Compact Slide Series ø, ø, ø, ø The use of an endless track linear guide produces a table cylinder having excellent rigidity, linearity and non-rotating accuracy. Endless track linear guide Series Variations Model Bore size (mm) Standard stroke (mm) Made to Order -XB3 : Low-speed cylinder ( to mm/s) -XC3 : Special port positions -XC9 : Intermediate stroke (Spacer type) -XC22 : Fluororubber seals -XC79 : Tapped hole, drilled hole, pinned hole machined additionally D- -X -X
The use of an endless track linear guide having excellent rigidity, linearity, Compact Slide Series Improved moment tolerance Allowable moment is approximately times greater than the series. Long strokes up to mm are now standard. Traveling parallelism Stroke (mm) to to. mm or less. mm or less Mounting is possible from directions. Lateral mounting (through holes) Lateral mounting (tapped holes) Piping is possible from 3 directions. IN OUT OUT port Vertical mounting (tapped holes) Axial mounting (tapped holes) OUT port (On both sides) IN port (On both sides) IN port If changing the port positions, a made-to-order part number, -XC3, is available.
produces a table cylinder non-rotating accuracy. / ø, ø, ø, ø Applicable example A table cylinder suitable for short pitch mounting Lateral mounting (Body through-hole) Transferring component parts Lateral mounting (Body tapped) Precision adsorption Axial mounting (Body tapped) Positioning pin Auto switches offer numerous variations. Reed switches, solid state switches and 2-color indicator type solid state switches can be mounted. D- -X -X 7
Series Model Selection Caution Confirmation of theoretical output is required separately. Refer to Theoretical Output on page 2. Selection Conditions: Follow the tables below in order to determine selection conditions and choose one selection graph. Vertical Horizontal l : Load eccentricity Mounting orientation m m L L Maximum speed (mm/s) Load eccentricity (l mm) Selection graph Up to () Up to (2) Up to (3) () Up to () () (7) Up to (8) (9) () Up to () (2) L: Overhang (the distance from the cylinder shaft center to the load center of gravity) The direction of L can also be a diagonal direction. (See the drawing at right.) L Selection Graph () to (3) (Vertical Mounting) Cylinder shaft center m Load center of gravity Graph () Maximum Speed (mm/s) or Less Graph (3) Maximum Speed (mm/s) or Less ø ø.. ø ø ø ø ø. ø 8 Overhang L (mm). Overhang L (mm) 8 Graph (2) Maximum Speed (mm/s) or Less. ø ø ø ø. Overhang L (mm) 8 8
Compact Slide Series Selection Graph () to (2) (Horizontal Mounting) Maximum Speed mm/s or Less Maximum Speed mm/s or Less Maximum Speed mm/s or Less Graph () Load Eccentricity mm Graph (7) Load Eccentricity mm Graph () Load Eccentricity mm ø ø... 8 8 8 Overhang L (mm) Overhang L (mm) Overhang L (mm) ø ø ø ø ø ø ø. 8 Overhang L (mm). Graph () Load Eccentricity mm Graph (8) Load Eccentricity mm Graph () Load Eccentricity mm. ø ø ø. 8 Overhang L (mm) ø ø ø ø..... 8 Overhang L (mm) ø ø ø ø ø ø ø ø Graph () Load Eccentricity mm Graph (9) Load Eccentricity mm Graph (2) Load Eccentricity mm ø ø ø. ø. ø.. 8 8. 8 Overhang L (mm) Overhang L (mm) Overhang L (mm) ø ø ø.. ø ø ø ø Selection Example. Selection conditions Mounting: Vertical Max. speed: mm/s Overhang: mm Load mass:. kg 2. Selection conditions Refer to Graph (3) based on vertical mounting and a speed of mm/s. In Graph (3), find the intersection of a mm overhang and load mass of. kg, which results in a determination of ø. Mounting: Horizontal Max. speed: mm/s Load eccentricity: mm Overhang: mm Load mass:. kg Refer to Graph () based on horizontal mounting, a speed of mm/s and load eccentricity of mm. In Graph (), find the intersection of a mm overhang and load mass of. kg, which results in a determination of ø. 9 D- -X -X
