Compresseur scroll. Refrigerant R410A SYSAQUAC. Air Cooled Condensing Units Models 25 to to 136.0kW

Similar documents
Chiller. AQL/AQH 40 to 75. Air Cooled Water Chillers Cooling Only and Heat Pump Engineering Data Manual to 77.2 kw to 75.

Chiller. VLC 524 to Air Cooled Condensing Units Engineering Data Manual. 154 to 347 kw

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Chiller. AQSL 2612 to Air Cooled Chillers With or without total heat recovery Engineering Data Manual. 602 to 908 kw

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

AQVL (Cooling Only Version) AQVH (Heat Pump Version)

VLS (Cooling Only) VLH (Heat Pump Version) VLR (Total Heat Recovery Version)

WQL/WQH/WQRC 524 to 1204

AQVSL/AQVSH STAR 85 to 140

AQWL/AQWH/AQWR 1404 to 2406

technical catalogue tetris KW Chiller and heat pumps air/water

CWP-CO / CWP-RC / CWP-HP 02 to 35

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

UMXCA/UMXCBA ECVA/ECVBA

Air-Cooled Liquid Chiller with integrated hydraulic module

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

ENR Incorporating

AHN 064 to 304 EHN/CHN 064 to 304

Section 5 AIR - COOLED CONDENSING UNITS MODEL PC 05Z TO PC NOMINAL COOLING CAPACITY RANGE 56.6 TO 772 MBH

CATÁLOGO TÉCNICO COMERCIAL

Flex Series. Modular Air-cooled Chillers and Heat Pumps Cooling Capacity kw Heating Capacity kw

SPLIT DUCTED UNIT SCA300C / SCA300E TECHNICAL SELECTION DATA SPECIFICATION SUMMARY UNIT FEATURES CONTROL OPTIONS UNIT COMPLIANCE

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

LUI / LUO. Condensing Units

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

VHA. Air cooled chiller with

D M S 760 C01 A A 1 1

LHA LHA A ++ High efficiency air to water heat pumps EVI EVI EVI DC. Versions

TECHNICAL CATALOGUE SELF CONTAINED HORIZONTAL AIRCONDITIONERS Rev105

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

PRODUCT CATALOGUE CHILLER ECOMAX

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

AIR COOLED CHILLERS WATER COOLED CHILLERS

HYDROCIAT LW. Use. Range. Water-cooled chillers. Screw compressors CIAT shell and tubes direct expansion evaporator HPS (High Power System) equipment

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Reversible air-to-water scroll heat pumps

LSE kw. Outdoor packaged unit. Air/water chillers and heat pumps LSE PLUS

CGA CXA VGA VXA CG-PRC006-E4

LDA LDA. Air cooled water chillers with axial fans VERSIONS R410A

Inverter air to water heat pumps

HPR. Heat recovery units. from 700 to m³/h R410A HIGH EFFICIENCY WITH ENTHALPY EXCHANGER AND BUILT-IN HEAT PUMP SYSTEM

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

6-1/3 and 7-1/2 Ton Split System Air Conditioner (3 Phase) 75 to 89 MBtuh R -22 Refrigerant. Nominal Capacity BTUH

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

DXP 100 Air Cooled Condenser

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

DXP 100. Dry Cooler CERTIFY-ALL DX COOLERS

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

application guide axial condensing units

ACPSE-P Series 50Hz 410A. Rooftop Units Cooling Capacity : 26 to 1388 MBH (8 to 407 kw) Heating Capacity : 28 to 1298 MBH (8 to 380 kw)

Selection & Application guidelines. Condensing Units 50 Hz - 1, 2, 4 cylinders R22 - R134a - R404A / R507 REFRIGERATION AND AIR CONDITIONING

Reversible air-to-water heat pump HEAT PUMP HEATING (30/35 C 40/45 C)

... RTU Technical Manual. Packaged Air Conditioning Unit...

