Technical Information for PVX Series Pumps

Similar documents
HYDRAULIC VARIABLE PUMPS

PV Series E, J, & L Piston Pump Installation Tips and Procedures

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Variable displacement axial piston pumps,

Variable displacement axial piston pumps,

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

2.4 HEAVY DUTY SERIES

Pneumatic High-Viscosity Filtration System Instruction Manual

Variable displacement axial piston pumps,

Hydraulic and Commissioning Mannual Module 2A

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Medium and high pressure pumps

PowrFlow PVX Vane Pumps

Catalog PowrFlowTM PVX Vane Pumps

HYDRAULICS VINCKE HYDRAULIC PUMPS

Low Profile J Series Power Unit with Vane Pump

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

A10VO. Variable Displacement Piston Pump Technical Information Manual Module 3A

Series RFL In-Line Filter

Series PVP Variable Volume Piston Pumps

ENGINEERING DATA. Quick Reference Chart. Variable Volume Vane Pumps Models SV-20 & SV-25 Flange & Subplate Mounted. Industrial Hydraulics

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

PVD /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTER OPERATING PRINCIPLE

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Series 20 Axial Piston Pumps. Technical Information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Series 20 Axial Piston Pumps. Technical Information

MODEL 10LH SPECIFICATION

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

HY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)

EEiGl BOSCH. Engineering Data VARIABLE VOLUME VANE PUMPS MODEL SV-80 MODEL SV-100 QUICK REFERENCE FLANGE MOUNTED SYMBOL

HIGH VISCOSITY FILTER SYSTEMS

Whisper Pumps VPV Vane Pumps

Vickers. Vane Pumps. V Series - Low Noise Vane Pumps High Performance Intravane Pumps For Industrial Applications.

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Eclipse GEN 2.0 CAFSystem, Model 150-ECL CAFS PTO Kit Installation Instructions

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

NMSU FIRE DEPARTMENT FIRE PUMP ACCEPTANCE TEST

Filter Cart. hyprofiltration.com/fc

Fluid Maintenance. The hydraulic oil performs four functions in the hydraulic system:

Vane pumps single, double & triple T6 mobile application zp20

Internal Gear Pumps Installation Manual

5.1 MEDIUM HEAVY DUTY SERIES SIZE 2

2.3 MEDIUM HEAVY DUTY SERIES

Starting up hydraulic systems

VINCKE HYDRAULIC PUMPS

SPIN-ON FILTERS & ELEMENTS

D SERIES HYDRAULIC PUMP

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Ordering Code of 2PBA Pumps

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

shhark continuum PUMPS Group 1 l Technical Information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

DENISON HYDRAULICS vane pumps - single, double, triple T6 mobile application.

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

Denison GOLD CUP Product Catalog Piston Pumps & Motors For Open & Closed Circuits

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Hydraulic Pump Series VP1 Variable Displacement

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

12AT/50AT Series. Spin-On Filters. Global Filtration Technology

Return-Suction Filters E 158 E 198 E 248. Tank top mounting Connection up to -20 SAE Nominal flow rate up to 66 gpm us

Variable displacement axial piston pumps

Output flow In l/min at 1500 min

MOTOR SCM M2

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Off-Line Filtration OFF-LINE FILTRATION

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BQ

Series RFLD Duplex In-Line Filter

420 Mobile Piston Pump

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Mobile Piston Pump Series 620

6000 Series Highlights

CONTINENTAL HYDRAULICS VAD05M-VMD05M - AIR & LEVER OPERATED DIRECTIONAL VALVES

Eclipse GEN 2.0 CAFSystem, Model 150-ESECL as used with TC20 Series PTO Installation Instructions

Vane pumps single, double & triple T6 mobile application zp20

Steering unit LAGC. Data sheet

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

AP212HP Cast Iron Gear Pumps

SERIES G3DB/AG3DB ELEVATOR

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

P239-1 Supply Pumper Instructions

ISO Certificate N 12-E TIC. ISO 9001 Certificate N 12-Q TIC

Group 1 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

PUMP SCPD 56/26 DIN BY-PASS

Transcription:

Technical Information for PVX Series Pumps TM 604 PROGRESS DRIVE, HARTLAND, WI 53029 USA Phone: (262) 367-4299 FAX: (262) 367-5645 URL: www.hartmanncontrols.com E-mail: sales@hartmanncontrols.com