Compact Slide Series ø, ø, ø, ø How to Order M9BW Compact slide Made to Order *Refer to page 2 for details. Bore size mm mm mm mm Auto switch Nil Number of auto switches Nil S 2 pcs. pc. Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below. Cylinder stroke (mm) Refer to Standard Stroke on the next page. Applicable Auto Switches/Refer to pages 79 to 827 for further information on auto switches. Type Solid state switch Reed switch Special function Diagnostic indication (2-color indication) Electrical entry Grommet Grommet Lead wire length symbols:. m Nil (Example) M9NW m M (Example) M9NWM 3 m L (Example) M9NWL m Z (Example) M9NWZ Wiring Load voltage (Output) DC AC 3-wire (NPN) 3-wire (PNP) V, 2 V 2-wire 2 V 2 V 3-wire (NPN) V, 2 V 3-wire (PNP) 2-wire 2 V 3-wire (NPN equivalent) 2-wire 2 V V 2 V Refer to page 29 for applicable auto switches other than listed above. For details about auto switches with pre-wired connector, refer to pages 78 and 78. Auto switches are shipped together (not assembled). Indicator light Yes Yes No V V or less Auto switch model Perpendicular In-line M9NV M9N M9PV M9P M9BV M9B M9NWV M9NW M9PWV M9PW M9BWV M9BW A9V A9 A93V A93 A9V A9 Lead wire length (m). 3 (Nil) (M) (L) (Z) Pre-wired connector Solid state auto switches marked with are produced upon receipt of order. Applicable load IC circuit IC circuit IC circuit IC circuit Relay, PLC Relay, PLC
Compact Slide Series Specifications Bore size (mm) Guide rail width (mm) 7 9 2 Fluid Air Action Double acting Piping port size Minimum operating pressure Maximum operating pressure M x.8. MPa. MPa. MPa.7 MPa Proof pressure Ambient and fluid temperature Piston speed Allowable kinetic energy (J). MPa Without auto switch: to 7 C (No freezing) With auto switch: to C (No freezing) to mm/s.... Lubrication Cushion Non-lube Rubber bumper on both ends Made to Order (Refer to pages 87, and 8 to 9 for details.) Stroke length tolerance Auto switch (Option) Standard Stroke +. Reed auto switch: D-A9 Solid state auto switch: D-M9, D-M9W Symbol -XB3 Specifications Low-speed cylinder ( to mm/s) Bore size (mm) Standard stroke (mm) -XC3 Special port positions,,,,,,,,,,, -XC9 Intermediate stroke (Spacer type) Note: Intermediate strokes are available with Made to Order models (-XC9). (For details, see page 9.) -XC22 -XC79 Fluororubber seals Tapped hole, drilled hole, pinned hole machined additionally Theoretical Output (N) Bore size (mm) Rod size (mm) Operating direction Piston area (mm 2 ) Operating pressure (MPa).3..7 3 OUT IN 28.3 2.2 8.9.3.2. 9.8.8 OUT IN 78.. 23. 9.8 39.3 33...2 OUT IN 72.3. 8. 2 8 OUT IN 3 2 9.2 79.2 7 32 2 8 Mass (g) Model Stroke (mm) 2 7 2 37 7 227 7 27 8 8 8 8 9 2 279 2 9 7 29 92 323 97 2 33 238 38 7 D- -X -X 2
Series Table Displacement Table Displacement due to Pitch Moment Table displacement (arrow) when a load acts upon the section marked with the arrow at the full stroke of the compact slide F Table Displacement due to Yaw Moment Table displacement (arrow) when a load acts upon the section marked with the arrow at the full stroke of the compact slide F Mp My.2.8...2..8...2.,,, Stroke..2..8...2.2.3. Pitch moment Mp (N m)..2.3. Yaw moment My (N m),,, Stroke.3..2...,,, Stroke.3..2...,,, Stroke.3..2....2...8. Pitch moment Mp (N m)... 2. Pitch moment Mp (N m).3.3..2.,,,..... 2. 2. 3. 3. Pitch moment Mp (N m) Stroke Stroke. Selection of a bore size cannot be made only with above graphs. Select a bore size in accordance with Model Selection on page 8 and 9. 2. Displacement may increase after an impact load has been applied. When the table is subjected to an impact load, there may be permanent distortion of the guide unit and increased displacement. 22 Caution Caution on Design,,,...2..8...2..2....2.3...8 Yaw moment My (N m)..9.2. Yaw moment My (N m).. 2. 2. Yaw moment My (N m),,,,,, Stroke Stroke
