USER S MANUAL VFD SERIES. Variable-frequency drives for 3-phase and single-phase AC motors

Similar documents
USER S MANUAL

USER S MANUAL VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM

USER S MANUAL. Variable-frequency drives for 3-phase and single-phase AC motors

USER S MANUAL. Variable-frequency drive for 3-phase and single-phase AC motors

User s Manual MMVFD SERIES MODEL: MMVFD06-D230AC. Variable-frequency drives for 3-phase AC motors

17429X.00 SERIES MODELS:

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

VFD Series USER MANUAL VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC.

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

PWP Series USER MANUAL PWP100-2 PWP100-2-QDT PWP100-5 PWP PWP101-2 PWP101-5 PWP

An American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.

MM23xx1C Series USER MANUAL MM23001C MM23001C-Q MM23011C MM23011C-Q MM23101C MM23111C MM23201C MM23211C MM23401C MM23411C.

Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives

MM03-PCM MM10-PCM. User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

Excel [XL] Series USER S MANUAL

MHS Series USER MANUAL MHS MHS MHS MHS443-10

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

CONTROL FEATURES AVAILABLE OPTIONS

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol DC Motor Speed Control

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

KBVF Adjustable Frequency Drive

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

PowerOhm Installation Manual for BM R Series Braking Modules

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Filtered PWM Speed Control for Permanent Magnet DC Motors

PowerOhm Installation Manual for LG ATV Series Braking Modules

RG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors


Installation and Operation Manual. *See page 6 for CE Information

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

BC141, BC142, BC142-5 & BC142-6 DC Control

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

DORNER Conveyor Speed Control

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

KBAC SERIES Adjustable Frequency Drives for 3-Phase AC Motors NEMA-4X / IP-65

High Frequency SineWave Guardian TM

Installation, Operation and Maintenance Manual

INSTALLATION AND OPERATION MANUAL KBAC SERIES. Adjustable Frequency Drive for 3-Phase AC Motors NEMA 4X / IP65

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

DC Variable Speed Drive Panel

Installation & Operation Manual

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Installation, Operation and Maintenance Manual

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

Installation and Operating Manual

5001TCP SPEED CONTROLLER

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

Installation & Operation Manual DA SERIES

*** A Complete Line of Motor Drives

Installation and Operation Manual

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

Series 5 Inverter NEMA 4X, IP65

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

Boston Gear Ratiotrol DC Motor Speed Control

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

Series 5 Inverter NEMA 4X, IP-65 Installation and Operating Manual

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

CABINET REEL OPERATING INSTRUCTIONS

G203V / G213V MANUAL STEP MOTOR DRIVE

PowerOhm Installation Manual for BM R Series Braking Modules

STR3. Step Motor Drive. User Manual

MaxPak Plus Analog DC V S Drive

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

User's Manual O

TRIPS AND FAULT FINDING

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

Boston Gear Ratiotrol

CDBR-B. Instruction Manual. Dynamic Braking Unit. March 2013 Part Number: R4 Copyright 2013 Magnetek

Dayton DC Motor Control

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

G213V STEP MOTOR DRIVE REV 7: March 25, 2011

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

5001TCP SPEED CONTROLLER

Transcription:

USER S MANUAL VFD SERIES Variable-frequency drives for 3-phase and single-phase AC motors VFD01-230AC VFD01-D230AC VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC VFD01-230AC-PCM VFD01-D230AC-PCM VFD02-115AC-PCM VFD02-230AC-PCM VFD02-D230AC-PCM VFD04-115AC-PCM VFD04-230AC-PCM VFD04-D230AC-PCM

Copyright 2002 by Minarik Corporation All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from Minarik Corporation. The information and technical data in this manual are subject to change without notice. Minarik Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Corporation and its Divisions assume no responsibility for any errors that may appear in this manual and make no commitment to update or to keep current the information in this manual. MVD082602 Printed in the United States of America.

i Safety Warnings SHOCK HAZARD AVOID HEAT KEE DR OID ATION This symbol denotes an important safety tip or warning. Please read these instructions carefully before performing any of the procedures contained in this manual. DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED. Have a qualified electrical technician install, adjust and service this equipment. Follow the National Electrical Code and all other applicable electrical and safety codes, including the provisions of the Occupational Safety and Health Act (OSHA), when installing equipment. Reduce the chance of an electrical fire, shock, or explosion by using proper grounding, over-current protection, thermal protection, and enclosure. Follow sound maintenance procedures. It is possible for a drive to run at full speed as a result of a component failure. Minarik strongly recommends the installation of a master switch in the main power input to stop the drive in an emergency. Circuit potentials are at 115 VAC or 230 VAC above earth ground. Avoid direct contact with the printed circuit board or with circuit elements to prevent the risk of serious injury or fatality. Use a non-metallic screwdiver for adjusting the calibration trimpots. Use approved personal protective equipment and insulated tools if working on this drive with power applied.

ii General Information The Minarik Variable Frequency Drive (VFD) Series are solid-state, variable-frequency AC motor drives. The VFD utilizes a 115 or 230 VAC, 50/60 Hz, single-phase input, and is factory calibrated for an output of 0 to 60 Hz. They will operate any 1 HP or smaller, 115 or 208/230-volt, threephase-ac-induction, single-phase permanent split capacitor motor (see page v) and can be user calibrated for 0 through 120 Hz output. Although VFD inverters can operate over their full speed range, most motors will operate with constant torque over a 10:1 speed range, 6 Hz to 60 Hz, and constant horsepower above 60 Hz. (Inverter-duty motors may operate satisfactorily over a 20:1 speed range.) Some motors can be satisfactorily operated at speeds as low as 50 rpm (speed range 50:1). Below 50 rpm, some motors may show signs of stepping or cogging, and may run warmer. *Although the VFD will allow a minimum of 0 Hz, the actual minimum frequency is dependent on motor type and load. The motor may need to be derated for low-frequency (30 Hz and lower) operation. Please consult the motor manufacturer.

