ACO Water Management: Civils + Infrastructure

Similar documents
ACO Water Management: Urban + Landscape Civils + Infrastructure

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure

Uniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain

ACO Water Management: Civils + Infrastructure

ACO Drain. For more information on ACO Drain visit ACO KerbDrain 280 Splay

ACO Qmax Unit size

ACO Water Management: Civils + Infrastructure

ACO Water Management: Civils + Infrastructure

CI/SfB (52.5) May 2003 Uniclass L L2123. ACO KerbDrain The cost effective approach to kerb drainage systems

h2* linear fall up to 20 m, stepped fall, without fall Loading classes: A 15, B 125, C 250 to EN 1433

LINEAR DRAINAGE. 50 years serving the construction industry

EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data

MEADRAIN. Traffic System MEAKERB. Technical Data. Material properties. Description and sizes. Channel body. Top section

Domestic Traditional Pits DOMESTIC TRADITONAL PITS

Reinforced edge channels KE-100

ACO Polycrete Pty Ltd ACO A Global Company

ACO Modular. ACO Product catalogue. Modular Stainless Steel Channel Drainage System. Modular 20. Modular 125. Modular 200. Floor Drainage systems

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC)

kerb and gully range fast delivery on ex-stock items to any postcode nationwide

LANDSCAPING AQUA SPORT RECYFIX PLUS ROBUST, RECYCLED AND EASY TO INSTALL.

Covers and Frames Ductile Iron Covers and Frames Gully Grates D Surface Boxes 270 Steel Covers and Frames

A monolithic drainage system designed to accept and convey large volumes of rainwater. Product Attributes

Infrastructure & Power. FP M c Cann. Tel: +44(0) Fax: +44(0)

The Pump Matic Range

PARKING type SC. The polyester concrete drainage channel with 2mm protective edge profi le IMC SC EN

ACO Modular Channel Introduction

TECHNICAL type SE. The polyester concrete drainage channel with 4mm protective edge profi le IMC SE EN

Heavy Duty Commercial Pits

CATALOGUE SEWAGE MANHOLES

SOLUTIONS WE OFFER YOU... ulmaarchitectural.com. ULMA Architectural Solutions -

POWER & INFRASTRUCTURE SOLUTIONS

fit! Perfect CLARK-DRAIN CD 300SR CD 300 CLKS 422 THE NEW Polypropylene Cover and Frame! NEW Polypropylene Cover and Frame! THE UK S NUMBER ONE

STORA-DRAIN PARKING POLYESTER CONCRETE DRAINAGE CHANNEL GALVANIZED PROFILE

Drainage and building solutions for Wildlife Conservation ACO Wildlife Systems

Introduction. Eccles (UK Foundries FE) Ltd has a group experience of some 77 years in the manhole cover industry.

MEA RIN Plus 100 and Expert 100. Technical data sheet. Material properties. Description and sizes. Edge protection MEARIN Plus

Stability and Diversity

Aim higher. Soil & Waste System

MUNICIPAL WATER PRODUCTS OVERVIEW

ACO Tiefbau. Line drainage

Complete Drainage Channels with Galvanized Slotted Grating. Product Dimension Product # lbs/ Description l x h [in] unit

SpeedStopper original rubber speed bumps. BART rubber heavy duty speed bumps. SMART rubber bumps extra wide. Modular rubber speed bumps

GB-250. Submittal Specifications Installation Application Specific Details

Road + Civils AG.UK.COM

JCB ATTACHMENTS FOR MINI AND MIDI EXCAVATORS A class-leading range of attachments suitable for mini and midi excavators.

Power Distribution Enclosures. Pillar shells and in-ground feeder pillars

MULTIV+ SYSTEM APPLICATIONS: SYSTEM SUITABLE FOR PEDESTRIAN AND SHOPPING AREAS, AS WELL AS PARKING AREAS FOR ALL TYPES OF VEHICLES.

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

Recessed Access Covers ACCESS COVERS & DRAINAGE SYSTEMS

GRP Composite Trench Covers Technical Guide

ACO product catalogue. ACO Industrial Drainage

Industrial Horizontal Bearings IH and HD Series

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

TRADE PRICE LIST - 1st March Below Ground & Civils Systems

TRADE PRICE LIST - 1st March Below Ground & Civils Systems

Commercial Sized Drainage

BL PIEZO ELECTRIC SENSOR

Hynds Telco and Electrical Pit System

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

Design Stress = 8 Mpa

CLARK-DRAIN AT A GLANCE

FASERFIX STANDARD. Solid drainage channel for easy self-installation, predominantly in private areas.

Home About Us Products & Services Search Contact Us

ATLANTIC PLASTICS is a company of. UPE Multi Diameter Wide tolerance Couplings and Flange Adaptors

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

THE PROTEAN AND POC-MAST DESIGN

BRIDGEMONT BMS. The new force in weighbridge design

Septic tanks A septic tank from Ri-Industries offers a number of benefits: Industries

Why Choose Rexnord? 866-REXNORD/ (Within the U.S.) (Outside the U.S.)

4.5 COMPOSITE STEEL AND CONCRETE

Septic Tank. Installation Guidelines

specified to fit your environment

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

MISSION STATEMENT THE ENVIRONMENT

ACO slot and box channels

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

SUMMER, ALL-SEASON AND WINTER TYRES 2017/18

Cable, Utilities and Various Network Solutions. Access Covers

Technical Bulletin. Terrain FUZE HDPE Thermal Expansion L = L T. Bulletin P1

Flexible Couplings & Saddles

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Concrete Pipes 62 Traditional Manholes Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69

Elastomeric Bearings & Industrial Products. Elastomeric Bearings & Industrial Products. EA Bearings. EA Bearings. EA Series Standard Bearings

Classes. Class A 15. Class B 125 CLASS C 250. Class D 400. Class E 600. Class F 900 A 15 B 125 C 250 D 400 E 600 F 900

BLYTH RANGE. Unique features of the Blyth Mk 2 range. tel:

AUTOMATIC CONTROL VALVES BY RAPHAEL

Industries. Septic Tanks

SUMMER, ALL-SEASON AND WINTER TYRES 2018

British Standard Underground Hydrant Range

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

INSTALLATION GUIDELINES

GB-35. Submittal Specifications Installation Application Specific Details. PART #: XX DWG BY: C. O'Boyle DATE: 10/08/2015 REV: 0 / /201_ ECO:

Transportation Engineering II UNIT - I

Tecstrut Channel Suspension & Framing System

Low Impact Light Rail Update

MEARIN 100. Drainage Systems MEARIN

Underground Drainage Manhole & Inspection Chambers Prefabricated Polyethylene (PE)

An innovative solution for water and sewer installation AXIS. Guided Boring System

sump units end caps and connectors 2018 PRICE LIST VIBRO-BASE / EVO SERIES R SERIES

Transcription:

ACO Water Management: Civils + Infrastructure Uniclass L223 + L735 CI/SfB (52.5) EPIC J343 ACO MultiDrain PPD ACO MultiDrain PPD channel drainage system Specification manual

ACO MultiDrain PPD Introduction to the ACO Group Throughout the world, the ACO brand is recognised as a leading supplier in the design, development and manufacture of surface water drainage systems. An extensive portfolio offers the market quality solutions for every application, including internal and building drainage, landscaping, sport facilities, retail, distribution centres, highways and airports as well as solutions for environmentally sensitive projects. The ACO Group has been manufacturing and selling market leading drainage systems for over 40 years. During this time the group has made extensive investment in global research and development and manufactures products world wide at 3 modern environmentallysensitive production sites. Designed with applications in mind, ACO Group surface water drainage systems are manufactured using a diverse range of materials including: Vienite, ACO s high strength recycled material Polymer concrete Steel Plastic Ductile iron The ACO group / www.aco.com

Contents Introduction to ACO MultiDrain PPD 4 ACO MultiDrain PPD features overview 6 Components of the ACO MultiDrain PPD system layout 8 ACO MultiDrain PPD product selector ACO MultiDrain MPPD ACO MultiDrain MPPD channels with galvanised edge rails 2 ACO MultiDrain MPPD accessories 2 ACO MultiDrain MPPD traditional gratings and Brickslot tops 4 ACO MultiDrain MPPD hydraulic performance tables 6 ACO MultiDrain M50PPD ACO MultiDrain M50PPD channels with galvanised edge rails 8 ACO MultiDrain M50PPD accessories 8 ACO MultiDrain M50PPD traditional gratings and Brickslot tops 20 ACO MultiDrain M50PPD hydraulic performance tables 22 ACO MultiDrain M200PPD ACO MultiDrain M200PPD channels with galvanised edge rails 24 ACO MultiDrain M200PPD accessories 24 ACO MultiDrain M200PPD traditional gratings 26 ACO MultiDrain M200PPD hydraulic performance tables 27 ACO Universal Gully 28 Designing a drainage system 29 Installation detail 30 Chemical resistance chart 33 Frequently asked questions 34 Model specification clause and declaration of conformity 35 3

