Vmax Medium voltage vacuum circuit-breakers. IEC: kv; A; ka ANSI: kv; A; ka

Similar documents
HD4. Gas insulated MV circuit-breakers kv A ka

VD4 Installation and service instructions kv A ka

VD4/R. Medium Voltage vacuum circuit-breakers for secondary distribution

HD4. Gas insulated MV circuit-breakers kv A ka

Medium Voltage Products. VD4 Medium voltage vacuum circuit-breaker 12 kv A - 63 ka 36/40.5 kv A ka

VD4. Installation and service instructions kv A ka

PRODUCT INSTRUCTION. Vmax Medium voltage vacuum circuit-breakers kv A ka

HD4. Gas insulated MV circuit-breakers kv A ka

Medium voltage indoor circuit breakers ANSI/IEC solutions

VD4/R - VD4/L - VD4/UniAir - VD4/UniMix

Outdoor live tank SF 6. circuit breaker Type OHB for 24/36/40.5 kv applications

VD4 Installation and service instructions 36 kv A ka

HD4 Installation and service instructions kv A ka

PowerCube type PB. Pre-assembled modules and enclosures for constructing medium voltage switchgear

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

Air-insulated switchgear UniGear type ZS1

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

High voltage products PASS M0S 252 kv Innovative solution for transmission substation up to 252 kv

Medium voltage products HD4/R - HD4/RE MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

VD4/R. MV vacuum circuit-breakers for secondary distribution

Medium voltage products. V-Contact VSC Medium voltage vacuum contactors

UniGear type ZS1. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

DISTRIBUTION SOLUTIONS. VD4G Medium voltage vacuum circuit breakers 15 kv A ka

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Contactor V-Contact VSC/P

Air-insulated medium-voltage secondary distribution switchgear

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

OHB Outdoor sulphur Hexafluoride circuit-breaker

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

PowerLine OS Switch Fuses A, 690V

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

Outdoor vacuum breaker for railway applications - FSK II

Switches for photovoltaic applications Disconnect switches, UL OTDC_U from 16 to 32 Amperes

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Medium Voltage Products. SHS2 Gas-insulated switching and isolating apparatus

UniSec Operation and maintenance manual

Power IT MV Live Tank Vacuum Circuit Breaker. Model OVB-SDB

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

DISTRIBUTION SOLUTIONS HA Breaker Retrofit. Medium Voltage Service Marketing and Sales

2018 Life Cycle Management. ABB Italy medium voltage products for marine application

W-VACi IEC medium voltage vacuum circuit breakers 12 kv, 17,5 kv and 24 kv

NIRAPOD 5. Vacuum Circuit Breaker. 630A A: 7.2kV - 12kV 20kA - 25kA kA 12AV20. current CHARGED CHARGED

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

ZX-Family Gas-insulated medium voltage switchgear

3TM Vacuum Contactors

HD4-LMT. MV SF6 Circuit Breaker Installation and Service Instructions kv 1,250 A 31.5 ka

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

PEHLA Testing Station Ratingen ABB Medium Voltage Laboratories

Power IT MV Live Tank Vacuum Circuit Breaker Model VBF

0MV vacuum circuit breaker. 0Evolis 24 kv. 0User 0Manual. Creation Printed on 2008/07/17

CPG.0 Single busbar gas-insulated cubicles

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

Modular medium-voltage switchgear. NorMax

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

PowerCube type PB series A complete solution for OEMs

CATALOGUE. ON Medium Voltage Outdoor Disconnectors

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

PIX-H Metal-clad switchgear up to 17.5kV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

IEC medium voltage vacuum circuit breakers 12 kv, 17.5 kv and 24 kv Product Guide. W-VACi. for safety, reliability and performance

Siemens AG Catalog HG11.07 Edition 10/ AE6 Medium-Voltage Equipment. siemens.com/sion

ABB AG - Calor Emag Medium Voltage Products OEM Products Medium Voltage Products. ABB OEM Products 1

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Motorized switch-disconnectors OTM 40 to 125 Amperes

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

Protection components

Vacuum Circuit Breakers kv

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

UniSec Maintenance solutions

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Rated voltage 12 kv to 38.5 kv Rated current 630 A to 2500 A

High Voltage Products. COMPASS Compact Prefabricated Air Insulated Substation

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Reverse power relay and protection assemblies

SafeGear TM Motor Control Center Arc resistant metal-clad construction

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Low Voltage Systems MNS platform