Compact Slide Series Table Displacement Table Accuracy Table Displacement due to Roll Moment Table displacement (at A) when a load acts upon section F at the full stroke of the compact slide F Traveling parallelism to. mm or less Stroke (st) to. mm or less Mr..3.3..2....2.. Roll moment Mr (N m).9.8.7....3.2..2...8..2. Roll moment Mr (N m) A Model Allowable moment (N m) Pitch moment Mp.7.9.88 3. Yaw moment My.39.82.9 2.7 Roll moment Mr.9.37 2.7.9....3.2.... 2. 2. 3. Roll moment Mr (N m)..9.8.7....3.2..7. 2. 3. 3.7.. Roll moment Mr (N m) D- -X -X 23
Series Construction (ø) (ø) @ y @!7 w q!9 t!8 i! @ y @! w q!9 t!8! i!! r! @2 u o!3 @ e! r u @2 @3!3 @ e!2 / (ø, ø) @ y @!7 w q!9 t!8 i!! r u @2 @3!3 @ e!2 Component Parts No. Description Material Note Cylinder tube Aluminum alloy Hard anodized 2 Rod cover Brass Brass ø, ø electroless nickel plated 3 Head cover Aluminum alloy ø, ø chromated Piston rod Stainless steel Linear guide Table Aluminum alloy Hard anodized Brass ø, ø 7 Piston Aluminum alloy ø, ø ø, ø nickel plated 8 Magnet Synthetic rubber ø, ø 9 Magnet holder Brass ø High carbon chrome Steel ball A bearing steel Steel ball B High carbon chrome bearing steel Note: The series cannot be disassembled. Component Parts No. Description 2 C-type retaining ring for hole 3 Bumper Bumper Seal retainer Round head Phillips screw Hexagon socket head 7 cap screw 8 9 2 22 23 2 Hexagon socket head cap screw Hexagon socket head plug Nut Rod seal Piston seal Piston gasket Gasket Material Carbon tool steel Urethane Urethane Stainless steel Carbon steel Chromium molybdenum steel Chromium molybdenum steel Chromium molybdenum steel Brass NBR NBR NBR NBR Note ø, ø, ø ø ø black zinc chromated ø, ø, ø nickel plated Nickel plated Nickel plated Nickel plated ø, ø, ø 2
Compact Slide Series Dimensions: ø LT 9 8 LA LB J x M3 x. Depth. x M3 x. Depth. 7. 3 x M x.7 through Bottom hole dia ø3.3 x ø counterbore depth 3.3 Plug for port (Hexagon socket head set screw) x M x.8 x l x M3 x. Depth.8 Guide rail width 2 x M x.8 38 39 9. NS 8. 3 + Stroke 39. + Stroke 8 9 8 9... + Stroke x M3 x. Depth.8 Stroke (mm) J LA LB LT 2 2 2 2 2 2 72 82 92 NS 2 2 D- -X -X
Series Dimensions: ø LT 9 LA LB J x M x.7 Depth 8 x M x.7 Depth 7. 3 x M x.8 through Bottom hole dia ø.3 x ø7. counterbore depth. Plug for port (Hexagon socket head set screw) x M x.8 x l x M x.7 Depth Guide rail width 7 2 x M x.8 8 2. 7 3 23 8 7.. 2 NS 3 + Stroke. + Stroke + Stroke 2. x M x.7 Depth. 23 3. Stroke (mm) J LA LB LT 9 9 9 9 9 9 79 89 99 NS 2 2 2
Compact Slide Series Dimensions: ø LT 2 LA LB J x M x.7 Depth 9 x M x.7 Depth 3 x M x.8 through Bottom hole dia ø.3 x ø7. counterbore depth. 2. 9 Plug for port (Hexagon socket head set screw) x M x.8 x l x M x.7 Depth Guide rail width 9 2 x M x.8 2 2. 3. 27 27.... 7 NS 2. 7 2 + Stroke + Stroke 2 + Stroke x M x.7 Depth Stroke (mm) J LA LB LT 8 8 8 8 78 78 88 98 8 NS D- -X -X 27
Series Dimensions: ø LT 3 LA LB J x M x.8 Depth 9. x M x.8 Depth 3 x M x. through Bottom hole dia ø. x ø9.3 counterbore depth 8 Plug for port (Hexagon socket head set screw) x M x.8 x l x M x.8 depth 8 Guide rail width 2 2 x M x.8 7 7 3 3 32 3 32 3.. 2. 9. 32 NS. 2. + Stroke 8 + Stroke + Stroke x M x.8 depth 8 Stroke (mm) J LA LB LT 7 7 8 8 9 NS 7 7 28
