POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

Similar documents
Beaver Power Factor Correction Capacitors

High Frequency SineWave Guardian TM

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 480 Volts, 60Hz. Page 1 of 14. April 15, 2010: updated capacitor UL File number)

CALTRAP INSTALLATION AND OPERATIONS MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

A. Submit manufacturer's literature and technical data before starting work.

C1000 Series Automatic Cap Bank

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Motor Protection. Presented By. Scott Peele PE

Quick Start Guide TS 910 & TS 920

Index Low Voltage Network Quality. Low Voltage Network Quality

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Individual & fixed bank capacitors

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Power factor correction Harmonic filtering Dynamic flicker compensation

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

MATRIX FILTER USER MANUAL. SERIES D 400 Volts, 50HZ PART NO. INSTR 025 REL REV MTE Corporation

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

Power System Solutions (PSS)

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Technical data OT16E3 OT160E3 UL & CSA

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

Technical Specification for Pole Mounted Capacitor Rack

North America Phase Converters & Electrical Supply

Quick Start Guide TS 910

University of Houston Master Construction Specifications Insert Project Name

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

POWER CAPACITORS. Cylindrical capacitor standard duty

Technical Specification For Outdoor Substation Harmonic Filter Banks

BUSWAY Low Voltage (Pow-R-Flex)

Metal-enclosed medium voltage power factor correction system

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

MODEL SCA Installation and Operation Manual Important:

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 480 Volts, 60HZ PART NO. INSTR 024 REL REV MTE Corporation

General information about motor protection

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

Ultravar TM AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS

X100P Load Bank. Read all instructions before using the load bank. Contents

LV Capacitor CLMD03 Power Module Instruction manual

Application guide. Tmax Link OEM UL 891 Switchboard Program

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

PT Series Phase Converters OPERATION & INSTALLATION MANUAL

Publication No.: PSG

Generator Fire Safety: Generator assemblies should be located outside the building.

Metal-enclosed medium-voltage power factor correction system

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

ALL PURPOSE CNC/HEAVY DUTY

Fused Coordination Panelboard

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

LV Capacitor CLMD Reliability for Power Factor Correction

SECTION PANELBOARDS

EMPAC Metal enclosed capacitor bank for wind applications

M T E C o r p o r a t i o n. MTE Series RL. Line/ load Reactors USER MANUAL PART NO. INSTR -011 REL MTE Corporation

Operations and Service Manual. X30208 Load Bank

PHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC

OTEC Transfer switch open transition

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Operations and Service Manual. XE400D-SB Load Bank

READ THIS BEFORE INSTALLING SWITCHGEAR

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

SUBSTATION EQUIPMENT - Page 1 of 8

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Film Capacitors Power Factor Correction

Table of Contents. 2 Installation and Start-up Instructions for AF-600 Bypass, NON Bypass & Disconnect Drive Panels - DEH40600

Customer Requirements Downtown Secondary Network Service

CP Automatic capacitor bank

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

PHASEPERFECT 240V. Digital Phase Converter. Operation & Installation Manual. Single-Phase to Three-Phase Solid State Technology 97% Efficient

PROCESS ELECTRONICS CORPORATION

SWITCHGEAR DIVISION PRODUCT PROFILES

Modifiable TITAN Horizontal Motors Accessories and Modifications

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Transcription:

User s Manual for The POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR 301 Gaddis Boulevard Dayton, Ohio 45403 U.S. Toll Free 866-261-1191 (937) 253-1191 Fax: (937) 253-1723 Web site: www.stacoenergy.com Form No.003-2206 Rev A 02/25/2009

CAUTION! THE FOLLOWING OPERATIONS MUST BE PERFORMED BEFORE ACCESSING THE INSIDE OF THE EQUIPMENT: 1. DISCONNECT THE POWER SUPPLY. 2. WAIT AT LEAST FIVE (5) MINUTES FOR DISCHARGING CAPACITORS. CONFIRM BY USE OF A VOLTMETER FOR BOTH AC AND DC. 3. THEN SHORT CIRCUIT AND EARTH ALL OF THE CAPACITORS. CONTENTS DESCRIPTION... 1 COMPONENTS... 4 Module Assembly (Enclosure)... 4 Capacitors... 4 Fuses/Blown Fuse Indication (Optional)... 4 INSTALLATION... 5 Ambient Temperatures (See Table 1)... 5 Location Ambient Temperature... 5 Operating Ambient Temperature... 5 Operation Voltage... 6 Connection to the Mains... 6 Power Connections: L1, L2, L3 and PE... 6 MAINTENANCE... 8 Maintenance Program... 8

SHORT CIRCUIT CURRENT VOLT MAXIMUM Power Factor Correction DESCRIPTION The is designed to be used in low voltage (240-600vac), 3-phase, 60 Hz networks; options include fuses and blown fuse indication. 3.00 [76.2].06 [1.5] 6.00 [152.4] Ø.28 [Ø7.1] MOUNTING HOLE TYP..38 [9.5] 12.25 [311.2] 13.25 [336.6] 14.00 [355.6] 13.25 [336.6] 12.50 [317.5] POWER FACTOR CORRECTION MODEL VAC PHASE HZ KVAR AMPS SYMMETRICAL, 528 10 KA RMS S/N: 6.00 [152.4] UL 22.50 [571.5] 6.00 [152.4] Disconnect power and wait minimum of 5 minutes before servicing. 5.38 [136.5].06 [1.5] Form No. 003-2206 Rev A 1

