GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Installation Guide

Similar documents
GE Industrial Solutions. Limitamp * AR. Arc Resistant Medium Voltage Motor Control. Application Guide

Section 18. Medium Voltage Equipment. BuyLog Catalog 18-1

CR193 Vacuum Limitamp* Contactors

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

USER MANUAL Bulletin 1512A 400A One-High Cabinet Standard and Arc-Resistant Enclosure

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Bulletin 1494C Cable Operated Disconnect Switch Kit (600A) Installation Instructions (Cat 1494C- _ Series 2 : 600A)

Bulletin 1494C Cable Operated Disconnect Switch Kit (400A) Installation Instructions (Cat 1494C- _ Series 2 : 400A)

CR193 B,C,D and E Vacuum Limitamp * Contactors

Instruction and Installation Guide

Bulletin 1494V Variable Depth Disconnect Switch Installation Instructions (Cat 1494V-DS400; -DSX400 - Series D)

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Isolation Switch (behind barrier & inspection window) Power Fuses. Load Cable Connection Box. Contactor. Control Power Transformer Secondary Fuse

MODELS DSH/KSH/DSV/KSV R-410A LOW-AMBIENT KIT

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

Design Standard. Purpose: Design Standard:

SIGNAL WORDS QUALIFIED PERSON

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Type 2 Arc Resistant WL Low Voltage Metal-Enclosed Switchgear

Table of Contents. Quick Installation Guide 2 - Disconnect Switch Installation - Disconnect Handle Installation - Cutting Connecting Rod

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Instructions for AMPGARD 400A medium voltage starter

Medium Voltage Equipment. Section 15.

Class E2 Medium-Voltage Controllers with Drawout Vacuum Contactors

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

INSTALLATION INSTRUCTIONS

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Instructions for Replacing

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Florham Park, NJ USA Call (ASCO) for sales or service

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

PowerFlex 7000 AC Drive with Direct-to-Drive Technology. Re-installing a Common Mode Choke Bulletin 7000 Installation Instructions

CCP2-FLR1-21_ flange-rod operating mechanism

Ampgard The name motor applications rely on

Evolution * Series E9000 Motor Control Center

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

Cutler-Hammer INSTRUCTIONS FOR MAGNUM DS METAL-ENCLOSED LOW-VOLTAGE SWITCHGEAR ASSEMBLIES WITH MAGNUM DS BREAKERS IB E

Medium voltage switchgear SafeGear HD 63 ka arc resistant metal-clad switchgear. ABB Group February 25, 2015 Slide 1

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Evolution Series E9000 *

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

COOKSON OWNER S MANUAL

Surepowr Series 100 Installation Manual

650 Series Cargo Van Lift Mounting Instructions Ford Transit (Standard Roof) 2015-Present

GE 8000-Line Motor Control Centers

INSTALLATION INSTRUCTIONS

Cutler-Hammer. Instructions for Potential Transformer and Auxiliary Control Power Disconnecting Means for Use in Ampgard Lineups, 7.2 kv I.B.

Bulletin 1494V Variable Depth, Flange Operated Circuit Breaker Kits for 125A, 150A 250A and 400A Frame Sizes

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Power Break Circuit Breakers

Instruction Bulletin. Jockey Pump Controller

Single Socket and Horizontal Metering

Florham Park, NJ USA Call (ASCO) for sales or service

2-row and All-row systems included.

READ THIS BEFORE INSTALLING SWITCHGEAR

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

650 Series Cargo Van Lift Mounting Instructions Fullsize Ford 1992-Present

Altivar 58 TRX Adjustable Speed Drive Controllers in Motor Control Centers hp, 480 V or 1 50 hp, 208/240 V Class 8998

Instructions for installation, operation, and maintenance of 38 kv type VacClad-W arc resistant metal-clad switchgear

80 Series 4 Post Brake Instructions

SEQUESTR. External Disconnect Enclosure. Rev. C 2013 Pentair Equipment Protection PH hoffmanonline.com P/N

xtablet T7000 Vehicle Mount Kit

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

E.S.P. Embedded Sensing Probes for Motor Brushes

Installation Instructions For Motor Control Center (MCC) Units

- Wiring Brochure tekmarnet 4 Thermostat 545

S&C Switch Operators Types AS-1A and AS-10

Service Manual. Vegetable Preparation Machine RG-250. Date: Approved: Henrik Artursson

