ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

Similar documents
IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

IMMERSION. imagination at work. Retrofit Installation Guide. GE Lighting. LED Refrigerated Display Lighting

IMMERSION. imagination at work. LED Refrigerated Display Lighting. Vertical Cases RV40 Series LED Drivers GEPS4000NCMUL-SY

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Specification Grade Contemporary Wall Mount/Technical Installation Data

INSTALLATION GUIDE Works in double and single ended wiring.

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

INSTALLATION INSTRUCTIONS

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Captivate Illuminated Mirror Light

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

Wet Rated Batten LED Luminaire

Horticulture Batten LED Luminaire

Lumination TM LED Luminaire LUR Series

LED Recessed Troffer Retrofit Kit

MAXLITE RKT LED Retrofit Kit

MOONRING 1.5 MOONRING 3

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Anthony LED Lighting System Retrofit Installation Instructions For Models 101X and 101A

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Optimax Pro Retrofit Instructions

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

WARNING / AVERTISSEMENT

Cable Cubby 1202 and 1402 Installation Guide

VR44-MU-xxx-8yy-xxxxA

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

LUNERA T8 LED RETROFIT KITS 1/2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Quick Installation Guide. Affinium LED Modules LFM300 for Refrigerated Display Cases

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

GETTING STARTED WITH IN-WALL DIMMER SWITCH

UNPACKING THE UNIT. Alcohol cleaning pad



INSTALLATION INSTRUCTIONS

LED Utility Wrap Fixture

Assembly Instructions Retrofitting

VR22-MU-xxx-8yy-xxxxA

Cable Cubby 650 UT Installation Guide

P

VR44-MU-xxx-8yy-xxxxA

Installation Guide for EcoBrite EndLite LED Light Fixtures

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Parent s Guide. This guide contains important information. Please keep it for future reference US

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

LAL SERIES LED LUMINAIRE

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Learn & Discover Driver TM

PDX and PX Retrofit Series

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

User s Manual. Cruise & Learn CarTM VTech Printed in China US

User s Manual ATTILA THE ANKYLOSAURUS TM VTech Printed in China US

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Cable Cubby 1200 and 1400 Installation Guide

INSTALLATION INSTRUCTION Bollard Light 12V

W9740. fisher-price.com. 2 Ride. 1 Sit. 3 Walk

W9740. Ride. Sit. Walk. fisher-price.com

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

User s Manual HORNS THE TRICERATOPS TM VTech Printed in China US

CHARGING FOLIO. for iphone 6 USER GUIDE


CONTENTS DESCRIPTION UNPACKING DIMENSIONS

INSTALLATION INSTRUCTION Magnetic Transformer

LM79 LM80 L70:5+ YEARS

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

User s Manual. Clementine s Kitchen & Ice Cream Cart VTech Printed in China US. 500 IM_US.indd 1 08/05/ :48:5

User s Manual. 3-in-1 Launch & Play Raceway TM VTech Printed in China

LUNERA T8 LED RETROFIT KITS 2/3/4-Lamp Replacement Kits for 2FT or 4FT T8 Fluorescent Lamps

An Urgent Bulletin from CSA Group

Parent s Guide Mickey Ramps Fun House

Press the buttons for fun sounds and music! fisher-price.com

RAPID SHUTDOWN COMBINER

IMPORTANT: SAFETY INSTRUCTIONS

P Volt Charger Each sold separately and subject to availability.

Go! Go! Smart Friends

V9961 V9961

poollux Power plx-pw60 & plx-pw100

User s Manual BRONCO THE RC TRICERATOPS VTech Printed in China US

Powerware Vdc Extended Battery Cabinet User s Guide.

User s Manual VTech Printed In China US CA Manual new.indd /6/6 10:41:57

UB-2 2 Universal Button

Installation Instructions

Please keep this instruction sheet for future reference, as it contains important information. Requires three AA batteries for operation (included).

T

User s Manual. Wave to Me Magic Wand. Years. Disney. Visit DisneyJunior.com VTech Printed in China US F.P.

