Quintas & Quintas Group

Similar documents
OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

XLPE Cable Systems. User s guide. rev. 2

P High Voltage Catalogue Cables Australia Powering your Project

High Voltage and Extra High Voltage Cables

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

Caledonian Medium Voltage Cables

High Voltage Copper, Smooth Aluminum Shield/Sheath

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Caledonian Medium Voltage Cables

MEDIUM VOLTAGE POWER CABLES

XLPE CABLES AND CABLE SYSTEMS KV MODERN SOLUTIONS FOR POWER CABLES/ESTRALIN HVC

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

0.6/1kV Al-Cu PVC Insulated PVC Sheathed Power Cable

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

DURAREEL TRAILING REELING CABLE

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

TRATOS OIL&GAS NEK606

Global data. Electrical parameters

Your Partner in Safe Power Solutions. About RESCAB

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

FR-3S Fire Resistant Cables

CAAI-S 0,6/1 kv with Public Lighting

ACSR- ROPES Aluminium wire steel reinforced (ACSR conductor)

Company Profile. Caledonian Medium Voltage Cables

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Any inquiries, please feel free to contact or Caledonian

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

Power & Control Cable IEC

Power System Analysis I TRANSMISSION LINE PARAMETERS

Medium Voltage Power Cables

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

LIST OF PUBLISHED STANDARDS

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

Submarine Power Cables

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

600/1000V, PVC Insulated Cables according to IEC

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

North America HIGH&EXTRA-HIGH VOLTAGE UNDERGROUND SOLUTIONS

LOW VOLTAGE c a b l e s

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

Power & Control Cables

SUSPENSION 04 CLAMPS

AERIAL. a Nexans company. Australia Head Office 207 Sunshine Road Tottenham Victoria 3012 Australia Phone Cable Sales Phone 1300 CABLES

Standardization IEC /-351/-353. Conductor material

Medium voltage cables

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

Medium Voltage Cable. marmonutility.com

Pyrohalon. Cables, halogen-free, fire-retardant. Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

Technical Information

Power & Control Cable IEC

EARTH WIRE FITTINGS 08

I N T R O D U C T I O N

Power & Control Cable IEC

20 HUBER+SUHNER RADOX SOLAR

MEDIUM VOLTAGE

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

Wire. Litz. components need a dependable source for Litz. wire of the highest quality. New England Wire Technologies

Unarmoured Single-Core Cables to BS6883

GEMSCAB has been associated with marketing and manufacturing of Electric Cables

The cables you need when you need them

C-L-X Aluminum Sheath Type IEC

BS5467. Standard Power Cables. Low Voltage (600/1000 V) Cable Approvals. Conductor. Insulation. Core Identification. Bedding. Outer Sheath.

FOREWORD ONE COMPANY CONNECTING THE WORLD POWERFUL PRESENCE PRODUCTS PERFORMANCE PEOPLE

Completing the picture

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

600/1000V, XLPE Insulated Cables according to IEC

flame Retardant overall screened Instrumentation cables (Multicore)

MC or MV-105 Copper, TR-XLPE Insulated

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

POLYCAB WIRES PVT LTD TECHNICAL DETAILS. HT XLPE CABLES UPTO 45Kv

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

Telephone Cables Fire Warning Cables

MV TERMINATIONS. INDOOR SINGLE CORE TERMINATION - ELTI-1C for polymeric cables - Slip-on termination - Modular type APPLICATION STANDARDS

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

EXTRA HIGH VOLTAGE c a b l e s

CONDUCTOR Plain bright annealed copper! alluminium, solid! stranded conductor confirming to IS: 8130: INSULATION INNER SHEATH

First South East European Regional CIGRÉ Conference, Portoroz KV 2 X 1000MW SUBMARINE CABLE CROSSING OF THE DARDANELLES STRAIT IN TURKEY

UNDERGROUND TRANSMISSION SOLUTIONS PRODUCT CATALOG

New TITANEX PREMIUM. No limit!

Introduction. for over a period 4 decades now. Customer satisfaction has been the prime focus of

026-2 : 1996 CEB STANDARD

PRODUCT CATALOGUE Volume 4

FOREWORD ONE OF THE WORLD S BIGGEST COMPANIES IN THE SECTOR.

Transcription:

Electric Conductors

Quintas & Quintas Group

Index Quintas & Quintas and Solidal 2 Bare Conductors l uminium Conductors for overhead lines 3 l uminium loy Conductors for overhead lines 4 uminium Conductors Steel Reinforced for overhead lines 5 Optical Ground Wire (OPGW) for overhead lines 6 Insulated Cabes uminium Low Voltage Aerial Bundled Conductors 7 uminium or Copper Low Voltage Cables 8 uminium or Copper Medium Voltage Cables 9 uminium Medium Voltage Aerial Bundled Cables 10 uminium or Copper High Voltage Cables 11 uminium or Copper High Voltage Cables (cont.) 12 The values and other characteristics stated and this catalogue must be considered as indicative ones. For other cross sections, service voltages or particular details, please contact our services.