A. Submit manufacturer's literature and technical data before starting work.

INSTRUCTIONS TOSHIBA. JK Medium Voltage Controllers Maximum OPERATION MAINTENANCE

Power Break II Switchboard

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

EXTREME R MOTOR OWNER'S MANUAL

Installation Instructions Electric Heaters 5 20 kw

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

- Wiring Brochure Universal Reset Module 422e

- Wiring Brochure Universal Reset Module 422

www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

TOYOTA SIENNA TRAILER WIRE HARNESS Preparation

Installation Instructions

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

RENEWAL PARTS I C302AA A-2 300V AB A-4800V A C A -SOOOV PARTS RECOMMENDED FOR NORMAL STOCK

SEQUESTR. External Disconnect Enclosure. Rev. A 2014 Pentair Equipment Protection PH hoffmanonline.com P/N

SIEMENS. Series 8100oT Vacuum Controllers. www. ElectricalPartManuals. com. Bulletin CC

5. Contractor Information 3M Model 2300 Series System Layout Checklist

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches 150 through 4000 amp. Rating Label. Nameplate A

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

WATER COOLED AIR CONDITIONING UNITS MODEL CVWSEK-060 WATER SIDE ECONOMIZER FOR CSV060B VERTICAL R-410A STYLE B R-410A

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

MODELS SGX AND SSX SINGLE DUCT ROUND AIR TERMINALS

Transcription:

GE Industrial Solutions Limitamp AR Arc Resistant Medium Voltage Motor ontrol Installation Guide

Table of ontents Introduction...3 Opening Medium Voltage oor...3 Medium Voltage oor Latches... Isolation Switch Handle to ontactor Mechanical Interlock...5 Medium Voltage oor efeater Latch... Low Voltage Box Wiring etails...7 Plenum Installation Guide...7 Turned Extension Plenum Installation Guide (Front/Rear)... 10 Turned Extension Plenum Installation Guide (Top/Bottom)... 11 Limitamp AR Extension Plenum... 13 Extension Plenum - General Guidelines... 1 able Entry From Top or Bottom... imensions... Arc Resistant Medium Voltage Motor ontrol 2

Introduction GE s Limitamp AR controllers are the solution for medium voltage control when that extra margin of safety is essential. They comply to the IEEE/ANSI 37.20.7-2007 Type 2B safety standard and are designed to provide personnel protection in the event of an arc flash occurrence. This means that when the medium voltage doors are properly secured, the service technician can still access the interior of the low voltage compartment. This installation guide is to be used in conjunction with GEH-23 (Two high vacuum equipment), GEH-530 (vacuum contactor) and GEH 539B (800A) instructions. Product Offering 1-high and 2-high 00A FVNR (full voltage non-reversing starters) 1-high 800A FVNR (full voltage non-reversing starters) 1-high 800A FVR (full voltage reversing starters) 1-high 00A FVR (full voltage reversing starters) RVAT (reduced voltage autotransformer starters) RVPR (reduced voltage primary reactor starters) 2S1W (two speed, single winding starters) 2S2W (two speed, dual winding starters) 00A MVSS (medium voltage solid-state starters) I-107 load break switches SYN excitation starters Main, Feeder and Tie sections Incoming line cable sections Auxiliary sections Figure 1. 3 wide Two-High AR FVNR starter with low-voltage doors open. WARNING: Before any adjustments, servicing, parts replacement or any other act is performed requiring physical contact with the electrical working components or wiring of this equipment, all power must be removed and locked off from all sources and all attached rotating equipment must have come to a complete stop. User personnel must be completely familiar with the following operating and maintenance instructions before attempting to service this equipment. WARNING: The vacuum interrupter integrity test should be performed before the high voltage vacuum contactors are energized for the first time and each time the contactors are returned to service after maintenance, adjustment or repair. Failure to perform this test may result in serious injury or death. AUTION: Product is not intended for nuclear use. Opening Medium Voltage oor The medium voltage doors on the R19 Two-High Vacuum Limitamp AR are mechanically interlocked to prevent the opening of the doors when equipment is energized. For safe opening of medium voltage door, follow the step-by-step procedure as mentioned below. Step 1: Press the silver latch release and rotate the black handle with a rapid positive motion to the full OFF position. The silver latch release must pop out and return to original position. See Figure 3. Step 2: Rotate the medium voltage door latch handle (silver color) 90 in the counter-clockwise direction to disengage the multi latches on the inside of the door. See Figure. Step 3: The medium voltage door may then be opened by pulling out on the latch handle. Latch Handle Figure 2. 3 wide Two-High AR FVNR starter with medium voltage doors open. Figure 3. Push in the handle latch Figure. Rotating the medium voltage door latch handle. Arc Resistant Medium Voltage Motor ontrol WARNING: onfirm that equipment is de-energized before opening the medium voltage doors. 3

