PREVIEW ONLY. Course 106 INSTRUCTOR GUIDE. HVAC Systems Introduction and Overview. Module 1: Overview of Rail Car HVAC and General Safety Procedures

Similar documents
Instructor Guide. 215: Elevator: Mechanical Drive Systems Module 3: Gearless Drive Systems

Instructor Guide. 215: Elevator: Mechanical Drive Systems Module 4: Hydraulic Drive Systems

Elevator Hydraulic Machine Room Instructor s Guide

Circuit Concepts (Residential)

JEFFERSON COLLEGE COURSE SYLLABUS HRA101 ELECTRICITY FOR HVAC. 5 Credit Hours. Prepared by: William Kaune. Revised Date: March 17, 2014

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

LABORATORY SAFETY SERIES: Electrical Safety

BELT-DRIVEN ALTERNATORS

Electrical Controls. Syllabus

Permanent Magnet DC Motor Operating as a Generator

EE042: Practical Power System Protection for Engineers & Technicians

ELECTRICAL TECHNOLOGY 3 March 2008

3 Phase Voltage Imbalance

Phase 1 Workshop Home Study Guide

"Motors, Power, and Data Loggers Greg Jourdan-Wenatchee Valley College Tuesday, May 8, Sessions Session 1-8:30-9:25 a.m. Motors 101 Session

Introduction and Overview to Friction Brakes. Course 105 PREVIEW ONLY PARTICIPANT GUIDE

Industrial Substation Maintenance April $4,250 Abu Dhabi. UAE

MODULE 6 Lower Anchors & Tethers for CHildren

HAZWOPER Technician Level Course Outline

IAE-101: Electrical Fundamentals for Non-Electrical Personnel

The Starter motor. Student booklet

MAGNETIC MOTOR STARTERS

Electrical Equipment and Terminology

Permanent Magnet DC Motor

Electric Motor Controls BOMA Pre-Quiz

Short Term Course On Hydropower Development Engineering (Electrical) for Teachers of Polytechnics in Uttarakhand L33-2

Why is the Breaker Tripping?

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

Training Syllabus to Instruct Bus Technicians on Hybrid Drive Systems Operations and Maintenance

Inspection and Maintenance of Friction Brakes. Course 205 PREVIEW ONLY PARTICIPANT GUIDE

Application Note : Comparative Motor Technologies

Overcurrent protection

MODULE 4 Seat Belt Systems

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

SEW Brakes. Service and Maintenance

Course Syllabus

SECTION 4 ELECTRIC MOTORS UNIT 20 TROUBLESHOOTING ELECTRIC MOTORS UNIT OBJECTIVES 3/21/2012

SECTION 4 ELECTRIC MOTORS UNIT 20 TROUBLESHOOTING ELECTRIC MOTORS

Ex. 1-1 Nacelle Familiarization and Safety Discussion

HELPING YOU TEACH TECHNOLOGY

UNIT 2. INTRODUCTION TO DC GENERATOR (Part 1) OBJECTIVES. General Objective

Chapter 7: DC Motors and Transmissions. 7.1: Basic Definitions and Concepts

EVENING PROGRAM DESCRIPTIONS. California State Smog Repair Technician

Technical Information and Diagnostic Guide

Exercise 1-5. Current Protection Devices EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Circuit breakers

ECET 211 Electric Machines & Controls Lecture 5-4 Electric Motors. Lecture 5-4 Electric Motors

Variable Frequency Drive Basics

Advanced RiderCourse SportBike Techniques Frequently Asked Questions. 1. What is the MSF Advanced RiderCourse SportBike Techniques (ARC-ST) course?

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

School Driver Trainer Inservice

C.E. Niehoff & Co. N1601, N1602, N1603, and N1604 Alternator Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Electrical Equipment and Safety: Operation, Control, Maintenance and Troubleshooting

MOTOR INSTALLATION. Knowledge of proper installation techniques is vital to the effective operation of a motor

C802/C802D/C802TD/C820 Alternators Troubleshooting Guide

C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide

Required Textbook and Materials 1. Texas Commercial Vehicle Drivers Handbook 2. Handout literature

Training Title GAS TURBINE AND COMPRESSOR OPERATION, MAINTENANCE AND TROUBLESHOOTING

ECM. marsdelivers.com. Delivering Confidence 7/15

Understanding the Battery

Higher National Unit Specification. General information for centres. Electrical Motors and Motor Starting. Unit code: DV9M 34

SECTION MOTOR CONTROL

Lesson Plan: Electricity and Magnetism (~100 minutes)

Activity 8: Solar-Electric System Puzzle

Lesson Plan. Time This lesson should take approximately 180 minutes (introduction 45 minutes, presentation 90 minutes, and quiz 45 minutes).

