Product guide. Enclosed NEMA starters. Answers for industry.

Similar documents
Product Guide. enclosed NEMA STARTERS

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

Product Guide. NEMA pump controls.

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

SIGNAL WORDS QUALIFIED PERSON

NEMA Pump Controls. Class 82 slim line NEMA pump controller for the agricultural industry

Product Specification Sheet #3LD2.1

Design Standard. Purpose: Design Standard:

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

BAC Custom Engineered Controls

The Perfect Fit. Introducing the Next Generation of SINAMICS PERFECT HARMONY GH180 Air-Cooled Drive. usa.siemens.

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.

Overview V10-T1-2 V10-T1-2 V10-T1-3 V10-T1-4 V10-T1-5 V10-T1-6 V10-T1-7 V10-T1-7 V10-T1-8

SECTION MOTOR CONTROL

Application Description

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

Selection Guide Motor Control Device Solutions

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy. Reliable.

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

ProCS and ProC Series Heat Trace Panelboards

ECN A A A - B - C - D - E - F - A - B - C - D - E - F - NEMA Size 5 - Size Size Size Size Size 9

Power Mod. Introduction.

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters 1. Contents

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Selection and application guide

SIMOVAC and SIMOVAC-AR. Medium-voltage controllers 2.3 kv kv. usa.siemens.com/simovac

Controls Express. A wide selection of enclosed NEMA controls now available with faster shipping as a standard. Fast. Easy.

Enclosed Full-Voltage Starters

Enclosed Full-Voltage Starters

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

ROBICON W120 enclosed drive

General purpose cast iron frame motors. The right choice for optimal durability, efficiency and performance. SIMOTICS NEMA Low Voltage Motors

Enclosures for hazardous areas EBMX clamped enclosures. Clamped EBMX. NEMA 7 classifi ed enclosures

Enclosures. See Section Typical Description

Self-protected Combination Starters System PKZ 2-SP

General purpose aluminum frame motors. The right choice for efficiency and performance. SIMOTICS NEMA Low Voltage Motors.

XT SERIES Jockey Pump Controllers Features

Power Mod. Standard Tapboxes.

SECTION PANELBOARDS

Instruction and Installation Guide

MAGNETIC MOTOR STARTERS

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Selection and application guide

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Bolted contact switches. Pringle switches

Simply the right choice. The latest generation of SIRIUS motor controls: fully optimized for IE3/IE4 motors. siemens.com/sirius

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Raising the bar on end-to-end conveyor solutions. SIMOGEAR High-efficiency Geared Motors.

Specialty Service Entrance Switchboards. Selection and Application Guide

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

Multi-Pak Group Control

Transfer switch OTEC open or delayed transition

Severe duty cast iron frame motors

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

3. Coils shall be of molded construction

Innovation fuels our passion for reliable performance

SECTION ENCLOSED CONTROLLERS

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Series 774 Automatic Skid Package

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Gas-insulated medium-voltage switchgear. For the metal industry. Answers for energy.

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

NEMA Contactors & Starters (Freedom)

SWITCHGEAR DIVISION PRODUCT PROFILES

Wastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Dry-Type Transformers Mini-Power Centers

1.1. Switching Devices DH N D K LW. Safety Switches. Catalog Number Selection. Double-Throw, continued 1. Safety Switch

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Electromagnetic Industries LLP

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

OTEC Transfer switch open transition

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Wastewater Solutions

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

EPS-ECONOMY PUMP STARTER

Motor Control Centers (MCC) Identification Guide. Answers for industry.

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

TABLE OF CONTENTS. Description Page Description Page. SETI Finland. Approvals:

Typical Specification

Introduction. Upon completion of Motor Control Centers, you should be able to: Explain the role of motor control centers in a distribution system

Gas-insulated medium-voltage switchgear. For marine and offshore applications. Answers for energy.

Instruction sheet WARNING. October, 2014

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

C1000 Series Automatic Cap Bank

AF series contactors (9 2650)

Pump Installation and Service Manual HRS Hydromatic Retractable System

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Benefits. Safety. Durability. Performance. Russellstoll. Heavy Industrial/ Marine

Industrial Control Transformers

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Modifiable TITAN Horizontal Motors Accessories and Modifications

GE 8000-Line Motor Control Centers

Transcription:

Product guide Enclosed NEMA starters Answers for industry.