Medium Voltage oor Latches The Limitamp AR design uses a special high strength door latching mechanism. All latches must be properly engaged for the product to function correctly. Rotating the silver door latch handle in a clockwise or counter-clockwise direction operates all of the locking pins. The door latch locking pins are adjusted prior to shipment from the factory. If latch pins are moved or replaced, ensure they are adjusted per the sketch below. Apply thread locker to the locking stud and re-tighten. When the door handle is in the locked position, adjust the locking pin bridge to provide a 0.150 gap between the bridge and the welded U fork on the door. The moving locking pins engage the fixed position latch plates. The mating part of the latch system is shown in Figure 7. The latch plates are bolted to the enclosure using a stud plate that passes through the flange of the case. The latch plates can be adjusted in all directions using the slots in the enclosure flanges and special shims. The latch parts should be adjusted so the moving locking pins engage the open slot latch plate. The nominal position for the latch plate is flush with the front edge of the enclosure flange. Latch Plates Should Be Flush With Front Flange of Enclosure Locking Stud.150 Figure 5. View to show gap between locking pin bridge and U fork on the door. Figure 7. View of enclosure mounted latch plates. Locking Pins in Unlocked Position WARNING: Barriers or enclosure door latch parts removed to service the equipment must be re-installed in the exact location for safe operation. Non-compliance with these instructions could lead to serious injury. Mark the location of these items with ink for ease of re-assembly. Locking Pins in Locked Position Figure. View of locking pins on medium voltage door. Arc Resistant Medium Voltage Motor ontrol

Isolation Switch Handle, ontactor Mechanical Interlock The Limitamp AR vacuum starter is equipped with a quick-make/ quick-break isolation switch in each starter. The isolation switch is not designed to make or break motor load current. To ensure that the isolation switch handle cannot be operated when the contactor is energized, a mechanical interlock mechanism is provided between the contactor and the isolation switch handle. Operation of this mechanical interlock for each starter should be checked per the following procedure. Step 1: Adjust the nuts to shift the connecting rod position as shown in Figure 10. Step 2: With the contactor de-energized and in the open position, the connecting rod should be adjusted such that the pusher rod will freely pass through the round hole in the connecting rod. Step 3: Once adjusted, tighten the two nuts against the block. onnecting Rod Pusher Rod WARNING: onfirm the equipment is de-energized before performing this check. Adjustment Nuts On the Interlock Assembly Figure 10. View of unblocked Pusher Rod when the contactor is open. Figure 8. View of the contactor to isolation switch mechanical interlock at the vacuum contactor. Pusher Rod Blocked Figure 11. View of blocked Pusher Rod when the contactor is closed. Figure 9. Adjusting connecting rod To verify that the interlock is properly adjusted, press or hold down moveable armature on top of the contactor. Press the silver handle latch. The mechanical interlock should prevent the silver handle latch from going in and prevent the handle from being moved. Arc Resistant Medium Voltage Motor ontrol 5

Medium Voltage oor efeater Latch WARNING: The following steps should be taken only as a last resort to enter a malfunctioning controller. It is imperative that all power to main bus be removed before proceeding. IN ASE OF EMERGENY, remove all power to the controller, then the medium voltage door may be opened with the contactor in the closed position and with the isolation switch closed, by following the procedure listed below. WARNING: o not proceed unless all power to the controller is removed. In this situation, doors must not be opened with power connected to the bus. Step 1: Remove the door interlock defeater locking nuts shown in Figure 12. Step 2: Pull down the door latch operating handle to disengage the multiple door latches on the inside of the medium voltage door. Step 3: Unscrew all flange nuts simultaneously until disengaged. Step : You should be able to open the medium voltage door by pulling out on the silver handle. As you pull on the door, the door interlock defeater will pull away from the door. WARNING: efeating medium voltage door interlock leaves the power fuses and contactor connected to the bus. The bus power must remain de-energized while the medium voltage door is open. oor Interlock efeater Locking Nuts oor Interlock efeater Figure 12. View showing door interlock defeater locking nuts. Figure 13. View showing door interlock defeater. Arc Resistant Medium Voltage Motor ontrol