Quintas & Quintas and Solidal Quintas & Quintas Condutores Eléctricos SA. and Solidal Condutores Eléctricos, SA, leaders in the industry of the aluminium power conductors have as principal activity the production of bare and insulated electric conductors, their coercialization and the technical support with the assembly of the provided products. Quintas Condutores in the sector of bare electric conductors and Solidal in the insulated cables, their productions are mainly directed on aluminium products. This market segment, appeared, these last years, strongly challenging, which is mainly due to the increasing aggressiveness from the manufacturing companies. However, Quintas Condutores in the market of bare cables and Solidal in insulated cables are leaders of the sector. The two companies followed a strategy based on two orientations: to carry out a progressive vertical integration, increasing, thus, the level of the added value of the products that they sell and to remain updated from the technological point of view, while they invest regularly in advanced technology equipment and productivity and simultaneously in Technical Boards of recognized rename and their adequate formation. Nowadays Quintas & Quintas and Solidal have all the equipment and know-how necessary to the industrial process, to produce and transform the conductors indicated hereafter: Quintas & Quintas. Bare uminium cables: Solid conducting conductors, round form or sectoral; Conducting conductors multiwire, round form or sectoral.. Cables for Bare Aerial lines: uminium cables AAAC (l uminium Conductors); uminium alloy cables AAAC (l uminium loy Conductors); uminium cables with alloy ACAR conductor (uminium Conductors loy Reinforced); uminium cables with steel ACSR conductor (uminium Conductors Steel Reinforced); uminium cables with ACS ACSR/AW conductor (uminium Conductors ACS Reinforced); loy cables with steel AACSR conductor (uminium loy Conductors Steel Reinforced); Guard cables with optical fibre OPGW (Optical Power Ground Wire). Solidal. Insulated cables: The production in the sector of insulated conductors covers the range of the aerial and underground cables of Low, Medium and High Voltage. Main conductor types: Low Voltage Cables (0,6/1 kv) - Sections of 16 2 up to 800 2 (with rigid conductors, multiwire, round or sectoral, of aluminium) - Sections of 54,6 and 80 2 (with conductors multiwire, of aluminium alloy, melec) Medium Voltage Cables (6 to 36 kv) - Sections of 35 2 up to 1000 2 insulated with dielectric extruded solid, by triple simultaneous extrusion, with conducting conductors multiwire of aluminium or copper, with reticulation in atmosphere of inert gas. High Voltage Cables (up to 150 kv) - Sections of 120 2 up to 1600 2 insulated with the dielectric extruded solid, in triple simultaneous extrusion, with conducting conductors multiwire of aluminium or copper, possibly with elements of stuffing of longitudinal and radial sealing, with reticulation in an dry atmosphere. The aluminium used in the manufacture of the cables has a high degree of purity, never inferior than 99,7%. 2

l uminium Conductors for overhead lines Construction: This bare concentric-lay stranded conductor is constructed with a straight round central wire surrounded by one or more layers of helically wires. Applications: The aluminum alloy cables are used normally in overhead lines. Standards: EN 50 889; EN 50 182 Electrical and dimensional characteristics of uminum Conductors AL1 Designation Area Diameter () Mass per unit length Rated strength DC resistance at 20 0 C Final Modulus of Elasticity Coefficient of linear Expansion Code Old code 2 wire Cond. kg/km kn /km N/ 2 1/K A 25-AL1 25/7 25.2 7 2,14 6.42 68.8 4.53 1.1350 60000 23.0E-6 145 Continuous loading capacity (1) 34-AL1 35/7 34.4 7 2.50 7.50 93.9 6.01 0.8317 60000 23.0E-6 175 49-AL1 50/7 49.5 7 3.00 9.00 135.2 8.41 0.5776 60000 23.0E-6 225 68-AL1 70/19 68.3 19 2.14 10.70 187.8 12.30 0.4205 57000 23.0E-6 275 93-AL1 95/19 93.3 19 2.50 12.50 256.3 16.32 0.3081 57000 23.0E-6 335 125-AL1 120/9 125.5 19 2.90 14.50 344.9 21.33 0.2290 57000 23.0E-6 405 244-AL1 240/37 244.4 37 2.90 20.3 674.0 41.56 0.1180 57000 23.0E-6 625 491-AL1 500/61 490.6 61 3.20 28.8 1357.4 80.95 0.0590 55000 23.0E-6 980 767-AL1 800/61 766.5 61 4.00 36.0 2120.9 122.65 0.0377 55000 23.0E-6 1310 Note: Direction of lay of external layer is right-hand (Z). (1) - Reference values valid up to 50 Hz at a wind speed of 0,6 m/s and solar irradiation giving an initial ambient temperature of 35 C and a final conductor temperature of 80 C. Compositions 7 wires 19 wires 37 wires 61 wires 3