Training Proposal for Network Energy Product Technology Training Project

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.

School of Technology, Energy & Apprenticeship. Advanced Power Engineering Program. Course Outline fall 2014

SUBSTATION OPERATION. Maintenance Techniques. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

ECM. marsdelivers.com 7/15

Vibration Diagnostic Software. Proven Automated Diagnostic Technology for Machinery Condition Assessment

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

PI Electrical Equipment - Course PI 30.2 MOTORS

"ELECTRICAL SAFETY IN THE LABORATORY"

N1233 Series Troubleshooting Guide for N Alternator

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

Applications of Electrical Machines

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

EE064D: Circuit Breakers & Switchgears: Design, Testing, Commissioning, Maintenance, Repair & Troubleshooting

SAMPLE. Engine Driven Welding Power Sources. Topic 5. Welding Process Training Series

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Full file at

SAFETY TECHNIQUES FOR SPECIAL NEEDS BUS DRIVERS

Installation and Construction Notes for EVSE4

High Voltage Electrical Maintenance Training

A/C Generator Systems

GATES MAINTENANCE TRAINING Preventive Maintenance Training Course

PAGE Both power cords must be connected & powered to operate the E-TES 120.

DIESEL ENGINES MAINTENANCE PONSIBILIT Training Duration 05 days

EST Electrical Service Technician Answer Schedule

ELECTRICAL SYSTEM RP-7

ECEg439:-Electrical Machine II

General elearning Course Catalog

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Your web browser (Safari 7) is out of date. For more security, comfort and. the best experience on this site: Update your browser Ignore

EDITOR'S NOTE: This article replaces "Use PGM FI Data List to Help Troubleshoot Inoperative A/C," issued in June 2012.

Welcome VA School Bus Technicians From

High Frequency SineWave Guardian TM

BASIC PUMP TECHNOLOGY

INTRODUCTION Principle

Transcription:

Course 106 HVAC Systems Introduction and Overview Module 1: Overview of Rail Car HVAC and General Safety Procedures INSTRUCTOR GUIDE

Table of Contents CHECKLIST FOR INSTRUCTION... 3 SUPPLIES, AUDIO-VISUAL EQUIPMENT, INTERNET ACCESS... 3 BEST PRACTICES FOR DELIVERING TRAINING... 4 OVERVIEW TO COURSE 206... 5 MATERIALS FOR INSTRUCTION... 5 COURSE 206 ASSESSMENTS... 5 OVERVIEW TO MODULE 1... 6 Videos, Handouts, Job Aids, Take-aways... 6 Outline of PowerPoint Presentation... 6 Learning Objectives for Module 1... 6 Overview... 7 Motors in HVAC... 11 Phases of Power... 13 Major Components of DC and AC Motors... 17 Thermal Overload Relay Protection... 24 HVAC Motor Preventive Maintenance and Inspection... 29 Field Trip... 39 Summary and Quiz... 40 Page 2

Checklist for Instruction Confirm the training dates, location, and number of participants. Ensure you have all materials listed in the section Materials for Instruction. Ensure you have all that is listed in the section Supplies, Audio-Visual Equipment, Internet Access. Read and study the Instructor Guide, PowerPoint presentation, and any State or local documentation pertaining to the local environment. If using case studies, review ahead of time and select the most appropriate cases studies for your audience. Familiarize yourself with the Participant Guide or coursebook. Collaborate with local host/coordinator to determine who will print the following (available on website): Certification of completion for each participant. Supplies, Audio-Visual Equipment, Internet Access The following is important for the adequate delivery of this course: LCD projector compatible with a notebook computer and cables for proper connection Computer with software to run Microsoft PowerPoint Electronic remote device to advance slides in PowerPoint presentation, if available Projection screen (at least 6 x 6 ) Pointer (preferably laser type) Twenty-foot or longer extension cord Dry erase board with dry erase markers and eraser, if available Flip chart with markers Supplies such as pencils, note pads, markers, highlighters. Access to lab, rail car shop, rail car for hands-on lessons You may need Internet access. All equipment should be placed and tested in the room. The instructor should check at least one hour prior to the first day of the course. Page 3

