Universal Bench-top Conveyor OPERATOR S GUIDE

Similar documents
PORTABLE 2 UV CURING SYSTEM OPERATING INSTRUCTIONS

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

UV PROCESS SUPPLY, INC.

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

PMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks

G500REC Manual Covering System for Containers

JD2800 Module Installation Guide

Easy Packer. Industrial Case Erecting, Packing and Taping System. User Guide

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

GDP STREET-GATE 38mm Wastegate System

DynaCon Instruction Manual

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

RACE PPE Manifolds and Up-Pipes

Model E600 Tarping System

NEW GEN OWNER S MANUAL

SUNTURA SOLAR TRACKER

30100 Module Installation Guide L

MaxLite LED Linear HighBay Fixtures

Mega-Rail System Installation

15100 Module Installation Guide Mercedes EPA07 w/dpf

Submersible Pond Pump with UV 800 Gallons Per Hour

Dear Customer, User Memo: Please visit us on facebook or twitter! Thank you for purchasing this product.

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

TBM Series 3-Way Ball Valve

CU6703 Module Installation Guide

LT-EL138 LED Flashlight

SUNTURA HD SOLAR TRACKER

Dual Fueler Kit Dodge Cummins 6.7L kit w/no pump ( ) package w/pump ( ) Installation Guide

DODGE CUMMINS GDP Big Line Kit

20250 Module Installation Guide

Submersible Waterfall Pump 1200 Gallons Per Hour

Air-Boss VP Intake Plenum

HOW TO INSTALL YOUR BOV

Dual Fueler CP3 Pump Kit Installation Guide for LBZ/LMM

L DODGE CUMMINS Maximizer System

DODGE CUMMINS GDP Twin CP-3 Big Line Kit

Guardian Steel Gear Shaft Coupling

DODGE CUMMINS 24V ISB OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

Assembly Instructions

Premium Pond Pump 330 Gallons Per Hour

EZ-EX Tape Head (2" & 3" )

DODGE CUMMINS MK-2 Micro-Kleen System

3M Closure System 2-Type Cover (505)

DODGE CUMMINS Air-Boss CR Intake Plenum

Dodge 24v ISBe

TS PERFORMANCE WE ARE DIESEL

CS Fiber Optic Splice Case. Instruction

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

HOW TO INSTALL YOUR BOV

Premium Waterfall Pump 1200 Gallons Per Hour

Container Fountain Kit with LED Light

Fitting Instruction for EZI-GRIP Bike Rack

MaxLite StaxMax LED Flood Lights

Crestron TTK-MP/MPC/IPAC & SMK-MP/MPC/IPAC TableTop and Swivel Mount Kits Installation Guide

Mechanical Lift Pump System

Female Plug. connecting to Fuel Quantity

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

WARRANTY REGISTRATION AND POLICY

Illumifalls Kit REMINDER CALL BEFORE RETURNING TO STORE.

Dual Fueler CP3 Pump Kit Installation Guide for LB7

TABLE OF CONTENTS DESCRIPTION. Safety Instructions & Safety Sign Locations Operating Instructions Assembly Instructions...

Illumifalls Patio Pond

NEW EQUIPMENT WARRANTY

Do not install and/or operate this safety product unless you have read and understand the safety information contained

JDCR2000 Module Installation Guide

48" and 52" Hyflo Fans Installation and Operators Instruction Manual

TOOLS REQUIRED General mechanic tools

Assembly Instructions

Pressurized Pond Filter Up to 850 gallons

Power Edge Juice Module Ford 6.0 Powerstroke Diesel

INSTALLATION MANUAL DURAMAX DIESEL POWERED PICKUP TRUCKS MODEL RP-100 & RP-150. With New Quick Connect Components!