ACO MultiDrain PPD Introduction to ACO MultiDrain PPD The new ACO MultiDrain PPD channel and grating system provides versatile and efficient linear drainage for infrastructure and hard landscaping projects. What is ACO MultiDrain PPD? ACO MultiDrain PPD m constant depth channel elements are available in 3 widths: mm, 50mm and 200mm. This gives the designer the means to select the optimum channel size and hydraulic performance required, minimising the number of outlets and keeping installation costs as low as possible. An extensive choice of grating styles, materials and load classes is available fitted with the ACO Drainlock fastening system, which provides simple and quick installation yet prevents traffic displacing the gratings. If there is a risk of unwanted grating removal or theft then security locking systems are available. Where slot drainage is preferred ACO Brickslot tops are available for the mm and 50mm wide channels, providing discreet slot drainage in either block paving or natural stone surfaces. The offset drainage slot also enables ACO Brickslot to be used right up to building façades or for threshold drainage. 4 Why choose the ACO MultiDrain PPD system? The system meets the highest standards for performance and quality, being fully compliant with and independently certified to BS EN 433:2002 for applications ranging from A 5 up to and including D 400*, ideal for pedestrians, cars, service vehicles or HGV traffic. The constant depth m recycled polypropylene channels with protective galvanised steel edge rails are extremely robust and durable yet all weigh under 5kg thanks to ACO s unique HexTechnology channel structure. ACO MultiDrain PPD has the performance to withstand the rigours of installation and provide long service life. Installation and maintenance costs are kept to a minimum with each channel packed with labour saving features, such as clip together end details for rapid channel connection and alignment, knockout panels for outlet pipe work, and the V shaped channel bore that promotes self cleansing. Guidance on preparation, installation and maintenance of this system is given in the ACO MultiDrain PPD installation manual or visit www.aco.co.uk.

Typical applications The ACO MultiDrain PPD system can provide a channel drainage solution for many applications by selecting the appropriate channel width, depth and grating type. Typical applications include: Commercial developments Residential developments Private and public parking areas Landscaping Light industrial units Pedestrian precincts Schools Sports and leisure facilities Discreet slot drainage Threshold drainage Cable ducting 5 Key features and benefits Range of sizes and depths suits many drainage designs Strong, robust channel unit Galvanised edge rail for improved installed strength % recyclable Extensive choice of gratings and accessories Easily cut to mm lengths Unique ACO Drainlock grating fixing improves hydraulic capacity CE marked and fully certified to BS EN 433:2002 Load Class D 400* Efficient surface water drainage for a wide variety of applications Channel design improves flow velocity, promotes self cleansing Lightweight design is simple and fast to install i If you need help with specification, design or installation, or just wish to learn more about this and other Surface Water Management products from ACO, contact our free, no obligation ACO Water Management Design Services Team who can provide advice and dedicated design support for your project 0462 86666 or visit www.aco.co.uk. *Not suitable for carriageways of public roads or motorways

ACO MultiDrain PPD ACO MULTIDRAIN PPD FEATURES OVERVIEW ACO MultiDrain PPD gratings are fitted with the ACO Drainlock fastening system for quick installation Security locking option available to restrict unwanted grating removal Anti shunt feature holds grating securely in place Durable galvanised steel edge rail protects channel from traffic damage Channels clip together easily Sealant groove for simple watertight installations 6 V shaped channel bore improves speed of water flow and promotes self cleansing Environmentally friendly product manufactured from recycled polypropylene and % recyclable Constant depth channels are provided with a 90 channel connection

High quality channel CE marked and certified to BS EN 433:2002 Load Class D 400* (see table below) Channels available in mm, 50mm and 200mm widths, enabling efficient hydraulic drainage design A wide choice of gratings is available in various materials and designs Textured external surfaces and anchors key the product securely into concrete surround Vertical outlet for connection to sump units or pipework 0.5m cutting guide enables simple on site modification to create shorter channel lengths 7 HexTechnology : provides a rigid channel body during and after installation LOAD CLASSES A 5 Pedestrian, cycleways and domestic drives. B 25 C 250 D 400 Pedestrian precincts, light vehicles, private car parks and drives. Parking areas, service stations (cars) and slowmoving light commercial vehicles. Parking areas for all vehicle types*. *Not suitable for carriageways of public roads or motorways

ACO MultiDrain PPD Components of the ACO MultiDrain PPD system layout The layout diagram below illustrates the channels and accessories available within the ACO MultiDrain PPD range. Numerical product codes are provided after the product description for quick reference e.g. Closing end cap 85. ACO MultiDrain MPPD shallow constant depth components ACO MultiDrain MPPD constant depth components Closing end cap 85 Closing end cap 86 2 Channels 075 channel 44 0V channel 45 2 Channel 0.0J channel 40 2 2 3 Outlet connectors Ømm connector 285 Ø60mm connector 286 3 4 Sump unit* 385 5 Foul air traps Ømm foul air trap 9 Ø60mm foul air trap 92 8 5 4 5 i Guidance for using the ACO MultiDrain PPD parts tables The ACO MultiDrain PPD parts tables are shown on the forthcoming pages. The product information is split down by channel widths. This enables quick and simple product identification and selection. All channels within the ACO MultiDrain PPD range are constant depth units. * Sump unit connects to channel via Ø60mm outlet connector which is provided as part of the sump assembly. ** Sump unit connects to channel via Ø200mm outlet connector which is provided as part of the sump assembly

ACO MultiDrain M50PPD constant depth components ACO MultiDrain M200PPD constant depth components Closing end cap 93 Closing end cap 98 2 Channel 0.0J channel 5 2 Channel 0.0J channel 58 2 2 3 Outlet connector Ø60mm connector 288 3 3 Outlet connector Ø200mm connector 289 3 4 Sump unit* 386 4 Sump unit** 387 5 Foul air traps Ømm foul air trap 9 Ø60mm foul air trap 92 5 Foul air trap Ø60mm foul air trap 92 5 4 5 4 5 9 6 ACO Universal Gully Gully assembly and bucket 3360 Gully assembly no bucket 33602 For use on all ACO MultiDrain PPD systems.

ACO MultiDrain PPD ACO MultiDrain PPD product selector Making the right product selection ACO MultiDrain PPD is available in three width and depth configurations with two additional shallow channel options on the mm wide system. In order to summarise the options available, the product selector below displays key features for each of the system widths. Once product selection has been made based on the features required, the table will direct you to the appropriate page. CHANNELS WITH TRADITIONAL GRATINGS ACO MULTIDRAIN MPPD ACO MULTIDRAIN M50PPD ACO MULTIDRAIN M200PPD KEY FEATURES mm 50mm 200mm CHANNEL WIDTH CATCHMENT AREA 252m 2* 67m 2* 440m 2* SHALLOW CONSTANT DEPTH CHANNELS CONSTANT DEPTH CHANNELS MAXIMUM LOAD CLASS GRATING CHOICE BRICKSLOT TOP GO TO PAGE GO TO PAGE 7 GO TO PAGE 23 KEY CATCHMENT AREA AVAILABILITY *EXAMPLE RUN BASED ON 50m LENGTH TO OUTLET AVAILABLE NOT AVAILABLE GRATING CHOICE LOAD CLASS D 400 LIMITED SMALL WIDE PARKING AREAS FOR ALL VEHICLE TYPES. NOT SUITABLE FOR CARRIAGEWAYS OF PUBLIC ROADS OR MOTORWAYS.

