INSTALLATION INSTRUCTIONS

Similar documents
Installation Instructions

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

INSTALLATION, MAINTENANCE & OPERATION GUIDE. MODEL Sanuvair S300 WHOLE HOUSE HEPA/UV AIR PURIFIER. ITEM # Sanuvair S V EN

Installation Instructions

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Safety, Installation and Service Manual Models 1952, 1953 & 1972

UV-AIRE AIR PURIFYING SYSTEM

HARDWARE KIT INSTALLATION GLOVES

Model: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.

21", 33", 45", & 61" Installation & Operation Manual

UV-AIRE AIR PURIFYING SYSTEM

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

WARNING Risk of property damage, injury, or death.

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

BIO-FIGHTER 4Xtreme 21", 33", 45" Ultraviolet Light Systems

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

Installation Instructions

BIO-FIGHTER Triad FlexMount 1S and 2S Ultraviolet Light Systems

MINISTICK TM UV Germicidal Ultraviolet Light

ULTRAMAX AIR DISINFECTION SYSTEMS OWNERS GUIDE

Installer s Manual. PCO/UV N-Duct Model

MCI. SynAIRgPURE. Owner s Manual

Ultraviolet Systems RXIU-A02A, RXIU-A03A TREATMENT SYSTEMS

Page Number. Contents: Product Features 2. Physical Data 2. Nomenclature. 3. Blower Performance 3. Electrical Data 4. Warranty.. 6

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

1000 Watt Pure Sine Wave Power Inverter, Users Manual

Installation Instructions Electric Heaters 5 20 kw

User Information Manual

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

User s Manual and Operating Instructions

UV100A Ultraviolet Systems UV100A1000 AND UV100A1018 AIR TREATMENT SYSTEMS UV100A1059 AND UV100A2008 SURFACE TREATMENT SYSTEMS

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

ESE Series Cast Iron Sewage Pumps

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Installation Instructions Electric Heaters 5 20 kw

OWNER S MANUAL MODELS EADM900UV-VO-A & EADM900UV-VO-VS WHOLE-HOUSE DUCT MOUNT HEPA AIR CLEANER WITH ULTRAVIOLET LAMP & PHOTO CATALYTIC FILTER

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

CAUTION: Read manual carefully for proper procedures and operation.

AEROMOTIVE Part # GM LS1 Fuel Rails INSTALLATION INSTRUCTIONS

Air Curtain. Installation, Operating and Maintenance Instructions

Bottom Loading Water Dispenser

Installation Instructions

AEROMOTIVE Part # Ford 5.0 Liter INSTALLATION INSTRUCTIONS

Cincinnati, OH USA

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

AEROMOTIVE Part # Ford 5.4L Shelby GT500 Mustang INSTALLATION INSTRUCTIONS

PUREAIR AIR PURIFICATION SYSTEM PHOTOCATALYTIC OXIDATION (PCO) TECHNOLOGY

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

CTFRP Series Power Supplies

FOODSAFE IL INSTALLATION MANUAL

AQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter

AEROMOTIVE Volkswagen 1.8T Fuel Rail Part # INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # L 4V Fuel Rails INSTALLATION INSTRUCTIONS

Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

AQUA2000 From O3PURE

BC Series Multi-position Air Handler Engineering and Specification Guide (Electric and Water Heat)

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

Tank Monitor. Instruction manual DTM01. Tank Monitor

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Owner's Manual. For latest instructions please go to

QUALITY MISTING PUMPS

AEROMOTIVE Part # Subaru STI Fuel Rails INSTALLATION INSTRUCTIONS

Installation Instructions

For safety and to ensure proper use carefully read the contents of this manual before operating or installing the unit.