Transcription:

GE Lighting Immersion TM Elite LED Refrigerated Display Lighting End Mullion Lights for Vertical Cases Installation Guide ELV1abbccd-e Prefix: EL = Elite V = Vertical FD = French Door 1 = Generation Light Output Class: E = Eco Output S = Standard Output P = Premium Output Length in inches: 0 = 0 inches 8 = 8 inches 60 = 60 inches 67 = 67 inches Color Temperature: 0 = 000K White 5 = 500K White 0 = 000K White 5 = 500K White 50 = 5000K White Optic Configuration: C = Center R = Right L = Left Packaging: S = Single = ulk # = Custom FOR YOUR SAFETY EFORE YOU EGIN Read these instructions completely and carefully. Read and observe all CAUTIONS and WARNINGS shown throughout these instructions. Installation to be performed by factory trained service personnel only. For use inside a commercial refrigeration case with packaged foods only. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. efore installing, servicing or cleaning unit, switch power off at the service panel and follow appropriate lock out/tag out safety procedures imagination at work 1

Prepare Electrical Wiring Electrical Requirements The power supply must be supplied with 100-0 VAC, 50/60 Hz, and connected to an individual properly grounded branch circuit, protected by a 15 or 0 ampere circuit breaker or time delay fuse. Wiring must be wire with ground and rated for 75 C (167 F). Do not overload driver. Follow loading guidelines on page 6 of this installation guide. Ensure that all connection points are sealed for damp location using the appropriate method per the NEC or local electrical code. Led Driver Compatibility This system is compatible with GEPS61000NCCON-SY, GEPS6500NCMUL-SY, GELP-100U-GL, and GELP-60U-GL LED Drivers. Please refer to the separate LED driver installation guide for appropriate wiring connections. Tools Required Components Required 1 1 5 6 7 1 Wire stripper/cutter Tape measure Screwdriver Cordless drill 5 6 7 Hammer 7/6-inch (.8mm) drill bit Center punch 1 LED light -volt/100-watt or -volt/50-watt LED driver 6- x 1/" screws UL certified -1 AWG (0.-.08 mm ) wire connectors Parts Needed Per Case 6-Door 5-Door -Door -Door -Door Center LED Lights 5 1 End LED Light Sets 1 1 1 1 1 Wire Covers 7 6 5 Using GEPS6500NCMUL-SY & GELP-60U-GL LED Drivers LED Drivers (0-inch LED Lights) 1 1 1 1 LED Drivers (60-inch LED Lights) 1 1 LED Drivers (67-inch LED Lights) 1 1 LED Drivers (8-inch LED Lights) 1 1 1 Using GEPS61000NCCON-SY & GELP-100U-GL LED Drivers LED Drivers (0-inch LED Lights) 1 1 1 1 1 LED Drivers (60-inch LED Lights) 1 1 1 1 1 LED Drivers (67-inch LED Lights) 1 1 1 1 LED Drivers (8-inch LED Lights) 1 1 1 1 1

1 - Remove Existing Lighting Components CAUTION/ATTENTION Risk of injury. While performing installations described, gloves, safety glasses or goggles should be worn. / Risque de blessure. Lors de l'exécution des installations décrites, des gants, des lunettes de sécurité ou des lunettes de protection doivent être portées. WARNING/AVERTISSEMENT Risk of electrical shock. Disconnect power before servicing or installing product. LED Retrofit Kit Installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Contact a qualified electrician. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings. / Risque de choc électrique. Couper le courant avant de réparer ou installer le produit. LED Retrofit Kit d installation nécessite la connaissance des systèmes luminaires électriques. Si vous n êtes pas qualifié, ne tentez pas l installation. Contactez un électricien qualifié. Installez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions figurant sur les photographies et / ou des dessins. Refer to manufacturing manual for refrigeration case to identify lighting control circuits. Ensure that power is switched off at the service panel for the lighting circuit. If a lighting power switch is not provided in the refrigeration case, power removal can be performed at the main breaker panel. Please refer to refrigeration manual for any questions dealing with component locations. Lamp guards Fluorescent tubes Leave wire in place Remove lampholders 1 Turn off power to the refrigeration case. Remove all lamp guards and fluorescent tubes from inside the case. Inside the case, cut wires as close as possible to lampholders and remove them. Remove ballast Leave existing wiring Possible ballast locations: - Over door frame - Inside mullion - ehind raceway Locate ballast and remove access cover. NOTE: Refer to the refrigeration manual for specific ballast location. 5 Disconnect wires to ballast and remove from case. Leave the existing ballast input and output wires for reconnection in a later step. NOTE: Follow all federal and local regulations when disposing of fluorescent tubes, transformers and ballasts.