PVX pumps are designed for long and dependable service in both industrial and mobile applications. When incorporated into a well-planned and properly maintained hydraulic environment, pump(s) could be kept trouble free, thereby minimizing downtime of the system(s). Hydraulic Fluids PVX pumps are designed for use with standard petroleum-based hydraulic fluids. Special construction is available for use with water-based fluids or phosphate esters. Although, generally, 60/40 mixtures of water/glycol fluids may be regarded as equivalents to oils, one is encouraged to consult factory for specific details. Consult fluid-formulation manufacturer for detailed physicochemical properties of the fluid in question. Filtration For proper operation, adequate filtration is required in the circuit. A return line filter is preferred on the high pressure conduit as well as on the case drain return. In each case, filter flow capacity and pressure drop should be matched to pump performance ratings. Bypass filtration and suction filters and/or strainers are not recommended and, if possible, should be avoided. Finally, fluid cleanness should conform to ISO code 4406 as shown below: PRESSURE (PSI) ISO TARGET LEVELS MICRON RATINGS UNDER 2000 18/16/13 5 2000-2999 17/15/12 3 3000 & OVER 16/14/11 3 Operating Elastomers, Viscosities and Operating Temperatures PVX-series pumps are outfitted with Viton made shaft seal and O-rings. Other elastomers may be offered if fluid type or operating conditions warrant. To obtain most favorable service life from both the fluid and the pump, the accepted temperature range should span -4 F (-20 C) at the lowest end and 175 F (80 C) at s the upper end. In that context, the optimal viscosity level should be 150 SUS or 32 cst. Continuous, heavy duty operations are best accomplished by using fluids with viscosity levels ranging from 63 to 2500 SUS, i.e., from 14 to 540 cst. Thicker fluids may result in pump starvation/cavitation when operated in cold startups or low temperature environments. By contrast, thinner fluids may result in pump accelerated wear and, possibly, unstable performance. For extended limits or for non-petroleum-based fluid use, consult factory for details.

Inlet Conditions and Piping The temperature of the fluid at the inlet to the pump should not exceed 140º F. Likewise, the temperature in the reservoir should be kept at or below 140º F. If needed, a cooling system should be utilized on the case drain and high-pressure return lines. For more elevated temperatures consult factory. Strainers, screens and/or cooling grids, if installed in the tank, should be kept at least 1 foot away from the connection site to pump suction line. The suction pipe, hose or tubing should be sized properly to limit fluid bulk velocity to 5 ft/sec in industrial installations, and 8 ft/sec in mobile setups. Where feasible, a flooded inlet arrangement should be preferred. If impractical, the inlet conduit should be maintained as short as possible, and straight. Street elbows, restrictive valves, and other necked down parts should be avoided. All in all, pump inlet resistance should be limited to 6 Hg (3 psi). Suction hose, if used, must be wire reinforced to prevent its collapse. The suction line should be bolted to pump flanged-port with four bolts, unless the model ordered has a straight thread. If the pump has a SAE, code 61, 4-bolt flanged port the following bolt assignment shall apply: PVX PUMP MODEL INLET PORT SIZE BOLT SIZE & TYPE 110, 112, 114, 116, 118, 120 or 122 (Frame 0) SAE Straight Thread NA 116, 232, 348 or 360 (Frame 1) 1.00 Ø 3/8-16 UNC-2B 116, 232, 348 or 360 (Frame 1) 1.25 Ø 7/16-14 UNC-2B 116, 232, 348 or 360 (Frame 1) 1.50 Ø 1/2-13 UNC-2B 464 or 580 (Frame 2) 2.00 Ø 1/2-13 UNC-2B 696, 7112 (Frame 3) 2.50 Ø 1/2-13 UNC-2B 8128, 9144 or 10160 (Frame 3) 2.50 Ø 1/2-13 UNC-2B 11176 or 12190 (Frame 3) 2.50 Ø 1/2-13 UNC-2B 8128, 9144 or 10160 (Frame 4) 3.00 Ø 5/8-11 UNC-2B 11176 or 12190 (Frame 4) 3.00 Ø 5/8-11 UNC-2B All connections must be airtight. For METRIC, code 61, 4-bolt flanged ports, consult factory. Case Drain Two case-drain ports are provided on all pump models. To facilitate purging of air from the pump, casedrain piping should be connected to the top-most port. The case-drain line must be properly sized to limit port backpressure to < 15 psi. Although a ½ OD line is adequate for runs of up to 15 feet, it is suggested that the bulk velocity of fluid within the case-drain conduit be limited to 10 ft/sec in both, industrial and mobile installations. Use of clear, reinforced plastic tubing is optional to permit visual inspection of fluid flow during operation.