General Information iii Many 3-phase inverter manufacturers claim that they can run single-phase motors effectively. This is normally accomplished by wiring only 2 phases; however, this method may cause instabilities due to the lack of feedback from one of the motor connections. Furthermore, motor torque will be reduced considerably because the phases are 120 apart. Although the VFD uses this method of connection, its fundamental design enables it to operate efficiently under these conditions. The VFD series features solid-state reversing with adjustable acceleration and deceleration. The VFD may also interface with motor thermal protection through the enable circuit.

iv General Information VFD SERIES FEATURES & BENEFITS SOLID-STATE CIRCUITRY SOLID-STATE REVERSING ADJUSTABLE CARRIER FREQUENCY (4 khz - 16 khz) MULTIPLE MOTOR OPERATION THREE-PHASE AND SINGLE-PHASE MOTOR CONTROL LED INDICATORS POWER (green) FAULT (red) U V W TORQUE (yellow) TB501 TQ TH501 C501 L2 ADJUSTABLE CALIBRATION TRIMPOTS DECEL 501:INPUT RANGE 1-2:VOLTAGE JMP502:INPUT TYPE C502 J501 115V ACCEL MAX E2 E1 S1 S3 D TB501 230V BOOST L1 TQ LIMIT ACCEPTS A 0-5 VDC, 0-10 VDC, or 4-20 ma NON-ISOLATED SIGNAL OPTIONAL ISOLATION BOARD DOUBLES THE OUTPUT VOLTAGE TO THE AC MOTOR WHEN 115 IS APPLIED DOUBLER VERSIONS optional ZERO SET on isolation board Figure 1. VFD Series Features & Benefits

v Important Information Warning Caution should be taken when operating fan-cooled motors at low speeds because their fans may not move sufficient air to properly cool the motor. Minarik recommends inverter-duty motors when the speed range is beyond 10:1. In addition to standard 3-phase induction motors, the following motor types may be used with the VFD: Permanent split capacitor (PSC) Shaded pole AC synchronous The following motor types MAY NOT be used: Split phase Capacitor start Repulsion induction Series Universal AC/DC Any motor with starting switch (centrifugal or relay) and/or separate starting winding.

vi Contents Safety Warnings i General Information ii Important Information v Specifications 1 Dimensions 2 Installation 10 - PCM Isolation Option Board Mounting............................10 Mounting....................................................15 Wiring......................................................17 Shielding guidelines.........................................18 Heat sinking.................................................19 Fusing.....................................................20 Speed adjust potentiometer......................................21 Connections.................................................22 Power and fuse connections..................................22 Motor connections (all VFD-series controls).......................27 Speed Adjust Potentiometer Connections.........................31 Voltage Follower Connections.................................32 Signal and Optional Switch Connections.........................33 Voltage or Current Follower (-PCM models).......................35 Operation 37 Voltage Doubler...............................................38 Startup.....................................................39 To reverse motor direction:....................................40 Starting and stopping methods...................................41 To coast the motor to a stop...................................41 Thermal protection of the motor................................41 Line starting and line stopping..................................43

Contents vii Calibration 44 Calibration Procedure Setup for 60 Hz Motors:.......................46 MAXIMUM SPEED (MAX SPD)................................46 TORQUE LIMIT (TQ LIMIT)...................................47 ACCELERATION (ACCEL)...................................48 DECELERATION (DECEL)...................................48 BOOST..................................................49 Calibration Procedure Conclusion..............................50 Application Notes 51 Independent adjustable speeds with DIR switch......................51 RUN/JOG switch.............................................52 Single speed potentiometer control of multiple motors..................53 Quick Reversing..............................................54 Troubleshooting 55 Before troubleshooting.........................................55 Diagnostic LEDs..............................................57 POWER LED..............................................57 FAULT LED...............................................57 TQ LIMIT LED.............................................58 Optional C510 Capacitor Kit (p/n: 202-0108).........................63 Replacement Parts............................................65 Unconditional Warranty 67 Tables Table 1. Line Fusing Chart..................................................20 Table 2. Replacement Parts.................................................65

viii Illustrations Figure 1. VFD Series Features & Benefits........................................iv Figure 2. VFD01-230AC, VFD02-115AC, VFD02-230AC Dimensions....................2 Figure 3. VFD04-115AC and VFD04-230AC Dimensions.............................3 Figure 4. VFD01-230AC-PCM, VFD02-115AC-PCM and VFD02-230AC-PCM Dimensions....................................4 Figure 5. VFD04-115AC-PCM and VFD04-230AC-PCM Dimensions....................5 Figure 6. VFD01-D230AC & VFD02-D230AC Dimensions............................6 Figure 7. VFD04-D230AC Dimensions...........................................7 Figure 8. VFD01-D230AC-PCM and VFD02-D230AC-PCM Dimensions..................8 Figure 9. VFD04-D230AC-PCM Dimensions......................................9 Figure 10. VFD Series Drive with PCM adder board & -PCM adder kit..................11 Figure 11. Speed Adjust Potentiometer.........................................21 Figure 12. AC Line and Fuse Connections for VFDxx-115AC and VFDxx-230AC Series Drives.........................................23 Figure 13. AC Line and Fuse Connections for VFDxx-D230AC Series Drives (Voltage Doubler Mode).............................................25 Figure 14. AC Line and Fuse Connections for VFDxx-D230AC Series Drives (No Voltage Doubler)...............................................26 Figure 15. Motor Connections for Single-Phase Operation (Motor With Pre-Wired Capacitor).....................................28 Figure 16. Motor Connections for Single-Phase Operation (Configured for use with DIRECTION switch).............................29 Figure 17. Motor Connections for Three-Phase Motors..............................30 Figure 18. Speed Adjust Potentiometer Connections to TB501........................31 Figure 19. Voltage Follower connections........................................32 Figure 20. Enable / Disable Switch connections to TB501...........................33 Figure 21. Signal and Optional Switch Connections................................34 Figure 22. -PCM jumper locations and terminal connections..........................36 Figure 23. Thermal Overload Switch with Optional Enable / Disable Switch..............42 Figure 24. VFD Series Calibration Trimpot Layout.................................45 Figure 25. Independent Adjustable Speeds......................................51 Figure 26. RUN/JOG Switch.................................................52 Figure 27. Single Speed Potentiometer Control of Multiple Motors.....................53 Figure 28. VFD Quick Reversing..............................................54 Figure 29. VFD Series diagnostic LED locations...................................58 Figure 30. Carrier frequency capacitor location....................................64

1 Specifications 1-Phase 1 or 3-Phase Max Continuous AC Input Output Max Output Amps Drive (VAC) (VAC) HP Current (AC) In VFD01-230AC 230 230 ¼ 1.2 3 VFD01-D230AC *115 / 230 230 ¼ 1.2 7 / 3 VFD02-115AC 115 115 ¼ 2.4 7 VFD02-230AC 230 230 ½ 2.4 7 VFD02-D230AC *115 / 230 230 ½ 2.4 10 / 7 VFD04-115AC 115 115 ½ 4.0 10 VFD04-230AC 230 230 1 4.0 10 VFD04-D230AC *115 / 230 230 1 4.0 15 / 10 * Connect only 115 VAC line input to the 115 VAC terminals. Application of 230 VAC line input when set for 115 VAC will result in severe damage to the motor and drive, and possible explosion and injury. Derate current by 2% per degree if the operating temperature is above 40 C. Under no circumstances may the ambient temperature exceed 55 C. AC Voltage Input Range VFDxx-115AC drives VFDxx-230AC drives VFDxx-D230AC drives Standard Carrier Frequency Output Frequency Range Adjustable Maximum Output Frequency Range Acceleration Time Range Deceleration Time Range 115 VAC ± 10%, 50/60 Hz single phase 230 VAC ± 10%, 50/60 Hz single phase 115/230 VAC ± 10%, 50/60 Hz single phase Analog Input Voltage Range (signal must be isolated; S1 [-] to S2 [+]) Input Impedance, S1 to S2 Vibration Weight Ambient Operating Temperature Range 16 KHz 0 120 Hz 30 120 Hz 1 12 seconds 1 12 seconds 0 5VDC** ~ 100K ohms 0.5G max (20 50 Hz) 0.1G max (> 50 Hz) 1.2 lb 10 40 C ** An isolation board option that allows for a non-isolated 0-5 VDC, 0-10 VDC, or 4-20 ma input signal is available (-PCM option). The option board is installed directly above the main board, maintaining the same footprint and dimensions. Call the factory for more information regarding the -PCM option.