Installation & Maintenance of the Fresh-Aire UV Tubular Rack System for Commercial Air Handler Systems

c EDR /11. ShipShape OWNERS MANUAL. [ power foundations ]

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

16 Inch Hanging Pendant Barn Light

1. Contents 1. CONTENTS INTRODUCTION SAFETY WARNINGS POWER TILT STANDARD OPERATING INSTRUCTIONS... 5.

WARNINGS, CAUTIONS AND NOTES

MaxLite StaxMax LED Flood Lights

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Hazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual

Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Level One Electric Vehicle Charging Station Wall Mount Product Guide

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

18VDC ESB6 Series Cordless Screwdrivers Operation Manual

Installation Instructions

For Mini Split Units. Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System

F PRO. 12 Volt Electric Sprayer. Part #AS76 Copyright 2014 by Hydro-Force Rev. 1/14

Rechargeable Inflator

COILCARE PM. Installation Instructions and Operating Manual. CoilCare Series BioZone Scientific International, Inc.

Installation Instructions. Fog Lights. The lamps get very hot when they have been in use. Do not touch them as they may cause burns.

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

NUTONE RANGE HOOD NTM SERIES

Cleaner, Fresher Air in 24 Hours New Advanced Environmental Air Treatment System For PTAC & ETAC Units

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

LED LARGE WALL PACK (CUTOFF & STANDARD)

Low Profile Service Jack

AEROMOTIVE Part # Subaru Fuel Rails for Top Feed Injectors WRX & STI INSTALLATION INSTRUCTIONS

Submersible Pond Pump with UV 800 Gallons Per Hour

Laboratory Series. Ultraviolet Ozone Destruct System Installation, Operation and Maintenance Manual. One Source for All Your UV Needs!

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Transcription:

INSTALLATION INSTRUCTIONS Ultraviolet Single and Dual Germicidal Lamps 60 Hz Part Numbers: P103-UVLTT1LP1020A01, P103-UVLTT1LP3020A01, P103-UVLTT2LP1020A01, P103-UVLTT2LP3020A01 SAFETY CONSIDERATIONS Installation and servicing of air-conditioning equipment can be hazardous due to system pressure and electrical components. Only trained and qualified service personnel should install, repair, or service air-conditioning equipment. Untrained personnel can perform basic maintenance functions such as changing lamps. All other operations should be performed by trained service personnel. When working on airconditioning equipment, observe precautions in the literature, tags and labels attached to the unit or accessory, and other safety precautions that may apply. Follow all safety codes. Wear safety glasses and work gloves. Before installing accessory or performing maintenance or service on accessory, turn off main power switch to unit. Electrical shock can cause injury or death. There may be more than one disconnect switch. Never expose eyes or skin to ultraviolet light from any source. Lamp must be off before entering HVAC (heating, ventilation, and air conditioning) unit to perform maintenance or service. Personal injury may result. Do not touch lamp glass without gloves. Wipe lamp clean after handling. The lamp contains a small quantity of mercury. If a lamp breaks, clean area and dispose of lamp with care. GENERAL Totaline s ultraviolet (UV) germicidal lamps are designed to kill odor causing bacteria, viruses and mold that may develop in a HVAC unit. The UV Lamp system is designed to inhibit fungus and microbial growth when applied to the indoor coil/ drain pan area of a central cooling system. The lamps will also reduce airborne viruses and bacteria generated in the occupied space. The lamps should be mounted on a flat surface. Lamps are designed to operate for one year continuously before replacement is required. The UV Lamps are designed for indoor use only. On 2-lamp models, the 2 assemblies are connected by a flexible cord which allow the installer to separate the lamps from 4 to 18 inches. Each lamp kit includes cleaning kit and mounting screws. See Table 1 and Fig. 1 for physical data. NOTE: The health aspects associated with the use of this product and its ability to aid in disinfection of environmental air have not been investigated by UL (Underwriters Laboratories). INSTALLATION Location Make sure site can be supplied with the necessary power receptacle. Ensure that there is adequate clearance for service. The preferred location for installation is in the coil casing over the evaporator coil. The lamps should be placed above the coil, so the UV rays will cover the entire coil. See Fig. 2-4. On indoor coils 2 tons or smaller, the UV lamp should be installed in the connecting ductwork above the indoor coil and not in the coil casing itself. Do not install the UV lamps near duct board or plastic flex duct. Metal duct is recommended. Components contained in the current furnace and fan coil equipment are resistant to UV exposure. Color shift or chalking may occur without affecting structural properties. Table 1 Physical Data PART NUMBER P103-UVLTT1LP1020A01 P103-UVLTT2LP1020A01 P103-UVLTT1LP3020A01 P103-UVLTT2LP3020A01 Electrical Characteristics (V-PH-Hz) 115-1-60 115-1-60 208/230-1-60 208/230-1-60 Number of Lamps 1 2 1 2 Maximum Lamp Amperage Draw 0.6 Amps 1.1 Amps 0.3 Amps 0.6 Amps Average Power Consumption 27 Watts 53 Watts 27 Watts 53 Watts Unit Service Cord 6 foot cord with ground pin plug Average Lamp Life Approximately 1 Year or 9,000 Hours of Unit Runtime Initial UVC Output at 1 Meter (in µw/cm 2 and 70 Deg F) and 450 fpm Airflow 105 198 105 198 Lamp Length 19 in. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION 2004 7-04 LITERATURE NUMBER P103-11SI PRINTED IN U.S.A. CATALOG NUMBER 570-348