l uminium loy Conductors for overhead lines Construction: This bare concentric-lay stranded conductor is constructed with a straight round central wire surrounded by one or more layers of helically wires. Applications: Used as bare overhead conductor for primary and secondary distribution. Designed utilizing a high strength aluminum alloy to achieve a high strength-to-weight ratio; affords better sag characteristics. uminum alloy gives AAAC higher resistance to corrosion than ACSR. Standards: EN 50 183; EN 50 182 Electrical and dimensional characteristics of uminum loy Conductors - AL3 Designation Area Diameter () Mass per unit length Rated strength DC resistance at 20 0 C Final Modulus of Elasticity Coefficient of linear Expansion Code Old code 2 loy wire Cond. kg/km kn /km N/ 2 1/K A 35-AL3 35/7 34.9 7 2.52 7.56 95.3 10.30 0.9421 60000 23.0E-6 165 Continuous loading capacity (1) 49-AL3 50/7 49.5 7 3.00 9.00 135.1 14.60 0.6647 60000 23.0E-6 210 68-AL3 70/19 68.3 19 2.14 10.70 187.6 20.16 0.4840 57000 23.0E-6 260 95-AL3 95/19 94.8 19 2.52 12.60 260.2 27.96 0.3490 57000 23.0E-6 320 125-AL3 120/19 125,5 19 2.90 14.50 344.5 37.02 0.2636 57000 23.0E-6 385 147-AL3 150/37 147.1 37 2,25 15.8 405.3 43.40 0.2256 57000 23.0E-6 425 185-AL3 185/37 184.5 37 2.52 17.6 508.4 54.44 0.1799 57000 23.0E-6 490 196-AL3 200/37 196.4 37 2.60 18.2 541.2 57.95 0.1690 57000 23.0E-6 510 244-AL3 240/37 244.4 37 2,90 20.3 673.3 72.10 0.1358 57000 23.0E-6 590 304-AL3 300/61 304,2 61 2.52 22.7 840.8 89.75 0.1094 55000 23.0E-6 680 403-AL3 400/61 402.9 61 2,90 26.1 1113.6 118.86 0.0826 55000 23.0E-6 815 Note: Direction of lay of external layer is right-hand (Z). (1) - Reference values valid up to 50 Hz at a wind speed of 0,6 m/s and solar irradiation giving an initial ambient temperature of 35 C and a final conductor temperature of 80 C. Compositions 7 wires 19 wires 37 wires 61 wires 4

uminum Conductors Steel Reinforced for overhead lines Construction: ACSR is a concentrically stranded conductor composed of one or more layers of aluminum wire stranded with a high strength coated steel core. The core may be single wire or stranded depending on the size. The proportions of aluminum and steel can be varied to obtain the relation between current-carrying capacity and mechanical strength best suited to each application. Additional corrosion protection is available through the application of grease to the core or infusion of the complete cable with grease. Applications: Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. Standards: EN 50 189; EN 50 889; EN 50 182 Electrical and dimensional characteristics of uminum Conductors Steel Reinforced - AL1/ST1A Code Designation Areas ( 2 ) Wire Diameter () Diameter () Old code Steel Total Steel Steel Core Cond. Mass per unit length Rated strength kg/km kn DC resistance at 20 C /km Final Modulus of Elasticity N/ 2 Coefficient of linear Expansion 1/K 42-AL1/7-ST1A 42/6+1 42,4 7,1 49,5 6 1 3,00 3,00 3,00 9,00 171,2 15,27 0,6757 76000 18,6E-6 205 68-AL1/39-ST1A 68/12+7 67,7 39,5 107,2 12 7 2,68 2,68 8,04 13,40 495,8 56,52 0,4266 104000 15,3E-6 290 128-AL1/21-ST1A 128/26+7 127,6 20,9 148,5 26 7 2,50 1,95 5,85 15,9 516 46,79 0,2263 73000 18,6E-6 420 191-AL1/31-ST1A 191/26+7 191,2 31,1 222,3 26 7 3,06 2,38 7,14 19,4 771,6 67,05 0,151 73000 18,9E-6 545 212-AL1/49-ST1A 212/30+7 212,1 49,5 261,6 30 7 3,00 3,00 9,00 21,0 973,1 92,46 0,1363 80000 17,9E-6 585 265-AL1/43-ST1A 265/26+7 264,6 43,1 307,7 26 7 3,60 2,80 8,40 22,8 1068 91,48 0,1091 73000 18,9E-6 675 349-AL1/79-ST1A 349/30+19 349,2 78,9 428,1 30 19 3,85 2,30 11,50 26,9 1585,7 145,87 0,0828 79000 18,0E-6 810 382-AL1/49-ST1A 382/54+7 381,7 49,5 431,2 54 7 3,00 3,00 9,00 27,0 1442,5 121,3 0,0758 70000 19,4E-6 850 416-AL1/93-ST1A 416/30+19 415,6 93,3 508,9 30 19 4,20 2,50 12,50 29,3 1881,8 172,82 0,0696 79000 18,0E-6 910 434-AL1/56-ST1A 434/54+7 434,3 56,3 490,6 54 7 3,20 3,20 9,60 28,8 1641,3 133,59 0,0666 70000 19,4E-6 925 520-AL1/66-ST1A 520/54+19 519,5 65,8 585,3 54 19 3,50 2,10 10,50 31,5 1952,1 162,72 0,0556 70000 19,5E-6 1040 629-AL1/79-ST1A 629/54+19 628,6 78,9 707,5 54 19 3,85 2,30 11,50 34,6 2356,6 190,58 0,046 70000 19,5E-6 1175 748-AL1/93-ST1A 748/54+19 748,1 93,3 841,4 54 19 4,20 2,50 12,15 37,7 2799,3 226,03 0,0386 70000 19,5E-6 1315 859-AL1/109-ST1A 858/54+19 858,8 108,8 967,6 54 19 4,50 2,70 13,50 40,5 3226,9 261,43 0,0337 70000 19,5E-6 1440 Continuous loading capacity (1) A Note: Direction of lay of external layer is right-hand (Z). (1) - Reference values valid up to 50 Hz at a wind speed of 0,6 m/s and solar irradiation giving an initial ambient temperature of 35 C and a final conductor temperature of 80 C. Compositions 6/1 wires 12/7 wires 26/7 wires 30/7 wires 54/7 wires 5

