ZS6 Screw Clamp Terminal Blocks Feed-through

Similar documents
ZS10-PE Screw Clamp Terminal Blocks Ground

ZS35 Screw Clamp Terminal Blocks Feed-through

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS4-PE Screw Clamp Terminal Blocks Ground

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS4-PE Screw Clamp Terminal Blocks Ground

ZK6 PI-Spring Terminal Blocks Feed-through

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZK4-PE PI-Spring Terminal Blocks Ground

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZDP Pluggable Terminal Blocks Feed-through

ZP2.5-4P Spring Terminal Block Feed-through

ZP2.5-PE Spring Terminal Block Ground

DBL distribution blocks 3x1 pole

ZS4-SF1 Screw Clamp Terminal Block

Main catalogue. SNK Series Terminal Blocks Accessories Marking Solutions

Main catalog. SNK series Terminal blocks. Phone: Fax: Web: -

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Electronic overload relay EF65, EF96 and EF146

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Electronic overload relays EF205 and EF370

Thermal overload relay TF140DU and TF140DU-V1000

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

MS General Information Extended Product Type: MS

Thermal overload relay TF65 and TF96

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Manual motor starter MS116

Mini contactors B6, BC6 with 3 pole

Thermal Overload Relays

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Manual motor starter MS132

Manual motor starter magnetic only MO325

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Manual motor starter MS116

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DX³ RCCBs - ID 4P up to 100 A

AF40... AF96 3-pole contactors Technical data

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Manual motor starter MS132

Manual motor starter MS132

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

RX 3 M.C.B A up to 63 A

TX³ RCCBs 2P up to 100 A

RX 3 M.C.B A up to 63 A

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Voltage limiting device HVL

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

up to 63 A (1 module per pole)

Phase + Neutral, neutral on left side

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

Surge arrester POLIM-H..SD

Data Sheet DIN Rail Miniature Circuit Breakers Ex9 Series - B1NQ

Voltage limiting device HVL

ABB i-bus KNX DG/S x DALI-Gateway Basic

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Viking 3 - Screw connection Disconnect terminal blocks

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Transcription:

Technical Datasheet SNK6008D00 Catalogue Page ZS6 Screw Clamp Terminal Blocks Feed-through Save space by connecting conductors up to 6 mm² (without insulated ferrule, CB certified) 0 AWG in just 6 mm 0.36 in spacing, - Perfectly adapted to solar applications: voltage is rated 000 V AC / DC IEC. SNK60F004 SNK0004F0000 3D CAD outline drawings available on "Control Product 3D" portal SNC0496 F0000 Screw Clamp Terminal Blocks 6 mm² 0 AWG 6 mm 0.36 in Spacing Ordering Details Color Grey Blue Orange Yellow Green Red Purple Brown White Black Grey Blue Orange Yellow Green Red Purple Brown White Black Type ZS6 ZS6-BL ZS6-OR ZS6-YL ZS6-GN ZS6-RD ZS6-PR ZS6-BR ZS6-WH ZS6-BK Order Code SNK600R0000 SNK600R0000 SNK6030R0000 SNK6060R0000 SNK606R0000 SNK606R0000 SNK6063R0000 SNK6064R0000 SNK606R0000 SNK6066R0000 EAN Code 34796008 34796007 347960306 347960603 34796060 34796067 347960634 34796064 34796068 Pack (ing) 34796066 Weight ( pce) g Declarations and Certificates CE CB RoHS USR CNR CSA EAC Ex ATEX IECEx BR-Ex e II USR CNR Haz Loc BV RINA DNV ATEX Declaration

Declarations and Certificates CE CE CB CB RoHS RoHS USR CNR USR CNR SND00U0* SND60A0* SND3049F0* SND6040A0* CSA CSA SND6070A0* EAC Ex EAC Ex ATEX ATEX SND6004A7* IECEx IECEx SND600A7* BR-Ex e II BR-Ex e II SND604A0* USR CNR Haz Loc USR CNR Haz Loc SND6047A0* BV BV SND6073A0* RINA RINA SND6088A0* DNV DNV SND6087A0* Atex Declaration Atex Declaration SND8C0* Explosive Atmosphere: ATEX Classification Group Category IM II GD Ex eb I/II/IIIC Protection Method Ex e: increased security In the presence of explosive dust atmosphere, terminal blocks are to be installed in certified enclosure II D General Information The following information must be strictly adhered to in order to guarantee the terminal block electrical, mechanical and environmental performance. Protection Rail Wire stripping length IEC 60947- TH 3-7., TH 3- Denudage IP0 TH 3-7., TH 3-0. mm 0.4 in NEMA Operating tool Torque Flat screwdriver Tete de viscouple Screw clamp Flat screwdriver 4 mm 0.7 in 0.8 N.m 7. N.m ± 0. N.m ±.33 N.m Screw rail contact (Maximum value) Disconnect device Material Specifications Insulating material CTI Flammability Polyamide 600 V UL94 V0 NF F 60 IF Connecting capacity per clamp Rigid - Solid / Stranded conductor Flexible conductor Flexible conductor with non insulated ferrule Flexible conductor with insulated ferrule Gauge Ferrule maximum outer diameter or conductor insulation maximum outer diameter 0.... 6 mm² 0.... 6 mm² 0.... 4 mm² 0.... 4 mm² A4-B3 IEC 60947- Needle flame testec 606-- Compliant Screw clamp 4... 0 AWG 4... AWG 4... AWG 3 mm 0.8 in Ferrule. mm 0.6 in The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²). Technical Datasheet SNK6008D00 ABB

