.1 000 m /h 0/0 0.1 4.9 41.8 4.6 90/0 46 49.9..6 61.4 4/40 1. 8.1 4 1.8 8.6 FWD 4 0/4 8. 4 1.9 8. 6. 400 m /h 0/0 6.8 6.9 0.9.8 84.8 90/0 8. 9.4 99. 106.1 11 Capacities at indicated nominal air flow Capacity correction factors Air flow - 0% Nominal + 0% 0.84 1 1.14 Ethylene-glycol (%) 0 0 0.99 0.98 0.9 0.96 UNT-PRC00-E4

Performance data Water pressure losses on FWD 08 to 4 Coil and headers 08 1 0 100 0 4 10 Pressure losses (kpa) 0,1 1 1 Water flow (l/s) Main coil volume Size 08 1 0 0 4 Volume (l) 1.6..6 4.9.9 Pressure losses of -way valves for FWD 08-4 Coil and headers 08-0/bypass 08-0/ouverte 0-4/bypass 0-4/ouverte 100 10 Pressure losses (kpa) 1 0,1 1 10 Water flow (l/s) 6 UNT-PRC00-E4

Performance data Available static pressure Dry coil without filter FWD08 Available static pressure (Pa) Air flow (m /h) 00 0 600 60 00 0 800 80 80 900 90 1000 Fan 1 (PV) 4 18 speed (MV) 98 88 8 1 6 4 4 8 16 (GV) 116 109 100 9 8 4 68 6 6 6 49 41 FWD1 Available static pressure (Pa) Air flow (m /h) 1000 100 1100 10 100 0 100 10 1400 140 00 0 1600 160 100 10 1800 180 1900 190 000 Fan 1 (PV) 4 6 speed (MV) 160 14 11 11 10 8 6 4 9 10 (GV) 08 0 19 19 18 181 16 11 16 160 149 144 18 10 1 114 104 9 8 FWD0 Available static pressure (Pa) Air flow (m /h) 1400 00 1600 100 1800 1900 000 100 00 00 400 00 600 Fan 1 (PV) 99 44 18 speed (MV) 186 19 1 16 148 11 114 9 (GV) 04 199 19 190 186 181 16 11 16 144 18 11 FWD0 Available static pressure (Pa) Air flow (m /h) 1800 1900 000 100 00 00 400 00 600 00 800 900 000 100 00 00 400 00 600 Fan 1 (PV) 180 160 141 1 101 80 6 0 0 speed (MV) 66 44 0 0 194 181 16 19 119 94 69 6 0 0 (GV) 8 9 0 11 0 9 84 6 6 8 49 40 1 10 198 18 1 160 FWD4 Available static pressure (Pa) Air flow (m /h) 00 800 000 00 400 600 800 4000 400 4400 400 4600 4800 000 00 400 Fan 1 (PV) 66 6 4 198 10 19 0 speed (MV) 6 4 68 6 6 0 9 0 19 14 19 10 (GV) 9 9 88 84 80 6 1 6 6 9 4 0 40 9 19 = At nominal air flow The empty boxes correspond to flow-pressure ranges that cannot be used. UNT-PRC00-E4

Performance data Sound power levels Discharge Measurement conditions: Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1. m long) fixed to its discharge opening. Fan Power level in db(a), per Hz frequency band Overall power Unit speed 0 00 1000 000 4000 8000 db(a) 1 0 4 1 0 46 FWD 08 4 4 40 0 8 40 0 8 0 4 40 4 1 1 4 4 4 8 48 FWD 1 10 8 4 48 4 8 9 1 60 8 0 48 40 4 9 4 1 1 4 4 4 8 48 FWD 0 1 8 4 48 4 8 9 1 60 8 0 48 40 4 9 4 1 6 6 0 48 9 8 6 6 FWD 0 14 61 66 4 46 4 60 6 69 8 6 0 0 49 6 1 6 1 49 40 9 FWD 4 0 61 66 4 46 4 60 6 69 8 6 0 0 49 6 Intake Measurement conditions: Measurements taken at the horizontal air intake. Fan Power level in db(a), per Hz frequency band Overall power Unit speed 0 00 1000 000 4000 8000 db(a) 1 6 46 4 4 FWD 08 6 6 60 60 64 66 6 6 6 6 6 1 6 8 8 1 48 44 61 FWD 1 10 66 6 60 6 6 66 0 6 6 6 9 9 69 1 6 8 8 1 48 44 61 FWD 0 1 66 6 60 6 6 66 0 6 6 6 9 9 69 1 66 6 6 6 0 46 68 FWD 0 14 69 1 64 9 4 8 6 69 64 6 8 1 68 64 64 6 0 69 FWD 4 0 6 6 68 1 6 61 61 8 9 1 4 69 66 66 8 8 UNT-PRC00-E4