Low Voltage Box Wiring etails Step 1: All low voltage wiring entering and exiting the low voltage compartment must be routed through the bushings provided on the box. Step 2: Once all wiring is complete, fill the bushings with R.T.V or other equivalent sealant material. Step 3: Wrap the outside of bushings and wiring with 3M, 130 tape. Tape must extend down the wire bundle a minimum of inches. Refer to figure 1 for details. WARNING: Ensure all wire way openings are properly sealed before energizing. Bushing Provided for ustomer Wiring Purpose Plenum Installation Guide The Limitamp AR design requires the use of a ventilation plenum to route any arcing gases and particles away from the equipment. Each section requires a plenum. Extra extension plenum parts can be used to exhaust the arcing gases and particles out of the building. The plenum parts are shipped with the equipment. It is the end user s responsibility to install the plenum part on the Limitamp AR enclosure. Store the plenum or extension plenums on a level surface to avoid distortion. Ensure they are kept in clean and dry condition with ample air circulation before installation. NOTE: It is NOT recommended to store the plenum outdoors. At the installation site, remove all separately packaged components shipped inside the Limitamp AR unit. Locate the plenums, cover plates and mounting hardware and place them in the work area. It is recommended that the plenum parts be installed in the sequence listed below. WARNING: Allow at least 12 feet of unobstructed space for exhaust gases. Otherwise, serious injury or death may occur. Step 1: Before installing the plenum system, remove all plastic snap-in clips in the top vent flaps of the Limitamp AR enclosure to ensure vent flaps operate properly. Step 2: Apply a strip of sealer around the top perimeter of the first shell. should be placed on the outside of the mounting holes on the shell top. Step 3: Lift plenum box for the first section with appropriate means and place it on top of the unit, taking care not to damage the vent flaps on top of the Limitamp AR enclosure. Properly Sealed and Taped Bushing Figure 1. Low voltage box wiring. Figure 15. Apply sealer around the top perimeter of the shell. Arc Resistant Medium Voltage Motor ontrol 7

Step : Align holes on top of enclosure and the plenum. Attach the plenum using the 3/8 hardware provided with kit, as shown in Figure. Step 5: Apply sealer around perimeter of the plenum side that will be closed. Figure. View of hardware to mount plenum to top of enclosure. Figure 17. Apply sealer on closed end of plenum. Step : Mount plenum end cover using 3/8 hardware. Refer to Table 1 for torque details. 3/8 Hardware 3/8 Hardware Torque Recommendations. Table 1 Bolt Size SAE Grade 5 Bolt Torque (Ft-lb) 1/ - 20 5/ - 18 9 3/8-1/2-13 39 Figure 18. Mount end cover plate on plenum. Arc Resistant Medium Voltage Motor ontrol 8

Step 7: Apply sealer around perimeter of the other side of the plenum and on the top of the second shell. Step 9: Apply a layer of sealer on the bottom plate of the first extension plenum. Attach bottom plate to the plenum. Figure 19. Application of sealer to plenum and shell. Step 8: Lift second plenum and position to align holes. Bolt the second plenum in place. Install 3/8 hardware in all holes between the plenums and to the top of the shell. Bolts Installed to Seal Joint Figure 21. Mount extension plenum bottom plate in place. Step 10: Apply a layer of sealer to the open end of the plenum that is mounted on the end of the lineup. Lift the extension plenum and hold it in place until bolts can be mounted to attach the two plenums together. Extension plenum should be supported. Figure 20. Bolting the plenums together Figure 22. Assemble the extension plenum using 3/8 Hardware. Arc Resistant Medium Voltage Motor ontrol 9