C510 2.12 [54] 0.96 [24] H U 4.30 [109] 3.80 [97] V W Dimensions 2 TB501 E2 E1 S1 S2 S3 D 3.70 [94] 2.72 [69] J501 DECEL TQ ACCEL JMP501 BOOST TQ LIMIT FAULT J503 POWER AC AC - IC502 0.97 [25] L2 J502 L1 ALL DIMENSIONS IN INCHES [MILLIMETERS] TOTAL HEIGHT (H) (TOP OF CAP TO BOTTOM OF CHASSIS) VFD01-230AC 2.03 [51.6] VFD02-115AC 2.68 [68.1] VFD02-230AC 2.48 [ 63.0] Figure 2. VFD01-230AC, VFD02-115AC, VFD02-230AC Dimensions

C510 IC502 AC AC - 1.00 [25] U Y W 4.40 [112] E2 E1 S1 S2 S3 D DECEL BOOST T FAULT J503 3.00 [72] POWER L2 L1 J502 0.7 [18] 0.13 [3] 3.68 [93.5] 6.30 [160] 6.90 [175] ALL DIMENSIONS IN INCHES [MILLIMETERS] Dimensions Figure 3. VFD04-115AC and VFD04-230AC Dimensions 3

D 1 2 3 4 Dimensions 4.30 [109] 3.80 [97] U V W TB501 TQ TQ LIMIT 3.70 [94] FAULT J503 2.72 [69] JMP501:INPUT RANGE 1:0-5VDC 2:0-10VDC 3:4-20MA E1 S1 S2 TB501 JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT AC AC - L2 L1 J502 0.97 [25] H E2 E1 S1 S2 S3 D 2.12 [54] 0.96 [24] TOTAL HEIGHT (H) (TOP OF CAP TO BOTTOM OF CHASSIS) VFD01-230AC -PCM 2.03 [51.6] VFD02-115AC-PCM 2.68 [68.1] VFD02-230AC-PCM 2.48 [63.0] ALL DIMENSIONS IN INCHES [MILLIMETERS] Figure 4. VFD01-230AC-PCM, VFD02-115AC-PCM and VFD02-230AC-PCM Dimensions

TB501 1 2 3 E2 E1 S2 S3 D AC AC - Dimensions 5 U Y W 4.40 [112] DECEL 3.00 [72] FAULT J503 3:4-20MA JMP501:INPUT RANGE 1:0-5VDC JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT POWER L2 TB501 L1 J502 0.70 [18] 6.30 [160] 6.90 [175] ALL DIMENSIONS IN INCHES [MILLIMETERS] E2 E1 S1 S2 S3 D 3.68 [93.5] 1.00 [25] 0.12 [3] Figure 5. VFD04-115AC-PCM and VFD04-230AC-PCM Dimensions

C510 H 6 2.12 [54] 4.30 [109] 0.96 [24] U 3.80 [97] V W Dimensions TB501 TH501 E2 E1 S1 S2 S3 D 3.70 [94] 2.72 [69] J501 JMP501 DECEL TQ ACCEL TQ C502 C501 J501 L2 IC502 115V 0.97 [25] 230V L1 ALL DIMENSIONS IN INCHES [MILLIMETERS] VFD01-D230AC VFD02-D230AC TOTAL HEIGHT (TOP OF CAP TO BOTTOM OF CHASSIS) 2.56 [65.0] 3.02 [76.7] Figure 6. VFD01-D230AC & VFD02-D230AC Dimensions

TB501 C510 IC502 C502 TH501 C501 J501 1.00 [25] U Y W 4.40 [112] E2 E1 S1 S2 S3 D TQ L2 3.00 [72] 230V L1 0.70 [18] 0.13 [3] 6.30 [160] 4.45 [113] 6.90 [175] ALL DIMENSIONS IN INCHES [MILLIMETERS] Dimensions Figure 7. VFD04-D230AC Dimensions 7

2 3 TB501 D C502 TH501 C501 J501 8 Dimensions 4.30 [109] 3.80 [97] U V W DECEL TQ L2 ACCEL 3.70 [94] JMP502 JMP501:INPUT RANGE 1:0-5VDC 2:0-10VDC 3:4-20MA E2 E1 S1 S2 S3 TB501 JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT 115V 230V 0.97 [25] 2.72 [69] L1 E2 E1 S1 S2 S3 D H 2.00 [51] 0.96 [24] TOTAL HEIGHT (TOP OF CAP TO BOTTOM OF CHASSIS) VFD01-D230AC-PCM 2.56 [65.0] VFD02-D230AC-PCM 3.02 [76.7] ALL DIMENSIONS IN INCHES [MILLIMETERS] Figure 8. VFD01-D230AC-PCM and VFD02-D230AC-PCM Dimensions

1 2 3 C502 TH501 C501 J501 Dimensions 9 6.30 [160] U Y W 4.40 [112] TQ L2 3.00 [76] JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT 230V L1 0.70 [18] 6.90 [175] ALL DIMENSIONS IN INCHES [MILLIMETERS] E2 E1 S1 S2 S3 D 4.45 [113] 1.00 [25] Figure 9. VFD04-D230AC-PCM Dimensions

10 Installation - PCM Isolation Option Board Mounting The VFD Series - PCM Adder Board accepts a 0-5 VDC, 0-10 VDC, or 4-20 ma signal and outputs an isolated 0-5 VDC signal without requiring additional panel space. It mounts directly over the main AC board (bottom board) thus maintaining the same footprint. Step-by-step information for mounting the -PCM Adder Board to a VFD Series drive is shown on pages 12-14. Figure 10 (page 11) shows a VFD Series drive with the -PCM adder board installed on the unit and the parts supplied in the -PCM adder kit.

