LV Capacitor Bank APC

Similar documents
LV Capacitor Bank APC

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

APC03 capacitor bank series The ABB comprehensive solution for automatic power factor correction

LV Capacitor CLMD Reliability for Power Factor Correction

DYNACOMP. The top-class reactive power compensator

CLMD Low-voltage capacitors for reliable power factor correction

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

Dynacomp The Top-Class Dynamic Response Compensator

LV Capacitor CLMD03 Power Module Instruction manual

MODVAR Low voltage reactive power compensation modules Installation manual

PhiCap Capacitors for Power Factor Correction

System pro E power Capacitor Bank

Power Factor Correction Capacitors Type LKT

Power Factor Correction Capacitors in sheet steel cases

Power Factor Correction Equipment

High Reliable Components for Power Factor Correction and Power Quality

&MFDUSJGJDBUJPO Products 1PXFS 2VBMJUZ 'JMUFST 12'* o 12'. o 12'4 )BSNPOJDT NJUJHBUJPO MPBE CBMBODJOH BOE SFBDUJWF DPNQFOTBUJPO PO -7 OFUXPSLT

CLASS 5870 ReactiVar Power Factor Capacitors AT6000/AT7000 Transient Free Reactive Compensation

Low Voltage Products. Low Voltage Capacitors Power Factor Correction Solutions

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Power factor correction Harmonic filtering Dynamic flicker compensation

Sharda Electronics & Co. An ISO 9001:2015 Certified Company

LV Capacitors QCap-L series Capacitors for power factor correction

ARTECHE LOW VOLTAGE CAPACITOR BANKS. smartbat LV.

Three Phase Capacitors KNK

Automatic COSYS PFC. Automatic power factor correction system NEW

Power Factor Correction - UPS - Stabilizers - AC / DC Power Supply Units

EMPAC Metal enclosed capacitor bank for wind applications

Film Capacitors Power Factor Correction

Film Capacitors Power Factor Correction

High Reliable Components for Power Factor Correction and Power Quality

CP Automatic capacitor bank

Index Low Voltage Network Quality. Low Voltage Network Quality

Power System Solutions (PSS)

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

C1000 Series Automatic Cap Bank

FINHRM FINHRM5 FINHRMA FINHRMAC

Compact Energy Storage Module. Modular Systems, EPDS. Product overview

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Power Factor Correction

POWER CAPACITORS. Cylindrical capacitor standard duty

AC Capacitors Safety and Application Manual

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

PRODUCT CATALOGUE 2016

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

Automatic capacitor banks

ahead of time Voltage Stabilisers

AIR CORE REACTORS. Phoenix Electric Corporation

Easy Choice for Energy Efficiency

multicond Power capacitors Data sheet: multicond

HV Compensation & Filtering Products

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

TECHNICAL SPECIFICATIONS for LOW VOLTAGE CAPACITOR BANKS 140 Kvar

PQstorI One stop solution for energy storage and power quality

Power Factor Correction Capacitors Type LKT

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6

Smart Energy & Power Quality Solutions. Main catalogue 2012/2013. Power Factor Correction / Power quality

AGroup brand POWER FACTOR CORRECTION AND CONTROL OF ELECTRICAL NETWORK QUALITY INTERNATIONAL VERSION

Distribution transformers Efficiency over life-cycle

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Power Factor Correction Capacitors Type LKT

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

ABB n.v Power Quality in LV installations

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Power Factor Correction

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

Power Factor Correction Capacitors Harmonic Filter Reactors

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

MGE TM Galaxy TM 7000 GFC

VarSet Brochure and Catalog

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Industrial PFC UPS System

PQdynaC High speed, flexibility and modularity

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

Individual & fixed bank capacitors

Q pole Pole Mounted Capacitor System

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

FRANKE. Power Factor Correction GMKP ENERGY. GMKPg Low Voltage Capacitors by Gas Technology Save energy and reduce carbon dioxide emission!