Step 11: ontinue the assembly of extension plenums following the same procedure. At the end of the final extension plenum, the end duct assembly must be installed. End uct Turned Extension Plenum Installation Guide (Front/Rear) At the installation site, remove all separately packaged components shipped inside the Limitamp AR unit. Find the Turned Plenum, and mounting hardware and place them in the work area. Step 1: Remove top cover plate on existing extension plenum for assembly. Apply sealer around perimeter of existing extension plenum side flanges, where turned plenum (Front/ Rear) will be attached. 3/8 Hardware 3/8 Hardware Figure 23. Assembly of end duct to the last segment of the plenum. If the customer chooses to install their own version of end duct segment, the duct must allow a minimum open exhaust area of 28 in 2. Step 12: Once all the plenums are in place and bolted together, apply a gasket around the perimeter of each plenum frame and mount the cover plates using 3/8 hardware. Figure 25. Apply sealer around perimeter of plenum. Step 2: Install 3/8 hardware to fasten the turned plenum (Front/Rear) to the extension plenum. 3/8 Hardware Figure 2. Mount top covers using 3/8 diameter bolts. Figure 2. Use 3/8 hardware to mount turned plenum (Front/Rear). Arc Resistant Medium Voltage Motor ontrol 10

Step 3: Apply sealer around perimeter of turned plenum (Front/Rear) flanges where extension plenum will be attached. Step 5: Once all the plenums are in place and bolted together, apply sealer around the perimeter of each plenum frame and mount the cover plates using 3/8 hardware. Figure 27. Apply sealer around perimeter of turned plenum (Front/ Rear). Step : Install 3/8 hardware to fasten the extension plenum to turned plenum. Figure 29. Assemble top covers using 3/8 diameter bolts. Turned Extension Plenum Installation Guide (Up/own) At the installation site, remove all separately packaged components shipped inside the Limitamp AR unit. Find the Turned Plenum, and mounting hardware and place them in the work area. 3/8 Hardware Figure 28. Use 3/8 hardware to mount extension plenum. Step 1: Remove top covers on existing extension plenum for assembly. Apply sealer around perimeter of existing extension plenum side flanges where turned plenum (up/down) will be attached. Figure 30. Apply sealer around perimeter of plenum. Arc Resistant Medium Voltage Motor ontrol 11

Step 2: Install 3/8 hardware to fasten the turned plenum (top/bottom) to the extension plenum. Step : Install 3/8 hardware to fasten the extension plenum to turned plenum. 3/8 Hardware 3/8 Hardware Figure 31. Use 3/8 hardware to mount turned plenum. Step 3: Apply sealer around perimeter of turned plenum (top/ bottom) flanges where extension plenum will be attached. Figure 33. Mount extension plenum on turned plenum (up/down). Step 5: Once all the plenums are in place and bolted together, apply sealer around the perimeter of each plenum frame and mount the cover plates using 3/8 hardware. Figure 32. Apply sealer around perimeter of turned plenum. Figure 3. Use 3/8 hardware to mount cover plates. Arc Resistant Medium Voltage Motor ontrol 12

Limitamp AR Extension Plenum Limitamp AR Extension Plenum - Straight Limitamp AR Extension Plenum Elbow Up/ own 2 H 2 H 2 L Extension Plenum Type Part number L (in) H (in) (in) Approx. Weight (lbs) 12 straight 55B52892ENG 12 2 2 90 22 straight 55B52892ENG1 22 2 2 135 2 straight 55B52892ENG5 2 2 2 10 3 straight 55B52892ENG2 3 2 2 195 0 straight 55B52892ENG3 0 2 2 215 8 straight 55B52892ENG 8 2 2 250 Note: 2 inch bottom cover plate has ø 0.35 holes to support the extension plenum Extension Plenum Type L Part number L (in) H (in) (in) Note: Rotate the extension plenum suitably to create up/down elbow Limitamp AR Extension Plenum End uct Approx. Weight (lbs) Up/own Elbow 55B52892GJG1 2.5 2.5 1.5 300 Limitamp AR Extension Plenum Elbow Front/Rear L H H 2 Extension Plenum Type Note: Rotate the extension plenum suitably to create Front/Rear elbow L Part number L (in) H (in) (in) Approx. Weight (lbs) Front /Rear Elbow 55B52892FZG1 2 20 Extension Plenum Type Part number L (in) H (in) (in) Note: End duct will be provided with a Rodent screen Approx. Weight (lbs) End uct 5582150ALG1 15 2 2 0 Arc Resistant Medium Voltage Motor ontrol 13