ACO MultiDrain MPPD MPPD ACO MULTIDRAIN MPPD mm The ACO MultiDrain MPPD channels are available in shallow and constant depths and have integral galvanised steel protective edge rails to give the channel optimum protection from vehicular traffic. The channels are manufactured from recycled polypropylene, a robust lightweight material. For the ACO MultiDrain MPPD range of gratings to suit these channels please refer to pages 4 and 5. 252m 2* Channel width mm Catchment area Shallow constant depth channels Constant depth channels Load Class D 400 i To compare the different features of the ACO MultiDrain PPD range, use the product selector on page. Grating choice WIDE Brickslot top available *Example run based on 50m length to outlet

ACO MultiDrain PPD ACO MultiDrain MPPD Shallow constant depth channels with galvanised edge rails 44 MPPD No. 075* Length 0 42 overall 75 56 2.63 45 MPPD No. 0* 0 42 75 2.90 42mm 0mm mm Constant depth channel with galvanised steel edge rails 40 MPPD No. 0.0J* Length 0 42 overall 50 25 3.50 42mm 0mm mm 50mm 25mm 75mm 5675mm 30mm 76mm MPPD 075 0 m shallow depth channel 30mm 76mm MPPD m constant depth channel 2 Universal closing end caps 85 MPPD shallow channel universal closing end cap Length 38 overall 5 0. 86 MPPD universal closing end cap 38 50 0. mm 38mm 5mm mm 38mm 50mm MPPD shallow channel universal closing end cap MPPD universal closing end cap J Indicates side knockout for 90 channel connection. Knockout on both sides of the channel. * Indicates channels supplied with vertical outlet knockout for use with Ømm and Ø60mm outlet connectors. Outlet connectors supplied separately, see opposite page for details. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain MPPD Outlet connectors 285 Ømm vertical outlet connector Length Ø overall 60 0. 286 Ø60mm vertical outlet connector Ø60 80 0. 82mm 8mm 60mm 60mm 3mm 80mm 80mm 80mm Ømm MPPD Ømm vertical outlet connector Max flow from channel 075 = 4.8 l/s 0 = 5.5 l/s 0.0 = 7. l/s Ø60mm MPPD Ø60mm vertical outlet connector Max flow from channel 075 = 6. l/s 0 = 7. l/s 0.0 = 9.2 l/s MPPD sump unit 385 Black plastic sump unit with plastic silt bucket and Ø60mm outlet connector Length 350 Ø2 overall 5 3.00 MPPD Standard sump outlets Grating level = Ømm outlet Ø68mm 2 3 4 = Ø60mm outlet = including channel: 075 = 287mm (6. l/s) 0 = 32mm (7. l/s) 0.0 = 362mm (9.2 l/s) = : 075 = 557mm (6. l/s) 0 = 582mm (7. l/s) 0.0 = 632mm (9.2 l/s) Ømm Ømm 5mm 3 Foul air traps 9 Ømm foul air trap Length 240 Ø overall 400 362.20 92 Ø60mm foul air trap 340 Ø60 45 387.40 Grating level 240mm 340mm Ømm 400mm Ø60mm 45mm 3 3 4 4 2 Ø60mm Ø2mm Ømm 350mm Note: For guidance on the installation of the sump unit please refer to the ACO MultiDrain PPD installation manual or visit www.aco.co.uk. 5 including channel: 6 including channel: 075 = 287mm (6. l/s) 075 = 32mm (6. l/s) Grating level 0 = 32mm (7. l/s) 0 = 337mm (7. l/s) 0.0 = 362mm (9.2 l/s) 0.0 = 387mm (9.2 l/s) 5 6 Roddable foul air trap LLDPE Ømm Roddable foul air trap LLDPE Ø60mm Note: For ACO Universal Gully details please refer to page 28. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain PPD ACO MultiDrain MPPD How to select the correct grating The load class application of the channel system once installed is determined by the load class of the gratings fitted e.g. Load Class C 250 gratings fitted to a ACO MultiDrain PPD channel equals C 250 channel system. All of the suitable gratings are shown here and are listed in load class order. Primary consideration should be given to the application load requirement when selecting a grating. Refer to the chart on page 7 for load class definitions and typical applications. ACO Drainlock Fitted as standard to all ACO MultiDrain PPD gratings, this fastening system simply clips into the channel for rapid installation. A selection of the ACO Drainlock gratings is fitted with an anti shunt feature that restricts unwanted grating movement when installed. Please see grating tables for this option. Security locking option In areas where unwanted grating removal needs to be restricted, such as schools and prisons, the ACO Drainlock security locking system can be used. Gratings suitable for use with this system are indicated by. This system is fitted to the gratings by two M6 security bolts and clamps the grating in place preventing removal. A key for removal is supplied separately. Instructions for fitting this system are included in the ACO MultiDrain PPD installation manual. Traditional gratings for Load Class A 5 applications Product code 26 Slotted galvanised steel 400DL Length 0 Width overall 23 overall 2 Slot width / hole dia Intake area mm 2 /m 3200 Anti shunt feature Weight (kg) 2.20 26 Slotted galvanised steel 402DL 23 2 3200.00 2666 Perforated galvanised steel 2666DL 0 23 2 6 7800 2.20 2667 Perforated galvanised steel 2667DL 23 2 6 7800.00 400DL / 402DL Slotted galvanised steel 2666DL / 2667DL Perforated galvanised steel Traditional gratings for Load Class C 250 applications 4 Product code 2680 Heelguard composite black 522DL Length Width overall 23 overall 2 Slot width / hole dia 8 Intake area mm 2 /m 4250 Anti shunt feature Weight (kg).20 2673 Intercept ductile iron 507DL 23 2 3 x 2 43000 3.50 264 Slotted galvanised steel 423DL 0 23 2 3200 4.30 265 Slotted galvanised steel 424DL 23 2 3200 2.20 2656 Perforated galvanised steel 2656DL 0 23 2 6 7800 2.20 2657 Perforated galvanised steel 2657DL 23 2 6 7800.00 268 Mesh galvanised steel 4DL 0 23 2 25 x 2 88000 3. 269 Mesh galvanised steel 42DL 23 2 25 x 2 88000.50 522DL Heelguard composite 507DL Intercept ductile iron 423DL / 424DL Slotted galvanised steel 2656DL / 2657DL Perforated galvanised steel 4DL / 42DL Mesh galvanised steel Indicates security locking available. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain MPPD Brickslot tops and access top for Load Class C 250 applications 23460 Brickslot top galvanised steel 23460 Length 0 35 overall 5 Slot width /hole dia Intake area (mm 2 /m) 00 Weight (kg) 6.54 2346 Brickslot top galvanised steel 2346 35 5 00 3.40 23462 Brickslot access top galvanised steel 23462 35 5 00 6.55 mm 23460 / 2346 Brickslot top galvanised steel Slot detail 23462 Brickslot access top galvanised steel. Traditional gratings for Load Class C 250 / D 400 * applications MPPD Product code 23405 Heelguard ductile iron 23405DL Length Width overall 23 overall 2 Slot width / hole dia 8 Intake area mm 2 /m 25400 Anti shunt feature Weight (kg) 4.20 23406 Solid cover ductile iron 23406DL 23 2 4.50 23408 Slotted ductile iron 23408DL 23 2 2 36200 3.80 23405DL Heelguard ductile iron 23406DL Solid cover ductile iron 23408DL Slotted ductile iron Brickslot tops and access top for Load Class C 250 / D 400 * applications 23465 Brickslot top galvanised steel 23465 Length 0 35 overall 5 Slot width /hole dia Intake area (mm 2 /m) 00 Weight (kg) 6.70 5 23466 Brickslot top galvanised steel 23466 35 5 00 3.43 23467 Brickslot access top galvanised steel 23467 35 5 00 6.43 mm 23465 / 23466 Brickslot top galvanised steel Grating accessories Slot detail 23467 Brickslot access top galvanised steel. 2345 Drainlock security locking system Length overall 0. 2346 Drainlock security key 0.0 367 Drainlock grating lifting tool 835 0. Indicates security locking available. *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain PPD ACO MultiDrain MPPD hydraulic performance tables 6 Hydraulic capacities The table opposite shows the maximum capacity of the channel, assuming uniform lateral inflow to the channel. The capacity will depend on the length of channel to the outlet and on any slope along the channel. Q (l/s) is the maximum total flow that the channel can carry. q (l/s/m) is the maximum possible lateral inflow. A (m 2 ) is the maximum area that can be drained and will depend on the design rainfall intensity chosen. The tabulated areas are for a rainfall intensity of 50 mm/h (0.04 l/s/m 2 ). At other rainfall intensities, the area can be determined by proportion, e.g. at 75mm/h, the maximum area drained will be the tabulated area x 50/75. ACO Water Management Design Services Team Please contact the ACO Water Management Design Services Team on 0462 86666 for advice on channels with nonuniform inflow, or channels receiving point inflows at the end or at intermediate locations. The ACO Water Management Design Services Team will be pleased to assist with any technical queries, scheme designs or parts schedules. Designing a drainage system An example design method is provided on page 29 to help determine your drainage requirements. This example will enable you to use the hydraulic performance tables on this page. ACO MultiDrain MPPD 075 shallow depth channel Length to Outlet (m) 20 30 40 50 60 Length to Outlet (m) 20 30 40 50 60 70 80 90 0% 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ).4.3.2..0.0 0% 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) 4.7 4.2 3.9 3.7 3.5 3.3 3. 2.9 2.8 2.8 0.4 0.06 0.04 0.03 0.02 0.02 0.47 0.2 0.3 0.09 0.07 0.06 0.04 0.04 0.03 0.03 98 9 85 80 75 73 338 302 28 264 252 238 224 22 204 200.6.7.8.8.8.8 5.2 5.6 5.9 6.0 6. 6. 6.2 6.2 6.2 6.2 0.6 0.09 0.06 0.04 0.04 0.03 0.52 0.28 0.20 0.5 0.2 0. 0.09 0.08 0.07 0.06 4 24 28 28 29 29 ACO MultiDrain MPPD 0 shallow depth channel Length to Outlet (m) 20 30 40 50 60 375 403 423 432 437 44 443 445 447 448 2.0 2.2 2.3 2.4 2.4 2.5 0% 0.5% % 6.2 7.0 7.5 7.7 7.9 8. 8.2 8.3 8.3 8.3 0.20 0. 0.08 0.06 0.05 0.04 Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) 2.2 2. 2.0.9.8.7 0.22 0. 0.07 0.05 0.04 0.03 6 52 44 38 29 2 2.7 2.9 3.0 3.0 3.0 3. 0.27 0.5 0. 0.08 0.06 0.05 ACO MultiDrain MPPD No 0.0J constant depth channel 94 2 26 28 29 220 3. 3.6 3.8 3.9 4.0 4.0 0.3 0.8 0.3 0. 0.08 0.07 0.62 0.35 0.25 0.9 0.6 0.3 0.2 0. 0.09 0.08 4 58 67 73 75 77 224 259 275 280 285 289 446 504 539 556 569 582 590 595 598 599