Reactive Energy Management

B. Coefficient table for calculation of capacitance after rated voltage increase

YEK Energy Railway Systems Engineering

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

CTU 02. Thyristor switching module for fast PF compensation. User manual

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

ORION PLUS three-phase kVA

MADE IN GERMANY. Components for reactive power compensation. Components for reactive power compensation. Power Quality. Reactive power controllers

INSTRUCTION MANUAL (M A)

HARMONIC FILTER REACTOR

Power IT LV Active Filters PQFI - PQFM PQFK - PQFS

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Transcription:

LV Capacitor Bank APC The ABB comprehensive solution for automatic power factor correction: APC standard, reinforced and de-tuned automatic capacitor banks

The ABB comprehensive solution for automatic power factor correction The APC is a powerful and compact automatic bank. It is very easy to install and to operate. It provides a high level of reliability and security. APCL and APCM: standard and reinforced ranges APCL2 box of 125kvar (master unit) Fan RVC Controller Contactors HRC Fuses Power terminals Ample space for wiring CLMD33S capacitors Slave unit Bottom cable entry Master unit APCM2 cubicle of 400kvar (master unit) Lifting lugs Fans Contactors HRC Fuses Busbar RVC Controller CLMD33S capacitors modules Bottom cable entry Slave unit Plinth Master unit 2 ABB

APCR: de-tuned range - with reactors APCR cubicle of 300kvar (master unit) Lifting lugs Fans Contactors RVC Controller HRC Fuses Busbar CLMD33S capacitors modules Reactors modules Bottom cable entry Plinth Slave unit Master unit Powerful and compact ABB capacitors and a specially designed ventilation system allow the APC to reach a maximum reactive power within a minimum volume. Easy to select The APC exists in 4 versions: 1 type of box (APCL2) and 3 types of cubicles (APCM1, APCM2 and APCR). The APC offers a power range from 25 to 800kvar (in different configurations). Slave units are available for extension up to 250kvar in APCL2, 800kvar in APCM2 and 600kvar in APCR (1 master unit + 1 slave unit). Easy to install The APC is a complete unit, factory tested and ready for connection. Its commissioning may be completely automatic. There is ample space for wiring. The APCL2 box is equipped with wall mounting brackets. The APCM and APCR cubicles are equipped with a plinth and lifting lugs for easy handling. Slave units (APCL2, APCM2 & APCR) are equipped with an interconnection cable for fast connection to the master unit. Easy to use The multiple automatic functions of the RVC and its user-friendly interface make the APC very easy to operate. ABB 3

Reliable and safe The reliability of the APC is based on a set of ABB components specially designed for the reactive power compensation application. The APC has an IP23D protection level (closed door) and is protected against direct and accidental contact (open door). ABB capacitors The dielectric of the capacitors windings is made of in-house metallized polypropylene film giving exceptional properties: high voltage withstand capability. excellent peak current handling capacity. high capacitance stability. long life even under high electrical stress. very low losses. exceptional self-healing properties. CLMD33S construction The CLMD33S capacitor consists of a number of wound elements made with a dielectric of metallized polypropylene film. These dry windings are provided with a sequential disconnector ensuring that each element can be reliably and selectively disconnected from the circuit at the end of its life. The capacitor elements receive a treatment under vacuum in order to ensure perfect electrical characteristics. Each winding is placed in a plastic case and encapsulated in thermo-setting resine in order to obtain a perfectly sealed element. The elements are placed inside a sheet steel box and connected in such a way as to supply the three-phase power at the required voltage and frequency. The sheet steel box is filled with inorganic, inert and fire proof granules in order to absorb the energy produced or to extinguish any flames in case of a possible defect at the end of an element s life. Wire connection Metal end spray Power cables Discharge resistors In-house metallised polypropylene film (unique profile) Secondary foil winding Biaxially oriented polypropylene dielectric Thermo-setting encapsulation Plastic case Fuse link Metal enclosure Self-healing dry dielectric Very low losses Inert and non-toxic granules Holes for fixation ABB Contactors Contactors have been specially selected for their excellent endurance tests handling capability. 4 ABB

RVC PF Controller The RVC is not affected by the harmonics. The RVC complies with EU directives for EMC for operation at 50Hz and bears the CE marking to this effect. The RVC is suitable for hot environments thanks to its maximum ambient temperature of 60 C. The RVC is fitted with an overvoltage / undervoltage protection and protections against harmonic distortion (THDV). RVC LCD display with indication of: inductive/capacitive PF active outputs demand for switching on/off a capacitor step alarm conditions overtemperature condition capacitor disconnection key parameters : voltage, current, power factor, THDV and THDI Keypad Automatic setting of: phase shift C/k switching delay number of outputs type of switching sequence Easy commissioning with automatic recognition of: special connections (single-phase, CT leads) number of outputs type of switching sequence Automatic/manual mode ABB Reactors (for APCR execution) The dry type resin embedded reactors are specially designed to suit the reactive power compensation application. Their exceptional linearity and thermal stress resistance characteristics ensure a high reliability degree even in case of temporary overvoltage. Ventilation All APCs are equipped with a ventilation system specially selected for its long life duration. In case of temporary overheating, the APC is automatically disconnected. Environment friendly The ISO 14001 certification guarantees our commitment to the environment. ABB 5