- Install End LED Lights WARNING/AVERTISSEMENT Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Check for enclosed wiring and components. / Risque de feu ou électrocution. Les pièces et câbles électriques risquent d être endommagés lors du perçage des trous pour l installation du luminaire à DEL. Veuillez vérifier si des câbles et composantes se trouvent derrière la paroi avant de percer. To prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other sharp objects. / Pour éviter l'endommagement de câblage ou l'abrasion, ne pas exposer le câblage aux bords de feuilles de métal ou d'autres objets tranchants. WARNING/AVERTISSEMENT Risk of electrical shock. Only those open holes indicated in the photographs and/or drawings may be made or altered as a result of kit installation. Do not leave any other open holes in an enclosure of wiring or electric components / Risque de choc électrique. Seuls les trous ouverts indiqués dans les photos et / ou les dessins peuvent être faites ou modifiés à la suite du montage du kit. Ne pas laisser autres trous ouverts dans l'enceinte du câblage électrique ou composants. Wires to old ballast -1/8" (5 mm) minimum from top of mullion L1 Use center punch and hammer to create a dimple over the two marked locations. 1-/" (8mm) Total width of mullion 1 Mark two hole locations on mullion. LED Light Length L1 0" 7.0" 8" 6.5" 60" 58.09" 67" 65.19" Use a 7/6" (.8 mm) bit to drill mounting holes through the two marked locations. NOTE: Refer to the manufacturing manual for door frame to ensure there are no components contained inside the mullion that could be drilled through.

Top view of refrigeration case Shelf Left Light Center Light Right Light End Mullion Center Mullion End Mullion Glass Door Glass Door IMPORTANT: efore proceeding, verify correct orientation of lights. Attach LED light to mullion using #6- x 1/" sheet metal screws (top and bottom). OPTIONAL: Additional screws can be used in the holes along the length of the bar if desired. Refer to the manufacturer manual for door frame to ensure there are no components contained inside the mullion that could be drilled through. 5 Refer to wiring diagram on page 7. Connect the red and black output wires from the LED light to the red and black wires that will connect to the LED driver using wire connectors or other connection method approved for low temperature usage and stranded cable. 6 7 8 Install wire covers. Repeat steps 1 6 for the other side of the case. Proceed to section Electrical Connections to complete wiring connections. Mount the LED driver in the same location where the ballast was formerly installed. NOTE: Refer to the "Parts Needed Per Case" table on page to determine the proper number of LED drivers to install. 5

- Electrical Connections Maximum LED Driver Loading CAUTION/ATTENTION Risk of injury. Do not overload LED Driver. Do not exceed limits shown in Maximum LED Driver Loading table below. Risque de blessure. Ne pas surcharger l'alimentation. Ne pas exéder les limites de la table cidessous: Charges maximales pour les alimentations. Tier Eco Standard Premium Length 0" 8 60 67 0" 8 60 67 0" 8 60 67 ar Type Light ar Power (W) LED Drivers: GEPS6500NCMUL-SY GELP-60U-GL Minimum Loading QTY (Min loading > 0W) Maximum Loading QTY (Max loading ~ 7W) LED Drivers: GEPS61000NCCON-SY GELP-100U-GL Minimum Loading QTY (Min loading > 0W) Maximum Loading QTY (Max loading ~ 95W) Center.08 5 11 10 1 End.6 8 17 15 Center 7.9 6 6 11 End 5. 9 8 16 Center 10.1 5 8 End 5. 9 8 16 Center 10.1 5 8 End 6.7 7 7 1 Center 6.1 7 7 1 End.08 5 11 10 1 Center 1. 6 End 7.9 6 6 11 Center 16.8 5 End 10.6 8 Center 16.8 5 End 10.6 8 Center 7.9 5 5 11 End 5.8 8 7 16 Center 16.8 5 End 10.1 5 8 Center 0. 1 End 1. 6 Center.5 1 End 1. 6 6