J501 D TB501 D C502 TH501 C501 J501 Installation 11 MAIN AC BOARD (BOTTOM BOARD) U Y W L2 PCM ADDER BOARD JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT 230V L1 PARTS SUPPLIED IN THIS KIT PCM ADDER BOARD (1) PCB STANDOFF (2) JUMPER (1) JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT 1:0-5VDC 2:0-10VDC 3:4-20M TB501 S3 S2 S1 E1 6-PIN HEADER (1) SHOULDER WASHER (1) 0.578" NYLON SPACER (1) 6-32 x 1 5/16" PHILLIPS SCREW (1) Required Tools: Phillips Screwdriver Figure 10. VFD Series Drive with PCM adder board & -PCM adder kit

12 Installation U V W TB501 H501 L2 C501 C502 J501 115V C510 S T E P # 1 230V L1 USING A PHILLIPS SCREWDRIVER REMOVE SCREW AND PLASTIC CAP FROM BOTTOM BOARD AND DISCARD. NOTE: DO NOT REMOVE THE SHOULDER WASHER FROM THE BOTTOM BOARD. U V W TB501 TH501 DECEL L2 TQ C501 S T E P # 2 PLACE THE JUMPER (NOTCH SIDE UP) ON JMP501 OF THE BOTTOM BOARD. IC502 C502 J501 115V 230V L1

J501 T TB501 C510 C510 JMP501 2 IC502 C502 C502 TH501 TH501 J501 C501 C501 J501 J501 Installation 13 U V W L2 TQ S T E P # 3 INSTALL TWO (2) PLASTIC STANDOFFS ONTO BOTTOM BOARD 115V 230V L1 U V W L2 S T E P # 4 TQ SNAP THE SHORT SIDE OF THE 6-PIN HEADER INTO J501 LOCATED ON THE BOTTOM BOARD J501 115V 230V L1 VIEW EW JMP502:INPUT TYPE 1-2:VOLTAGE 2:0-10VDC 3:4-20MA JMP502:INPUT TYPE 1-2:VOLTAGE S T E P # 5 INSERT THE SHOULDER WASHER (included with the kit) THROUGH THE TOP SIDE OF THE PCM ADDER BOARD. SIDE VIEW SIDE VIEW S T E P # 6 ATTACH THE 0.578" SPACER TO THE BOTTOM SIDE OF THE SHOULDER WASHER AS SHOWN.

D TB501 J501 C510 JMP501 D IC502 C502 C502 TH501 TH501 C501 C501 J501 J501 14 Installation J501 JMP501:INPUT RA 1:0-5VD 2:0-10V 3:4-20M JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT U V W TB501 DECEL L2 S T E P # 7 POSITION THE PCM ADDER BOARD OVER THE BOTTOM BOARD AS SHOWN. 115V NOTE: First align the bottom holes of J501 (on the PCM adder board) with the 6 pin header installed on the bottom board. The PCM adder board will snap into place at J501 and the two standoffs. 230V L1 U V W DECEL L2 TQ JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT 01:INPUT RANGE 1:0-5VDC 2:0 10VDC 115V S T E P # 8 S2 S3 TB501 230V L1 SECURE THE PCM ADDER BOARD WITH THE 6-32 x 1 5/16" PHILLIPS SCREW. INSTALLATION COMPLETE.

Installation 15 Mounting Warning DO NOT install, rewire, or remove this control with input power applied. Doing so may cause fire or serious injury. Make sure that you read and understand the Safety Warnings before attempting installation. NOTE: Horizontal mouting may require derating the drive. See your Minarik representative for more information It is recommended that the drive be oriented with the chassis vertical for best heat dissipation. Horizontal mounting, while acceptable, may require some thermal derating. Six 0.19-inch (5 mm) wide slots accept #8 pan head screws. Fasten either the large base or narrow flange of the chassis to the subplate. Drive components are sensitive to electrostatic fields. Avoid direct contact with the circuit board. Hold the drive by the chassis only.

16 Installation Protect the drive from dirt, moisture, and accidental contact. Provide sufficient room for access to the terminal block and calibration trimpots. Mount the drive away from heat sources. Operate the drive within the specified ambient operating temperature range. Prevent loose connections by avoiding excessive vibration of the drive. The chassis must be earth grounded. Use a star washer beneath the head of at least one of the mounting screws to penetrate the anodized chassis surface and to reach bare metal.

Installation 17 Wiring Warning DO NOT install, rewire, or remove this control with input power applied. Failure to heed this warning may result in fire, explosion, or serious injury. Circuit potentials are at 115 or 230 VAC above ground. To prevent the risk of injury or fatality, avoid direct contact with the printed circuit board or with circuit elements. Do not disconnect any of the motor leads from the drive unless power is removed. Opening any one motor lead may destroy the drive. Use 20 24 AWG wire for speed adjust potentiometer wiring. Use 14 16 AWG wire for AC line (L1, L2) and motor (U,V and W) wiring.

18 Installation Shielding guidelines Warning Under no circumstances should power and logic leads be bundled together. Induced voltage can cause unpredictable behavior in any electronic device, including motor controls. As a general rule, Minarik recommends shielding of all conductors. If it is not practical to shield power conductors, Minarik recommends shielding all logic-level leads. If shielding the logic leads is not practical, the user should twist all logic leads with themselves to minimize induced noise. It may be necessary to earth ground the shielded cable. If noise is produced by devices other than the drive, ground the shield at the drive end. If noise is generated by a device on the drive, ground the shield at the end away from the drive. Do not ground both ends of the shield.

Installation 19 If the drive continues to pick up noise after grounding the shield, it may be necessary to add AC line filtering devices, or to mount the drive in a less noisy environment. Logic wires from other input devices, such as motion controllers and PLL velocity controllers, must be separated from power lines in the same manner as the logic I/O on this drive. Heat sinking All VFD04-series drives are delivered with a factoryinstalled heat sink. All other VFD-series drives have sufficient heat sinking in their basic configurations. No additional heat sinking is necessary.

20 Installation Fusing VFD series drives require external AC power line fuses. Connect the external line fuse(s) in series with the AC voltage input. See Connections on page 22. Use fastacting fuses rated for 250 VAC or higher. See Table 1 for recommended line fuse sizes. Table 1. Line Fusing Chart 1-Phase AC AC Line Input Max Amps Fuse Drive (VAC) HP In Size (Amps) VFD01-230AC 230 ¼ 3 5 VFD01-D230AC 115 / 230 ¼ 7 / 3 10 / 5 VFD02-115AC 115 ¼ 7 10 VFD02-230AC 230 ½ 7 10 VFD02-D230AC 115 / 230 ½ 10 / 7 15 / 10 VFD04-115AC 115 ½ 10 15 VFD04-230AC 230 1 10 15 VFD04-D230AC 115 / 230 1 15 / 10 20 / 15

Installation 21 Speed adjust potentiometer Warning Be sure that the potentiometer tabs do not make contact with the potentiometer enclosure. Grounding the input will cause damage to the drive. Mount the speed adjust potentiometer through a 0.38 in. (10 mm) hole with the hardware provided (Figure 11). Install the circular insulating disk between the panel and the 10K ohm speed adjust potentiometer. Twist the speed adjust potentiometer wire to avoid picking up unwanted electrical noise. If speed adjust potentiometer wires are longer than 18 in. (457 mm), use shielded cable. Keep speed adjust potentiometer wires separate from power leads (L1, L2, U, V, W). MOUNT THROUGH A 0.38 IN. (10 MM) HOLE CW WIPER W NUT STAR WASHER SPEED ADJUST POTENTIOMETER PANEL INSULATING DISK Figure 11. Speed Adjust Potentiometer

22 Installation Connections Warning DO NOT connect this equipment with power applied. Failure to heed this directive may result in fire or serious injury. Minarik strongly recommends the installation of a master power switch in the voltage input line. The switch contacts should be rated at a minimum of 200% of motor nameplate current and 250 volts. Power and fuse connections VFDxx-115AC and VFDxx-230AC Series Connect the AC power input to L1 and L2 as shown in Figure 12 (page 23). Connect an external fuse between the drive and master stop switch. Install the switch between the external fuse and AC power input as shown.