Options Main circuit-breaker. Top cable entry (for APCM1, APCM2 and APCR only). RVT controller (for APCM1, APCM2 and APCR only). RVT Modbus For a maximum protection of your capacitor bank against temporary deterioration of your network quality. While having all the functions of the RVC, the RVT also has features including: programmable protection thresholds (undervoltage, overtemperature, excessive harmonic distortion, etc ). The RVT protects your capacitor bank. It is recommended for installation where overvoltage, resonance or overtemperature is likely to happen. full graphics display with backlighting. guided navigation and programming. network information and bank monitoring (voltage, current, harmonics spectrum, etc...) RS-485 Modbus adapter allowing communication with a monitoring system. All RVT parameters are remotely accessible (including harmonic spectra and tables.) multi-language support. help button giving instant access to a description of all RVT features and functionality. printer connection. input contacts for day/night cos ϕ and external alarm. output contacts for alarm and fan relays. (for further information on the RVT controller, please refer to our specific documentation) Wiring diagram T1 CT LOADS C1...C12 capacitor steps F1 F1 main fuses or protective devices F2 control fuses F3...F14 K1...K12 P1 T1 S capacitor step fuses contactors PF controller power transformer Fan DC supply P1 F2 F3-F14 R1-R12 * CT current transformer V1 fan * R1...R12 reactors (APCR only) S K1-K12 V1 C1-C12 6 ABB

Technical specifications Nominal voltage and frequency: 230, 400V - 50Hz (standard range). 240, 480V - 60Hz (standard range). 400V - 50Hz (reinforced range rated at 457V). 400, 415, 525, 690V - 50Hz (de-tuned capacitor bank) 240, 380, 480, 600V - 60Hz (de-tuned capacitor bank) Connection: Three phase. Configuration: APCM1: master unit only. APCL2, APCM2 & APCR: master and slave units. Slave units are not equipped with PF controller but are fitted with an interconnection cable. Power factor setting: From 0.7 inductive to 0.7 capacitive. Starting current setting (C/k): From 0.01A to 3A for the RVC controller. From 0.01A to 5A for the RVT controller (optional for the APCM1, APCM2 and APCR). Operation: Automatic or manual setting of the controller with indication of : - the number of active outputs. - the inductive or capacitive power factor. - alarm conditions. - overtemperature. - demand for switching on/off a capacitor step. - voltage, current, THDV and THDI Threshold setting for protection against overvoltage, undervoltage and high THDV. Losses: Dielectric losses: less than 0.2 Watt/kvar. Capacitor total losses: less than 0.5 Watt/kvar (discharge resistors included). Automatic bank total losses at 400V 50Hz: - without reactors: less than 1.5 Watt/kvar (including accessories losses), - with reactors: less than 5.5 Watt/kvar (including accessories losses). Capacitors: Dry type self healing according to IEC 60831-1&2. Voltage test: 2.15 Un between terminals during 10 sec at rated frequency (above IEC 60831-1&2). Acceptable overloads: - overvoltage tolerance: 10% max. intermittently. - overcurrent tolerance: 30% permanently. Temperature range: -25 C / class D according to IEC 60831-1&2. Reactors (APCR only): - Type : dry type resin embedded according to IEC 289, IEC 76 - Maximal harmonic voltage distortion: U 3 /U 1 = 0.5 % U 5 /U 1 = 6.0 % U 7 /U 1 = 5.0 % U 11 /U 1 = 3.5 % U 13 /U 1 = 3.0 % (not exceeding a THDU of 8 %). The automatic capacitor bank complies with EN 61921. Automatic capacitor bank tests: - Insulation test. - Functional test. CE Marked. Protection: IP23D (closed door). Protected against direct and accidental contact (open door). Execution: Indoor. Color: Beige RAL 7032. Ambient temperature: -5 C/+40 C according to EN 61921. Ventilation: - Forced Installation: Box: - Wall mounting (fixation brackets included). - Bottom cable entry. Cubicle: - Floor fixation. - Equipped with a plinth. - Lifting lugs provided. - Top or bottom cable entry. Slave units have to be connected to the master unit. Important notice: The installation of capacitors on networks disturbed by harmonics may require special precautions especially when there is a risk of resonance. ABB 7