NXPLUS C Single busbar. Maintenance-free for lifetime

voltage switchgear ZX ABB ZX Family 1

Transcription:

Medium voltage products Vmax Medium voltage vacuum circuit-breakers IEC:... 17.5 kv;... 1250 A;... 31.5 ka ANSI:... 15 kv;... 1200 A;... 31.5 ka The new Vmax circuit-breakers are the synthesis of ABB s affirmed technology in designing and constructing vacuum interrupters and their excellence in the production of circuit-breakers. The Vmax medium voltage circuitbreakers consist of an insulating monobloc in which three vacuum interrupters are housed. The monobloc and operating mechanism are fixed to a frame. The vacuum interrupter houses the contacts and makes up the interrupting chamber. Main characteristics Vacuum interruption technique Contacts in vacuum protected against oxidation and contamination Operation under different climatic conditions Limited switching energy Stored energy operating mechanism with anti-pumping device supplied as standard Simple customisation with a complete range of accessories Fixed and withdrawable version Compact dimensions Sealed-for-life vacuum interrupters Sturdiness and reliability 10,000 operations with regular maintenance Circuit-breaker racking in and racking out with the door closed Incorrect and hazardous operations prevented thanks to special locks in the operating mechanism and in the truck

Vmax vacuum circuit-breakers EL type operating mechanism The operating mechanism of Vmax circuit-breakers is of simple concept and use and can be customised with a wide range of easily and rapidly installed accessories. This simplicity translates into greater reliability of the apparatus. The operating mechanism is of the stored energy type with the anti-pumping device mounted as standard and it is fitted with suitable locks to prevent incorrect operations. Each operation sequence is only enabled if all the conditions ensuring it being carried out correctly are respected. The accessories are the same for all the types of Vmax circuit-breakers. To facilitate assembly and replacement of accessories, assembly seats with special fixed references are provided. Circuit-breaker operating mechanism (push-button and mechanical indicators according to IEC STDs) F M A N L I C H D G B O E A Open/closed auxiliary contacts B Geared motor for closing spring charging C Built-in closing spring charging lever D Mechanical signalling device for circuit-breaker open/closed E Mechanical operation counter F Plug-socket connectors of electrical accessories G Signalling device for closing springs charged/discharged H Service releases (shunt opening release, shunt closing release, undervoltage release) I Closing pushbutton L Opening pushbutton M Additional shunt opening release N Locking magnet on the operating mechanism O Contact for signalling closing spring charged/discharged 2

The structure The operating mechanism, the monobloc and the interrupters are fixed to a metal frame which is also the support for the fixed version of the circuit-breaker. The compact structure ensures sturdiness and mechanical reliability. Apart from the isolating contacts and the cord with plug for connection of the auxiliary circuits, the withdrawable version is completed with the truck for racking it into and out of the switchgear with the door closed. Fields of application Vmax circuit-breakers are used in electrical distribution for protection of cables, transformer and distribution substations, motors, transformers, generators and capacitor banks. Standards and approvals Vmax circuit-breakers comply with the IEC 62271-100, CEI-EN 62271 (file 7642), ANSI/IEEE C37.54-C37.09- C37.04-C37.55 and with those of the major industrialised countries. The Vmax circuit-breakers have undergone the tests indicated below and guarantee the safety and reliability of the apparatus in service in any installation. Type tests: heating, withstand insulation at industrial frequency, withstand insulation at atmospheric impulse, short-time and peak withstand current, mechanical life, making and breaking capacity. Individual tests: insulation of the main circuits with voltage at power frequency, auxiliary and control circuit insulation, measurement of the main circuit resistance, mechanical and electrical operation. Versions available Vmax circuit-breakers are available in the fixed and withdrawable version with front operating mechanism. The withdrawable version is available for UniGear ZS1 switchgear with width 550 mm, and for PowerCube modules with width 600 mm. A specific fixed version is available for UniGear 500R switchgear. Remark: all the above mentioned switchgears are according to IEC Standards only. Accessories The Vmax circuit-breakers have a complete range of accessories to satisfy all installation requirements. The operating mechanism has a standardised range of accessories and spare parts which are easy to identify and order. The accessories are installed conveniently from the front of the circuit-breaker. Electrical connection is carried out with plug-socket connectors. Use, maintenance and service of the apparatus are simple and require limited use of resources. Service safety Thanks to the complete range of mechanical and electrical locks (available on request), it is possible to construct safe distribution switchgear with the Vmax circuit-breakers. The locking devices have been studied to prevent incorrect operations and to inspect the installations guaranteeing maximum operator safety. Key locks or padlock devices enable opening and closing operations and/or racking in and racking out. The racking-out device with the door closed allows the circuitbreaker to be racked into or out of the switchgear only with the door closed. Anti-racking-in locks prevent circuit-breakers with different rated currents from being racked in, and the racking-in operation with the circuit-breaker closed. 3