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

Air Cooled CAPACITY: TR CHILLER PRODUCT DATA BOOK

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

R4A3. Product Specifications EFFICIENT 13 SEER AIR CONDITIONER ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT

Bosch BOVA Split System Heat Pump

GPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER

RCD Air Cooled Condensing Unit (50/60 Hz)

SyScroll Air EVO NEW

CAC SERIES 12-1/2 Thru 20 Ton

Total and partial heat recovery RANGE. AQUACIAT power LD series. AQUACIAT power LDC - LDH series. AQUACIAT power ILD series

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Inverter scroll compressors VZH single and manifold

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

PHB SERIES 7-1/2 and 10 TON

OMEGA V ECHOS Water/water cooled chillers and heat pumps kw

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

WCA4**4. Product Specifications

HYDROCIAT LW R134a. Water cooled chillers USE RANGE

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

RCTM. Condensor, kw. RC Low up to 66 kw. RC Mid&High up to 1200 kw. Quick facts. General

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

CMTE. Tangential Fan Coil Series with Electronic Controlled Motor

CS Series Condensing Units

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

Air Cooled Packaged Units

N4A6. Product Specifications

Index Features and advantages... 3 General characteristics... 5 Nomenclature Technical specifications... 11

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

TEAL FCTM. Chiller with integrated Free Cooling system chillers and heat pumps, kw

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

TEH-LINE CONDENSING UNITS

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

YCUJ Millennium TM AIR COOLED CONDENSING UNIT

VTZ variable speed Reciprocating compressors

Transcription:

Compresseur scroll Refrigerant R410A SYSAQUAC Air Cooled Condensing Units Models 25 to 125 32.0 to 136.0kW

SYSAQUA Condensation 1 Key Points R410A refrigerant, Units are optimized for partial load operation, High ESEER, 2 compressors fitted in tandem for all the range with two capacity steps on sizes 25 to 45 and three capacity steps on sizes 55 to 125, with an immediate return on investment versus the inverter units, Low noise version supplied as standard, extra low noise version for the XLN units (SYSAQUAC 45-125 only), Refrigerant circuit is completely closed in a separate compartment in order to reduce noise level (sizes 25 to 40), Great accessibility to internal components for service operations, Wide operating limits, Fan speed control for low ambient operation in cooling mode down to -10 C as STD, Phase sequence monitor supplied as standard, Small footprint, allowing shipping and handling costs to be saved, units find easily a place to be installed, Suction and liquid line shut-off valve as STD, Ideal to be connected with an air handling unit. SYSAQUA Condensation SYSAQUAC 25 to 40 SYSAQUAC 45 to 55 SYSAQUAC 65 to 125

2 SYSAQUA Condensation Specifications General The new SYSAQUAC 25 to 125 have been designed and optimized to operate with R410A refrigerant fluid. They are of single refrigerant circuit type. They are available in cooling only (SYSAQUAC) version. This version consists of 11 sizes (25, 30, 35, 40, 45, 55, 65, 75, 90, 105 & 125) and covers a nominal cooling capacity range from 32 to 136 kw. All units are equipped with two scroll compressors fitted in tandem for adapting to partial system loads. A fan speed controller is also supplied as factory-fitted as STD to authorize the unit to operate in cooling mode at low ambient temperature. SYSAQUAC units can be supplied in two versions : Refrigerant circuit All units have one refrigerant circuit consisting of : scroll tandem compressors, condenser coil, as well as safety and control devices such as high pressure switch, suction and liquid line shut-off valve, filter drier, sight glass, suction receiver. A set of LP and HP gauges can be factory fitted as optional. All refrigerant components are shown in the functional diagrams illustrated in the next pages, section "Refrigerant flow diagrams". Electrical box All electrical equipment required for proper unit operation is located in a weatherproof electrical control box including : Main disconnect switch (wired and mounted). STD (Standard) version : Includes a low noise (LS) acoustical performance. Phase monitor. XLN (Extra low noise) version (SYSAQUAC 45-125 only) : Obtained by the installation of acoustic box on the compressor tandem. circuit breaker. Cabinet and structure The cabinet and structure of the unit are of heavy duty galvanized steel. All galvanized steel components are individually painted by a special painting process before the assembly of the unit. Compressors contactor with thermal relay and magneto thermal Control circuit fuse. Anti-short cycle relay. Automatic reset LP switch. Manual reset HP switch. This painting system performs a homogeneous protection to the corrosion. The painting is a polyester powder based type, coloured in RAL 7040. Fan speed controller frequency drive. The units SYSAQUAC are suitable for outdoor installation, directly on the building roof or at the ground level. contact from external control (not provided). Compressors Each unit is equipped with two scroll compressors fitted on rails and assembled together to form tandem compressors. The compressors are mounted on rubber pads in order to eliminate noise and vibration transmissions. The compressor motors have a direct start-up. Each motor is cooled by the refrigerant gas and is equipped with an overload protection. A phase sequence monitor is supplied as standard. Condenser The condenser is a finned coil constructed with seamless copper tubes mechanically expanded into aluminium fins. The condenser is largely dimensioned in order to optimize performance. The condenser can be equipped, as optional, a protective grid to prevent shocks. Condenser fans and motors Main terminal strip for tandem compressors On/Off by 230V dry Control and safety devices Each unit is complete with the following safety and control devices : Safety : Fan motor overload protection. Compressor motor overload protection. High pressure switch. Crankcase heater. Conformity with standards All SYSAQUAC units are in compliance with the following standards : Machine Directive : 2006/42/EC Low Voltage Directive : 2006/95/EC Electromagnetic Compatibility Directive : 2004/108/EC Pressure Equipment Directive : 97/23/EC Factory-installed options Each unit has one or two axial fan. Condenser protective grid. The fan motor has IP54 grade and is equipped with a thermal overload protection. Reinforced acoustic insulation (XLN version). A pressostatic type fan speed controller is delivered as factory-fitted STD. It allows the unit to operate in cooling mode at low ambient temperatures down to -10 C minimum, because it regulates the fan speed in order to maintain the condensing temperature in the compressor operating range. All fans are fitted with a protective grid on top. Coil with epoxy treatment. LP/HP gauges. Soft starter. Field-installed accessories Anti-vibration rubber pads.