The right choice for applications that demand the best Siemens NEMA combination and non-combination starters for industrial and construction applications Rugged, reliable, flexible and safe performance. In an increasingly competitive marketplace, all of these factors are essential to success, particularly when it comes to assuring reliable motor protection and control. Whether you re a consulting engineer, a contractor, or a plant manager, protecting the performance of your motors is a critical priority. And one of the best ways to do so is with worldclass Siemens enclosed starters. Our enclosed NEMA starters are engineered for rugged performance, manufactured to be dependable, designed to improve safety, prewired to save on installation costs and can be easily modified in the field. All starters are UL listed and CSA certified. A comprehensive starter selection Siemens manufactures a broad range of starters designed to meet all of your most demanding applications. Included in our line of NEMA starters are full and reduced voltage starters, reversing and non-reversing starters as well as two-speed starters. Starter sizes range from 00 to 8 including Siemens exclusive motor-matched half-sizes which saves you money and space. Siemens exclusive half-size starters Non-Reversing Non-Combination: Class 14 Combination: Class 17, 18 Reversing Non-Combination: Class 22 Combination: Class 25, 26 Two-Speed Non-Combination: Class 30 Combination: Class 32 Half-Size starters feature all the rugged performance characteristics of our NEMA rated starter sizes, but are fractionally sized to more closely match your exact motor rating. As a result, significant economic savings are made possible without sacrificing the reliability you expect from a heavy duty starter. Exclusive half-sizes save potentially hundreds, even thousands of dollars per project. Every half-size starter saves you money up to 31% as illustrated in the table. All half-sizes comply to applicable UL standards. Savings with Half-size Class 14 starters in Type 1 enclosures Half-size Motor size Starter Half savings over 230V 460V size size next full size 7¹ ₂ 10 1 10 15 1³ ₄ 31% 15 25 2 20 30 2¹ ₂ 20% 30 50 3 40 75 3¹ ₂ 13% 50 100 4 2 Enclosed NEMA starters product guide

Motor overload protection ESP200 solid-state overload relays The ESP200 solid-state overload relays offer superior protection. In addition to overload protection, they include phase loss protection, phase imbalance protection and ground fault detection. As standard they include selectable trip class 5, 10, 20 and 30 as well as selectable manual, auto & remote reset modes. Ambient compensated bimetal overload relays Siemens also offers ambient compensated bi-metal overload relays. These relays are designed to compensate for the ambient air temperature surrounding the overload. This helps to prevent the occurrences of nuisance tripping. Additionally, they are automatic or manual reset selectable. 3UF7 Pro intelligent motor protection SIMOCODE offers advanced motor protection and functionality including communication capabilities. Short-circuit protection (combination starters) Disconnect switch With its rugged construction, the disconnect switch provides high fault withstanding of up to 100,000 Amp when fused with Class J or R fuses. Circuit breaker The circuit breaker employs adjustable magnetic trip settings to allow broader application ranges and a higher degree of motor short circuit protection. It provides high fault withstanding of up to 100,000 Amp Enclosed NEMA starters product guide 3

A comprehensive line of enclosures to meet your application requirements Type 1 painted enclosures For Indoor Use General Purpose Type 3/3R/4/12 painted enclosures For indoor or outdoor use Rain proof Dust tight Watertight Type 4/4X stainless steel enclosures For indoor or outdoor use Rain proof Dust tight Watertight Corrosion resistant 304 stainless steel standard (316 optional) Type 4/4X fiberglass enclosures For indoor or outdoor use Rain proof Dust tight Watertight Corrosion resistant Type 3/4/7/9 bolted enclosures For indoor or outdoor use Rain proof Dust tight Watertight Hazardous gas and vapor atmosphere Hazardous dust atmosphere Hazardous fibers and flyings atmosphere 4 Enclosed NEMA starters product guide

Class 14 non-combination starter with lift-off cover in Type 1 enclosure 12) 13) 1) 11) 2) 10) 9) 3) 4) 5) 8) 7) 6) Features and benefits 1) Compact enclosure to minimize required mounting space (four enclosure sizes to accommodate starters with and without CPT and other optional panel mounted devices) 2) Powder coat painted and corrosion resistance tested per UL to give superior appearance and protection 3) Inside cover wiring diagrams include modifications and field kit part numbers for easy troubleshooting and field modifications 4) External reset button provides means to reset the overload relay without opening theenclosure 5) Convenient knockouts for up to one pilot device and two pilot lights for quick easy modifications 6) Each pilot light field kit includes red, green and amber colored lens along with a variety of legends for maximum flexibility 7) Pilot devices and lights offered as factory installed for convenience and as field kits for flexibility (all size enclosures with lift-off covers utilize the same pilot devices and lights to reduce inventory) 8) Captive threaded fastener and padlock provision for easy access and while avoiding unauthorized entry 9) Heavy-duty NEMA starter to prove reliable motor control and protection expected n the most demanding applications 10) Predrilled holes for easy mounting of standard options 11) Up to twelve combination conduit knockouts for maximum installation and wiring flexibility 12) Both case and cover are fabricated with TOX process resulting in joints more consistently reliable than from conventional spot welding 13) Three point raised mounting for easy installation on uneven surfaces Enclosed NEMA starters product guide 5