ACO MultiDrain M50PPD ACO MULTIDRAIN M50PPD M50PPD 50mm The ACO MultiDrain M50PPD channel is available in one constant depth and has integral galvanised steel protective edge rails to give the channel optimum protection from vehicular traffic. The channel is manufactured from recycled polypropylene, a robust lightweight material. For the ACO MultiDrain M50PPD range of gratings to suit these channels please refer to pages 20 and 2. 67m 2* Channel width 50mm Catchment area Shallow constant depth channels 7 Constant depth channels Load Class D 400 i To compare the different features of the ACO MultiDrain PPD range, use the product selector on page. Grating choice WIDE Brickslot top available *Example run based on 50m length to outlet

ACO MultiDrain PPD ACO MultiDrain M50PPD Constant depth channel with galvanised steel edge rails 5 M50PPD No.0.0J* Length 0 92 overall 2 70 4.02 92mm 0mm 50mm 2mm 70mm 22mm 37mm M50PPD m constant depth channel Universal closing end cap 93 M50PPD universal closing end cap Length 88 overall 2 0.4 mm 88mm 2mm M50PPD universal closing end cap 8 Outlet connector 288 Ø60mm vertical outlet connector Length Ø60 overall 80 0.30 80mm 80mm 80mm 62mm Ø60mm M50PPD Ø60mm vertical outlet connector (max flow 8 l/s) J Indicates side knockout for 90 channel connection. Knockout on both sides of the channel. * Indicates channels supplied with vertical outlet knockout for use with Ø60mm outlet connectors. Outlet connectors supplied separately, see table above for details. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain M50PPD M50PPD sump unit 386 Black plastic sump unit with galvanised steel silt bucket and Ø60mm outlet connector Length 350 Ø2 overall 5 3.70 Grating level Standard sump outlets = Ømm outlet 2 = Ø60mm outlet Ømm Ømm Ø68mm 5mm 692mm (7. l/s) 422mm (2.6 l/s) 422mm (2.6 l/s) 692mm (8.0 l/s) 2 Foul air traps 9 92 Ø60mm Ø2mm Ømm 350mm Note: For guidance on the installation of the sump unit please refer to the ACO MultiDrain PPD installation manual or visit www.aco.co.uk. Ømm foul air trap Ø60mm foul air trap Length 240 340 Ø Ø60 overall 400 45 422 447.20.40 Grating level Grating level 240mm 9 Ømm 400mm M50PPD 422mm (2.6 l/s) 340mm Ø60mm 45mm 447mm (2.6 l/s) Roddable foul air trap LLDPE Ømm Roddable foul air trap LLDPE Ø60mm Note: For ACO Universal Gully details please refer to page 28. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain PPD ACO MultiDrain M50PPD How to select the correct grating The load class application of the channel system once installed is determined by the load class of the gratings fitted e.g. Load Class C 250 gratings fitted to a ACO MultiDrain PPD channel equals C 250 channel system. All of the suitable gratings are shown here and are listed in load class order. Primary consideration should be given to the application load requirement when selecting a grating. Refer to the chart on page 7 for load class definitions and typical applications. ACO Drainlock Fitted as standard to all ACO MultiDrain PPD gratings, this fastening system simply clips into the channel for rapid installation. A selection of the ACO Drainlock gratings is fitted with an anti shunt feature that restricts unwanted grating movement when installed. Please see grating tables for this option. Security locking option In areas where unwanted grating removal needs to be restricted, such as schools and prisons, the ACO Drainlock security locking system can be used. Gratings suitable for use with this system are indicated by. This system is fitted to the gratings by two M6 security bolts and clamps the grating in place preventing removal. A key for removal is supplied separately. Instructions for fitting this system are included in the ACO MultiDrain PPD installation manual. Traditional gratings for Load Class C 250 applications Product code 3073 Intercept ductile iron 3073DL Length 73 overall 2 Slot width /hole dia 2 x 30 Intake area mm 2 /m 59 Anti shunt feature Weight (kg) 5.30 308 Mesh galvanised steel 308DL 0 73 30 23 x 7 5 7.40 309 Mesh galvanised steel 309DL 73 30 23 x 7 5 3.70 3073DL Intercept ductile iron 308DL / 309DL Mesh galvanised steel Traditional gratings for Load Class C 250 / D 400 * applications 20 Product code 236 Heelguard ductile iron 236DL Length 73 overall 28 Slot width /hole dia 8 Intake area mm 2 /m 40000 Anti shunt feature Weight (kg) 6.80 2360 Solid cover ductile iron 2360DL 73 28 6.70 2364 Slotted ductile iron 2364DL 73 28 2 57664 6.40 236DL Heelguard ductile iron 2360DL Solid cover ductile iron 2364DL Slotted ductile iron Indicates security locking available. *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain M50PPD Brickslot tops and access top for Load Class C 250 / D 400* applications 2375 Brickslot top galvanised steel 2375 Length 0 85 overall 5 Slot width /hole dia Intake area (mm 2 /m) 00 Weight (kg) 8.20 2376 Brickslot top galvanised steel 2376 85 5 00 4.20 2377 Brickslot access top galvanised steel 85 5 00 7.50 mm 2375 / 2376 Brickslot top galvanised steel Slot detail 2377 Brickslot access top galvanised steel. Grating accessories 2365 Drainlock security locking system Length overall Invert Type 0. M50PPD 2346 Drainlock security key 0.0 367 Drainlock grating lifting tool 835 0. 2 *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain PPD ACO MultiDrain M50PPD hydraulic performance tables Notes for ACO MultiDrain M50PPD hydraulic tables Maximum capacities for each constant depth channel, assuming uniform lateral inflow to the channel. Q (l/s) is the maximum total flow that the channel can carry. q (l/s/m) is the maximum possible lateral inflow. A (m 2 ) is the maximum area that can be drained and will depend on the design rainfall intensity chosen. The tabulated areas are for a rainfall intensity of 50 mm/h (0.04 l/s/m 2 ). At other rainfall intensities, the area can be determined by proportion, e.g. at 75mm/h, the maximum area drained will be the tabulated area x 50/75. ACO MultiDrain M50PPD No 0.0J constant depth channel Length to Outlet (m) 20 30 40 50 60 70 80 90 0% 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ).6.9.3 9.8 9.3 8.9 8.5 8.2 8. 8.0.6 0.55 0.34 0.24 0.9 0.5 0.2 0. 0.09 0.08 835 787 743 704 67 639 609 593 583 576 2.9 4.0 4.8 5.4 5.9 6.2 6.4 6.6 6.7 6.8.29 0.70 0.49 0.39 0.32 0.27 0.23 0.2 0.9 0.7 929 8 66 4 65 83 96 205 2 5.2 7.4 8.8 9.6 20.3 20.8 2.3 2.6 2.9 22.0.52 0.87 0.63 0.49 0.4 0.35 0.30 0.27 0.24 0.22 94 253 352 42 462 530 558 575 584 ACO Water Management Design Services Team Please contact the ACO Water Management Design Services Team on 0462 86666 for advice on channels with nonuniform inflow, or channels receiving point inflows at the end or at intermediate locations. The ACO Water Management Design Services Team will be pleased to assist with any technical queries, scheme designs or parts schedules. Designing a drainage system 22 An example design method is provided on page 29 to help determine your drainage requirements. This example will enable you to use the hydraulic performance tables on this page.