SYSAQUA Condensation 3 Refrigerant Flow Diagram HP switch / Transducer / Shrader Compressors Condensor Filter drier Sight glass Shut off valve liquid line Shut off valve suction line LP switch / Shrader Suction receiver Operating Limits 55 50 Condenser inlet temperature ( C) 45 40 35 30 25 20 15 10 5 0-5 -10 Running with fan speed control STD -15-14 -13-12 -11-10 -9-8 -7-6 -5-4 -3-2 -1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Evaporating temperature ( C)

4 SYSAQUA Condensation Correction Factors Fouling factors - Condenser Fouling factor (m 2. C/kW) Capacity Power input 0.044 1.000 1.000 0.088 0.987 1.023 0.176 0.955 1.068 0.352 0.910 1.135 Altitude factors Altitude (m) Capacity Power input 0 1.000 1.000 600 0.987 1.010 1200 0.973 1.020 1800 0.958 1.030 2400 0.943 1.040

SYSAQUA Condensation 5 Physical Data SYSAQUAC 25 30 35 40 45 Cooling capacity kw 32.5 33.7 43.1 44.8 57.3 Power input kw 9.1 9.8 13.9 14.1 17.4 Total EER 100% (1) 3.57 3.44 3.10 3.18 3.29 Power supply 400V/3~+N/50Hz Startup type Direct Maximum operating current A 22.5 24.5 32 34 41 Startup current A 64 77.5 118.5 119.5 134 REFRIGERANT (units are delivered with a neutral charge of Nitrogen) Type R410A Number of refrigerant circuit 1 Indicative charge (2) kg 8.4 8.4 9.1 9.2 14 COMPRESSORS Number 2 2 2 2 2 Type Scroll Part load steps % 0/50/100 0/50/100 0/50/100 0/50/100 0/50/100 Crankcase heater W 2 x 40 2 x 70 2 x 70 2 x 70 2 x 90 COIL Number 1 1 1 1 1 Frontal surface m 2 2.4 2.4 2.8 2.8 4.2 Number of rows 2 2 2 2 2 FAN Number 1 1 1 1 1 Air flow m³/h 13000 13000 16000 16000 22500 Rotational speed rpm 900 900 650 650 860 Power input each fan W 940 940 930 930 2100 REFRIGERANT CONNECTIONS Liquid line inch 5/8" 5/8" 5/8" 5/8" 5/8" Suction line inch 1"1/8 1"1/8 1"1/8 1"1/8 1"5/8 DIMENSIONS Length mm 1000 1000 1000 1000 2180 Width mm 1000 1000 1000 1000 1160 Height mm 1983 1983 1983 1983 1986 WEIGHT Operating kg 260 270 280 280 490 ACOUSTICAL DATA Sound power level db(a) 75 75 76 76 80 (1) Air : 35 C - Evaporating temperature : +7 C. (2) Refrigerant indicative charge without considering refrigerant connection piping. Recommended added charge = 195 g/ml for liquid line 5/8". Recommended added charge = 380 g/ml for liquid line 7/8".