Features and benefits 1) Powder coat painted and corrosion resistance tested per UL to give superior appearance and protection 13) 14) 15) 2) NEMA 3/3R/4/12 enclosure (not shown) is fabricated with galvannealed steel versus conventional cold rolled steel for superior corrosion resistance 1) 3) Disconnect handle accepts 3 3/8 padlocks in off position for safe maintenance 4) Disconnect door interlock with defeater permits authorized access while preventing unauthorized access when unit is energized 5) Door hasp allows unit to be padlocked to prevent unauthorized access and tampering 6) Rugged 30 mm pilot controls meet Type 3, 4, 12, and 13 specifications and are oil and dust tight for durability 7) Convenient knockouts for up to four pilot controls for quick easy modifications 8) Multiple conduit knockouts on top and bottom for ease of installation and wiring flexibility 9) Heavy-duty quarter-turns for fast entry and proper sealing of enclosure 12) 10) 3) 4) 5) 10) Door is easily removable for ease of installation and maintenance 11) NEMA 3/3R/4/12 enclosure (not shown) is fully gasketed to ensure a dust tight and water tight seal 12) Predrilled holes for easy mounting of standard options 6) 13) Heavy-duty disconnect switch with visible blades for safety and double break switch action to reduce arcing and increase lifetime 7) 14) Three point raised mounting for easy installation on uneven surfaces 15) Line side shield to help guard personnel from contact with live parts 9) 8) Class 17 Combination starter with fusible disconnect switch in Type 1 enclosure 6 Enclosed NEMA starters product guide

Class 36 and 37 electromechanical reduced voltage starters Siemens manufactures the three commonly used electromechanical reduced voltage starters. Each one is designed for specific application requirements and consists of auto transformer, wye-delta and partwinding starters. The reduced voltage starter: Reduces inrush current Provides smoother acceleration of the load Reduces starting torque Reduces stresses on mechanical linkages Combination and non-combination reduced voltage starter sizes range from 0 to 6 including Siemens exclusive motor matched half-sizes. Enclosure types include 1, 3R/12, 4 painted and 4/4X stainless steel. All starters are UL listed and CSA certified. Auto transformer starter Maximum torque per amp Three coil auto transformer for balanced starting currents 50, 65 and 80% voltage taps Closed circuit transition Adjustable starting time ESP200 overload relay as standard CPT supplied as standard Wide range of factory modifications Wye-Delta starter Lowest starting torque Closed or open circuit transition Adjustable starting time ESP200 overload relay as standard CPT supplied as standard Wide range of factory modifications Part-winding starter Simplest design most economical Adjustable starting time ESP200 overload relay as standard CPT supplied as standard Wide range of factory modifications Note For reduced voltage electronic soft starters, please refer to catalog or contact your local Siemens sales office. Enclosed NEMA starters product guide 7

Get more information Refer to the additional brochures listed below for information on other NEMA and general purpose control products. Order on-line via the Siemens Literature Fulfillment System or contact your local Siemens sales office. Open NEMA Starters Publication No. NEBR-OLRPG-0109 ESP200 Solid State Overload Relay Publication No. NEBR-ESPSS-0908 Manual Motor Controls Publication No. NEBR-MANMC-0605 Pump Controls Publication No. NEBR-PUMPC-0605 Lighting and Heating Contactors Publication No. NEBR-LAHCO-0605 Control Power Transformers Publication No. NEBR-CPTRA-0605 Note The last four digits of the publication number indicate month and year of last revision and may change upon each revision. Siemens Industry, Inc. Industry Automation Division 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-964-4114 info.us@siemens.com www.usa.siemens.com/controls Subject to change without prior notice. Order No: NEBR-ENCST-0410 All rights reserved. Printed in USA 2010 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.