APCL2, APCM1 and APCM2 Range Standard range 230V 50Hz - Clean network Type Power Regulation Optional main (kvar) at 230V x*kvar circuit-breaker APCL2 25 4*6.25 T1N160FFC 37.5 3*12.5 T1N160FFC 50.0 4*12.5 T3N250FF 62.5 5*12.5 T4N320FF (1) 100 8*12.5 2x T3N250FF (2) (1) 125 10*12.5 2x T4N320FF (2) APCM1 75 9*8.3 T4N320FF 87.5 7*12.5 T5N630FF 100 12*8.3 T5N630FF APCM2 112.5 9*12.5 T5N630FF 125 5*25 T5N630FF 150 6*25 T5N630FF 175 7*25 S6N800F 3P F 200 8*25 S6N800F 3P F (1) 250 10*25 2x T5N630FF (2) (1) 300 12*25 2x T5N630FF (2) (1) 400 16*25 2x S6N800F 3P F (2) Standard range 400V 50Hz - Clean network Type Power Regulation Optional main (kvar) at 400V x*kvar circuit-breaker APCL2 25 2*12.5 T1N160FFC 37.5 3*12.5 T1N160FFC 50 4*12.5 T1N160FFC 62.5 5*12.5 T1N160FFC 75 3*25 T3N250FF 87.5 7*12.5 T3N250FF 100 4*25 T3N250FF 125 5*25 T4N320FF (1) 200 8*25 2x T3N250FF (2) (1) 250 10*25 2x T4N320FF (2) APCM1 150 9*16.7 T5N630FF 175 7*25 T5N630FF 200 4*50 T5N630FF 200 12*16.7 T5N630FF APCM2 225 9*25 T5N630FF 250 5*50 T5N630FF 275 11*25 S6N630FF 300 6*50 S6N800F 3P F 325 13*25 S6N800F 3P F 350 7*50 S6N800F 3P F 400 8*50 S7S1250F 3P F (1) 450 18*25 2x T5N630FF (2) (1) 500 10*50 2x T5N630FF (2) (1) 600 12*50 2x S6N800F 3P F (2) (1) 700 14*50 2x S6N800F 3P F (2) (1) 800 16*50 2x S7S1250F 3P F (2) (1): 1 master unit + 1 slave unit. (2): Circuit breaker for master unit and circuit breaker for slave unit. Reinforced range (capacitor rated at 457V) 400V 50Hz - Slightly polluted network Type Power Regulation Optional main (kvar) at 400V x*kvar circuit-breaker APCL2 25 2*12.5 T1N160FFC 37.5 3*12.5 T1N160FFC 50 4*12.5 T1N160FFC 62.5 5*12.5 T1N160FFC 75 3*25 T3N250FF 87.5 7*12.5 T3N250FF 100 4*25 T3N250FF APCM1 112.5 9*12.5 T4N320FF 131 7*18.7 T4N320FF 150 12*12.5 T5N630FF APCM2 168 9*18.7 T5N630FF 187.5 5*37.5 T5N630FF 225 6*37.5 T5N630FF 262.5 7*37.5 T5N630FF 300 8*37.5 S6N800F 3P F Standard range 240V 60Hz - Clean network Type Power Regulation Optional main (kvar) at 240V x*kvar circuit-breaker APCM1 75 9*8.3 T4N320FF 87.5 7*12.5 T5N400FF 100 12*8.3 T5N400FF APCM2 112.5 9*12.5 T5N500FF 125 15*8.3 T5N630FF 150 6*25 T5N630FF 175 7*25 S6N800F 3P F 200 8*25 S6N800F 3P F (1) 250 30*8.3 2x T5N630FF (2) (1) 300 12*25 2x T5N630FF (2) (1) 400 16*25 2x S6N800F 3P F (2) Standard range 480V 60Hz - Clean network Type Power Regulation Optional main (kvar) at 480V x*kvar circuit-breaker APCM1 90 6*15 T3N200FF 112.5 5*22.5 T3N250FF 135 9*15 T4N320FF 157.5 7*22.5 T4N320FF 180 12*15 T5N400FF APCM2 202.5 9*22.5 T5N400FF 225 11*22.5 T5N630FF 247.5 5*50 T5N630FF 270 6*45 T5N630FF 292.5 13*22.5 T5N630FF 315 7*45 S6N800F 3P F 360 8*45 S6N800F 3P F (1) 450 10*45 2x T5N500FF (2) (1) 540 12*45 2x T5N630FF (2) (1) 630 14*45 2x S6N800F 3P F (2) (1) 720 16*45 2x S6N800F 3P F (2) Slave units are available for extension. Only master and slave units of the same type can work together (APCL2 master with APCL2 slave, APCM2 master with APCM2 slave and APCR master with APCR slave). For compatibility between master unit and slave unit, please check with your local ABB agent that the total (master + slave) switching sequence (1:1:2:2:..., 1:2:4:4:..., etc) is recognized by the PF controller. 8 ABB