6 SYSAQUA Condensation Physical Data (continued) SYSAQUAC 55 65 75 90 105 125 Cooling capacity kw 64.5 72.3 79.3 103.9 119.6 136.4 Power input kw 20.2 22.5 25.3 35 38.8 47.1 Total EER 100% (1) 3.19 3.21 3.13 2.97 3.08 2.89 Power supply 400V/3~N/50Hz Startup type Direct Maximum operating current A 45 59.5 64.5 79.5 87.5 103.5 Startup current A 141 201.5 206.5 266.5 313.5 351.5 REFRIGERANT (units are delivered with a neutral charge of Nitrogen) Type R410A Number of refrigerant circuit 1 Indicative charge (2) kg 14.9 18.9 19 21.5 27 27 COMPRESSORS Number 2 2 2 2 2 2 Type Scroll Part load steps % 0/43/57/100 0/40/60/100 0/45/55/100 0/45/55/100 0/38/62/100 0/33/67/100 Crankcase heater W 2 x 90 2 x 90 2 x 90 90/120 90/140 90/140 COIL(S) Number 1 2 2 2 2 2 Frontal surface m 2 4.2 5.55 5.55 6.4 6.4 6.4 Number of rows 2 2 2 2 3 3 FAN(S) Number 1 2 2 2 2 2 Air flow m³/h 22500 15000 15000 21000 21000 21000 Rotational speed rpm 900 650 650 860 860 860 Power input each fan W 2100 930 930 2100 2100 2100 REFRIGERANT CONNECTIONS Liquid line inch 5/8" 5/8" 5/8" 7/8" 7/8" 7/8" Suction line inch 1"5/8 1"5/8 1"5/8 1"5/8 1"5/8 1"5/8 DIMENSIONS Length mm 2180 2180 2180 2180 2180 2180 Width mm 1160 1160 1160 1160 1160 1160 Height mm 1986 1986 1986 2286 2286 2286 WEIGHT Operating kg 490 560 560 740 850 870 ACOUSTICAL DATA Sound power level db(a) 79 79 79 83 83 83 (1) Air : 35 C - Evaporating temperature : +7 C. (2) Refrigerant indicative charge without considering refrigerant connection piping. Recommended added charge = 195 g/ml for liquid line 5/8". Recommended added charge = 380 g/ml for liquid line 7/8".

SYSAQUA Condensation 7 Electrical Data Sizes 25 30 35 40 45 55 65 75 90 105 125 Power supply 400V / 3~N / 50Hz Maximum current A 22.5 24.5 32 34 41 45 59.5 64.5 79.5 87.5 103.5 Fuse rating am A 25 25 32 40 50 50 63 80 80 100 125 Total startup current A 64 77.5 118.5 119.5 134 141 201.5 206.5 266.5 313.5 351.5 Acoustical Data Sound power level Lw-dB(A) Sizes SYSAQUAC Frequency in octave band (Hz) 125 250 500 1000 2000 4000 Lw db(a) global STD version 25 49.9 59.4 66.8 70 70.2 67 75 46.8 30 49.9 59.4 66.8 70 70.2 67 75 46.8 35 50.9 60.4 66.8 71 71.2 68 76 47.8 40 50.9 60.4 66.8 71 71.2 68 76 47.8 45 55.9 65.4 73.8 76 75.2 70 80 51.8 55 55.9 65.4 73.8 76 75.2 70 80 51.8 65 55.9 65.4 73.8 76 75.2 70 80 51.8 75 55.9 65.4 73.8 76 75.2 70 80 51.8 90 59.9 68.4 74.8 78 79.2 73 83 54.8 105 59.9 68.4 74.8 78 79.2 73 83 54.8 125 59.9 68.4 74.8 78 79.2 73 83 54.8 Lp db(a) 10 m