General characteristics of fixed circuit-breakers Circuit-breaker Fixed version Fixed version for ABB UniGear 500R panel IEC 62271-100 CEI EN62271-100 (file 7642) Standards C37.54 - C37.09 - C37.04 - C37.55 UL Recognized Component Mark Rated voltage Ur [kv] Rated insulation voltage Us [kv] Withstand voltage at 50 Hz Ud (1 min) [kv] Impulse withstand voltage Up [kv] Rated frequency fr [Hz] Rated normal current (40 C) Ir [A] Rated breaking capacity (rated symmetrical short-circuit current) Isc [ka] Standard fittings for fixed circuit-breaker series (1) The basic versions of the fixed circuit-breakers are three-pole and fitted with: EL type manual operating mechanism mechanical signalling device for closing springs charged/ discharged mechanical signalling device for circuit-breaker open/closed closing pushbutton opening pushbutton operation counter set of ten circuit-breaker open/closed auxiliary contacts (2) lever for manually charging the closing springs auxiliary circuit support terminal board. Rated-short time withstand current (3s) Making capacity Operation sequence Opening time Arc duration Total interruption time Closing time Maximum overall dimensions Weight H W P P Standardized table of dimensions Operating temperature D Ik [ka] Ip [ka] [O - 0.3 - CO - 15 - CO] [O - 0.3 - CO - 3 - CO] H [mm/in] W [mm/in] D [mm/in] Pole centre P [mm/in] [kg/lb] 1VCD Tropicalization IEC: 60068-2-30, 60721-2-1 Electromagnetic compatibility IEC 62271-1 (*) This version cannot be sold loose; this version can only be supplied together ABB UniGear 500R switchgear [ C] (1) Refer to the UniGear 500R catalogue for the standard equipment of the Vmax/F circuit-breaker. (2) Application of the shunt opening release and/or the supplementary shunt opening release foresees the use of one and/or two auxiliary make contacts (normally open), thereby reducing the number of available auxiliary contacts. 4

Vmax 12 Vmax 17 Vmax/F 12 (*) Vmax/F 17 (*) Vmax 15 - - - - - 12 17.5 12 17.5 15 12 17.5 12 17.5 15 28 38 28 38 36 (at 60 Hz) 75 95 75 95 95 50-60 50-60 50-60 50-60 60 630 1250 630 1250 630 1250 2000 630 1250 2000 1200 16 16 16 16 - - - - - - - 20 20 20 20 - - - - - - - 25 25 25 25 25 25 25 25 25 25 25 (3 cycles) 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 (3 cycles) 16 16 16 16 - - - - - - - 20 20 20 20 - - - - - - - 25 25 25 25 25 25 25 25 25 25 25 (2s) 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 (2s) 40 40 40 40 - - - - - - - 50 50 50 50 - - - - - - - 63 63 63 63 63 63 63 63 63 63 65 80 80 80 80 80 80 80 80 80 80 82 33.5... 60 33.5... 60 33.5... 60 33.5... 60 27... 32.5 10... 15 10... 15 10... 15 10... 15 10... 17.5 43.5... 75 43.5... 75 43.5... 75 43.5... 75 <50 45... 80 45... 80 45... 80 45... 80 45... 80 496 534 543 543 543 543 534/21.02 416 416 416 516 416 516 416/16.38 421 456 461 562 461 562 456/17.95 133 133 133 133 133 133 133/5.24 77 77 77 80 77 80 77/169.40 003279 003279 003516 003558 003516 003558 003279-5... +40-5... +40-5... +40-5... +40-30... +40 5