uminium Low Voltage Aerial Bundled Conductors Voltage 0,6/1 kv Construction: Round stranded and compacted aluminium conductors (phases/neutral). uminium alloy messengers (neutral conductor) in several cross sections, namelly 54,6, 70, 80 and 95 2 can also be included in the bundle. XLPE Insulation, UV resistant Applications: The aluminium aerial bundled conductors are mainly used for the low voltage distribution networks, namely in the rural or suburban areas, due to several specific advantages, like: - good network performance (low failure rate) - possibility to perform repairs and interventions in the lines under tension - reduced installation cost - reduced forest fire risk - particulary suitable for heavily polluted environments - good resistance to acid rain salt spray Standards: HD 626 S1; NFC 33-209 Electrical and dimensional characteristics of the Aerial Bundled Conductors Designation Diameter of conductor (aprox.) Phase Neutral Insulation thickness Phase Neutral Diameter on insulation (aprox.) Phase Neutral Bundle Diameter (aprox.) Weight (aprox. DC resistance at 20º0 C Phase Neutral rrent Rating (1) Voltage drop cos = 0,8 2 kg/km /km A V/A.km Aerial Bundled Aerial Bundled (uminium alloy neutral) 2x16 4,8 4,8 1,2 1,2 7,4 7,4 14,8 134 1,91 1,91 93 3,98 2x16+2x1,5 4,8 4,8 1,2 1,2 7,4 7,4 16,8 175 1,20 1,20 93 3,98 2x25 6,0 6,0 1,4 1,4 9,0 9,0 18,0 203 1,91 1,91 122 2,54 2x25+2x1,5 6,0 6,0 1,4 1,4 9,0 9,0 20,0 244 1,20 1,20 122 2,54 4x16 4,8 4,8 1,2 1,2 7,4 7,4 17,9 268 1,91 1,91 83 3,44 4x16+2x1,5 4,8 4,8 1,2 1,2 7,4 7,4 19,9 309 1,91 1,91 83 3,44 4x25 6,0 6,0 1,4 1,4 9,0 9,0 21,8 406 1,20 1,20 111 2,20 4x25+2x1,5 6,0 6,0 1,4 1,4 9,0 9,0 23,8 447 1,20 1,20 111 2,20 3x35+54,6 7,0 9,5 1,6 1,6 10,4 10,4 33,0 625 0,868 0,63 138 1,65 3x35+54,6+1x16 7,0 9,5 1,6 1,6 10,4 10,4 33,0 692 0,868 0,63 138 1,65 3x35+54,6+2x16 7,0 9,5 1,6 1,6 10,4 10,4 33,0 759 0,868 0,63 138 1,65 3x35+54,6+3x16 7,0 9,5 1,6 1,6 10,4 10,4 33,0 827 0,868 0,63 138 1,65 3x70+54,6 9,8 9,5 1,8 1,6 13,6 13,2 38,0 963 0,443 0,63 213 0,87 3x70+54,6+1x16 9,8 9,5 1,8 1,6 13,6 13,2 38,0 1030 0,443 0,63 213 0,87 3x70+54,6+2x16 9,8 9,5 1,8 1,6 13,6 13,2 38,0 1097 0,443 0,63 213 0,87 3x70+54,6+3x16 9,8 9,5 1,8 1,5 13,6 13,0 38,0 1164 0,443 0,63 213 0,87 3x70+70 9,8 10,2 1,8 1,5 13,6 13,0 41,0 996 0,443 0,50 213 0,87 3x70+70+1x16 9,8 10,2 1,8 1,5 13,6 13,0 41,0 1063 0,443 0,50 213 0,87 3x70+70+2x16 9,8 10,2 1,8 1,5 13,6 13,0 41,0 1130 0,443 0,50 213 0,87 3x70+70+3x16 9,8 10,2 1,8 1,5 13,6 13,0 41,0 1197 0,443 0,50 213 0,87 3x150+70 14,5 10,2 1,7 1,5 18,1 17,7 48,0 1688 0,206 0,50 344 0,46 3x150+70+1x16 14,5 10,2 1,7 1,5 18,1 17,7 48,0 1755 0,206 0,50 344 0,46 3x150+70+2x16 14,5 10,2 1,7 1,5 18,1 17,7 48,0 1822 0,206 0,50 344 0,46 3x150+70+3x16 14,5 10,2 1,7 1,5 18,1 17,7 48,0 1889 0,206 0,50 344 0,46 (1) The maximum beareable current values are refered to the following condictions: - Permanent working condictions - Temperature of in open air 30 C Rating Factors: Ambient air temperature 10 15 20 25 30 35 40 45 50 60 70 Coefficient 1,17 1,13 1,09 1,04 1,00 0,95 0,91 0,85 0,8 0,67 0,52 7