8 SYSAQUA Condensation Performance Data - SYSAQUAC 25 to 125 - R410A Sizes SYSAQUAC ET ( C) Condenser air inlet temperature ( C) 20 25 30 35 40 45 47 Cooling capacity Power input Cooling capacity Power input Cooling capacity Power input Cooling capacity Power input Cooling capacity Power input Cooling capacity Power input Cooling capacity 1 28.5 7.1 27.2 7.4 25.7 8.7 23.2 8.3 20.7 8.7 18.2 9.0 17.0 9.1 3 31.6 7.4 30.3 7.6 28.8 8.3 26.3 8.6 23.8 9.0 21.3 9.2 20.1 9.3 25 5 34.7 7.6 33.4 7.9 31.9 9.2 29.4 8.8 26.9 9.2 24.4 9.4 23.2 9.6 7 37.7 7.8 36.4 8.1 34.9 9.4 32.4 9.1 29.9 9.4 27.4 9.7 26.2 9.8 9 40.8 8.1 39.5 8.3 38.0 9.7 35.5 9.3 33.0 9.7 30.5 9.9 29.3 10.1 12 45.4 8.4 44.1 8.7 42.6 10.0 40.1 9.7 37.6 10.0 35.1 10.3 33.9 10.4 1 29.3 7.5 28.2 8.0 26.6 8.4 24.5 9.0 22.1 9.3 19.3 9.7 18.2 9.9 3 32.4 7.7 31.2 8.2 29.7 8.7 27.5 9.3 25.2 9.5 22.4 9.9 21.2 10.1 30 5 35.5 8.0 34.3 8.4 32.7 8.9 30.6 9.5 28.3 9.8 25.4 10.2 24.3 10.4 7 38.5 8.2 37.4 8.7 35.8 9.1 33.7 9.8 31.3 10.0 28.5 10.4 27.3 10.6 9 41.6 8.4 40.4 8.9 38.9 9.4 36.7 10.0 34.4 10.3 31.6 10.7 30.4 10.9 12 46.2 8.8 45.0 9.3 43.4 9.7 41.3 10.4 39.0 10.6 36.1 11.0 35.0 11.2 1 38.8 10.4 37.7 11.2 36.1 14.1 33.9 13.2 31.7 14.1 28.7 15.6 27.6 16.3 3 41.9 10.6 40.7 11.4 39.2 12.3 37.0 13.4 34.7 14.3 31.8 15.8 30.7 16.5 35 5 45.0 10.8 43.8 11.6 42.2 14.6 40.0 13.7 37.8 14.6 34.8 16.0 33.8 16.8 7 48.0 11.1 46.8 11.9 45.3 14.8 43.1 13.9 40.8 14.8 37.9 16.3 36.8 17.0 9 51.1 11.3 49.9 12.1 48.3 15.1 46.2 14.2 43.9 15.1 41.0 16.5 39.9 17.2 12 55.7 11.7 54.5 12.5 52.9 15.4 50.8 14.5 48.5 15.4 45.5 16.9 44.5 17.6 1 40.5 10.5 39.4 11.3 37.8 12.3 35.6 13.4 33.3 14.6 30.4 15.7 29.2 16.3 3 43.6 10.8 42.4 11.6 40.9 12.5 38.7 13.6 36.3 14.8 33.5 15.9 32.3 16.6 5 46.7 11.0 45.5 11.8 44.0 12.7 41.7 13.8 39.4 15.0 36.5 16.1 35.3 16.8 40 7 49.7 11.2 48.5 12.1 47.0 13.0 44.8 14.1 42.4 15.3 39.6 16.4 38.4 17.1 9 52.8 11.5 51.6 12.3 50.1 13.2 47.9 14.3 45.5 15.5 42.7 16.6 41.5 17.3 12 57.4 11.8 56.2 12.7 54.7 13.6 52.5 14.7 50.1 15.9 47.2 17.0 46.1 17.7 14 60.4 12.1 59.2 12.9 57.7 13.8 55.6 14.9 53.3 16.1 50.5 17.2 49.4 17.8 1 47.8 13.6 46.5 14.5 44.9 15.4 42.8 16.5 40.5 17.6 37.6 18.8 36.4 19.4 3 52.6 14.0 51.4 14.8 49.8 15.7 47.6 16.8 45.3 17.9 42.5 19.1 41.2 19.7 5 57.4 14.3 56.2 15.1 54.6 16.0 52.5 17.1 50.2 19.5 47.3 19.5 46.1 20.0 45 7 62.3 14.6 61.1 15.4 59.5 16.3 57.3 17.4 55.0 19.8 52.2 19.8 50.9 20.3 9 67.1 14.9 65.9 15.7 64.3 16.6 62.2 17.7 59.9 20.1 57.0 20.1 55.8 20.6 12 74.4 15.3 73.2 16.2 71.6 17.1 69.4 18.2 67.1 20.5 64.3 20.5 63.0 21.1 14 79.6 15.7 78.4 16.5 76.8 17.4 74.8 18.5 72.5 20.8 69.7 20.8 68.5 21.3 1 54.9 16.4 53.7 17.3 52.1 18.2 49.9 19.3 47.6 20.4 44.8 21.6 43.5 22.2 3 59.7 16.7 58.5 17.6 56.9 18.5 54.8 19.6 52.5 20.7 49.6 21.9 48.4 22.5 5 64.6 17.0 63.4 17.9 61.8 18.8 59.6 19.9 57.3 21.0 54.5 22.2 53.2 22.8 55 7 69.4 17.4 68.2 18.2 66.6 19.1 64.5 20.2 62.2 21.3 59.3 22.6 58.1 23.1 9 74.3 17.7 73.1 18.5 