APCR Range 400V 50Hz - Polluted network (kvar) at 400V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T3N250FF 125 5*25 T4N320FF 150 3*50 T5N630FF 150 6*25 T5N630FF 175 7*25 T5N630FF 200 4*50 T5N630FF 200 8*25 T5N630FF 250 5*50 T5N630FF 300 6*50 S6N800F 3P F (1) 350 7*50 2x T5N630FF (2) (1) 400 8*50 2x T5N630FF (2) (1) 450 9*50 2x T5N630FF (2) (1) 500 10*50 2x T5N630FF (2) (1) 600 12*50 2x S6N800F 3P F (2) 415V 50Hz - Polluted network (kvar) at 415V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T3N250FF 125 5*25 T4N320FF 150 3*50 T5N630FF 150 6*25 T5N630FF 175 7*25 T5N630FF 200 4*50 T5N630FF 200 8*25 T5N630FF 250 5*50 T5N630FF 300 6*50 S6N800F 3P F (1) 350 7*50 2x T5N630FF (2) (1) 400 8*50 2x T5N630FF (2) (1) 450 9*50 2x T5N630FF (2) (1) 500 10*50 2x T5N630FF (2) (1) 600 12*50 2x S6N800F 3P F (2) (1): 1 master unit + 1 slave unit. (2): Circuit breaker for master unit and circuit breaker for slave unit. (3): Circuit breaker for master unit. (4): Circuit breaker for slave unit. 525V 50Hz - Polluted network (kvar) at 525V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T3N250FF 5.67-7 - 12.5 125 5*25 T3N250FF 5.67-7 150 3*50 T4N320FF 5.67-7 - 12.5 150 6*25 T4N320FF 5.67-7 175 7*25 T4N320FF 5.67-7 200 4*50 T5N630FF 5.67-7 200 8*25 T5N630FF 12.5 (1) 200 8*25 2x T3N250FF (2) 5.67-7 250 5*50 T5N630FF 12.5 (1) 250 10*25 2x T3N250FF (2) 5.67-7 300 6*50 T5N630FF 12.5 (1) 300 12*25 2x T4N320FF (2) 5.67-7 (1) 350 7*50 T5N630FF (3) T4N320FF (4) 5.67-7 (1) 400 8*50 2x T5N630FF (2) 5.67-7 (1) 450 9*50 2x T5N630FF (2) 5.67-7 (1) 500 10*50 2x T5N630FF (2) 5.67-7 (1) 600 12*50 2x T5N630FF (2) 690V 50Hz - Polluted network (kvar) at 690V x*kvar circuit-breaker 5.67-7 - 12.5 100 4*25 T1N160FFC 125 5*25 T3N250FF 150 3*50 T3N250FF 150 6*25 T3N250FF 175 7*25 T3N250FF 200 4*50 T4N320FF 200 8*25 T4N320FF 250 5*50 T5N630FF 300 6*50 T5N630FF (1) 350 7*50 T4N320FF (3) T3N250FF (4) (1) 400 8*50 2x T4N320FF (2) (1) 450 9*50 T5N630FF (3) T4N320FF (4) (1) 500 10*50 2x T5N630FF (2) (1) 600 12*50 2x T5N630FF (2) Slave units are available for extension. Only master and slave units of the same type can work together (APCL2 master with APCL2 slave, APCM2 master with APCM2 slave and APCR master with APCR slave). For compatibility between master unit and slave unit, please check with your local ABB agent that the total (master + slave) switching sequence (1:1:2:2:..., 1:2:4:4:..., etc) is recognized by the PF controller. ABB 9