uminium or Copper Low Voltage Cables Construction: uminium conductors (solid/stranded, round/sector shaped) XLPE insulation. Polyester assembling tape PVC bedding (armoured cables) Double helix tape (multi core armoured cables) or aluminium tape (single core cables) PVC outer sheath (LDPE sheath supplied on request) Applications: Power plants, underground distribution networks, industrial plants. The solid conductor cables are particulary suitable for the low voltage circuits, between the transformers and main distribution boards. The cables can be installed in ducts or open air (the armoured versions are generally used in undergruond circuits, directly buried in the soil). Voltage 0,6/1 kv Standards: HD 603 S1; IEC 60502-1 Electrical and dimensional characteristics of Low Voltage Cables Designation Diameter of conductor Insulation thickness Phase Neutral Diameter on insulation Diameter of cable Weight DC resistance at 20 0 C rrent Rating (1) air underground Voltage drop cos = 0,8 2 kg/km /km A V/A.km 1 Core 3 Cores/Neutral 4 Cores 1x16 4,80 0,7-6,4 9,4 110 1,910-105 3,50 1x25 6,00 0,9-8,0 11,0 155 1,200 180 135 2,24 1x35 7,00 0,9-9,0 12,0 190 0,868 215 166 1,65 1x50 8,10 1,0-10,3 13,3 240 0,641 257 205 1,29 1x70 9,80 1,1-12,2 15,2 320 0,443 315 260 0,88 1x95 11,40 1,1-13,8 17,0 410 0,320 377 321 0,66 1x120 13,00 1,2-15,6 18,8 505 0,253 430 375 0,54 1x150 14,50 1,4-17,5 20,9 615 0,206 482 432 0,46 1x185 16,40 1,6-19,8 23,2 750 0,164 545 500 0,38 1x240 18,50 1,7-22,1 25,7 950 0,125 640 603 0,32 1x300 20,80 1,8-24,6 28,4 1.185 0,100 725 697 0,27 1x400 23,60 2,0-27,8 31,8 1.490 0,078 835 829 0,22 1x500 26,80 2,2-31,4 35,8 1.850 0,061 950 963 0,19 1x630 30,60 2,4-35,6 40,4 2.310 0,125 1.035 1.050 0,16 3x35/16 7,00 0,9 0,7 9,0 23,3 675 0,868 134 122 1,63 3x50/25 8,10 1,0 0,9 10,3 26,0 862 0,641 160 149 1,22 3x70/35 9,80 1,1 0,9 12,2 30,2 1.176 0,443 197 192 0,87 3x90/50 11,40 1,1 1,0 13,8 34,0 1.546 0,320 234 235 0,65 3x120/70 13,00 1,2 1,1 15,6 37,8 1.911 0,253 266 273 0,53 3x150/70 14,50 1,4 1,1 17,5 41,5 2.312 0,206 300 316 0,45 3x185/95 16,40 1,6 1,1 19,8 46,3 2.869 0,164 337 363 0,37 3x240/120 18,50 1,7 1,2 22,1 52,0 3.692 0,125 388 430 0,30 4x35 7,00 0,9 0,9 9,0 23,3 686 0,868 134 122 1,63 4x50 8,10 1,0 1,0 10,3 26,2 882 0,641 160 149 1,22 4x70 9,80 1,1 1,1 12,2 30,6 1.214 0,443 197 192 0,87 4x95 11,40 1,1 1,1 13,8 34,0 1.568 0,320 234 235 0,65 4x120 13,00 1,2 1,2 15,6 38,0 1.951 0,253 266 273 0,53 4x150 14,50 1,4 1,4 17,5 41,7 2.379 0,206 300 316 0,45 4x185 16,40 1,6 1,6 19,8 46,5 2.971 0,164 337 363 0,37 4x240 18,50 1,7 1,7 22,1 52,2 3.805 0,125 388 430 0,30 (1) The maximum beareable current values are refered to the following condictions: - Permanent working condictions - Temperature of in open air 30 C - Temperature of the ground 20 C - Depth of installation from 0,70 to 1,0 meter. 8