ACO MultiDrain M200PPD ACO MULTIDRAIN M200PPD The ACO MultiDrain M200PPD channel is available in one constant depth and has integral galvanised steel protective edge rails to give the channel optimum protection from vehicular traffic. The channel is manufactured from recycled polypropylene, a robust lightweight material. For the ACO MultiDrain M200PPD gratings to suit these channels please refer to pages 26. 200mm Channel width 200mm 2* Catchment 440m area Shallow constant depth channels 23 M200PPD Constant depth channels Load Class D 400 i Grating choice WIDE To compare the different features of the ACO MultiDrain PPD range, use the product selector on page. Brickslot top not available *Example run based on 50m length to outlet

ACO MultiDrain PPD ACO MultiDrain M200PPD Constant depth channel unit with galvanised steel edge rails 58 M200PPD No.0.0J* Length 0 242 overall 265 220 4.90 242mm 0mm 200mm 265mm 220mm 22mm 93mm M200PPD m constant depth channel Universal closing end cap 98 M200PPD universal closing end cap Length 238 overall 265 0.2 mm 238mm 265mm 24 M200PPD universal closing end cap Outlet connector 289 Ø200mm vertical outlet connector Length Ø200 overall 0.40 220mm 220mm 208mm mm Ø200mm M200PPD Ø200mm vertical outlet connector (max flow 26.7 l/s) J Indicates side knockout for 90 channel connection. Knockout on both sides of the channel. * Indicates channels supplied with vertical outlet knockout for use with Ø200mm outlet connectors. Outlet connectors supplied separately, see table above for details. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain M200PPD M200PPD sump unit 387 Black plastic sump unit with galvanised steel silt bucket and Ø200mm outlet connector Length 452 Ø255 overall 5 4.90 Standard sump outlets Grating level 2 3 = Ømm outlet = Ø60mm outlet = Ø200mm outlet Ømm Ø2mm 5mm 747mm (26.7 l/s) Ø255mm 452mm Foul air trap 92 Ø60mm roddable foul air trap Length 340 Grating level Ø60 overall 45 502.40 340mm 25 Ø60mm 45mm 477mm (3.5 l/s) 747mm (26.7 l/s) 2 3 Ø60mm Ø200mm Note: For guidance on the installation of the sump unit please refer to the ACO MultiDrain PPD installation manual or visit www.aco.co.uk. M200PPD 502mm (3.5 l/s) Roddable foul air trap LLDPE Ø60mm Note: For ACO Universal Gully details please refer to page 28. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain PPD ACO MultiDrain M200PPD How to select the correct grating The load class application of the channel system once installed is determined by the load class of the gratings fitted e.g. Load Class C 250 gratings fitted to a ACO MultiDrain PPD channel equals C 250 channel system. All of the suitable gratings are shown here and are listed in load class order. Primary consideration should be given to the application load requirement when selecting a grating. Refer to the chart on page 7 for load class definitions and typical applications. ACO Drainlock Fitted as standard to all ACO MultiDrain PPD gratings, this fastening system simply clips into the channel for rapid installation. A selection of the ACO Drainlock gratings is fitted with an anti shunt feature that restricts unwanted grating movement when installed. Please see grating tables for this option. Security locking option In areas where unwanted grating removal needs to be restricted, such as schools and prisons, the ACO Drainlock security locking system can be used. Gratings suitable for use with this system are indicated by. This system is fitted to the gratings by two M6 security bolts and clamps the grating in place preventing removal. A key for removal is supplied separately. Instructions for fitting this system are included in the ACO MultiDrain PPD installation manual. Traditional gratings for Load Class C 250 applications Product code 3473 Intercept ductile iron 3473DL Length 223 overall 35 Slot width /hole dia 30.5 x 4 Intake area (mm 2 /m) 90 Anti shunt feature Weight (kg) 7.50 348 Mesh galvanised steel 348DL 0 223 40 23 x 7 54 2.00 349 Mesh galvanised steel 349DL 223 40 23 x 7 54 6.00 3473DL Intercept ductile iron 348DL / 349DL Mesh galvanised steel Traditional gratings for Load Class C 250 / D 400 * applications 26 Product code 2322 23220 Heelguard ductile iron 2322DL Solid cover ductile iron 23220DL Length 223 223 overall 32 32 Slot width /hole dia 8 Intake area (mm 2 /m) 47300 Anti shunt feature Weight (kg).30.00 23224 Slotted ductile iron 23224DL 223 32 2 36200 9.80 2322DL Heelguard ductile iron 23220DL Solid cover ductile iron 23224DL Slotted ductile iron Grating accessories 23225 Drainlock security locking system Length overall Invert Type 0. 2346 Drainlock security key 0.0 367 Drainlock grating lifting tool 835 0. Indicates security locking available. *Not suitable for carriageways of public roads or motorways. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

ACO MultiDrain M200PPD hydraulic performance tables Notes for ACO MultiDrain M200PPD Hydraulic tables Maximum capacities for each constant depth channel, assuming uniform lateral inflow to the channel. Q (l/s) is the maximum total flow that the channel can carry. q (l/s/m) is the maximum possible lateral inflow. A (m 2 ) is the maximum area that can be drained and will depend on the design rainfall intensity chosen. The tabulated areas are for a rainfall intensity of 50 mm/h (0.04 l/s/m 2 ). At other rainfall intensities, the area can be determined by proportion, e.g. at 75mm/h, the maximum area drained will be the tabulated area x 50/75. ACO Water Management Design Services Team ACO MultiDrain M200PPD No 0.0J constant depth channel Length to Outlet (m) 20 30 40 50 60 70 80 90 20 40 60 80 200 0% 0.5% % Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) Q (l/s) q (l/s/m) A (m 2 ) 22.5 22.0 2.3 20.8 20.0 9.5 8.8 7.9 7.4 7.2 6.3 5.5 4.9 4.4 4.2 2.25. 0.7 0.52 0.40 0.33 0.27 0.22 0.9 0.7 0.4 0. 0.09 0.08 0.07 620 584 530 498 440 406 350 288 250 235 75 8 75 40 22 24.2 27.8 29.6 30.6 3.5 32.4 33. 33.5 33.9 34.4 35.3 35.8 36.3 36.5 36.6 2.42.39 0.99 0.76 0.63 0.54 0.47 0.42 0.38 0.34 0.29 0.26 0.23 0.20 0.8 740 2000 230 2200 2270 2335 2380 24 2440 2480 2540 2574 266 2625 2635 25.8 32.6 35.6 37.5 39.0 39.9 40.8 42.5 42.9 43.8 45. 46. 47. 47.6 47.9 2.58.63.9 0.94 0.78 0.66 0.58 0.53 0.48 0.44 0.38 0.33 0.29 0.26 0.24 860 2350 2560 2700 28 2870 2940 3057 3090 350 3249 3320 3390 3430 3450 Please contact the ACO Water Management Design Services Team on 0462 86666 for advice on channels with nonuniform inflow, or channels receiving point inflows at the end or at intermediate locations. The ACO Water Management Design Services Team will be pleased to assist with any technical queries, scheme designs or parts schedules. Designing a drainage system M200PPD An example design method is provided on page 29 to help determine your drainage requirements. 27 This example will enable you to use the hydraulic performance tables on this page.

ACO MultiDrain PPD ACO Universal Gully ACO Universal Gully The ACO Universal Gully provides fast and simple connection between any channel size up to 200mm width in the ACO channel drainage range. It also provides an outlet to connect to traditional underground drainage. The ACO Universal Gully is a recycled plastic modular system with a ductile iron grating and frame. Instructions for installing this gully are included in the ACO MultiDrain PPD installation manual. ACO Universal Gully and accessories 3360 Gully assembly and bucket 60 Length 440 440 overall 35 870 Invert Type 78.80 33602 Gully assembly no bucket 602 440 440 35 870 77.40 33607 Gully top assembly 607 440 440 650 73. 33605 Base unit 605 Ø375 Ø375 750 3 4.30 33603 Intermediate unit 603 440 440 55 5. 33604 Grating and frame 604 440 440 69.50 7060 Connector 65 Ø 40 7.00 33606 Bucket polyethylene Ø275 Ø275 250.40 660mm 660mm 28 mm 870mm 35mm 440mm mm 650mm 440mm Ø60mm 4045 l/s 440mm Gully top assembly 607, Gully pot supplied by others 440mm Gully assembly 60 and 602 mm Ø360mm Ø360mm 320mm 40mm Connector 65 Ømm Note: Plain UPVC 50mm 60mm SuperSleeve adaptor supplied with 60, 602 and 605 assembly. Grating slot width 9mm. These products are subject to weight and dimensional tolerances. The dimensions shown on this page are for guidance purposes only.