Installation 23 V W LIMIT AULT J503 OWER AC AC - L2 L1 J502 * FUSE FUSE START/STOP SWITCH 115 / 230 VAC LINE INPUT * Do not add fuse to L2 unless line voltage is 230 VAC. Figure 12. AC Line and Fuse Connections for VFDxx-115AC and VFDxx-230AC Series Drives

24 Installation VFDxx-D230AC series Warning Do not connect 230 VAC line input when the drive is set for 115 VAC input. This will result in severe damage to the motor and drive, and can lead to explosion and/or injury. Check jumper settings before connecting AC power input. Connect AC power input to L1 and L2 as shown in Figure 13 and 14 (pages 25 & 26), depending on your power needs. NOTE: VFDxx-D230AC series drives are equipped with a voltage-doubling feature, which converts a 115 VAC input to a 230 VAC output, for use with 230V motors. The drive output current rating remains the same. Use caution when connecting this output. If the input voltage is 115 VAC and the desired output voltage is 230 VAC (voltage doubler mode), set 115V/230V jumper as shown in Figure 13 (page 25). A line fuse may be added to L2. If the input voltage is 230 VAC and the desired output voltage is 230 VAC (no voltage doubler), set 115V/230V jumper as shown in Figure 14 (page 26). Add a line fuse to L1 and L2. Do not use the voltage doubler feature with 230 VAC line voltage.

Installation 25 DECEL ACCEL TQ TQ V TH501 C501 W L2 WARNING Do not connect 230 VAC line input when the drive is set for 115 VAC input. This will result in severe damage to the motor and drive, and can lead to explosion and/or injury. IC502 C502 J501 115V START/STOP SWITCH 230V L1 FUSE 115 VAC LINE INPUT J501 Voltage Doubler Mode Setting (115 VAC in - 230 VAC out) Figure 13. AC Line and Fuse Connections for VFDxx-D230AC Series Drives (Voltage Doubler Mode)

26 Installation V W TH501 ECEL TQ L2 CCEL TQ C501 IC502 C502 J501 115V FUSE START/STOP SWITCH 230V L1 FUSE 230 VAC LINE INPUT J501 No Voltage Doubler (230 VAC in - 230 VAC out) Figure 14. AC Line and Fuse Connections for VFDxx-D230AC Series Drives (No Voltage Doubler)

Installation 27 Motor connections (all VFD-series controls) Single-phase operation For single-phase operation, connect the motor as shown in Figure 15 (page 28). Ensure that the prewired capacitor and its associated motor coil are connected to terminals U and V as shown. This connection may be internal if using a 2-wire motor. If the motor has three leads, you must make this connection yourself. To reverse a single phase split capacitor motor, connect the motor as shown in Figure 16 (page 29). The motor starter cap must be removed from the circuit. Three-phase operation Connect a three-phase motor to terminals U, V and W as shown in Figure 17 (page 30).

28 Installation NOTE MOTOR WINDINGS PREWIRED RUN CAPACITOR This connection may be internal to the motor (2 wire leads). If not, you must make this connection yourself. DO NOT use a DIRECTION switch with this set-up. See Figure 16 on Page 29 for setup using a DIRECTION switch. U V W TB501 DECEL BOOST TQ ACCEL TQ LIMIT J501 JMP501 FAULT J503 POWER IC502 AC AC - C510 L2 J502 L1 Figure 15. Motor Connections for Single-Phase Operation (Motor With Pre-Wired Capacitor)

Installation 29 MOTOR WINDINGS AUXILLIARY WINDING WITHOUT CAPACITOR NOTE Motor starter cap must be removed from the circuit. This method works with most (but not all) motors. U V W TB501 DECEL TQ ACCEL TQ LIMIT J501 MAX JMP501 FAULT J503 POWER IC502 AC AC - C510 L2 J502 L1 Figure 16. Motor Connections for Single-Phase Operation (Configured for use with DIRECTION switch)

30 Installation MOTOR WINDINGS U V W TB501 DECEL TQ ACCEL TQ LIMIT J501 MAX JMP501 FAULT J503 POWER IC502 AC AC - C510 L2 J502 L1 Figure 17. Motor Connections for Three-Phase Motors

Installation 31 Speed Adjust Potentiometer Connections Connect a speed adjust potentiometer to terminals S1, S2 and S3. Make sure the potentiometer is connected so that the motor speed will increase as the wiper (S2) is turned clockwise (CW). See Figure 18 below. TB501 E2 10K OHM SPEED ADJUST POTENTIOMETER E1 U V W S1 TB501 S2 DECEL ACCEL TQ LIMIT CW S3 D J501 JMP501 IC502 FAULT POWER AC C510 Figure 18. Speed Adjust Potentiometer Connections to TB501

32 Installation Voltage Follower Connections Instead of using a speed adjust potentiometer, the drive may be wired to follow a 0-10 VDC isolated voltage signal (Figure 19). Connect the signal input (+) to S2 and signal common (-) to S1. Make no connection to S3. A potentiometer can be used to scale the analog input voltage. The VFD-PCM adder board may be used to scale and isolate an analog input voltage (see Page 34). TB501 E2 SIGNAL COMMON (-) 0 TO + 10 VDC VOLTAGE SIGNAL SIGNAL INPUT (+) E1 S1 S2 S3 D Figure 19. Voltage Follower connections

Installation 33 Signal and Optional Switch Connections All signal and switch connections are made at TB501. Terminal block orientation and terminal names are identical for all VFD01, -02 and -04 series drives. Use 20-24 AWG wire for speed adjust potentiometer and switch connections. ENABLE/DISABLE switch Connect a single-pole, single-throw ENABLE/DISABLE switch between the ENABLE (E2) and COMMON (E1) terminals as shown. Open the switch to disable the drive and coast to a stop. Close the switch to accelerate to set speed at a rate controlled by the ACCEL trimpot. ENABLE/DISABLE SWITCH OPEN TO DISABLE TB501 E2 E1 (COMMON) S1 S2 S3 D Figure 20. Enable / Disable Switch connections to TB501