uminium or Copper Medium Voltage Cables Voltage 6/10 (12) kv 12/20 (24) kv 18/30 (36) kv Construction de base: Round stranded and compacted aluminium or copper conductors. Inner semi-conducting layer. XLPE or HEPR insulation. Outer semi-conducting layer (strippable or full bonded ). Metallic screen (copper wires/copper tape). Non-metallic outer sheath (PVC or PE). Construction options: Conductor water blocking (water swellable yarns). Radial water blocking (water swellable tape). uminium tape armoured (single core cables) or steel tape armour (three core cables). Outer sheath: - Halogen free flame retardant - Co-extruded conductive layer over the sheath for special sheath testing Applications: Medium voltage transport and distribution networks, industrial plants, power plants, transformer units, connection between overhead lines and transformers. The cables can be installed in ducts, galleries, directly buried in the soil or in the open air. The armoured versions are particulary suitable to be directly buried in the soil, when an extra mechanical protection is needed. Standards : IEC 60502-2; HD 620 Electrical and dimensional characteristics of the Cables (no armoured) Cross section Diameter of conductor Insulation thickness Diameter over insulation Outer Sheath thickness Outer diameter of cable Approx. weight (kg/km) Capacitance C Inductance L Reactance XL Impedance Z 90ºo C ( /km) 2 μf/km mh/km /km Voltage 6/10 kv Voltage 12/20 kv Voltage 18/30 kv 35 7,0 15,9 1,8 22,0 540 755 0,23 0,399 0,125 1,12 0,68 50 8,1 17,0 1,8 23,1 605 900 0,25 0,381 0,120 0,83 0,50 70 9,8 18,7 1,8 24,8 710 1.130 0,29 0,362 0,114 0,36 0,36 95 11,4 20,3 1,8 26,4 825 1.405 0,32 0,347 0,109 0,42 0,27 120 13,0 21,9 1,8 28,0 940 1.670 0,35 0,337 0,106 0,34 0,22 150 14,5 3,4 23,4 1,9 29,7 1.070 1.975 0,38 0,327 0,103 0,28 0,19 185 16,4 25,3 1,9 31,6 1.225 2.350 0,41 0,320 0,101 0,23 0,16 240 18,5 27,4 2,0 33,9 1.455 2.930 0,46 0,310 0,097 0,19 0,14 300 20,8 29,7 2,1 36,4 1.720 3.560 0,50 0,300 0,094 0,16 0,12 400 23,6 32,5 2,2 39,4 2.035 4.390 0,55 0,290 0,091 0,14 0,11 500 26,8 35,7 2,3 42,8 2.435 5.520 0,62 0,281 0,088 0,12 0,10 35 7,0 20,1 1,8 26,2 720 930 0,17 0,427 0,134 1,12 0,68 50 8,1 21,2 1,8 27,3 790 1.080 0,18 0,411 0,129 0,83 0,51 70 9,8 22,9 1,8 29,0 905 1.325 0,20 0,390 0,123 0,36 0,36 95 11,4 24,5 1,9 30,8 1.045 1.625 0,22 0,376 0,118 0,43 0,27 120 13,0 26,1 2,0 32,6 1.185 1.915 0,24 0,366 0,115 0,34 0,23 150 14,5 5,5 27,6 2,0 34,1 1.310 2.210 0,26 0,355 0,111 0,29 0,19 185 16,4 29,5 2,1 36,2 1.495 2.620 0,28 0,343 0,108 0,24 0,17 240 18,5 31,6 2,1 38,3 1.725 3.200 0,31 0,331 0,104 0,19 0,14 300 20,8 33,9 2,2 40,8 2.005 3.845 0,34 0,320 0,101 0,16 0,13 400 23,6 36,7 2,3 43,8 2.340 4.695 0,37 0,309 0,097 0,14 0,12 500 26,8 39,9 2,4 47,2 2.765 5.850 0,41 0,299 0,094 0,12 0,11 35 7,0 25,1 1,9 31,4 975 1.190 0,13 0,462 0,145 1,12 0,68 50 8,1 26,2 2,0 32,7 1.070 1.360 0,14 0,444 0,140 0,83 0,51 70 9,8 27,9 2,0 34,4 1.200 1.620 0,16 0,425 0,134 0,37 0,37 95 11,4 29,5 2,1 36,2 1.350 1.930 0,17 0,407 0,128 0,43 0,28 120 150 13,0 14,5 8,0 31,1 32,6 2,1 2,2 37,8 39,5 1.490 1.650 2.220 2.550 0,19 0,20 0,392 0,380 0,123 0,119 0,35 0,29 0,23 0,20 185 16,4 34,5 2,2 41,4 1.830 2.960 0,22 0,367 0,115 0,24 0,17 240 18,5 36,6 2,3 43,7 2.100 3.575 0,23 0,354 0,111 0,20 0,15 300 20,8 38,9 2,4 46,2 2.400 4.240 0,25 0,342 0,108 0,17 0,13 400 23,6 41,7 2,5 49,2 2.760 5.115 0,28 0,330 0,104 0,14 0,12 500 26,8 44,9 2,6 52,6 3.215 6.300 0,31 0,318 0,100 0,13 0,11 Cross Section ( 2 ) DC at 20 0 C ( /km) Resistance AC at 90 0 C ( /km) Underground (1) rrent Rating (A) Voltage Drop (cos = 0,8) V/A.km 35 0,868 0,524 1,113 0,664 151 190 161 201 1,68 1,06 50 0,641 0,387 0,822 0,490 180 226 190 241 1,27 0,81 70 0,443 0,268 0,568 0,340 220 276 235 299 0,91 0,60 95 0,320 0,193 0,411 0,245 260 329 290 362 0,69 0,46 120 0,253 0,153 0,325 0,194 300 373 330 416 0,57 0,39 150 0,206 0,124 0,265 0,158 335 415 375 469 0,48 0,33 185 0,164 0,099 0,211 0,127 378 468 430 536 0,40 0,29 240 0,125 0,075 0,161 0,097 438 541 508 630 0,33 0,24 300 0,100 0,060 0,129 0,078 496 608 588 717 0,28 0,21 400 0,078 0,047 0,101 0,062 560 684 680 823 0,24 0,19 500 0,061 0,037 0,080 0,050 636 762 790 929 0,21 0,17 The currents and voltage drops are indicated for a 3 phase installation (3 cables in trefoil). (1) - Maximum temperature of the ground 20 C; (2) - Maximum temperature in open air 30 C Air (2) 9

uminium Medium Voltage Aerial Bundled Cables Construction: Round stranded and compacted aluminium or copper conductor. Inner semi-conducting layer. XLPE insulation. Outer semi-conducting layer (strippable or full bonded ). Metallic screen (copper tape). Non-metallic outer sheath (PE or PVC). Voltage 6/10 (12) kv 8,7/15 (17,5) kv 12/20 (24) kv 18/30 (36) kv Applications: The medium voltage bundled cables are particularly suitable for overhead transport and distribution networks in places were an underground network would be unrealisable (rocky soil, forest and mountain areas). This cables are also frequently used in temporary connections, as they can be easily installed and removed. The overhead bundled cables are also an ideal solition for heavily polluted ar maritime environments, and they resist rather well to frost and low temperatures. Standards: IEC 60502-2; HD 620 Electric and Dimensional characteristics of the Cables Cross section Approx. Outer Diameter () Aerial Bundled (1) rrent in open air (1) Voltage drop (1) - Manufacture for 18/30 kv under order. With 50 2 steel covered cable. Other steel wire support sections may be supplied under request. Maximum temperature in open air 30º C. (2) - rrents and voltage drops are indicated for a 3 phase installation. 10