Extension Plenum General Guidelines 1. Support the Extension plenum at a minimum, every 0 inches throughout the straight length. 2. Straight lengths can be used along with Front/Rear and/or Up/own elbows to fit the customer layout. 3. Use the bottom cover plate with 0.35 inch diameter holes for supporting the extension plenum.. If required, contact the GE factory to order collars that may be installed on the plenum to support the straight extension plenum from the top. 5. Extension plenums are constructed using 12 gauge sheet metal.. Allow a minimum of 7 inches straight length between turns when designing the layout of the extension plenum. 7. ustomers may install their own version of End duct. Ensure a minimum exhaust area of 28 in 2. Follow local code requirements. 8. Refer to installation section for assembly of extension plenums. Arc Resistant Medium Voltage Motor ontrol 1

Plenum Flange details to connect the plenum extension or End uct Straight extension plenum with ollar installed (Side View) ollar ollar ollar Bottom over plate Arc Resistant Medium Voltage Motor ontrol 15

able Entry From Top or Bottom Removable cable entry plates are provided on the top and bottom of the equipment. Step 1: Remove cable entry cover plates. ut an appropriate size hole for required conduit bushing. Step 2: Install a conduit bushing(s) capable of sealing against 20-psig minimum pressure on all cables entering or exiting the arc resistant unit. WARNING: onduit bushings capable of sealing against 20-psig minimum should be installed on all cables entering or exiting the enclosure. If these bushings are not installed, hot arc gases can escape thru open area around cables. Serious injury or death may result. onduit Bushing Plenum onduit utout over Plates Figure 37. Assembly of conduit bushing on the bottom conduit plates for bottom cable entry. imensions imensions vary according to controller type. For dimension details of 00 Amp starters, refer to Figures 38 and 39. For dimension details of 800 Amp starters, refer to Figure 0. Figure 35. onduit cover plate in plenum for top cable entry. onduit Bushing Figure 3. Assembly of conduit bushing on to the plenum top cover for top cable entry. Arc Resistant Medium Voltage Motor ontrol

Limitamp AR Medium Voltage Motor ontrol R19 AR 00A, Stationary or raw-out, Outline imensions 200-7200 Volts, Two-High, Bottom able Entry. 2 High, 3 Wide 2 18 3 12 13 E T3 T1 7 1 2 18 1 1 11 2 L2 1 L2 L3 1 3 2 B1 11 1 L3 2 7 1 2 7 13 8 13 B2 9 52 H 5 13 T1 T3 GE Limitamp AR Medium Voltage Motor 8 ontrol Enclosures 2 8 7 R19 AR 00A, 2 High, 0" Wide 10 (Stationary or raw-out)-btm ABLE ENTRY 3 G 32 Enclosure Outline dimensions 200-7200 Volts 1 2 1 15 9 7 1 11 11 3 19 1 13 T1 T1-T3 T3 UPPER UNIT LOWER UNIT 2-HI add 0.12 3 1 90 for welded bottom plate 20 15 2 L.H.SIE VIEW -2200 lbs 998 Kg BTM ABLE ENTRY 11 3 3 VIEW FLOOR PLAN 2 High, 0 Wide 8 13 12 13 E 52 T3 2 L.H.SIE VIEW 18 3 7 1 2 18 1 1 11 2 L2 1 L2 L3 1 3 2 B1 11 1 L3 2 7 1 2 B2 5 13 2 7 8 T1 T1 T3 H 8 Notes: Notes: B1 B1 A Power A Power Bus, Bus, 1200A 1200A B2 B2 A Power A Power Bus, Bus, 3000A 3000A ontrol ontrol Lead Lead Terminal Terminal Board Board Motor Motor Lead Lead Terminal Terminal onnection onnection E E Ground Ground Bus Bus Terminal Terminal onnection onnection G G Space Space Required Required to Open to Open oors oors 135 135 H H Four-foot Four-foot Aisle Aisle for ontactor for ontactor Removal Removal J J Mounting Mounting Holes Holes for 1/2" for 1/2" iameter iameter Anchor Bolts Arc M Resistant Recommended Medium Voltage Position Motor for ontrol Incoming G 3 1 2-250 lbs 1112 Kg 7 13 9 BTM ABLE ENTRY 1 15 9 7 1 11 11 3 19 1 13 15 3 Motor onduit N Recommended Position for Incoming ontrol onduit Indicates Terminal Location - Approximate for able Length 10 3 T1 T1-T3 T3 UPPER UNIT LOWER UNIT 2-HI 0 VIEW 3 1 90 20 15 2 add 0.12 for welded bottom plate M 17 3 M 8 13 H Four-foot Aisle for ontactor Removal J Mounting Holes for 1/2" iameter Anchor Bolts M Recommended Position for Incoming Motor onduit N Recommended Position for Incoming ontrol onduit Indicates Terminal Location - Approximate for able Length Approximate Weight 2 5 8 1 1 2 N 10 2 1 2 2 5 FLOOR PLAN 1 1 2 UPPER UNIT LOWER UNIT 2 TYP. J 3 TYP. 17