71.4 19.4 69.3 20.5 67.0 21.6 64.2 22.9 62.9 23.4 12 81.5 18.1 80.3 19.0 78.7 19.9 76.6 21.0 74.3 22.1 71.4 23.3 70.2 23.9 14 86.5 18.4 85.3 19.2 83.8 20.2 81.7 21.2 79.4 22.3 76.7 23.6 75.5 24.1 1 62.8 18.7 61.5 19.5 59.9 20.5 57.8 21.6 55.5 22.7 52.6 23.9 51.4 24.4 3 67.6 19.0 66.4 19.9 64.8 20.8 62.6 21.9 60.3 23.0 57.5 24.2 56.2 24.7 5 72.4 19.3 71.2 20.2 69.6 21.1 67.5 22.2 65.2 23.3 62.3 24.5 61.1 25.1 65 7 77.3 19.6 76.1 20.5 74.5 21.4 72.3 22.5 70.0 23.6 67.2 24.8 65.9 25.4 9 82.1 19.9 80.9 20.8 79.3 21.7 77.2 22.8 74.8 23.9 72.0 25.1 70.8 25.7 12 89.4 20.4 88.2 21.2 86.6 22.2 84.4 23.3 82.1 24.4 79.3 25.6 78.0 26.1 14 94.2 20.7 93.0 21.5 91.4 22.5 89.3 23.6 87.0 24.7 84.1 25.9 82.9 26.4 1 69.0 21.2 67.8 22.0 66.2 22.9 64.0 24.0 61.7 25.1 58.9 26.4 57.6 26.9 3 74.1 21.6 72.9 22.4 71.2 23.4 69.1 24.5 66.8 25.5 64.0 26.8 62.7 27.3 5 79.1 22.0 77.9 22.9 76.3 23.8 74.2 24.9 71.9 26.0 69.0 27.2 67.8 27.8 75 7 84.2 22.5 83.0 23.3 81.4 24.3 79.3 25.3 76.9 26.4 74.1 27.7 72.9 28.2 9 89.3 22.9 88.1 23.8 86.5 24.7 84.3 25.8 82.0 26.9 79.2 28.1 77.9 28.7 12 96.9 23.6 95.7 24.4 94.1 25.4 92.0 26.5 89.6 27.5 86.8 28.8 85.6 29.3 14 102.0 24.0 100.8 24.9 99.2 25.8 97.0 26.9 94.7 28.0 91.9 29.2 90.6 29.8 1 93.6 30.9 92.4 31.7 90.8 32.6 88.6 33.7 86.3 34.8 83.5 36.1 82.2 36.6 3 98.7 31.3 97.5 32.1 95.8 33.1 93.7 34.2 91.4 35.3 88.6 36.5 87.3 37.0 5 103.8 31.7 102.5 32.6 100.9 33.5 98.8 34.6 96.5 35.7 93.6 36.9 92.4 37.5 90 7 108.8 32.2 107.6 33.0 106.0 34.0 103.9 35.0 101.6 36.1 98.7 37.4 97.5 37.9 9 113.9 32.6 112.7 33.5 111.1 34.4 109.0 35.5 106.6 36.6 103.8 37.8 102.6 38.4 12 121.5 33.3 120.3 34.1 118.7 35.1 116.6 36.2 114.3 37.3 111.4 38.5 110.2 39.0 14 126.6 33.7 125.4 34.6 123.8 35.5 121.7 36.6 119.3 37.7 116.5 38.9 115.3 39.5 1 109.3 34.6 108.1 35.4 106.5 36.3 104.4 37.4 102.1 38.5 99.2 39.8 98.0 40.3 3 114.4 35.0 113.2 35.9 111.6 36.8 109.5 37.9 107.1 39.0 104.3 40.2 103.1 40.8 5 119.5 35.5 118.3 36.3 116.7 37.2 114.5 38.3 112.2 39.4 109.4 40.7 108.1 41.2 105 7 124.6 35.9 123.4 36.7 121.8 37.7 119.6 38.8 117.3 39.9 114.5 41.1 113.2 41.6 9 129.7 36.4 128.5 37.2 126.8 38.1 124.7 39.2 122.4 40.3 119.6 41.6 118.3 42.1 12 137.3 37.0 136.1 37.9 134.5 38.8 132.3 39.9 130.0 41.0 127.2 42.2 125.9 42.8 14 142.4 37.5 141.2 38.3 139.5 39.2 137.4 40.3 135.1 41.4 132.3 42.7 131.0 43.2 1 126.1 42.9 124.9 43.7 123.3 44.7 121.1 45.8 118.8 46.8 116.0 48.1 114.7 48.6 3 131.2 43.3 130.0 44.2 128.3 45.1 126.2 46.2 123.9 47.3 121.1 48.5 119.8 49.1 5 136.3 43.8 135.0 44.6 133.4 45.5 131.3 46.6 129.0 47.7 126.1 49.0 124.9 49.5 125 7 141.3 44.2 140.1 45.1 138.5 46.0 136.4 47.1 134.1 48.2 131.2 49.4 130.0 50.0 9 146.4 44.7 145.2 45.5 143.6 46.4 141.5 47.5 139.1 48.6 136.3 49.9 135.1 50.4 12 154.0 45.3 152.8 46.2 151.2 47.1 149.1 48.2 146.8 49.3 143.9 50.5 142.7 51.1 14 159.1 45.8 157.9 46.6 156.3 47.5 154.2 48.6 151.8 49.7 149.0 51.0 147.8 51.5 ET : Evaporating temperature. Power input