uminium or Copper High Voltage Cables Construction: Round stranded and compacted aluminium or copper conductor (longitudinal water sealing). Inner semi-conducting layer. XLPE insulation. Outer semi-conducting layer. Metallic screen (copper wires/copper tape). Longitudinal water sealing of metallic screen. Radial water sealing (-PE laminate or -PE laminate). Non-metallic outer sheath (PE or PVC). - Halogen free flame retardant. - Co-extruded conductive layer over the sheath for special sheath testing. Rated voltage 26/45 kv 36/60 kv 64/110 kv 76/132 kv 87/150 kv Applications: High voltage transport and distribution networks, industrial plants, power plants, transformer units. The cables can be installed in ducts, galleries, directly buried in the soil or in the open air. Standards: IEC 60840; HD 632-S1 Electrical and Dimensional characteristics of the Cables Cross section of conductor Diameter of conductor Insulation thickness Diameter over insulation Metallic Screen Outer Sheath thickness Outer diameter of cable Cable weight (kg/m) Capacitance C Inductance L Short-circuit condictions ka (1 s) In conductor (1) In metal screen (2) 2 2 μf/km mh/km Voltage 87/150 kv Voltage 76/132 kv Voltage 64/110 kv Voltage 36/60 kv Voltage 26/45 kv 150 14,5 8,0 32,6 35 3,0 43,0 2,1 3,0 0,20 0,38 14,1 21,5 185 16,4 8,0 34,5 35 3,0 45,0 2,2 3,4 0,22 0,37 17,4 26,5 240 18,5 8,0 36,6 35 3,0 47,0 2,5 4,0 0,23 0,36 22,6 34,3 300 20,8 8,0 38,9 35 3,0 49,0 2,8 4,6 0,25 0,34 28,2 42,9 400 23,6 8,0 41,7 35 3,0 52,0 3,1 5,5 0,28 0,33 37,6 57,2 5,4 500 26,8 8,0 44,9 35 3,0 55,0 3,5 6,6 0,31 0,32 47,0 71,5 630 30,6 8,0 48,7 35 3,0 59,0 4,1 8,0 0,34 0,31 59,2 90,1 800 34,7 8,0 52,8 35 3,0 63,0 4,8 9,7 0,37 0,30 75,2 114,4 1000 39,3 8,0 57,4 35 3,0 68,0 5,5 11,7 0,41 0,29 94,0 143,0 150 14,5 9,0 35,0 35 3,0 46,0 2,2 3,1 0,19 0,39 14,1 21,5 185 16,4 9,0 36,9 35 3,0 48,0 2,4 3,5 0,20 0,38 17,4 26,5 240 18,5 9,0 39,0 35 3,0 50,0 2,6 4,1 0,22 0,37 22,6 34,3 300 20,8 9,0 41,3 35 3,0 52,0 2,9 4,7 0,24 0,35 28,2 42,9 400 23,6 9,0 44,1 35 3,0 55,0 3,2 5,6 0,26 0,34 37,6 57,2 5,4 500 26,8 9,0 47,3 35 3,0 58,0 3,7 6,7 0,28 0,33 47,0 71,5 630 30,6 9,0 51,1 35 3,0 62,0 4,2 8,2 0,31 0,32 59,2 90,1 800 34,7 9,0 55,2 35 3,0 66,0 4,9 9,8 0,34 0,31 75,2 114,4 1000 39,3 9,0 59,8 35 3,0 71,0 5,6 11,8 0,38 0,30 94,0 143,0 185 16,4 16,0 51,3 95 3,5 65,0 4,1 5,2 0,14 0,44 17,4 26,5 240 18,5 15,0 51,4 95 3,5 65,0 4,2 5,7 0,16 0,41 22,6 34,3 300 20,8 14,0 51,7 95 3,5 65,0 4,4 6,2 0,17 0,39 28,2 42,9 400 23,6 14,0 54,5 95 3,5 68,0 4,8 7,1 0,19 0,38 37,6 57,2 500 26,8 14,0 57,7 95 3,5 71,0 5,3 8,4 0,20 0,37 47,0 71,5 14,6 630 30,6 14,0 61,5 95 4,0 76,0 6,0 9,9 0,22 0,35 59,2 90,1 800 34,7 14,0 65,6 95 4,0 80,0 6,7 11,7 0,24 0,34 75,2 114,4 1000 39,3 14,0 70,2 95 4,0 85,0 7,6 13,7 0,27 0,33 94,0 143,0 1200 43,5 14,0 74,4 95 4,0 89,0 8,4 16,1 0,29 0,32 112,8 171,6 1600 51,0 14,0 81,9 95 4,0 97,0 10,1 20,2 0,33 0,31 150,4 228,8 240 18,5 18,0 57,4 95 4,0 72,0 4,9 6,4 0,14 0,44 22,6 34,3 300 20,8 17,0 57,7 95 4,0 72,0 5,1 6,9 0,15 0,41 28,2 42,9 400 23,6 16,0 58,5 95 4,0 73,0 5,3 7,6 0,17 0,39 37,6 57,2 500 26,8 16,0 61,7 95 4,0 76,0 5,8 8,9 0,19 0,38 47,0 71,5 14,6 630 30,6 16,0 65,5 95 4,0 80,0 6,4 10,4 0,20 0,37 59,2 90,1 800 34,7 16,0 69,6 95 4,0 84,0 7,2 12,1 0,22 0,35 75,2 114,4 1000 39,3 16,0 74,2 95 4,0 89,0 8,1 14,3 0,24 0,34 94,0 143,0 1200 43,5 16,0 78,4 95 4,0 93,0 9,0 16,7 0,26 0,33 112,8 171,6 1600 51,0 16,0 85,9 95 4,0 101,0 10,6 20,7 0,29 0,32 150,4 228,8 400 23,6 20,0 67,1 95 4,0 82,0 6,2 8,5 0,15 0,41 37,6 57,2 500 26,8 19,0 68,3 95 4,0 84,0 6,5 9,6 0,17 0,40 47,0 71,5 630 30,6 18,0 70,1 95 4,0 85,0 6,9 10,8 0,19 0,37 59,2 90,1 800 34,7 18,0 74,2 95 4,0 89,0 7,7 12,7 0,21 0,36 75,2 114,4 14,6 1000 39,3 18,0 78,8 95 4,0 94,0 8,6 14,8 0,22 0,35 94,0 143,0 1200 43,5 18,0 83,0 95 4,0 98,0 9,5 17,2 0,24 0,34 112,8 171,6 1600 51,0 18,0 90,5 95 4,0 106,0 11,2 21,3 0,27 0,32 150,4 228,8 (1) Values calculated according to IEC 949 based on a conductor temperature of 90 C. (2) Values calculated according to IEC 949 based on a metallic screen temperature of 70 C before short-circuit. 11