Designing a drainage system The hydraulic capacity of channels accepting lateral inflow all along their length can be calculated by the analysis of the differential equations for spatially varied flow, a procedure that requires a computer program such as the proprietary ACO Hydro software. For detailed designs using Hydro, please contact the ACO Water Management Design Services Team. The team should also be consulted for advice where the inflow is not uniformly distributed along the channel. The hydraulic performance tables within the relevant sections have been produced from the ACO Hydro software to facilitate a quick manual design method for the determination of the drainage requirements. The columns of drainage catchment area (A m 2 ) are based on a rainfall intensity of 50mm/h, but can be adapted for use at any rainfall intensity. The columns of maximum flow rate (Q l/s) and maximum lateral inflow (q l/s/m) can be used at any rainfall intensity. DESIGN EXAMPLE i = 50mm/h D = 5m L =40m For a design of ACO MultiDrain MPPD, assume the following figures: D = 5m (depth of catchment area) L = 40m (length of channel run = length of catchment) i = 50mm/h (design rainfall intensity) Ground slope = 0% Note that any other rainfall intensity may be used. Typical intensities (from BS EN 752) are 50mm/h for areas where some ponding could be tolerated for a few minutes after heavy rainfall, or 75mm/h where ponding cannot normally be tolerated. 29. Determine the area Area = L x D = 40 x 5 = 600m 2 For a quick analysis, see the tables and the columns for area on page 6. 600m 2 is too large for one 40m run of ACO MultiDrain MPPD. However a 20m run can drain 302m 2, so one central outlet will work, with 20m of channel each side, each draining 300m 2. Or for a more detailed analysis, determine the total flow rate, as follows: 2. Determine total flow (Q) Q = (area x i) / 3600 = (600 x 50) / 3600 = 8.33 l/s 3. Determine lateral inflow (q) q = Q / L = 8.33 / 40 = 0.208 l/s/m 4. Determine suitable channel sizes and lengths For ACO MultiDrain MPPD interpolation between the value at 20m and 30m, a maximum length of 2m could carry 0.208 l/s/m. Alternatively use ACO MultiDrain M50PPD to an end outlet, where the tables show that 40m can carry 9.8 l/s and drain 704m². 5. Check Outlet capacity Ensure that the proposed outlet has sufficient hydraulic capacity by reference to the product technical pages.

ACO MultiDrain PPD Installation detail CHANNELS WITH TRADITIONAL GRATINGS Asphalt pavement Concrete pavement or block paving Installation within existing slab Channel to be bedded in epoxy mortar recommended 25mm minimum thickness. This may vary depending on type of mortar used. Engineering advice may be required. Y 3 Y 2 Detail A Note 5.0 Note: Movement joint to engineers detail Detail A Wearing course Detail A Pocket to be cut into existing slab where channel is to be installed see note 7.0 Y X Concrete slab X Y Block Concrete bed and haunch see note 7.0 Z Concrete bed and haunch see note 7.0 Z Slab Load Class A 5 Detail A Detail A 3mm 5mm Block Block Pavement or haunch (construction varies) Grating Channel wall 30.0 Ground conditions: The customer should ensure that the minimum dimensions shown are suitable for the existing ground conditions. Engineering advice may be required. 2.0 Block pavements: The channels must be supported laterally and therefore blocks must be restrained from movement by bedding securely. e.g. by using an Epoxy or Polymer Modified Mortar for bed and perpendicular joints (for example RONAFIX Mortar Mix C or similar). Engineering advice may be required. 3.0 Surface cracks: Alternate crack control and movement joints transversely within bed and haunch may reduce unsightly surface cracking. Engineering advice may be required. 4.0 Joint sealant: Where ACO channel joints and fittings are to be sealed (where used in foul water applications or where impermeability is required, for example) contact a sealant specialist for guidance on the most appropriate sealing compound to use. 5.0 Surface protection: In asphalt pavements avoid contact between compaction equipment and channel/grating. This may be achieved by ensuring that the finished surface level lies above the grating level (by at least 3mm). Stones should be removed from grating prior to laying/rolling wearing course. 6.0 General installation notes: See ACO drawing EE003 for further notes on installation. This information is available on request or is available for download from www.aco.co.uk. Gratings must be fitted before concreting. Best practice and workmanship ACO can give guidance with respect to the most suitable methods of installation for each of the products in the ACO MultiDrain PPD range. ACO MultiDrain PPD range should be installed using acceptable levels of workmanship and according to the National Code of Practice (UK: BS8000: Part 4: 989) in keeping with EN 433:2002 (Drainage channels for vehicular and pedestrian areas). Detailed installation statements and methodologies will vary for all sites as each will have different aspects deserving particular consideration, consequently the relevant approvals should be sought from the consulting engineer and/or the installer.