34 Installation DIRECTION (D) switch Connect a single-pole, single-throw DIRECTION switch between the (D) and COMMON (E1) terminals as shown in Figure 21 below. Opening the switch will cause the motor to rotate in the forward direction; closing the switch will reverse motor rotation. The drive will decelerate the motor to a stop, (at the DECEL trimpot setting), before reversing, so there is no need to wait for the motor to coast to a stop before changing direction. TB501 E2 E1 (COMMON) S1 S2 DIRECTION SWITCH CLOSE TO REVERSE S3 D Figure 21. Signal and Optional Switch Connections

Installation 35 Voltage or Current Follower (-PCM models) -PCM series drives can be configured to follow a grounded (non-isolated) voltage or current signal. To configure the drive to follow a voltage or current signal, connect the signal leads to the S1 and S2 terminals on TB501. Ensure that the following jumper terminals are properly set: JMP501 Input Range Settings Set jumper in position 1 for 0-5 VDC signal input. Set jumper in position 2 for 0-10 VDC signal input. Set jumper in position 3 for 4-20 ma signal input. JMP502 Input Type Jumper pins 1 & 2 for Voltage follower mode. Jumper pins 2 & 3 for Current follower mode. See Figure 22 on page 36 for jumper locations and terminal connections.

1 2 3 1 2 3 JMP501: INPUT RANGE Jumper position 1 for 0-5 VDC signal input Jumper position 2 for 0-10 VDC signal input 1: 0-5VDC 2: 0-10VDC PCM ADDER BOARD 36 Installation Jumper position 3 for 4-20 ma signal input 3: 4-20MA SET 4 ma 3:4-20MA 2:0-10VDC 1:0-5VDC JMP501:INPUT RANGE 2-3:CURRENT 1-2:VOLTAGE JMP502:INPUT TYPE JMP502: INPUT TYPE Jumper pins 1 & 2 for VOLTAGE follower mode 3 2 1 S1 S2 S3 E2 E1 D TB501 Jumper pins 2 & 3 for CURRENT follower mode S1 S2 S3 S1 S2 S3 TO SPEED POT or SIGNAL INPUT CW 10K OHM SPEED ADJUST SIGNAL NO INPUT CONNECTION 0-5 VDC or 0-10 VDC or 4-20 ma ENABLE DIRECTION POTENTIOMETER Figure 22. -PCM jumper locations and terminal connections

Operation Warning Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. BE ALERT. High voltages can cause serious or fatal injury. Do not change jumper settings with power applied. Ensure that jumper settings are compatible with the motor being controlled. 37 Voltage Input Warning for VFDxx-D230AC Drives DO NOT connect 230 VAC line input when the drive is set for 115 VAC input. This will result in severe damage to the motor and drive, and possible explosion and/or injury.

38 Operation Voltage Doubler Warning DO NOT connect 230 VAC line input when drive is set for 115 VAC input. This will result in severe damage to the motor and drive, and possible explosion or severe injury. VFDxx-D230AC series drives are equipped with a unique voltage-doubling feature, for use when 230 VAC input voltage is not available. This feature converts a 115 VAC input to a 230 VAC output, for use with 230V motors. The drive output current rating remains the same. Refer to Figure 12 (page 23) for connection information. Use extreme caution when connecting this feature. Incorrect use of this feature may result in fire and serious injury.

Operation 39 Startup Warning DO NOT change jumper settings with power applied. Ensure that jumper settings are compatible with the motor being controlled. Before applying power, verify that no conductive material is present on the printed circuit board. 1. Verify that no conductive material is present on the PCB. 2. Verify that the correct voltage is connected to the inputs before applying power. DO NOT CONNECT 230 VAC line voltage to a 115 VAC drive. Applying power in this manner will damage the motor and drive. 3. Set the speed adjust potentiometer to zero (full CCW). 4. Set the DIRECTION switch (if installed) to the desired direction. If no switch is installed, add or remove a jumper across the (D) and (E1) terminals, as required. 5. Set the ENABLE/DISABLE switch (if installed) to ENABLE, or short the ENABLE (E2) and (E1) terminals on TB501. 6. Apply 115 or 230 VAC, 50/60 Hz, single-phase power to the drive. The green POWER LED will come on after an initial delay of 1-2 seconds. If the POWER LED does not light, check the external line fuses to ensure that they are properly installed and not blown.

40 Operation 7. If you attempt to startup and the yellow TQ LED comes on, the control has entered torque limit mode. To avoid this occurrence, you may: a. increase the torque limit setting*, or b. lengthen the acceleration time enough to accomodate the needed starting torque by adjusting the ACCEL trimpot. * Do not set the torque limit setting above 150% of the motor s nameplate current rating. To reverse motor direction: To reverse the direction of motor shaft rotation while the motor is running, set the DIRECTION switch to the opposite position. If no DIRECTION switch is installed, open or short the (D) and (E1) terminals on TB501, as required. When a new direction is selected, there is no need to open the enable input. The control will automatically decelerate the motor to zero speed, reverse direction, and then accelerate the motor back to the set speed. Acceleration and deceleration rates are controlled by the ACCEL/DECEL trimpot settings. If quicker reversing is needed refer to applications notes section (page 51) for further detail.

Operation 41 Starting and stopping methods To coast the motor to a stop Open the ENABLE/DISABLE switch, or remove the jumper between the ENABLE (E2) and COMMON (E1) terminals of TB501. Refer to the Application Notes section (page 50) for instructions on switch installation. Thermal protection of the motor The enable input can also act as a motor thermal protection circuit for motors having a built-in thermal protector. These thermal protectors are operated only by motor heat and open the enable circuit when the motor reaches a temperature capable of causing damage to the motor winding. Normally, these thermal protectors automatically close the circuit when the motor has cooled to a safe temperature. In operation, when the drive is disabled, or when the motor overheats, the thermal protector opens the circuit. See Figure 23 (page 42).

42 Operation ENABLE / DISABLE SWITCH CLOSE TO ENABLE THERMAL OVERLOAD SWITCH TB501 E2 (ENABLE) E1 (COMMON) S1 S2 S3 D Figure 23. Thermal Overload Switch with Optional Enable / Disable Switch

Operation 43 Line starting and line stopping Warning Minarik strongly recommends the installation of a master power switch in the voltage input line (see Power and Fuse connections, page 22). The switch contacts should be rated at a minimum of 200% of motor nameplate current and 250 volts. Line starting and line stopping (applying and removing AC voltage input) is not recommended and should be used for emergency stopping only. When AC voltage input is applied to the drive, the motor accelerates to the speed set by the speed adjust potentiometer. When AC voltage input is removed, the motor coasts to a stop. To jog a motor, install a normally-open pushbutton switch on the ENABLE input.