Multi Connecting capacity per clamp Rigid - Solid / Stranded conductors 0..... mm² 4... 4 AWG Flexible conductors 0..... mm² Flexible conductors with twin ferrule 0..... mm² 4... 4 AWG Don't mix solid and flexible conductors in the same clamp Don't mix solid or flexible conductors of different sizes in the same clamp The "Connecting capacity with ferrule" data is guaranteed with ABB crimping tool PS-3 (crimping capacity up to 0 mm²) Cross section Rated cross section 6 mm² 0 AWG Maximum Cross section 6 mm² 0 AWG Electrical characteristics Current Rated current 4 A Field and factory wiring Cat. Factory wiring Cat. UL 09 30 A UL 09 30 A CSA-C-. n 8 30 A Maximum Exe current IEC/EN 60079-7 4 A Rated short-time withstand current s (Icw) 70 A Short-time withstand current 0. s s 0 s 30 s min 84 A 74 A 40 A 0 A 64 A Rated short-circuit withstand current UL 09 Max. current (4 temperature increase) / Max. cross section (mm²) 4 A Maximum short circuit current (s) 70 A 6 mm² Short Circuit Current Rating (SCCR) SA UL 09 supplement SCCR With the following configurations: Suitable conductor wire range Maximum voltage Fuse class / Max. amp. Rating UL 09 00 ka 4... 0 AWG 600 V J 0 A T 0 A RK 00 A RK 30 A G 60 A CC 30 A Voltage Rated voltage IEC 60947-000 V Rated voltage UL 09 600 V Use Group UL 09 B, C Rated voltage CSA-C-. n 8 600 V Rated voltage Ex e IEC/ EN 60079-7 693 V Rated impulse withstand voltage IEC 60947-8000 V Dielectric test voltage IEC 60947-00 V Pollution degree IEC 60947-3 Overvoltage category IEC 60947- III ABB Technical Datasheet SNK6008D00 3

Temperature range Ambient temperature min/max Storage -... +0 C Installing -... +40 C Service -... +0 C -67... +30 F +3... +04 F -67... +30 F Current Derating curve for continuous service temperature SNK0086F0000 Dissipated power Maximum dissipated power at rated current Maximum dissipated power at maximum Exe current IEC 60947-.3 W IEC 60079-7 Rated power dissipation at an ambient temperature of 3 C - IEC 60947-7-3 Separate arrangement / Overload and short-circuit protection Separate arrangement / Exclusive short-circuit protection fuse and 4 feed-through blocks Compound arrangement / Overload and short-circuit protection Compound arrangement / Exclusive short-circuit protection fuse blocks Environmental Characteristics Additional climatic tests Dry heat Cyclic damp heat Cold Damp heat steady state IEC 60068- Compliant Temperature +00 C 96 h IEC 60068-30 Compliant Temperature + C Relative humidity Number of cycles ( cycle = 4h) IEC 60068- Compliant Temperature -40 C 96 h IEC 60068--78 Temperature Relative humidity Corrosion Salt mist IEC 60068- Compliant 96 h Concentration % SO ISO 6988 Compliant 48 h Concentration 0. dm³ Flowing mixed gas corrosion test IEC 60068-60 Number of the test method Compliant 3 j 4 Technical Datasheet SNK6008D00 ABB

Vibrations and shocks Sinusoidal vibrations IEC 60068--6 Compliant Frequency range 0... Hz Number of cycles 0 Acceleration 0 m/s² Functional random vibrations IEC 6373 Category Class B 3 axes Frequency range Acceleration Long life testing at increased random vibrations Category Class B 3 axes Shock Category Class B 3 axes ZS6 Terminal Block Accessories Compatibility Some accessories may modify the terminal block's rating. See complete information in the accessories catalog page. IEC 6373 Frequency range Acceleration IEC 6373 Acceleration Description Type Order Code Pack (ing) Weight pieces g ( pce) MG-CPM 3 SNB0479R06 680 0.73 3 4 4 6 7 7 8 9 0 0 3 3 3 3 3 3 4 End Sections End Stops End Stops Circuit Separators Circuit Separators Test Connectors Test Adapters Test Adapters Shield Connectors Cross Spacing Jumpers Protecting Covers Protecting Covers Protecting Cover Kits Tools Spacers MC6 MC6-YL MC6PA UMH PROCAP6 SAT6 PR3.G PR4 PR PR30 PR3.Z ES4 BAM4 BAZ CS CS-R TC-R TP TP4 SHBS JB8-3 CO PL6 KCO PS-3 JB6- JB6-3 JB6-4 JB6- JB6-0 JB6- ES-TC6 SNK000R0000 SNK004R0000 SNK9999R0000 SNK9006R0000 SNK9006R0000 SNK9006R0000 SNA64800R0300 SNA680R00 SNA68700R00 SNA730R00 SNA74300R700 SNK90R0000 SNK90000R0000 SNK90000R0000 SNK9000R0000 SNK90003R0000 SNK9000R0000 SNK90003R0000 SNK9000R0000 SNK900600R0000 SNK900603R0000 SNK900604R0000 SNK90069R0000 SNK90064R0000 SNK9006R0000 SNK90630R0000 SNK906303R0000 SNK906304R0000 SNK90630R0000 SNK90630R0000 SNK9063R0000 SNK9000R0000 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0.00 0.00.00 0.0 0.80 6.00 78.00 9.00 700 38.00 78.00.0 4.00.30 0.0.0.0.70.40 3..80 300.00.80 47.80 380.00.30.0.90 3.60 7.40 38.0 0.80 ABB Technical Datasheet SNK6008D00

Contact us ABB France Electrification Products Division PG Connection 3, rue Jean Perrin F-69687 Chassieu cedex / France Tel. +33 (0)4 7 7 Fax +33 (0)4 7 93 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 0 ABB All rights reserved SNK6008D00 - PDF