ACO MultiDrain PPD 6 ACO MultiDrain PPD ACO UNIVERSAL GULLY A. Excavate a 50mm bed and surround, B. Concrete* surround base unit and.0 Ground conditions: blind where necessary. Form pipes if required. Position gully The customer should ensure that the concrete* bed for base unit and set intermediate unit 2 to level. minimum dimensions shown are suitable on a mortar (or similar) levelling bed. for the existing ground conditions. Make pipe connections (PVCu or Engineering advice may be necessary. SuperSleve) as appropriate. 2.0 Block pavements: 2 2 The channel must be supported laterally and therefore blocks must be restrained from movement by bedding securely, e.g. by using an Epoxy or Polymer Modified Mortar for bed and perpendicular joints (for example RONAFIX Mortar Mix C or similar from Ronacrete, tel 0279 638700). Engineering advice may be required. Min 50mm (Class AC) Min 300mm (Class D) Min 50mm (Class AC) Min 300mm (Class D) Concrete bed & haunch minimum strength class 25 N/mm 2 Concrete bed & haunch minimum strength class 25 N/mm 2 C. Concrete* bed for channels allowing D. Complete concrete* surround to unit 3.0 Surface cracks: levelling mortar bed if required. 2 allowing for frame levelling bed. Alternate crack control and movement Extend concrete bed around 2 (see Cut out knock outs on gully frame 3 joints traversally within bed and haunch fig. ). Install channels (see separate and cut profile of the channel from may reduce unsightly surface cracking. channel installation recommendations) inside of unit 2. Install gully and Engineering advice may be required. with taped external joints at junction haunch concrete* to the sides of of unit 2 and end of channels. channels as recommended in separate 4.0 Joint sealant: channel installation recommendations. Concrete bed & haunch minimum strength class 25 N/mm 2 Installation manual Uniclass L223 + L735 CI/SfB (52.5) Concrete bed & haunch minimum strength class 25 N/mm 2 Fig : Shutter around gully top 200mm (Class D) or 50mm (Class AC). Concrete* the supporting surround for the gully frame. EPIC J343 Concrete bed & haunch minimum strength class 25 N/mm 2 Extended concrete Class D shown. 3 Concrete bed & haunch minimum strength class 25 N/mm 2 Where ACO channel joints and fittings are to be sealed (where used in foul water applications or where impermeability is required, for example) contact a sealant specialist for guidance on the most appropriate sealing compound to use. 5.0 Surface protection: In asphalt pavements avoid contact between compaction equipment and channel/grating. This may be achieved by ensuring that the finished surface level lies above the grating level (by at least 3mm). Stones should be removed from grating prior to laying/rolling wearing course. 6.0 General installation notes: See ACO drawing EE003 for further notes on installation. This information is available on request or is available for download from www.aco.co.uk. Gratings must be fitted before concreting. Best practice and workmanship. ACO can give guidance with respect to the most suitable methods of installation for each of the products in the ACO MultiDrain PPD range. ACO MultiDrain PPD range should be installed using acceptable levels of workmanship and according to the National Code of Practice (UK: BS8000: Part 4: 989) in keeping with EN 433:2002 (Drainage channels for vehicular and pedestrian areas). Detailed installation statements and methodologies will vary for all sites as each will have different aspects deserving particular consideration, consequently the relevant approvals should be sought from the consulting engineer and/or the installer. * Refer to note 7.0 on page 5 Channel base knockout details ACO MultiDrain PPD channels are supplied with a preformed knockout in the base of the channels. This detail at the male end of the channel allows vertical connection to Ømm, Ø60mm and Ø200mm UPVC pipes and sump via outlet connectors. The knockout on the base of the channel is indicated by a hammer symbol. The method of removal and pipe connection is described below. Knockout detail. METHOD: Step : Support channel around knockout detail by placing the channel on sand or soft earth for example. Tap the knockout panel from the side indicated by the hammer symbol to remove panel. Step 2: Push fit outlet connector with integral EPDM seal into recess. Connect ongoing pipework onto connector as required. 90 channel connection detail An additional feature provided on the channels* is removable side wall panels. This feature allows channel runs to be connected together to form T or L junctions for continuous water flow through the system. Where channel connections are to be made to the side wall of these units a joint profile is provided to aid alignment and fast installation. METHOD: Step : Insert the grating to support channel. Tap segments of the knockout panel as indicated to remove. Step 2: Tidy up any remaining material. Channel connection can now be made. Removable side wall panel. *This feature does not apply to shallow depth channels. These preparation steps should be read in conjunction with the Best practice and workmanship note on page 4. Creating 0.5m channels The ACO MultiDrain PPD m channels can be cut down to form 0.5m units. A cutting guide is provided on the channel body. Once cut, connection profiles are provided to enable simple and fast installation. The method of cutting the channels is described below. Cutting guide for 0.5m channel units METHOD: Step : Place saw into the cutting guide as shown. Cut channel ensuring the saw blade follows the guide provided. Step 2: Once the channel is cut tidy up edges as required. Channels can now be used as 0.5m units. 7 CHANNELS WITH BRICKSLOT GRATINGS Standard Brickslot top Access / sump top Detail B 3mm5mm Paviours directly adjacent to frame to be bedded using an epoxy mortar. See note 2.0 Detail B Sub base Sand bed Paviours directly adjacent to frame to be bedded using an epoxy mortar. See note 2.0 Detail B Sub base Sand bed Paviour Paviour Paviour Paviour Epoxy Mortar (See Note 2.0) X Y Z Concrete bed and haunch see note 7.0 Y Z X Concrete bed and haunch see note 7.0 Pavement Steel Upstand Adjacent to a structure option Adjacent to a structure option 2 Sealant Min 80mm Polymer modified mortar or epoxy resin grout ACO MultiDrain PPD channel with Brickslot top Note: varies with unit specified Concrete bed and haunch see note 7.0 ACO MultiDrain PPD channel with Brickslot top Note: varies with unit specified Concrete bed and haunch see note 7.0 i Face of structure Class C min 50mm Class D min 200mm Face of structure Class C min 50mm Class D min 200mm An electronic version of the ACO MultiDrain PPD installation detail is available to download from the ACO website. Visit www.aco.co.uk. 7.0 Minimum dimensions of concrete surround: For Load Class A 5, the channel is to be bedded on a suitable base according to the ground conditions. For Load Classes B 25 to D 400*, a concrete bed and surround is required. Unless otherwise stated, all units in mm. Load Class Dimension A 5 B 25 C 250 D 400* x Min 50 Min 50 Min 200 y Full depth of channel (Less Y2 if necessary) Y2 (Asphalt pavement only) Max 80 Max 25 Max 25 Y3 (Asphalt pavement only) Max 5 Max 60 Max 60 z Min 50 Min 50 Min 200 Minimum concrete compressive strength 25 N/mm 2 25 N/mm 2 30 N/mm 2 *e.g. parking areas for all types of road vehicle. Not suitable for carriageway of roads or motorways. 8.0 Security locking: All the gratings are held in the channel units by the ACO Drainlock fastening system. In addition, certain gratings can be locked into place with the use of an optional security locking system. Please see grating charts for this option. See installation drawing EE0403 for further notes on the installation of this system. This information is available on request or is available for download from www.aco.co.uk. 3 i ACO Water Management: Civils + Infrastructure Installation notes: General notes: Preparing the channel system for installation This section provides guidance on the preparation steps that may be required for the installation of ACO MultiDrain PPD. Specific features of the channel system are shown along with instructions for use. ACO MultiDrain PPD channel drainage system Guidance on the preparation, installation and maintenance of this system is given in the ACO MultiDrain PPD Installation manual. This document is available to download from www.aco.co.uk or contact marketing@aco.co.uk to request your printed copy.

ACO MultiDrain PPD ACO UNIVERSAL GULLY Installation notes: A. Excavate a 50mm bed and surround, blind where necessary. Form concrete* bed for base unit and set on a mortar (or similar) levelling bed. Make pipe connections (PVCu or SuperSleve) as appropriate. Min 50mm (Class AC) Min 300mm (Class D) 2 Min 50mm (Class AC) Min 300mm (Class D) Concrete bed & haunch minimum strength class 25 N/mm 2 B. Concrete* surround base unit and pipes if required. Position gully intermediate unit 2 to level. 2 Concrete bed & haunch minimum strength class 25 N/mm 2 General notes:.0 Ground conditions: The customer should ensure that the minimum dimensions shown are suitable for the existing ground conditions. Engineering advice may be necessary. 2.0 Block pavements: The channel must be supported laterally and therefore blocks must be restrained from movement by bedding securely, e.g. by using an Epoxy or Polymer Modified Mortar for bed and perpendicular joints (for example RONAFIX Mortar Mix C or similar from Ronacrete, tel 0279 638700). Engineering advice may be required. 32 C. Concrete* bed for channels allowing D. Complete concrete* surround to unit levelling mortar bed if required. 2 allowing for frame levelling bed. Extend concrete bed around 2 (see Cut out knock outs on gully frame 3 fig. ). Install channels (see separate channel installation recommendations) with taped external joints at junction and cut profile of the channel from inside of unit 2. Install gully and haunch concrete* to the sides of of unit 2 and end of channels. channels as recommended in separate channel installation recommendations. Concrete bed & haunch minimum strength class 25 N/mm 2 Concrete bed & haunch minimum strength class 25 N/mm 2 Concrete bed & haunch minimum strength class 25 N/mm 2 3 Concrete bed & haunch minimum strength class 25 N/mm 2 3.0 Surface cracks: Alternate crack control and movement joints traversally within bed and haunch may reduce unsightly surface cracking. Engineering advice may be required. 4.0 Joint sealant: Where ACO channel joints and fittings are to be sealed (where used in foul water applications or where impermeability is required, for example) contact a sealant specialist for guidance on the most appropriate sealing compound to use. 5.0 Surface protection: In asphalt pavements avoid contact between compaction equipment and channel/grating. This may be achieved by ensuring that the finished surface level lies above the grating level (by at least 3mm). Stones should be removed from grating prior to laying/rolling wearing course. 6.0 General installation notes: See ACO drawing EE003 for further notes on installation. This information is available on request or is available for download from www.aco.co.uk. Gratings must be fitted before concreting. i Fig : Shutter around gully top 200mm (Class D) or 50mm (Class AC). Concrete* the supporting surround for the gully frame. Extended concrete Class D shown. An electronic version of the ACO Universal Gully installation detail is available to download from the ACO website. Visit www.aco.co.uk. Best practice and workmanship. ACO can give guidance with respect to the most suitable methods of installation for each of the products in the ACO MultiDrain PPD range. ACO MultiDrain PPD range should be installed using acceptable levels of workmanship and according to the National Code of Practice (UK: BS8000: Part 4: 989) in keeping with EN 433:2002 (Drainage channels for vehicular and pedestrian areas). Detailed installation statements and methodologies will vary for all sites as each will have different aspects deserving particular consideration, consequently the relevant approvals should be sought from the consulting engineer and/or the installer. * Refer to note 7.0 on page 3