Limitamp AR Medium Voltage Motor ontrol R19 AR 00A, Stationary or raw-out, Outline imensions 200-7200 Volts, Two-High, Top able Entry. 2 High, 3 Wide L2 L3 8 13 11 11 2 7 8 L2 L3 52 12 13 1 2 E 1 3 5 13 1 2 T1 T3 B2 B1 T1 T3 2 L.H.SIE VIEW 7 1 2 7 1 2 10 3 G 32 17 3 8 18 1 1 2 18 H 8-2200 lbs 998 Kg 75 8 5 3 7 8 TOP ABLE ENTRY 13 1 2 3 8 3 3 2 9 7 18 11 11 3 T1-T3 T1 T3 UPPER UNIT LOWER UNIT 2-HI 3 VIEW 20 15 2 add 0.12 3 1 90 for welded bottom plate 17 3 8 13 2 5 8 1 1 2 N M M 2 1 2 TOP VIEW LOWER UNIT UPPER UNIT 2 5 FLOOR PLAN 1 1 2 2 TYP. J 3 TYP. 2 High, 0 Wide 11 L2 12 13 1 2 E 1 2 T1 T3 7 1 2 7 1 2 1 2 13 T1-T3 UPPER UNIT 2 17 3 8 13 2 5 8 N M M LOWER UNIT UPPER UNIT 2 1 2 10 TOP VIEW 2 5 L2 L3 8 13 11 2 7 8 L3 52 1 3 5 13 B2 T1 2 B1 T3 L.H.SIE VIEW 10 3 G 3 17 3 8 18 1 18 H 8-250 lbs 1112 Kg 75 8 5 3 7 8 TOP ABLE ENTRY 3 3 8 9 3 2 9 7 18 11 Notes: Notes: B1 A Power Bus, 1200A B1 B2 A Power A Power Bus, Bus, 1200A 3000A B2 A Power ontrol Bus, Lead 3000A Terminal Board ontrol Motor Lead Lead Terminal Board onnection E Motor Ground Lead Bus Terminal Terminal onnection onnection E G Ground Space Bus Required Terminal to onnection Open oors 135 G H Space Four-foot Required Aisle to for Open ontactor oors 135 Removal H J Four-foot Mounting Aisle Holes for ontactor for 1/2" iameter Removal Anchor Bolts J Mounting Holes for 1/2" iameter M Recommended Position for Incoming Motor onduit Arc Resistant N Recommended Medium Voltage Position Motor for ontrol Incoming ontrol onduit Indicates Terminal Location - Approximate for able Length Approximate Weight 15 3 T1 T3 0 LOWER UNIT 2-HI VIEW 3 1 90 20 15 add 0.12 for welded bottom plate H Four-foot Aisle for ontactor Removal J Mounting Holes for 1/2" iameter Anchor Bolts M Recommended Position for Incoming Motor onduit N Recommended Position for Incoming ontrol onduit Indicates Terminal Location - Approximate for able Length Approximate Weight 1 1 2 FLOOR PLAN 1 1 2 J 2 TYP. 3 TYP. 18