Accessories Hot water coil Heating capacities Unit Water ent./leav. Heating capacity (kw) temp. Air inlet temperature DB ( C) ( C) 0 10 0 60/40.. 4. 4.9 FWD08 0/0.8 4.4.6 6. 80m /h 80/60.1.6 6. 6.8.4 90/0 6. 6.9. 8.1 8. 60/40. 6.4. 8. 9.6 FWD1 0/0.6 8.6 9. 10.8 11.8 160m /h 80/60 9.8 10.9 11.9 1 14.1 90/0 1 1.1 14.. 16.4 60/40 8 9. 11 1. 14 FWD0 0/0 11.1 1.6 14.4.6 1. 00m /h 80/60 14.. 1. 18.8 0.4 90/0 1.4 18.9 0.4. 60/40 9.8 11.9 1.9.9 1.9 FWD0 0/0 14.1 16.1 18.1 0.1.1 000m /h 80/60 18. 0.. 4. 6.4 90/0.4 4. 6. 8. 0.6 60/40.8 18.9 1.9 4.9.8 FWD4 0/0.1.1 8.1 1.1 4.1 400m /h 80/60 8. 1. 4..4 40. 90/0 4..6 40.6 4. 46.8 Capacities at indicated nominal air flow, and atmospheric pressure of 101. kpa This accessory can only be used when the unit is blowing air. Capacity correction factors Nominal - 0% air flow +0% 0.8 1 1.10 Air pressure losses (Pa) Unit Nominal -0% air flow +0% FWD 08 6 8 11 FWD 1 8 1 16 FWD 0 8 11 14 FWD 0 11 14 FWD 4 11 14 UNT-PRC00-E4 9

Accessories Water pressure losses Coil FWD0 FWD1 FWD08 FWD4 FWD0 100 10 Pressure losses (kpa) 0,1 Pressure losses (kpa) 1 1 Coil volume Size Volume (l) 08 0.4 1 0.6 0 0.9 0 1. 4 1.8 Water pressure losses -way valve 100 80 Pressure losses (kpa) 60 0 40 0 0 10 8 6 4 1 0.0 0.04 0.0 0.06 0.08 0.1 0. 0. 0.4 0. 0.6 0.8 1 Pressure losses (kpa) 10 UNT-PRC00-E4

Accessories Circular duct adapter plenum Technical and dimensional data The plenum is made of galvanised unpainted sheet steel Unit Number Diameter of Dimensions of connections connections (mm) LxPxH (mm) FWD 08 160 89x0x0 FWD 1 00 1118x4x FWD 0 0 x61x0 FWD 0 190x44x40 FWD 4 x+x400 190xx60 Air pressure losses (Pa) ( central connection pieces used) Unit -0% Nominal flow +0% FWD 08 10 14 FWD 1 0 9 9 FWD 0 4 1 FWD 0 4 FWD 4 4 G and G4 Filter boxes Technical and dimensional data The plenum is made of galvanised unpainted sheet steel EU filter EU4 filter Dimensions Unit Quantity LxWxth.(mm) %arrestance Quantity LxWxth.(mm) %arrestance LxHxD (mm) FWD 08 86x1x8 81 x - - 96x6x108 FWD 1 486x1x8 81 486x64x48 90 996x86x108 FWD 0 486x1x8 81 86x14x48 90 1196x6x108 FWD 0 86x41x8 81 86x414x48 90 1196x46x108 FWD 4 86x61x8 81 86x614x48 90 1196x66x108 Air pressure losses (Pa) with clean EU filter Unit -0% Nominal flow +0% FWD 08 14 18 FWD 1 19 4 9 FWD 0 0 6 FWD 0 19 4 8 FWD 4 19 4 8 Air pressure losses (Pa) with clean EU4 filter Unit -0% Nominal flow +0% FWD 08 - - - FWD 1 0 44 60 FWD 0 0 41 1 FWD 0 8 8 49 FWD 4 8 8 49 UNT-PRC00-E4 11

Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. 01 Trane All rights reserved UNT-PRC00-E4_11 Supersedes UNT-PRC00-E4_081 We are committed to using environmentally conscious print practices that reduce waste.