44 Calibration Warning Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. When possible, disconnect the voltage input from the drive before adjusting the trimpots. If the trimpots must be adjusted with power applied, use insulated tools and the appropriate personal protection equipment. BE ALERT. High voltages can cause serious or fatal injury. The VFD series has five user-adjustable trimpots. Each drive is factory calibrated to its maximum horsepower rating. Re-adjust the calibration trimpot settings to accommodate lower horsepower motors. See Figure 24 (page 45) for VFD series trimpot location. All adjustments increase with clockwise (CW) rotation and decrease with counter-clockwise (CCW) rotation. Use a non-metallic screwdriver for calibration. Each trimpot is identified on the printed circuit board.

Calibration 45 DECEL Figure 24. VFD Series Calibration Trimpot Layout ACCEL TQ LIMIT MAX BOOST L2 ZERO SET on isolation board U V W TB501 TH501 DECEL TQ ACCEL C501 TQ C502 J501 230V 115V JMP502:INPUT TYPE 1-2:VOLTAGE 2-3:CURRENT TB501 D S3 S2 S1 JMP501:INPUT RANGE 1:0-5VDC E1 2:0-10VDC 3:4-20MA 2 L1 3

46 Calibration Calibration Procedure Setup for 60 Hz Motors: 1. Set the ENABLE switch to the DISABLE (open) position. If no switch is installed, remove the jumper between the (E2) and (E1) terminals of TB501. 2. Set the DIRECTION switch to the FWD (open) position. If no switch is installed, remove the jumper between the (D) and (E1) terminals of TB501. 3. Set all trimpots except TQ LIMIT and MAX fully counterclockwise (CCW). 4. Set the TQ LIMIT trimpot to maximum (full CW). 5. Set JMP501 & JMP502 to 1-2 position (3-phase output). 6. Set the speed adjust potentiometer to zero (full CCW). 7. Calibrate the trimmer pots as follows: MAXIMUM SPEED (MAX SPD) Rotate the speed adjust potentiometer full CW. Using a hand-held tachometer or analog frequency meter as a reference, adjust the MAX trimpot until the desired speed or frequency is reached.

Calibration 47 TORQUE LIMIT (TQ LIMIT) Warning Although the TQ LIMIT trimpot can be set up to 150% of the drive nameplate rating, continuous operation beyond the drive nameplate rating may cause damage to the motor and/or drive. 1. With no power applied to the drive, connect a (true RMS) ammeter in series with one of the motor leads. 2. Set the TQ LIMIT trimpot to full CCW. 3. Carefully lock the motor shaft. Ensure that the motor is firmly mounted. 4. Apply line power. The motor should be stopped. 5. Set the speed adjust potentiometer or reference signal to maximum speed. The motor should remain stopped. 6. Slowly rotate the TQ LIMIT trimpot clockwise (CW) until the ammeter reads 120% of maximum motor current. 7. Set the speed adjust potentiometer or reference signal to zero speed. 8. Remove power from the drive. 9. Remove the lock from the motor shaft. 10. Remove the ammeter in series with the motor lead.

48 Calibration ACCELERATION (ACCEL) 1. Set the speed adjust potentiometer to zero (full CCW) and wait for the motor to come to a stop (or minimum speed). 2. Set the speed adjust potentiometer or reference signal to maximum speed (full CW) and note the time the motor takes to accelerate to maximum speed. 3. If the acceleration time differs from the desired time, adjust the ACCEL trimpot until the desired time is reached. Rotating the ACCEL trimpot CW increases the acceleration time. DECELERATION (DECEL) 1. Set the speed adjust potentiometer to maximum (full CW) and wait for the motor to come to maximum speed. 2. Set the speed adjust potentiometer to minimum speed (full CCW) and note the time the motor takes to decelerate to minimum speed. 3. If the deceleration time differs from the desired time, adjust the DECEL trimpot until the desired time is reached. Rotating the DECEL pot CW increases the deceleration time.

Calibration 49 BOOST The boost trimpot is used to increase motor torque at low speeds. The minimum setting is sufficient for most applications and does not need to be adjusted. If the motor stalls or runs erratically at very low speeds (below 10 Hz), the boost trimpot may need adjustment. 1. Run the motor at the lowest continuous frequency/speed required. 2. Monitor the motor phase current (with a true RMS meter) while very slowly turning the BOOST trimpot CW until the motor operates properly, or 100% of the motor nameplate current is reached. NOTE: Use the absolute minimum amount of BOOST necessary to achieve proper motor operation. Improper use of the BOOST feature may cause motor and/or drive overheating and failure. If proper motion operation cannot be achieved with the above procedure, please contact your Minarik representative for assistance.

50 Calibration Calibration Procedure Conclusion 1. Set the speed adjust potentiometer to zero (full CCW). 2. Disable the drive by opening the ENABLE/DISABLE switch or removing the jumper from TB501 (E2) and (E1) terminals. 3. Remove power to the motor and drive. Calibration is now complete.

51 Application Notes Independent adjustable speeds with DIR switch Replace the speed adjust potentiometer with two singlepole multi-position switches, and two or more potentiometers in parallel, with a total parallel resistance of 10K ohms. Figure 25 shows the connection of two independent speed adjust potentiometers that can be mounted at two separate operating stations. TB501 FORWARD SPEED 20K OHM E2 E1 REVERSE SPEED 20K OHM S1 S2 S3 FORWARD REVERSE D (DIRECTION) Figure 25. Independent Adjustable Speeds

52 Application Notes RUN/JOG switch Using a RUN/JOG switch is recommended in applications where quick stopping is not needed and frequent jogging is required. Use a single-pole, two-position switch for the RUN/JOG switch, and a single-pole, normally open, momentary operated pushbutton for the JOG pushbutton. Connect the RUN/JOG switch and JOG pushbutton to terminal board TB501 as shown in Figure 26. The motor coasts to a stop when the RUN/JOG switch is set to JOG. Press the JOG pushbutton to jog the motor. Return the RUN/JOG switch to RUN for normal operation. NORMALLY OPEN RUN/JOG PUSHBUTTON JOG (motor coasts to stop) RUN/JOG SWITCH TB501 E2 (ENABLE) RUN E1 (COMMON) S1 S2 S3 D Figure 26. RUN/JOG Switch

Application Notes 53 Single speed potentiometer control of multiple motors Warning The combined current draw of all motors must not exceed the current rating of the drive. The VFD series of controls is capable of operating up to eight 3-phase motors simultaneously. All motors must be of the same type and must control similar loads. Connect each motor as shown in Figure 27 below. MOTOR A MOTOR B CW 10K OHM SPEED ADJUST POTENTIOMETER S3 S2 S1 U V W VFD SERIES DRIVE Figure 27. Single Speed Potentiometer Control of Multiple Motors

54 Application Notes Quick Reversing To reverse the direction of motor shaft rotation, install a DPDT center off switch as shown below (Figure 28). The drive will brake the motor before reversing, so there is no need to wait for the motor to coast to a stop before changing direction. TB501 FWD STOP DPDT CENTER OFF SWITCH E2 (ENABLE) E1 (COMMON) S1 REV S2 S3 D Figure 28. VFD Quick Reversing

55 Troubleshooting Warning Dangerous voltages exist on the drive when it is powered, and up to 60 seconds after power is removed and the motor stops. When possible, disconnect the voltage input from the drive while troubleshooting. BE ALERT. High voltages can cause serious or fatal injury. Before troubleshooting Perform the following steps before starting any procedure in this section: Disconnect AC voltage input from the drive. Wait 60 seconds for power to discharge. The green POWER LED will blink while power is discharging. Check the drive closely for damaged components. Check that no wire, chips, or other foreign material has become lodged on the printed circuit board. Verify that every connection is correct and in good condition.