FTFR Maintenance and Parts Manual SQ-1 FLOOR TRUSS FINISH ROLLER. Operators Manual

Natural Fiber Planter Fountain

Forbidden Diesel Performance Ford 6.7L Powerstroke EGR Delete Instructions 6.7L EGR DELETE BY FORBIDDEN DIESEL PERFORMANCE. Page 1

Low-Water Auto Shutoff Pump 420 Gallons Per Hour

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

OLYMPIAN MODEL 740 Operation and Service Manual

6701 KNIFE GATE VALVES

FS Series INSTRUCTION AND MAINTENANCE MANUAL: FS SERIES SHEAR BLENDER. Sanitary Mixing and Blending Equipment

Thank you for purchasing a 911EP GALAXY Light Bar! Every light bar is carefully inspected for defects prior to shipment.

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

Installation Instructions for Part #: KPS01 - KPS07 Karcepts A/C & P/S Removal Kit (With Alternator Relocation)

OWNER S MANUAL Z SERIES TRACKS. Rev. 355_05

INSTALLATION INSTRUCTIONS

THIS IS A HIGH PERFORMANCE PRODUCT - USE AT YOUR OWN RISK!!!

Installation instructions for IPS parking Brake Kit for 1996 to 2002 Viper

All products subject to this warranty must be returned for examination, repair or replacement to:

BMK-27. Dual Remote Filtration System Mounting Kit. Installation and Servicing Instructions (DURAMAX) C. Oil Supply

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

Visit Our Web Site

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

Product/ Title Guardian Super Flex Shaft Coupling Product/ Title

Guardian HH Shaft Coupling

BEAMER Tilt Beam Sensor

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Mechanical Filter Box Kit

Dfuser Stage I Power Module DT-466, DT-570, and HT-570

Container Fountain Kit

Transcription:

OPERATOR S GUIDE

DISCLAIMER LIABILITY LIMITATION: The Buyer of this product accepts full responsibility and understanding for the terms and specifications set forth herein. Con-Trol-Cure makes no claim, expressed or implied, as to the performance of this product. ANY LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES IS EXPRESSLY DISCLAIMED. CON-TROL-CURE S LIABILITY IN ALL EVENTS IS LIMITED TO, AND SHALL NOT EXCEED, THE PURCHASE PRICE PAID. All risk arising out of the performance of this unit remains solely with the Buyer. In no event shall Con-Trol-Cure be held liable for lost profits, lost savings, incidental or direct damages or other economic consequential damages regardless of any statement, expressed or implied, of such liability by Con-Trol-Cure employees or any of its authorized agents. In addition, Con-Trol-Cure and its suppliers will be held harmless for any damages claimed on behalf of any third party Page 2 of 5

1 3 4 6 2 5 3 Orientation: 1 In-feed a. The in-feed section consists of an idler roller and belt tracking guide collars. (Caution! There is an inward nip 5 present between the rotating collars and a cross support 4 bar. Keep hands clear of this area) b. The tracking guide collars help keep the belt centered regardless of how well adjusted the tension is. However, 6 always ensure there is a small gap present between the collars and the belt to prevent rubbing and wear. If the belt consistently tries to ride up on one of these collars, belt adjustment is required. (see belt adjustment section) c. Take special care to ensure the collars are positioned square on the roller (no wobble) and do not over tension collars, especially if located on the extreme outer edges of the idle roller. Over tensioning in this region will compress the idle roller bearings causing premature wear of the idle roller bearings and may overheat the drive roller motor due to excessive load. 2 Conveyor Power a. The conveyor power section input power to cord is 110V 50/60Hz. Also in this section is the main power switch. 3 UV Curing a. The UV curing section is the area where you will locate your UV lamp housing. The chevron heat exchanger allows air to flow through to cool the plate, while blocking any UV light due to the tight overlapping V-shape pattern. Locate your UV lamp near the center of this plate for optimum results. 4 Conveyor Fan a. The conveyor fan section cools the belt as well as functions as a vacuum hold-down for smooth exit of lightweight papers and materials. 5 Conveyor Control a. The conveyor control section is where you will find your conveyor belt speed control dial. Our conveyors ship with a variety of speed ranges based on end users requirements. The default range is 24:1 ratio ( 40-136 fpm ) Page 3 of 5