Overview to Module 1 Duration of this module: 185 minutes (3 hours including field trip) PowerPoint slides: 27 This module has a quiz. Videos, Handouts, Job Aids, Take-aways Links to one (1) Vimeo video is made available to enhance participants learning: Video Rail HVAC Overview The Instructor should bring the following materials/equipment if applicable: Property-specific Safety Data Sheets. Property-specific Personal Protection Equipment Property-specific Lockout/Tagout Kits Property-specific job cards Outline of PowerPoint Presentation Topic Title Slides Duration (Minutes) Overview 1-4 5 5-6 10 7-9 10 10-14 25 15-18 15 19-24 45 Field Trip 25 60 Summary and Quiz 26-27 15 Learning Objectives for Module 1 185 minutes (3 hours including Field Trip) Following the completion of this module, the rail car technician should be able to: Demonstrate knowledge of Clean Air Act of 1990, EPA 608 Certification, Refrigerant Hazards and Proper Handling Techniques Explain types and use of Personal Protective Equipment (PPE) when dealing with HVAC systems List safety rules related to HVAC maintenance Page 6

Motors in HVAC Slide 5 Rail Car HVAC Motors Evaporator Blower Motor Thermo King Evaporator Blower Motor Electric Rail Car HVAC Motors Compressor Motor Assembly Thermo King Condenser Blower Motor INSTRUCTIONAL ACTIVITY: Overview of HVAC Motors in transit rail TIME: 5 minutes INSTRUCTION METHOD: Lecture SAY: Electric motors are used to turn the prime movers of air, water, and refrigerant, which are the fans, pumps, and compressors. These motors provide the speed, torque, and horsepower necessary to operate the application. The motor changes one form of energy (electrical) to rotational or linear motion (mechanical). AC and DC motors are the two major types in use today that are related to the industrial HVAC applications. In rail car HVAC units, AC motors are generally used in newer equipment. Some systems have retrofitted their motors from DC to AC in recent years. To understand the differences of AC and DC motors, it is important to first review different phases of power. ONLY 5 PARTICIPANT GUIDE (COURSEBOOK) PAGE REFERENCE: ADVANCE SLIDE PREVIEW Page 11

Major Components of DC and AC Motors Slide 10 Components of DC Motors Armature Field Winding Commutator Brushes INSTRUCTIONAL ACTIVITY: Explain definition and components of a DC motor TIME: 5 minutes INSTRUCTION METHOD: Lecture SAY: A DC motor is any of a class of electrical machines that converts direct current electrical power into mechanical power. The two major components of a DC motor are the armature (top figure) and field winding. The armature is the rotating part that is physically connected to the shaft and develops magnetic flux around its windings. The field winding is the part of the stationary frame and provides the flux necessary to interact with the armature flux to produce rotation. The commutator (Bottom right figure) acts as an electrical switch and always ensures that a repelling force is present between the armature and field flux circuits. This repelling force against the field winding flux causes rotation of the armature. Brushes (Bottom left figure) are the devices that physically connect the voltage supply to the armature circuit. Brushes are constructed of carbon material and require routine maintenance or replacement to reduce arcing at the commutator segments. For maintenance purposes, this is the biggest difference between DC motors and AC ones, which do not contain brushes. 10 Page 17

Thermal Overload Relay Protection Slide 15 Thermal Overload Relay Protection The compressors, condenser fan motors, and evaporator fan motors are protected by external thermal overload relays, which are combined with circuit breakers. They are protective devices designed to cut power if the motor draws too much current for an extended period of time. To accomplish this, thermal overload relays contain a normally closed (NC) relay. When excessive current flows through the motor circuit, the relay opens due to increased motor temperature, relay temperature, or sensed overload current, depending on the relay type. INSTRUCTIONAL ACTIVITY: Explain definition and function of Thermal Overload Relay Protection TIME: 2 minutes INSTRUCTION METHOD: Lecture SAY: Thermal overload relays are similar to circuit breakers in construction and use, but most circuit breakers differ in that they interrupt the circuit if overload occurs even for an instant. Thermal overload relays are conversely designed to measure a motor's heating profile; therefore, overload must occur for an extended period before the circuit is interrupted. ONLY PARTICIPANT GUIDE (COURSEBOOK) PAGE REFERENCE: 15 Other Tools/Media/Materials: Bring a property specific Thermal Overload Relay Protection and explain its mechanism. ADVANCE SLIDE PREVIEW Page 24