MODEL VAC KVAR Disconnect power and wait minimum of 5 minutes before servicing. PHASE AMPS SHORT CIRCUIT CURRENT 10 KA RMS SYMMETRICAL, 528 VOLT MAXIMUM S/N: HZ Power Factor Correction.06 [1.5] 3.00 [76.2] 6.00 [152.4] Ø.28 [Ø7.1] MOUNTING HOLE TYP. 18.25 [463.6] 19.25 [489.0] FUSE BLOWN INDICATING LAMPS BEHIND CLEAR COVER.38 [9.5] 20.00 [508.0] 19.25 [488.9] 12.81 [325.4] 12.50 [317.5] 6.00 [152.4] POWER FACTOR CORRECTION LOUVER VENTS U L 22.50 [571.5] 6.00 [152.4] 5.38 [136.5].06 [1.5] Form No. 003-2206 Rev A 2

Voltage KVAR Range Capacitors Enclosure Size 240 2-50 480 2-125 600 2.5-125 240 480 600 60-100 150-300 150-300 Dimensions (HxWxD, inches) 1-5 U 22.50 x 14.00 x 12.5 6-10 V 22.50 x 20.00 x 12.81 Form No. 003-2206 Rev A 3

COMPONENTS MODULE ASSEMBLY (ENCLOSURE) capacitors are housed in either a 14 or 16 gauge metal enclosure, painted ANSI 61 gray. All units include either a stud or terminal type power line connection and allow for quick, simple installation. CAPACITORS Capacitors are three phase, metallized polypropylene, or vegetable oil impregnation, which are self-healing to prevent permanent dielectric breakdown. Each capacitor is designed for long life and operation for a wide temperature range and is contained in a steel can. Pressure sensitive circuit interruption is incorporated within the capacitor to safely remove the unit from service under heavy fault conditions, while maintaining case integrity (10k available fault current rating with or without fuses). External discharge resistors allow voltage to be reduced to 50 volts or less in one minute. Resistors are sized for long life and continuous operation, at maximum rated temperature. FUSES/BLOWN FUSE INDICATION (OPTIONAL) Options include current limiting fuses rated for 100kaic, 200kaic, for over-current protection, and blown fuse indication lights (three fuses and three neon lights). Where over-current protection is required, applicable NEC codes should be followed for proper equipment installation. Form No. 003-2206 Rev A 4

INSTALLATION Correct installation is required for proper performance and function of the equipment. Physical inspection of equipment for damage is recommended, prior to any installation. Indoor storage for indoor and outdoor rated equipment should be in a clean, dry environment. A cautionary note, placement of the assembly shall be at a level and solid location, for correction operation. The unit can be either wall or floor mounted with cable entrance at top or side. Equipment should be placed in a well-ventilated environment and air must be able to circulate freely. National Electrical Code (NEC), electric utility company, local area or service provider codes shall be adhered to during the installation. Electrical connections shall also be in compliance with required codes. Installer/Contractor shall inspect and verify proper alignment, anchorage and grounding, proper connections and tightness of connections, prior to any start-up functions. Appropriate personnel shall start-up and operate equipment upon installation approval. AMBIENT TEMPERATURES (SEE TABLE 1) In every capacitor installation, there are two very important ambient temperatures: Location Ambient Temperature and Operating Ambient Temperature. Location Ambient Temperature is the temperature of the location before capacitors are installed or with the capacitors installed, but not operating (not energized). This is the temperature of the surrounding air in the room, vault, sub-station, or enclosure where capacitors will be operating. Operating Ambient Temperature is the temperature of the surrounding air during capacitor operation (capacitors energized). If there is a question as to the temperature at the location during operation, it is suggested that temperature measurements be taken in accordance with the following NEMA instructions: A. Units shall be in operation continuously for at least 24 hours before temperature is measured. B. The Operating Ambient Temperature shall be determined by taking the average of the readings of three thermometers placed as follows: One thermometer level with top of units. One thermometer 12 inches above bottom of units. One thermometer midway between the two above positions. Form No. 003-2206 Rev A 5