Enclosures Enclosure Outline dimensions 200-7200 Volts R19 AR 800A, 1-High, 8" Wide Limitamp AR Medium Voltage Motor ontrol R19 AR 800A, Stationary or raw-out, Outline imensions 200-7200 Volts, One-High, Top/Bottom able Entry. -1/2 7 17-5/8 10 5-3/ E 12-1-3/ B1 2-9/ 10-1/2 E 10-5/8 X 2-3/ -1/2 1 B L2 2-9/ 10-1/2 L2-1/2 5-1/2 12-1/2 L3 X P L3 2 1 K 8-7/ -3/ 11-1/2 M -1/2 13-1/2 P 72 8-/5 2-1/2 7 10-1/2 K 8-7/ 7-9/ N 3-1/2 52 M T1 T3 T1,T3 17-5/8 10-1/2 5-3/ 7 F E 12-3/ F 7-9/ N 9 3-1/2 17 G H 2-1/2 1-3/ 17-5/8 B1 E 2 10 5-3/ 10-5/8 8 27-3/ E 12-3/ TOP VIEW X 2-3/ 9 2-1/2 9-3/ 1-3/ B1-1/2 E B 10-5/8 TOP VIEW L2 X L2 2-3/ -1/2-1/2 5-1/2 12-1/2 2 2 1-1/2 1-1/2 8 B L3 L2 X L3L2-1/2 5-1/2 12-1/2 L.H.SIE 2 VIEW 1-1/2 add 0.12 1-1/2 VIEW L3 X -3/ L3 11-1/2 90 for welded - 1800 LBS. add 0.12-1/2 13-1/2 10-1/2 1-3/ - 8 KG. 72 bottom plate 11-1/2 90 for welded 2 8-/5-1/2 13-1/2 10-1/2 1 10-1/2 72 bottom plate P 2 8-/5 2 10-1/2 2 P N 52 Notes: T1 T3 T1,T3 2 8-7/ 2 N 52 F T1 T3 K F T1,T3 8-7/ F H B Incoming Power Terminal onnection M 17 G F K K 3 H M 2 17 G K 3 8 27-3/ B1 A Power Bus, 800A 2-5/ 7-9/ 1-5/ 2 8 9 27-3/ 2-5/ 7-9/ 1-5/ 9-3/ -3/ ontrol Lead Terminal Board 3/ 3/ Motor Lead Terminal onnection 10-1/2 10-1/2 J J 2 2 8 E Ground Bus Terminal onnection L.H.SIE L.H.SIE VIEW VIEW VIEW FLOOR FLOOR PLAN PLAN F Ground Bus Terminal onnection - 1800-1800 LBS. LBS. - 8-8 KG. KG. (If Ordered) 1 High, 8 Wide Notes: Notes: B Incoming Power Terminal onnection B Incoming Power Terminal onnection B1 A Power Bus, 800A B1 A Power ontrol Bus, Lead 800A Terminal Board ontrol Motor Lead Lead Terminal Terminal Board onnection Motor E Ground Lead Terminal Bus Terminal onnection onnection E Ground F Ground Bus Terminal Bus Terminal onnection F Ground (If Bus Ordered) Terminal onnection (If G Ordered) Space Required to Open oors 90 G Space H Four-Foot Required Aisle to Open for contactor oors 90 removal J Mounting Holes for 1/2" iameter Anchor Bolts H Four-Foot Aisle for contactor removal K J Space Available for Incoming onduit Mounting M Holes for 1/2" iameter Anchor Bolts Recommended Position for Incoming Motor onduit K Space N Recommended Available for Incoming Position for onduit Incoming ontrol onduit M Recommended P Position for Incoming Motor onduit Recommended Position for Incoming Power onduit N Recommended X LV Box Position for Incoming ontrol onduit P Recommended Indicates Terminal Position Location for Incoming - Approximate Power onduit for able Length X LV Box Approximate Weight Indicates Terminal Location - Approximate for able Length Approximate Weight G Space Required to Open oors 90 H Four-Foot Aisle for contactor removal J Mounting Holes for 1/2" iameter Anchor Bolts K Space Available for Incoming onduit M Recommended Position for Incoming Motor onduit N Recommended Position for Incoming ontrol onduit P Recommended Position for Incoming Power onduit X LV Box Indicates Terminal Location - Approximate for able Length Approximate Weight Arc Resistant Medium Voltage Motor ontrol 19

Reference Publications Standard, non-arc Resistant Limitamp Vacuum ontactors Installation Instructions Application and Selection Guide Load-Break Switches Installation Instructions Vacuum ontactors, Renewal Parts Bulletin Limitamp AR Limitamp AR Application Guide Limitamp AR Product Flyer GEH-530 GEH-23 GET-80 GEH-28 GEF-80 ET-75 EA-527 GE Industrial Solutions 1 Woodford Avenue Plainville, T 002 www.geindustrial.com 201 General Electric ompany Information provided is subject to change without notice. Please verify all details with GE. All values are design or typical values when measured under laboratory conditions, and GE makes no warranty or guarantee, express or implied, that such performance will be obtained under end-use conditions. EH-790B 10/1