6 Conveyor Belt Adjustment (refer to pictures on previous page) The conveyor belt adjustment allows you to adjust the tension of the belt for even and smooth tracking. This roller is the power drive for the conveyor, therefore it is important not to bind the roller at any extreme angles or damage to the drive mechanism can occur. Replace the belt if excessive angle adjustments are needed to keep belt tight on both sides and tracking properly. Excessive tension will cause premature belt failure. Belt Tensioning Adjustment The belt is preset at the factory for proper tension and tracking. Through normal use, heat will cause the belt to expand and therefore it may need to be tightened slightly to maintain tracking. Do not over tighten. Excessive tension will stretch the belt, and also cause additional strain against the Drive Roller Motor, resulting in a potential premature failure of the belt and/or drive roller. To adjust tracking:!! Warning! Never loosen the screw on the back of this adjuster. This is the locking screw for the drive roller shaft. If the locking screw becomes loose, the shaft can spin, twisting the wire harness and permanently damaging the drive roller. Periodically check this screw to ensure it is tight. Locate the double Allen screws on the ends of the tensioning adjusters. (There is a pair on the left and right side of the conveyor) One the side the belt is drifting towards; turn either one of the two screws clockwise to tighten the belt on that side. This forces the belt back the other way. Make very small adjustments to avoid over tensioning. You may want to *manually slide the belt to center first, and then make an adjustment. This prevents over adjusting. (*depending on belt width relative to overall conveyor width) Once the belt is tracking stable, carefully turn the second screw clockwise until it seats into the adjuster at the same amount as the first screw. Be careful not to over tighten because this will further adjust the roller, which in turn will put slack in the opposite screw. The purpose of the second screw is to secure the roller so that the belt tension and vibration does not cause the roller to travel backwards (loosen) on its own. Changing the Belt To remove the belt, loosen all four adjusting screws (counter-clockwise) until the roller is at its closest point toward the lamp housing. Locate the metal splice on the belt (looks like a zipper). There is a wire pin interwoven through this splice. Simply slide the pin completely out (either side) and the belt will separate. Reverse the process for putting on a new belt. Always tension the belt evenly and lightly. Over tensioning a new belt will cause it to stretch quickly especially when heated by the lamp for the first time. This can cause premature failure of the belt, and/or create stress cracks in the edge seams. Page 4 of 5

General Operation Guidelines and Safety If using this conveyor with a UV light source: always ensure that the belt is in motion when the UV light is on. Even after UV light is switched off, allow the belt to remain in motion for 5 10 minutes while lamp cools. Failure to do so may result in burns to the belt. When adding your UV light to this conveyor, be certain to provide sufficient shielding to protect the operator from UV exposure. We have furnished two pieces of rigid blue UV shielding to supplement your own shielding. Use this material as you see best suited in conjunction with your own primary shielding. The rigid blue UV filters material is not intended for direct viewing of the UV light. This material should only be used as a way of viewing the entrance and exit where the potential of reflected UV light exposure is most likely. The higher you locate your lamp housing above the belt, the longer/larger you should make the tunnel shielding entrance and exit. A UV Radiometer should be used to analyze light leaks for potential operator hazards. Safe retrofit of UV curing equipment onto this conveyor is the responsibility of the end user. This document provides information about a product distributed by UV Process Supply, Inc ("the Seller"). The information provided in this document is offered in good faith and is believed to be reliable, but is made WITHOUT WARRANTY, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR ANY OTHER MATTER. This document is not intended to provide advice (technical, legal or otherwise) for a particular set of facts, but is of a general nature. Users of this document should consult with their own advisors and appropriate sources. The Seller and its employees do not assume any responsibility for the user's compliance with any applicable instructions, laws or regulations, nor for any persons relying on the information contained in this document. All risk arising out of the performance of this product and/or the understanding of its usage remains solely with the Buyer. In no event shall the Seller be held liable for lost profits, lost savings, incidental or direct damages or other economic consequential damages regardless of any statement, expressed or implied, of such liability by the Seller's employees or any of its authorized agents. In addition, the Seller and its suppliers will be held harmless for any damages claimed on behalf of any third party. The Buyer of this product accepts full responsibility and understanding for the terms and specifications set forth herein. Page 5 of 5