All three thermometers shall be placed 12 inches away (horizontally) from units. Maximum ambient temperatures are as follows: TABLE 1 Capacitor Installation Suggested Location Ambient Temperature 1 Maximum Operating Ambient Temperature 1 Single Unit 40 C (104 F) 46 C (115 F) Single Row of Units Multiple Rows Of Tiers 35 C (95 F) 40 C (104 F) 30 C (86 F) 35 C (95 F) Since excessive heating may be cause of capacitor failure, care must be used in selecting installation location. Forced air cooling may be required in certain locations. If the maximum operating ambient temperatures are exceeded, units must be disconnected from the a-c line. Telephone your sales representative at once for advice on corrective action which may be required. OPERATION VOLTAGE Check the capacitor nameplate to make certain that the capacitor voltage rating is suitable for operation at the supply (line) voltage. Capacitors are capable of operation at maximum of 110 percent of nameplate rated voltage. CONNECTION TO THE MAINS Power Connections: L1, L2, L3 and PE Connect L1, L2 and L3 terminals of either terminal block or fuse holder provided inside the enclosure to the network using 75 C minimum copper leads of the proper gauge. Connect an appropriate ground lead to the ground lug provided inside the enclosure. The National Electrical Code, Article 460, governs the installation of capacitors. Staco Energy Products Power Factor Correction Fixed Bank capacitors meet all of the requirements of the code relative to discharge resistors and over-current protection. 1 Temperatures with unrestricted ventilation Form No. 003-2206 Rev A 6

When applying capacitors to motor circuits, capacitors should usually be connected on the load side of the motor starter. In such installations, it may be desirable to change the overload protector size by the amount of the current reduction attendant with capacitor installed at Location 1. CAUTION When applying capacitors to motors which are subject to plugging, jogging, reversing, open transition compound starting (or on many multi-step or multi-speed motors), it is strongly recommended that the capacitor be connected between the motor starter and the disconnect at Location 3. This will result in the capacitor being energized even though the motor is not operating. The disconnect provides the appropriate means for the required removal capability per the Code (if it is not serving a branch circuit). CAPACITOR INSTALLATION - MOTOR CIRCUIT Motor Feed Fused Safety Switch or Breaker THREE LOCATIONS FOR CAPACITORS ON MOTOR CIRCUITS Thermal 3 2 Overload 1 Motor Starter Motor INSTALL AT LOCATION: Capacitor Capacitor 3 2 Figure 2 Capacitor 1 A. Install at Location 1 Motor side of thermal overload protectors when new motor installation is made and overloads can be sized in accordance with reduced current draw or on existing motors when change of thermal overload is not required. B. Install at Location 2 Between the starter and thermal overloads on existing motor applications when overload rating is higher than permitted by code [NEC 430-32(a)]. Form No. 003-2206 Rev A 7

C. Install at Location 3 On the line side of the starter, when separate disconnect means exist. This is a required location when motors are to be jogged, plugged or reversed, for multi-speed motors, for all starters having open transition and for starters that in any way disconnects the capacitor momentarily during the cycle and then reconnects the unit. MAINTENANCE MAINTENANCE PROGRAM Every Six (6) Months Examine outside of enclosure for damage, objects obstructing access and/or ventilation flow. Disconnect circuit breaker (or switch) from external feeder, or circuit breaker. Allow capacitors to discharge for at least five (5) minutes before performing maintenance. Visually inspect power factor correction capacitors and resistors. Broken or burned resistors need replacement. Check capacitors for any swelling. Visually inspect fuses to see if blown, replace as necessary, note operation of lights. Inspect all connections, tighten as required. Clean inside area of any dirt and debris. Maintenance should be performed on StacoVAR equipment, along with panel board, switchboard, switch gear, motor control centers and other electrical power distribution equipment for optimum and efficient operation. Spare parts required. Consult factor for caps, fuses, and lights. Form No. 003-2206 Rev A 8

Recommended Wire Sizes and Fuses for 3-Phase, 60 Hz Capacitors. 240 Current Ratings Wire 480vac Current Ratings Wire VAC Actual Fuse Size Kvar Actual Fuse Size kvar Amps Amps Amps Amps 2 4.81 10 14 2 2.41 5 14 2.5 6.01 10 14 5 6.01 10 14 4 9.62 15 14 7.5 9.02 15 14 5 12.03 20 14 10 12.03 20 14 7.5 18.04 30 12 12.5 15.04 25 14 10 24.06 40 10 15 18.04 30 12 12.5 30.07 50 8 20 24.06 40 10 15 36.09 63 8 25 30.07 50 8 20 48.11 80 6 30 36.09 63 8 25 60.14 100 4 35 42.10 80 6 30 72.17 125 3 40 48.11 80 6 40 96.23 160 1 45 54.13 100 4 50 120.28 200 2/0 50 60.14 100 4 60 144.34 250 3/0 60 72.17 125 3 75 180.43 315 250M 75 90.21 160 1 100 240.57 400 400M 80 96.23 160 1 100 120.28 200 2/0 600 Current Ratings Wire 125 150.36 250 3/0 VAC Actual Fuse Size 150 180.43 315 250M kvar Amps Amps 175 210.50 350 300M 2.5 2.41 5 14 200 240.57 400 400M 5 4.81 10 14 7.5 7.22 15 14 10 9.62 20 14 12.5 12.03 20 14 15 14.43 25 14 20 19.25 40 10 25 24.06 40 10 30 28.87 50 8 35 33.68 63 8 40 38.49 80 6 45 43.30 80 6 50 48.11 80 6 60 57.74 100 4 75 72.17 125 3 100 96.23 160 1 125 120.28 200 2/0 150 144.34 250 3/0 175 168.40 315 250M 200 192.46 350 300M Wire sizes based on NEC at 135% rated current using 90 C rated wire. Form No. 003-2206 Rev A 9