Fig. 1 UV Lamp (Two-Lamp Version Shown) STANDARD "A" COIL STANDARD "N" COIL FRONT OF COIL CASING SIDE VIEW WIDE "A" COIL HORIZONTAL "N" COIL Fig. 2 Typical Furnace Coil Mounting Locations 115-V Application 2

SMALL "A" COIL SMALL "N" COIL Fig. 3 Alternate Furnace Coil Mounting Locations 115-V Application DUAL LAMP APPLICATIONS SLOPED FAN COIL DUAL LAMP APPLICATIONS SINGLE LAMP APPLICATIONS "A" COIL IN FAN COIL SLOPED FAN COIL Fig. 4 Fan Coil Mounting Locations 208/230-V Application 3

Select a mounting location that prevents direct exposure to non-fiberglass media filters. A minimum distance of 6 feet is recommended (non-fiberglass media will break down from UV exposure). Mounting Perform the following procedure to mount the lamp. 1. Turn off all power to unit and install lockout tag. 2. Remove indoor coil casing door and inspect coil casing for proper location of UV lamp mounting holes. 3. Select location for lamp(s) that gives the most exposure to coil/drain pan. Light from the lamp should cover the coil and pan for maximum effectiveness (see Fig. 2-4). 4. Drill or cut a 7 / 8 -in. hole for each UV lamp into the coil casing, casing door or the connecting ductwork. 5. Separate lamp base, lamp/ballast assembly, and plastic cover. See Fig. 5. Securely mount UV lamp base assembly using screws provided. 6. Replace coil casing door and slide lamp/ballast assembly into the mounted base, making sure the locating stud and Molex connectors are aligned (see Fig. 5). 7. Install fastener screw to hold lamp/ballast to base. 8. Replace plastic cover(s) on UV lamp assembly base to complete the installation. 9. On furnace applications, use a 115-v power source other than the furnace motor circuit. On fan coil applications, use 208/230-v power source other than the fan coil motor circuit. Connect electrical cord to suitable electrical receptacle. OPERATION After power is supplied to lamp(s), make sure the LEDs behind the logo are illuminated. If not, verify the supply voltage. On 2-lamp models, both lamp/ballast assemblies need to be installed before lamps will illuminate. If at any time the LED (light-emitting diode) lights behind the logo are dim this is an indiction that one of the UV lamps is not working. Disconnect power and inspect for proper lamp operation. Lamp/Ballast assembly should be removed when mounted on indoor coil casing door, if door is to be removed for system maintenance. LAMP BASE LED LIGHTS LAMP/BALLAST ASSEMBLY NOTE: LED lights are not lamp change indicators. Lamps should be changed annually. Fig. 5 UV Lamp Assembly (Detail View) 4