General characteristics of withdrawable circuit-breakers Circuit-breaker Use in switchgear/enclosure Standards Rated voltage Rated insulation voltage Withstand voltage at 50 Hz Impulse withstand voltage Rated frequency Rated normal current (40 C) IEC 62271-100 CEI EN62271-100 (file 7642) C37.54 - C37.09 - C37.04 - C37.55 UL Listed Ur [kv] Us [kv] Ud (1 min) [kv] Up [kv] fr [Hz] Ir [A] Rated breaking capacity (rated symmetrical short-circuit current) Isc [ka] Rated-short time withstand current (3s) Ik [ka] Standard fittings for withdrawable circuit-breaker series The basic versions of the withdrawable circuit-breakers are three-pole and fitted with: EL type manual operating mechanism mechanical signalling device for closing springs charged/ discharged mechanical signalling device for circuit-breaker open/closed closing pushbutton opening pushbutton operation counter set of ten circuit-breaker open/closed auxiliary contacts (1) lever for manually charging the closing springs isolating contacts cord with connector (plug only) for auxiliary circuits, with striker pin which does not allow the plug to be inserted into the socket if the rated current of the circuit-breaker is different from the rated current of the panel racking-in/out lever (the quantity must be defined according to the number of pieces of apparatus ordered) locking electromagnet in the truck (-RL2). This prevents the circuit-breaker being racked into the panel with the auxiliary circuits disconnected (plug not inserted in the socket). Making capacity Operation sequence Opening time Arc duration Total interruption time Closing time Maximum overall dimensions Weight H W P P Standardized table of dimensions Operating temperature D Ip [ka] [O - 0.3" - CO - 15" - CO] [O - 0.3" - CO - 3' - CO] H [mm/in] W [mm/in] D [mm/in] Pole centre P [mm/in] [kg/lb] 1VCD Tropicalization IEC: 60068-2-30, 60721-2-1 Electromagnetic compatibility IEC 62271-1 [ C] (1) Application of the shunt opening release and/or the supplementary shunt opening release foresees the use of one and/or two auxiliary make contacts (normally open), thereby reducing the number of available auxiliary contacts. 6

Vmax/L 12 Vmax/L 17 Vmax/W 12 Vmax/W 17 Vmax/W 15 UniGear 550 UniGear 550 PowerCube PowerCube PowerCube - - - - (on request) 12 17.5 12 17.5 15 12 17.5 12 17.5 15 28 38 28 38 36 (at 60 Hz) 75 95 75 95 95 50-60 50-60 50-60 50-60 60 630 1250 630 1250 630 1250 630 1250 1200 16 16 16 16 16 16 16 16-20 20 20 20 20 20 20 20-25 25 25 25 25 25 25 25 25 (3 cycles) 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 (3 cycles) 16 16 16 16 16 16 16 16-20 20 20 20 20 20 20 20-25 25 25 25 25 25 25 25 25 (2s) 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 31.5 (2s) 40 40 40 40 40 40 40 40-50 50 50 50 50 50 50 50-63 63 63 63 63 63 63 63 65 80 80 80 80 80 80 80 80 82 33.5... 60 33.5... 60 33.5... 60 33.5... 60 27... 32.5 10... 15 10... 15 10... 15 10... 15 10... 17.5 43.5... 75 43.5... 75 10... 17.5 43.5... 75 <50 45... 80 45... 80 45... 80 45... 80 45... 80 665 665 665 665 665 665 665 665 665/26.18 461 461 461 461 503 503 503 503 503/19.80 665 665 665 665 662 662 662 662 662/26.06 150 150 150 150 150 150 150 150 150/5.91 98 98 98 98 98 98 98 98 98/215.60 003334 003334 003280 003280 003280-5... +40-5... +40-5... +40-5... +40-30... +40 7

Contact us ABB S.p.A. Power Products Division Unità Operativa Sace-MV Via Friuli, 4 I-24044 Dalmine Tel.: +39 035 6952 111 Fax: +39 035 6952 874 E-mail: info.mv@it.abb.com ABB Oy Distribution Automation P.O. Box 699 FI-65101 VAASA, Finland Phone +358 10 22 11 Fax +358 10 22 41094 www.abb.com/substationautomation The data and illustrations are not binding. We reserve the right to make changes without notice in the course of technical development of the product. Copyright 2011 ABB. All rights reserved. 1VCP000183 - Rev. B, en - Leaflet - 2011-02 - (Vmax) (gs) ABB AG Calor Emag Medium Voltage Products Oberhausener Strasse 33 Petzower Strasse 8 D-40472 Ratingen D-14542 Glindow Phone: +49(0)2102/12-1230, Fax: +49(0)2102/12-1916 E-mail: powertech@de.abb.com www.abb.com