SYSAQUA Condensation 9 Typical Installation Diagrams Outdoor unit at higher level SYSAQUAC L 30 m maxi. Install a siphon on the gas pipe every 5 m Air Handling Unit H+ 25 m maxi. Outdoor unit at lower level Air Handling Unit L 30 m maxi. The pipe links should have a minimum slope of 1/250 towards the outdoor unit SYSAQUAC H- 15 m maxi.

10 SYSAQUA Condensation Dimensions (mm) SYSAQUAC 25 to 40 Rear view Front view 1983 1000 Top view Side view A 1000 DETAIL A Manometer HP (Optional) Manometer BP (Optional) Suction line Ø1"1/8 190 127 146 156 Liquid line Ø5/8"

SYSAQUA Condensation 11 Dimensions (mm) (continued) SYSAQUAC 45 to 55 Side view Front view 1986 A Side view Top view 2180 1160 Manometer HP (Optional) Manometer BP (Optional) DETAIL A Suction line Ø1"5/8 Liquid line Ø5/8 174 245 764 785

12 SYSAQUA Condensation Dimensions (mm) SYSAQUAC 65 to 75 Side view Front view 1987 A Side view Top view 2180 1160 Manometer HP (Optional) DETAIL A Manometer BP (Optional) Suction line Ø1"5/8 Liquid line Ø5/8 174 245 764 785

SYSAQUA Condensation 13 Dimensions (mm) (continued) SYSAQUAC 90 to 125 Side view Front view 2286 Side view Top view 2180 A 1160 Manometer HP (Optional) Manometer BP (Optional) DETAIL A Suction line 1"5/8 Liquid line 7/8" 169 245 764 781

14 SYSAQUA Condensation Space Requirements (mm) SYSAQUAC 25 to 55 SYSAQUAC 65 to 125

Notes SYSAQUA Condensation 15

16 SYSAQUA Condensation Notes

Systemair AC SAS route de Verneuil, 27570 Tillières-sur- Avre Tél. 02 32 60 61 00 Fax 02 32 32 55 13 www.systemair.fr Systemair EDM AQAC-S-1GB/01.15 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. january 2015