Slide 17 Thermal Overload Relay Protection INSTRUCTIONAL ACTIVITY: Present content with video TIME: 1 minute INSTRUCTION METHOD: Multimedia SAY: Let s take a look at this short video on how a bimetallic switch works. This video illustrates the use of bimetallic switch, with the bimetallic strip highlighted in the middle of the video. When the flame is applied to the switch, the strip bends and the switch opens. Note that when the strip cools, the strip returns to its original position and the switch closes. Other Tools/Media/Materials: Play Youtube video ADVANCE SLIDE PREVIEW ONLY 17 Page 27

Slide 20 HVAC Motor Preventive Maintenance and Inspection Basic Guidelines to Motor Maintenance (2) Motor mount inspection Motor temperature control Record keeping INSTRUCTIONAL ACTIVITY: Explain Motor PM and Inspection Procedures TIME: 5 minutes INSTRUCTION METHOD: Lecture with hands-on demonstration in lab or during field trip SAY: Motor mount inspection. Check mounting bolts, steel base plates for possible warping. Annually, perform vibration-analysis tests. Excessive vibration may be hard to detect by hand, but it could be enough to shorten motor life significantly. It can cause bearing failure, metal fatigue of parts, or failure of windings. The cause of vibration is usually mechanical in nature, such as excessive belt tension, defective sleeve or ball bearings, misalignment, or improper balance. The most common cause is the unbalance of a rotating member (the motor rotor, rotating load, or other drive train component). Electrical problems also can cause vibration. Simple testing of the motor is done by uncoupling the load and then running the motor and listening to the motor noise and feeling for the vibration. Motor temperature control. Restricted ventilation will cause a motor to operate at a higher than desired temperature. Excessive ambient temperatures will shorten motor life. 20 Page 31

Slide 21 Motor Inspection and Maintenance Classroom Activity Work in pairs or small groups. Based on the OEM manual or agency operating procedures, what are your agency s procedures for HVAC motor inspection and maintenance activities and schedule? You have 10 minutes INSTRUCTIONAL EVENTS: Elicit performance TIME: 12 minutes DO: Have participants work with a partner to work on Classroom Activity 1 in their coursebook giving them 10 minutes to complete this activity. Once completed ask each group to volunteer their answers. PARTICIPANT GUIDE (COURSEBOOK) PAGE REFERENCE: ADVANCE SLIDE 21 Page 33

Testing Current Draw: To test the current, or amperage, draw, the motor must be operated. The most convenient way to check the amperage is to use a clamp-on ammeter. With the motor running under a normal load, check the amperage draw of each power line, or leg. Since the current draw may vary slightly over time, you may want to take several readings and then average the data. To obtain an average, record several amp readings at one-minute intervals. Next, add the amp readings together and divide that number by the number of readings taken. After testing each leg, compare the amperage draw data to the amperage information on the nameplate or in the operating maintenance logs. Testing Continuity Using Meters: Using a multimeter set for resistance checking is a convenient way to check continuity. Remember that any time a multimeter is used for continuity testing the device being tested must be deenergized. To test a motor for continuity, first isolate, or disconnect, it from the circuit. Then use the multimeter to check the resistance between phases. Most transit agencies use multimeters for this test rather than the test lamps. Testing for Shorts and Grounds Using Meters: Use a Megohmmeter or a multimeter to test for a grounded motor. Set the meter for resistance testing, and connect one lead to the motor housing, or frame. Next connect the other lead to a winding. If the winding is grounded, the meter will indicate a low resistance. Testing Phase Rotation: Before the initial start-up of a large motor, make sure the motor is turning in the proper direction by simple observation or an air flow check. If the meter indicates that the motor is turning in the wrong direction, check to make sure that all connected elements, such as transformers and branch circuits, are connected correctly. If all connections are correct, check the individual phases of the motor. PARTICIPANT GUIDE (COURSEBOOK) PAGE REFERENCE: ADVANCE SLIDE Page 37

Field Trip Slide 25 Time for a Field Trip INSTRUCTIONAL EVENTS: Hands-on Learning TIME: 60 minutes DO: Have the participants make a list of the components that they d like to see in the field. Ask one participant to scribe on a whiteboard/flip chart. Take the group into the field and ask them to explain what they see helping with identification/explanation as needed. ADVANCE SLIDE Page 39