Case-drain line must be routed directly to the reservoir and it should extend below the fluid level, at an opposite end to suction inlet. This is especially pertinent in systems with negative suction pressure, when the reservoir is below pump level. Should the case-drain line be inattentively ending above fluid level, it may provide an air passage to pump case and allow priming fluid to gravity drain into the tank through the suction conduit. This, in turn, may result in loss of prime within the pump for the next startup. Pump case must be filled prior to startup. CAUTION: Do not connect valve drains or external returns to pump case-drain line as it may elevate the backpressure in the conduit beyond permitted level and, inadvertedly, lead to seal-lip compromise. Discharge Conditions and System Relief Valve The temperature of the hydraulic fluid at the pump discharge port should not exceed 170º F. For higher levels consult factory. Discharge pipe or hose should be sized properly to limit the build-up of a too high backpressure in system circuit. It is suggested that the bulk velocity of fluid within the output conduit be 15 ft/sec in industrial installations and 25 ft/sec in mobile setups. It is also recommended that an appropriately rated check valve, and (if feasible) a sequence valve be placed 3-6 ft downstream of the discharge port to prevent system back flow (reverse flow/pressure) effect and maintain the required minimal backpressure within pump architecture. PVX pumps require nominal backpressure at discharge port at all times, including during idle. When rating a check valve and/or sequence valve, the following guide should be consulted: PVX PUMP FRAME SIZE REQUIRED OVERALL BACKPRESSURE 0 150 psi 1 250 psi 2 350 psi 3 400-450 psi 4 400-450 psi A relief valve is required in all applications to protect personnel and system elements from potentially damaging pressure overloads and spikes. A fast acting, directly operated unit is strongly recommended. The unit should be installed between pump outlet and check or sequence valve position. The relief valve should be sized to 10% above the maximum flow in the system, and adjusted to about 10-12% above the setting of pump pressure compensator, torque limiter, or the combination thereof. Yet, if the pump is governed by a remote compensator, a system relief valve is optional provided the adjusting relief control on the piloted line has a relief valve guard, preset at 250 psi above the operational envelope.

Pump Mounting Guide Unless special orders are considered, all conventional PVX pumps are equipped with standard SAE coded mounts and drive shafts. When mounting and bolting a pump onto prime mover, the following guide should be consulted: MOUNT CLASSIFICATION NFPA POWER RATING BOLT SIZE SAE A 2 bolts mount 10 HP 3/8 Ø SAE B 2 bolts mount 25 HP 1/2 Ø SAE B 4 bolts mount 25 HP 1/2 Ø SAE C 2 bolts mount 50 HP 5/8 Ø SAE C 4 bolts mount 50 HP 1/2 Ø SAE D 4 bolts mount 100 HP 3/4 Ø Pump shaft should be connected to prime mover shaft with a jaw type flexible coupling. Shaft alignment must be within 0.003 (0.8 mm) TIR (total indicated run-out). Upon engagement, the input/through shaft torque should accord with the values recommended on the specification sheet of each pump model. Operating Pressures Continuous and peak pressure ratings of PVX series pumps are detailed on the respective specification sheets. These pressure levels should not be exceeded without consulting factory first. To accord with the specified ratings in a given application, the sizing of intermittent pressure loads can be evaluated using the duty cycle loading formula: P RMS =[(P 1 2 t 1 + P 2 2 t 2 +.+P n 2 t n )/(t 1 + t 2 + + t n )] ½ where Pj represents temporary pressure level during loading period tj, (j=1,2 n), and t1+ t2+ + tn =T, duration of one complete loading cycle. Controls All control units of the PVX-series pumps have a stackable modular design. These modules are fully interchangeable among the various displacement models. Tandem pumps Side ported PVX pumps with trough-drive option can be converted to tandem pumps by adding an adapter flange and shaft coupling to the rear pad. In addition, adapter flanges and/or shaft couplings can be ordered to readily resize the mounting pilot, bolting patterns and shaft input in accordance with the changing needs and/or demands. Consult factory for details.

Pump Priming and Startup When starting a pump for the first time or if the pump is about to be started after its or system overhaul, the following guides should be consulted: 1) Make sure the reservoir and all system equipment meet NFPA guidelines. 2) Make sure the system has been thoroughly flushed of all contaminants, cleansers and/or preservatives. 3) Fill pump case with hydraulic fluid. 4) Check direction of rotation on pump label and verify it against the direction of rotation of the prime mover. Damage may result to the unit if the directions of rotation do not match. 5) Make sure pump shaft turns easily. 6) Start prime mover. Idle system and allow all air to be purged from the circuit. Do not operate the pump at elevated pressure until the fluid circulated is free of foam and air bubbles. 7) Gradually apply load to the system permitting hydraulic fluid flow to challenge tightness of circuit connections. 8) Allow the system to reach normal operating temperature and verify proper operation of circuit cooler. 9) Gradually close the control valve in pump discharge line and observe on a nearby gauge pump-control pressure setting. 10) Adjust pump-control pressure and match it to relief valve preset level (200-250 psi above pump desired setting). Verify relief valve intactness. 11) Reset pump-control pressure to the desired setting. 12) Bring system to normal operating mode. CAUTION: Do not tamper with pump null and volume control adjustments during pump/system startup, unless absolutely necessary, or if so advised by a HCI engineer.