Chemical resistance chart ACO polypropylene has a high resistance to dilute acids and alkalis, and is unaffected by road salt, fuel and oil, and other commonly encountered chemicals. Further details of the chemical resistance can be obtained from the ACO Water Management Design Services Team or for particular chemicals, samples of the polypropylene channels can be supplied to customers for their own testing. The chemical resistance will also depend on the temperature of the effluent. The resistance of the gratings and edge rails should also be considered. This chemical resistance chart refers to chemical at ambient temperatures (20 C) and the results are for general guidance only. Important considerations for chemical environments When reviewing potential applications for ACO MultiDrain PPD in chemical environments, the following issues should be considered; Type(s) & mixture of chemical(s). Concentration percentages. Contact time with drainage system. Temperatures of chemicals flowing into the drainage system (82 C max). Flushing system employed to clear chemicals from the drainage system. Cleaning agents should be checked for compatibility with channel materials. ACO samples can be used for final determination of chemical resistance. Grating, locking mechanism, edge rail, outlet and sump unit materials should be checked for chemical resistance. Check sealant for compatibility. Chemical medium Acetic acid, glacial Acetic acid Acetic anhydride Acetone Aluminium sulfate Ammonium chloride Ammonium nitrate Ammonium phosphate Ammonium sulfate Aniline (aminobenzene) Aniline hydrochloride Aromatic hydrocarbons Aqua regia Barium chloride Beer Benzene Benzyl alcohol Benzyl chloride Bleaching liquors Borax Butanol (butyl alcohol) Butyl acetate Butyric acid Calcium carbonate Calcium chloride Calcium hydroxide Calcium nitrate Carbon disulfide Carbon tetrachloride Carbonic acid Castor oil Chlorine water Chlorobenzene Chloroform (trichloromethane) Chromic acid Citric acid Copper chloride Copper nitrate Copper sulfate Cyclohexane Diesel fuel (DERV) Dimethyl formamide Ethanol (Ethyl Alcohol) Ethanolamine Ethyl acetate Ethyl ether Ethylene glycol Fatty acids Ferrous chloride Ferrous sulfate Ferric chloride Ferric sulfate Formaldehyde Formic acid Fruit juice Fuel oil Gasoline (petrol) Glycerine Hydrazine Hydrobromic acid Resistance: % conc Polypropylene Fair 80 Fair No No No Fair Fair Fair Fair (48 C) (48 C) (48 C) No No Saturated No Poor Poor 5 No No No 95 No No 40 Fair 50 Fair 20 / / Fair Chemical medium Hydrochloric acid Hydrofluoric acid Hydrogen peroxide Lactic acid Lead acetate Magnesium chloride Magnesium sulfate Maleic acid Methyl ethyl ketone (MEK) Motor oil Nickel chloride Nickel sulfate Nitric acid Nitrobenzine Oleic acid Oxalic acid Perchlorethyline Perchloric acid Phosphoric acid Plating liquors Potassium carbonate (Potash) Potassium chloride Potassium dichromate Potassium hydroxide Potassium nitrate Potassium permanganate Potassium sulfate Pyridine Sodium acetate Sodium benzoate Sodium carbonate Sodium chlorate Sodium chloride Sodium hydroxide (caustic soda) Sodium hypochlorite Sodium nitrate Sodium peroxide Sodium silicate Sodium sulfate Sodium sulfide Sodium sulfite Sodium thiosulfate Stearic acid Sulfur dioxide Sulfuric acid Sulfuric acid Sulfuric acid at up to 48 C Tetrachloroethylene Tannic acid Tanning liquors Toluene Trichloroacetic acid Turpentine Urea Urine Water Xylene Zinc sulfate % conc 20 / (48 C) 50 / 40 No (48 C) (48 C) 35 80 (48 C) (48 C) (48 C) 75 >75 (at C) Resistance: Polypropylene / Fair / No Fair No Fair No Fair No 33

ACO MultiDrain PPD Frequently Asked Questions 34 Q WHAT LOAD CLASS DO I REQUIRE? Answer: The answer to this question is dependent on where the drainage system will be used. There are six load classes recognised in BS EN 433:2002. For further information on load classes and applications relevant to this system, please refer to page 7. Please note that all channels within the ACO MultiDrain PPD system are certified to BS EN 433: 2002 Load Class D 400*. The system has a wide range of gratings with varying load classes which, once installed with the channel, determines the system s load class. Careful consideration should be given to the application requirement when selecting a grating. * Not suitable for carriageways of public roads or motorways Q2 DO I NEED A SUMP UNIT/UNIVERSAL GULLY? Answer: This is dependent on the requirements for sediment collection or a foul air trap. If either of these are required then a sump or gully is necessary. If not you can use any of the other outlet options available. The ACO Universal Gully (3360) has a roddable foul air trap built into the side of the unit. Note that the hydraulic capacity of end outlets and bottom outlets will be much less than the capacity of a sump or gully. Q3 ARE ACO CHANNELS SUITABLE FOR USE WITH CHEMICALS? Answer: This is entirely dependent on the chemicals being used along with their temperature and concentration. For more information, please refer to the ACO MultiDrain PPD chemical resistance chart provided on page 33. Q4 WHICH PRODUCTS ARE SUITABLE FOR USE WITH LEVEL ACCESS THRESHOLDS? Answer: Most ACO channels are suitable for level thresholds and are Part M compliant. ACO recommend systems such as ACO MultiDrain PPD, ACO MultiDrain MD or ACO ParkDrain are used for public thresholds where security of the gratings needs to be taken into account. These systems are all available with Heelguard gratings which limit the possibility of stiletto heels being caught. Q5 IS THERE A REGULATION REGARDING HEELGUARD? Answer: No. Heelguard is name created by ACO for gratings where the slot width is around 8mm. ACO MultiDrain PPD has a choice of Heelguard gratings and also a selection of wider mm slot gratings. The standard for surface water drainage BS EN 433:2002, states that the maximum slot width in most pedestrian situations is 8mm. Q6 HOW MANY OUTLETS ARE REQUIRED IN A RUN? Answer: This depends entirely on the length of channel and the catchment area expected. A design example is provided in the hydraulics guide on page 29. If a specific hydraulic calculation is required, please contact the ACO Water Management Design Services Team on 0462 86666. Q7 DO YOU MANUFACTURE PRECURVED CHANNELS? Answer: No. ACO do not provide precurved units. However our sister division, ACO Building Drainage manufacture a stainless steel precurved product called ACO Radius channel and the ACO Sport product range includes channels to the 36.5m radius of an athletics track. For information on these products please call 0462 86666 or refer to www.aco.co.uk. Q8 ARE ACO CHANNELS SELF CLEANSING? Answer: Not entirely, but the V shaped channel bore improves speed of water flow and promotes a degree of self cleansing. If there is a significant ground slope, for instance in excess of 2%, self cleansing could be achieved. We recommend any channel system is cleaned at least once a year to ensure optimum performance. Q9 ARE PRE SLOPED CHANNELS AVAILABLE WITHIN THE ACO MULTIDRAIN PPD RANGE? Answer: No, but pre sloped channels are available within the ACO MultiDrain MD range. Q HOW DO I MAKE THE ACO MULTIDRAIN PPD SYSTEM WATER TIGHT? Answer: Instructions are provide in the ACO MultiDrain PPD Installation manual. This brochure is available to download from www.aco.uk or contact marketing@aco.co.uk to request your copy. Q ARE RECYCLED MATERIALS USED IN THE PRODUCTION OF ACO MULTIDRAIN PPD? Answer:, ACO MultiDrain PPD channels are manufactured using recycled polypropylene. All other components within the range also contain recycled materials. For more information on the recycled content, see opposite.

Model specification clause The surface drainage system shall be ACO MultiDrain PPD system as supplied by ACO Technologies plc; all materials and components within the scope of this system shall be obtained from this manufacturer. The system shall be CE marked and fully compliant with BS EN 433:2002, certified to Load Class (*). A declaration of conformity shall be supplied to the Supervising Officer upon request. All units shall be manufactured from recycled polypropylene with galvanised steel edge rails. The grating shall be BS EN 433: 2002 marked and tested to Load Class (*). The system shall be installed in accordance with the manufacturer s printed recommendations, and the work carried out as specified on the Supervising Officer s drawing no. ( ) and in accordance with recognised good practice. Standards of workmanship shall generally be as specified in BS EN 752 and BS 8000:Part 4:989. * insert information A 5, C 250 or D 400 as appropriate Please insert drawing number relevant to the project NBS Specifications ACO MultiDrain PPD should be specified in section Q:80. Assistance in completing this clause can be found in the ACO Drain entry in NBS Plus, or please contact the ACO Water Management Design Services Team. Note: A specification in NBS format is available to download from www.thenbs.com or www.aco.co.uk. Recycled content ACO Technologies aims to incorporate as much recycled material or waste material as is practicable in its manufactured products. Typically, cast iron materials contain 40% to 90% recycled iron, and steel products contain 25% to 33% recycled steel. The total recycled content of the ACO MultiDrain PPD system will vary as the proportion of different materials (in the channel, edge rails, gratings etc) varies. As an example the ACO MultiDrain PPD channel with Heelguard ductile iron gratings will contain at minimum approximately 35% by weight recycled material. The ACO MultiDrain PPD products are themselves intended for a long life with low maintenance, to reduce the need to recycle, but when eventually they are no longer needed, much of their content can be readily recycled with a very low risk of pollution to the environment. 35 Conformity The ACO MultiDrain PPD system is CE marked and fully certified to BS EN 433:2002. Test certificates and a declaration of conformity are available on request. Please contact the ACO Water Management Design Services Team on 0462 86666 for further information. BS EN 433:2002