uminium or Copper High Voltage Cables (cont.) Characteristics of installation of the Cables: - Ambient air temperature: 30 0 C - Laying depth: 1,2 m - Ground temperature: 20 0 C - Ground thermal resistivity: 1,2 0 K.m/W Characteristics of use of the Cables: - Permissible short circuit temperature: 250 0 C - Permissible operating temperature : 90 0 C - Permissible screen temperature: 70 0 C rrent Rating for XLPE Cable Systems (A) Trefoil formation Cross section conductor Cables in Ground Cables in Air Mise à la terre des l écrans Cross Bonded Cross Bonded Cross Bonded Both ends 2 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C 65 0 C 90 0 C Rated voltage 45-60 kv Rated voltage 64-150 kv 150 242 292 310 374 242 292 310 374 254 347 327 444 254 347 327 444 185 273 328 351 424 273 328 351 419 288 395 371 508 288 395 371 508 240 319 383 406 488 314 383 401 488 342 469 435 601 342 469 435 596 300 360 433 460 551 355 428 451 547 391 537 498 688 391 532 493 679 400 410 492 519 629 406 488 506 615 459 625 581 796 454 620 566 781 500 469 565 588 711 460 556 570 688 532 727 664 918 522 718 644 893 630 533 643 661 797 519 629 629 770 615 845 762 1055 601 830 732 1020 800 602 725 729 889 579 706 693 848 708 972 859 1191 688 952 820 1147 1000 665 807 793 971 638 779 743 916 801 1103 957 1328 771 1074 903 1269 300 355 424 451 547 346 419 433 529 395 537 503 684 391 527 493 669 400 406 488 510 620 392 478 488 592 459 620 581 791 449 610 561 767 500 460 556 579 702 442 538 542 661 532 723 664 908 513 703 635 869 630 524 633 647 788 497 606 597 734 610 835 762 1045 591 810 713 986 800 592 715 720 875 551 674 652 802 703 962 854 1182 664 918 791 1103 1000 656 797 779 957 602 743 697 861 791 1089 947 1313 742 1030 864 1211 1200 702 857 907 1107 638 788 747 925 859 1186 1128 1553 801 1113 967 1357 1600 779 957 1021 1253 697 866 807 1012 977 1352 1309 1807 898 1255 1084 1533 Rating Factors: Laying depth, m Rating factor Ground temperature, 0 C Conductor temperature, 0 C 10 15 20 25 30 35 40 45 0,50 1,12 0,70 1,07 0,90 1,07 1,00 1,02 1,20 1,00 1,50 0,97 90 1,07 1,04 1,00 0,96 0,93 0,89 0,84 0,8 65 1,11 1,05 1,00 0,94 0,88 0,82 0,74 0,66 Ambient air temperature, 0 C Air temperature, 0 C 10 15 20 25 30 35 40 45 Factor 1,18 1,13 1,10 1,05 1,00 0,95 0,90 0,85 12 d Ground thermal resistivity Thermal resistivity, 0 Km/W 0,7 1,0 1,2 1,5 2,0 2,5 3,0 Factor 1,23 1,08 1,00 0,9 0,8 0,72 0,66 Number of groups Distance d between groups, 1 2 3 4 5 6 7 8 100 1,00 0,76 0,67 0,59 0,55 0,51 0,49 0,47 200 1,00 0,81 0,71 0,65 0,61 0,49 0,56 0,53 400 1,00 0,85 0,77 0,72 0,69 0,66 0,64 0,63 600 1,00 0,88 0,81 0,77 0,74 0,72 0,71 0,7