Electrical Connection Configurations Multiple LED light s electrical input should be in parallel connection to an LED driver s output as shown by the example wiring diagram. Refer to Maximum LED Driver Loading table on page 6 to determine maximum number of LED lights per LED driver. NOTE: LED lights are polarity insensitive. One End Set (Right and Left) and One Center LED Light SWITCH R R R LEFT END LED LIGHT CENTER LED LIGHT RIGHT END LED LIGHT W LED DRIVER R C G Gray Purple Occupancy Sensor WHITE (NEUTRAL) LACK (LINE) TERMINAL LOCK (AC SOURCE) 7

Connecting a GEPS6100CCON-SY Driver Make input and output connections according to diagrams below. Connection methods should be approved for low temperature usage and standed cable. For non-dimming applications, cap the unused wires with 5/ (mm) twist on wire connectors. For dimming applications, cut the dimming loop on the driver output side and make connections to the occupancy sensor. Caution: DO NOT apply voltage or power to the switched control circuit contact closure only. Other methods for automated control such as occupancy sensors that switch the AC power side on and off are not recommended and will void the product warranty. Output LED AC line Input GEPS6100NCCON-SY Dimming OPTIONAL: Enable dimming by cutting loop Occupancy Sensor Option A or Option C or D Ground L Molex Connector Molex Connector + N Gray Purple A Connect DC output using -way connector. Wire Cavity Table 9-01-00 (AC) Cavity 1 - Line 1 (lack) Cavity - Earth Ground (Green) Cavity - Neutral or Line (White) C Connect DC output using -way connector. Wire Cavity Table Molex 9-01-06 (DC) Cavity 1 - Output DC (+) (Red) Cavity - Output DC (-) (lack) Cavity - Dimming (Purple) Cavity - Dimming (Gray) N L + Ground Gray Purple Connect AC input using wire nuts. D Connect DC output using wire nuts. 8

Connecting a GEPS6500NCMUL-SY Driver Make input and output connections according to diagrams below. Connection methods should be approved for low temperature usage and standed cable. For non-dimming applications, cap the unused wires with 5/ (mm) twist on wire connectors. For dimming applications, slide the dimming switch to the left and make connections to the occupancy sensor. Caution: DO NOT apply voltage or power to the switched control circuit contact closure only. Other methods for automated control such as occupancy sensors that switch the AC power side on and off are not recommended and will void the product warranty. LED AC line Input Output GEPS6500NCMUL-SY OPTIONAL: Enable dimming by sliding switch to left Dimming Occupancy Sensor Option A or Option C or D Ground L Molex Connector Molex Connector + N Gray Purple A Connect DC output using -way connector. Wire Cavity Table 9-01-00 (AC) Cavity 1 - Line 1 (lack) Cavity - Earth Ground (Green) Cavity - Neutral or Line (White) C Connect DC output using -way connector. Wire Cavity Table Molex 9-01-06 (DC) Cavity 1 - Output DC (+) (Red) Cavity - Output DC (-) (lack) Cavity - Dimming (Purple) Cavity - Dimming (Gray) N L + Ground Gray Purple Connect AC input using wire nuts. D Connect DC output using wire nuts. 9

Cleaning Instructions WARNING/AVERTISSEMENT Risk of electrical shock. Disconnect power to LED Lights before any cleaning operation. Risque de choc électrique. Débranchez l'alimentation des éclairages à LED avant toute opération de nettoyage. The outer lens should be cleaned periodically with a mild liquid dish detergent. Do not use chemical cleaners to clean the lens. Keep the outside clean. Wipe with a clean cloth lightly dampened with mild liquid dish detergent. Dry with a clean, soft cloth. Do not wipe the lens with a soiled dish cloth or wet towel. These may leave a residue that can damage the finish. Do not use scouring pads, powdered cleaners, bleach or cleaners containing bleach because these products can scratch and damage the finish. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This Class [A] RFLD complies with the Canadian standard ICES-00. /CeDEFR de la classe [A] est conforme à la NM-00 du Canada. This product is intended solely for the use of commercial refrigerated, display or case lighting and is not intended for use in any other application. www.gelighting.com GE and the GE Monogram are trademarks of the General Electric Company. All other trademarks are the property of their respective owners. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions. GE Lighting is a business of the General Electric Company. 016 GE. DISP086 (Rev 0/9/16) 10