56 Troubleshooting Verify that there are no short circuits or grounded connections. Check that the drive s rated phase current and RMS voltage are consistent with the motor ratings. For additional assistance, contact your local Minarik distributor, or the factory direct by telephone at: 1-800-MINARIK (646-2745) or Fax: 1-800-394-6334

Troubleshooting 57 Diagnostic LEDs Minarik VFD Series drives are equipped with diagnostic LED s to assist the user in troubleshooting and monitoring equipment status while in use. Refer to Figure 29 (page 58) for diagnostic LED locations. POWER LED The green POWER LED is on when AC line voltage is applied and the control s low-voltage power supply is operational. FAULT LED The red FAULT LED turns on when the drive output is locked out or not ENABLED and any one of the following fault conditions occur: 1. Overvoltage VFD 230AC controls: DC bus exceeds 400 VDC VFD 115AC controls: DC bus exceeds 200 VDC 2. Undervoltage VFD 230AC controls: DC bus drops below 200 VDC VFD 115AC controls: DC bus drops below 100 VDC 3. Instantaneous Overcurrent Trip - Inverter output current has exceeded safe levels. Note: The FAULT condition must be reset using the ENABLE function of the VFD (opening and closing the ENABLE input).

C510 58 Troubleshooting TQ LIMIT LED The yellow TQ LIMIT LED is on when the drive output current exceeds the threshold set by the TQ LIMIT trimpot. When the TQ LIMIT LED turns on, shut down the motor and drive by disabling or removing power. Check the motor to make sure it is not jammed or overloaded. The TQ LIMIT trimpot may need to be recalibrated. See the Calibration section (page 47) for information on calibrating the TQ LIMIT trimpot. U V W TB501 TQ DECEL ACCEL TQ TQ LIMIT FAULT J501 MAX JMP501 FAULT J503 POWER POWER IC502 AC AC - L2 J502 L1 Figure 29. VFD Series diagnostic LED locations

Troubleshooting 59 Problem Possible Cause Suggested Solution External line fuse blows External line fuse does not blow, but the motor does not run 1. Line fuses are the wrong size. 2. Motor or motor cable is shorted to ground. 3. Nuisance tripping caused by a combination of ambient conditions and high-current spikes (i.e. reversing). 1. Speed adjust potentiometer or voltage input signal is set to zero speed. 2. Speed adjust potentiometer or voltage input signal is not properly connected to drive input; connections are open. 1. Check that line fuses are properly sized for the motor being used. 2. Check motor cable and motor for shorts. 3. Add a blower to cool the drive components; increase TQ LIMIT settings (page 41). 1. Increase the speed adjust potentiometer setting or voltage input signal. 2. Check connections to input. Verify that connections are not open.

60 Troubleshooting Problem Possible Cause Suggested Solution External line fuse does not blow, but the motor does not run (cont.) 3. Drive is tripped off or has gone into thermal overload. 4. Drive has been disabled. 3. Disable, then reenable the drive. 4. Ensure that ENABLE (EN) and COM terminals are properly connected. Motor runs too slow or too fast at set speed 5. Drive is in current limit. 6. Drive is not receiving AC voltage input. 7. Motor is not connected. 1. MAX SPD trimpot is not calibrated correctly. 5. Verify that motor is not jammed. Increase TQLIM setting if it is set too low (page 41). 6. Apply AC line voltage to L1 and L2. 7. Connect motor to drive outputs U, V and W. 1. Calibrate MAX SPD trimpot (page 40).

Troubleshooting 61 Problem Possible Cause Suggested Solution Motor will not reach the desired speed Motor pulsates or surges under load 1. MAX SPD setting is too low. 2. Nominal input voltage may be too low for motor 3. Motor is overloaded. 1. Motor bouncing in and out of torque limit. 1. Increase MAX SPD setting (page 40). 2. Compare motor voltage to input voltage; replace motor if necessary 3. Check motor load. Resize the motor or drive if necessary. 1. Make sure motor is not undersized for load; adjust TQ LIM setting CW (page 41). Motor does not reverse 1. Defective DIRECTION switch connection. 2. Reversing circuit not working properly. 1. Check DIRECTION switch connection. 2. Check reversing circuit by shorting TB501 (D) terminal to (E1) terminal with jumper wire.

62 Troubleshooting Problem Possible Cause Suggested Solution TQ is unsatisfactory at high speeds. 1. TQ LIMIT set too low. 2. Load may exceed rating of motor/drive. 3. Nominal input voltage may be too low for motor. 1. Check TQ LIM setting (page 41). 2. Fix load (i.e., straighten mounting, coupling, etc.); or replace motor and drive with motor and drive rated for higher horsepower. 3. Compare motor voltage to input voltage. Replace motor if necessary.

Troubleshooting 63 Optional C510 Capacitor Kit (p/n: 202-0108) In some applications, lowering carrier frequency reduces switching losses and increases bearing life in some motors. Minarik provides an optional capacitor kit for lowering the carrier frequency. The default carrier frequency on VFD controls is 16kHz. Using one of the capacitors supplied in the kit, the carrier frequency can be lowered to a range of 12kHz to 4kHz. Note: Audible noise will increase when the carrier frequency is lowered. To lower the carrier freqency on all VFD controls, install one of the following 2-pin capacitors (C510) on the bottom board: LABEL ON CAPACITOR FREQUENCY VALUE 3n3J 12kHz 0.0033uF 6n8 10kHz 0.0068uF 10n 8kHz 0.01uF 33n 4kHz 0.033uF See Figure 30 on page 64 for C510 location and installation instructions.

64 Troubleshooting U V TB501 Cap Label DECEL ACCEL TQ BOOST TQ LIMIT 3n3 J100 FAULT POWER IC502 C510 CARRIER FREQUENCY CAPACITOR (C510) Insert the 2-pins of the carrier frequency capacitor into the 2 socket-holes (C510) located on bottom board. Figure 30. Carrier frequency capacitor location