APCR Range 240V 60Hz - Polluted network (kvar) at 240V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T5N630FF 125 5*25 T5N630FF 150 6*25 T5N630FF (1) 200 8*25 2x T5N630FF (2) (1) 250 10*25 2x T5N630FF (2) (1) 300 12*25 2x T5N630FF (2) 380V 60Hz - Polluted network (kvar) at 380V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T4N320FF 125 5*25 T4N320FF 150 3*50 T5N630FF 150 6*25 T5N630FF 175 7*25 T5N630FF 200 4*50 T5N630FF 200 8*25 T5N630FF 250 5*50 S6N800F 3P F 300 6*50 S6N800F 3P F (1) 350 7*50 2x T5N630FF (2) (1) 400 8*50 2x T5N630FF (2) (1) 450 9*50 S6N800F 3P F (3) T5N630FF (4) (1) 500 10*50 2x S6N800F 3P F (2) (1) 600 12*50 2x S6N800F 3P F (2) (1): 1 master unit + 1 slave unit. (2): Circuit breaker for master unit and circuit breaker for slave unit. (3): Circuit breaker for master unit. (4): Circuit breaker for slave unit. 480V 60Hz - Polluted network (kvar) at 480V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T3N250FF 125 5*25 T3N250FF 150 3*50 T4N320FF 150 6*25 T4N320FF 175 7*25 T5N630FF 200 4*50 T5N630FF 200 8*25 T5N630FF 250 5*50 T5N630FF 300 6*50 T5N630FF (1) 350 7*50 T5N630FF (3) T4N320FF (4) (1) 400 8*50 2x T5N630FF (2) (1) 450 9*50 2x T5N630FF (2) (1) 500 10*50 2x T5N630FF (2) (1) 600 12*50 2x T5N630FF (2) 600V 60Hz - Polluted network (kvar) at 600V x*kvar circuit-breaker 6-7 - 12.5 100 4*25 T1N160FFC 125 5*25 T3N250FF 150 3*50 T3N250FF 150 6*25 T3N250FF 175 7*25 T4N320FF 200 4*50 T4N320FF 200 8*25 T4N320FF 250 5*50 T5N630FF 300 6*50 T5N630FF (1) 350 7*50 T4N320FF (3) T3N250FF (4) (1) 400 8*50 2x T5N630FF (2) (1) 450 9*50 T5N630FF (3) T4N320FF (4) (1) 500 10*50 2x T5N630FF (2) (1) 600 12*50 2x T5N630FF (2) Slave units are available for extension. Only master and slave units of the same type can work together (APCL2 master with APCL2 slave, APCM2 master with APCM2 slave and APCR master with APCR slave). For compatibility between master unit and slave unit, please check with your local ABB agent that the total (master + slave) switching sequence (1:1:2:2:..., 1:2:4:4:..., etc) is recognized by the PF controller. 10 ABB

Dimensions Overall dimensions H (mm) W (mm) D (mm) Maximum weight APCL2 750 550 275 42 kg APCM1 1350 600 400 100 kg APCM2 1950 600 400 175 kg APCR 2000 600 550 500 kg 600 400 550 275 ( * ) 100 APCL2 APCM1 600 400 600 550 100 100 1950 1900 2000 1950 750 1350 1300 100 APCM2 100 APCR * thickness of the air grid (25 mm) not included ABB 11

Capacitor bank selection The installation of capacitors on network disturbed by harmonics may require special precautions especially when there is a risk of resonance. Feel free to consult your local ABB agent for a proper selection of your APC LV Capacitor Bank. Network Study Our Power Quality specialists will, on request, perform a harmonic study of your network in order to propose you a reactive power compensation solution that prevents any risk of resonance, for maximum reliability. www.abb.com/lowvoltage While all care has been taken to ensure that the information contained in this publication is correct, no responsibility can be accepted for any inaccuracy. We reserve the right to alter or modify the information contained herein at any time in the light of technical or other developments. Technical specifications are valid under normal operating conditions only. We do not accept any responsibility for any misuse of the product and cannot be held liable for indirect or consequential damages. 2GCS301016A0040