Lamp Replacement Allow lamp to cool before opening UV lamp casing or HVAC unit cabinet. Failure to follow this caution will result in minor personal injury. The recommended life of the lamp assembly in this UV lamp product is 1 year of constant operation or a maximum of 9,000 hours of unit runtime. When replacement of lamp is needed, order proper lamp assembly (See Table 2) from a local dealer or distributor. To replace a lamp, perform the following procedure: 1. Disconnect power supply from UV lamp by unplugging the electrical cord. 2. Remove protective cover from UV lamp assembly. See Fig. 5. 3. Remove fastener screw(s) that holds lamp/ballast to base. 4. Gently pull lamp assembly from mounted base assembly. 5. Place old lamp assembly in a safe area before proceeding. Treat the disposal of these lamps as you would a standard fluorescent lamp. 6. Carefully slide new lamp/ballast assembly into base assembly until fully seated, retighten fastener screw(s) to hold new lamp in base. 7. Replace protective cover. 8. Reconnect unit power to UV lamp. 9. Observe that LEDs behind logo brightly illuminate and that the lamp(s) are operational. Table 2 Replacement Lamp Ordering Information QUANTITY LAMP VOLTAGE PART NUMBER 1 Lamp/Ballast Assembly 115-1-60 P103-UVLTTRPL1020-A01 1 Lamp/Ballast Assembly 208/230-1-60 P103-UVLTTRPL3020-A01 5

LIMITED WARRANTY FOR SERVICE OR REPAIR, FOLLOW THESE STEPS IN ORDER: FIRST: Contact the installer. You may find their name on the product or in your Homeowner s Packet. If the installer s name is not known, call your builder or home retailer if yours is a new residence. SECOND: Contact the nearest distributor. (See telephone yellow pages.) THIRD: Contact: CAC/BDP Consumer Relations P.O. Box 4808 Syracuse, New York 13221 Phone: 1-800-227-7437 Model No. Date of Installation Name of Owner Unit Serial No. Installed by Address of Installation ULTRAVIOLET LAMP (Model UVL) FIVE-YEAR LIMITED WARRANTY CAC/BDP (thereinafter referred to as Company ) warrants the unit Base and Power Cord against defects in material and workmanship for a period of Five years from the date of original installation. The Company s obligation for these parts shall be, at its sole option, to provide a new part without charge for the part itself or allow a credit in the amount of the then current factoryselling price of an equivalent part toward the purchase price of a new unit. 90-DAY LIMITED WARRANTY The Company warrants certain parts of this product to be free from defects in material and workmanship. If a defect is found in the Lamp (Bulb) or Ballast within 90 Days from date of original installation of product (whether or not actual use begins on that date) Company will provide a new or remanufactured part, at Company s sole option, to replace any defective part, without charge for the part itself. None of these warranties include labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts, or replacement parts, or new units. WARRANTY CONDITIONS: 1. Warranties apply only to products in their original installation location. 2. Installation, use, care, and maintenance must be normal and in accordance with instructions contained in the unit literature and Company s service information. 3. Defective parts must be returned to the distributor through a registered servicing dealer for credit. 4. All work shall be performed during normal working hours. LIMITATION OF WARRANTIES ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE) ARE HEREBY LIMITED IN DURATION TO ONE YEAR. SOME STATES TO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESS WARRAN- TIES ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER. COMPANY WILL NOT BE REPONSIBLE FOR: 1. Normal maintenance as outlined in the installation and servicing instructions or Owner s Manual, including filter cleaning and/or replacement and lubrication. 2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation. 3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or damages due to the inadequacy or interruption of electrical service. 4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other conditions beyond the control of Company. 5. Parts not supplied or designated by Company, or damages resulting from their use. 6. Company products installed outside the continental U.S.A., Alaska, Hawaii, and Canada. 7. Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever, including additional or unusual use of supplemental electric heat. 8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential damages, so the above limitation may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. 6

Your Assurance of Quality ALL Totaline products are backed with a warranty by Carrier Corporation, the world s largest manufacturer of air conditioning, heating, and refrigeration products. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. REPLACEMENT COMPONENTS DIVISION CARRIER CORPORATION 2004 7-04 LITERATURE NUMBER P103-11SI PRINTED IN U.S.A. CATALOG NO. 570-348