Compact Slide Series Minimum Stroke for Auto Switch Mounting No. of auto switches mounted pc. 2 pcs. Auto Switch Proper Mounting Position (Detection at Stroke End) and Its Mounting Height D-A9 D-M9 D-M9W A D-A9 D-A9V 22 (2.) Applicable auto switch model D-M9 D-M9V D-M9W D-M9WV (mm) ( ): denotes the values of D-A93. D-A9V D-M9V D-M9WV A (22) W B ( ): denotes the values of D-A9V. W B 7. () Bore size D-A9, D-A9V D-M9W, D-M9 D-M9WV, D-M9V (mm) A W B A W B A W B 2.. 8. 2. 3. () 2. (.) 2. (.). ( 2) 3..... 22.. 7. 2. 2.. 2. 7. 8.... 22... 2. 2. 7. 8.. Note ) Negative figures in the table W indicate an auto switch is mounted inward from the edge of the cylinder body. Note 2) In the case of models with and strokes, the switch may not turn off due to operating range or two switches may turn on simultaneously. Fix switches outside to mm further than the values in the above table. (if switch is used, make sure that it turns ON and OFF properly; if 2 switches are used, make sure that both switches turn ON.) Note 3) ( ) in column W denotes the dimensions of D-A93. (mm) Operating Range Auto switch model D-A9, A9V D-M9, M9V D-M9W, M9WV Bore size 9 3 (mm) Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately ±% dispersion.) There may be the case it will vary substantially depending on an ambient environment. 3. Besides the models listed in How to Order, the following auto switches are applicable. Normally closed (NC = b contact) solid state auto switches (D-F9G/F9H types) are also available. Refer to page 7 for details. D- -X -X 29
Series Auto Switch Mounting Watchmaker, s screwdriver Auto switch mounting screw Auto switch groove position Auto switch When tightening the auto switch mounting screw, use a watchmaker s screwdriver with a handle to mm in diameter. Tightening Torque of Auto Switch Mounting Screw Auto switch model Tightening torque D-A9(V). to. D-M9(V). to. D-M9W(V) (N m) Note) When used with side piping, it is not possible to mount a D-A9V, M9V auto switch type on the side to which the piping is connected. x ø.2 Auto switch mounting groove Bore size (mm) A 9 2 (mm) B.9 8.8 3.7 7. B A
Series Specific Product Precautions Be sure to read before handling. Refer to front matters 2 and 3 for Safety Instructions and pages 3 to for Actuator and Auto Switch Precautions. Caution on Handling Auto Switches When installing in close proximity to each other Caution. When compact slide cylinders equipped with D-A9 or D-M9 auto switches are used, the auto switches could activate unintentionally if the installed distance is less than the dimension shown in Table (). Therefore, make sure to provide at least this much clearance. Due to unavoidable circumstances, if they must be used with less distance than the dimensions given in the table below, the cylinders must be shielded. Therefore, affix a steel plate or a magnetic shielding plate (MU-S) to the area on the cylinder that corresponds to the adjacent auto switch. (Please contact SMC for details.) The auto switch could activate unintentionally if a shielding plate is not used. Table () Bore size (mm) Dimensions of shielding plate (MU-S) that is sold separately are indicated as reference. Material: Ferrite stainless steel, Thickness:.3 mm Since the back side is treated with adhesive, it is possible to attach to the cylinder. Operating Precautions Caution d 3 (mm) L 2 3 7. Do not place your fingers in the clearance between the non-rotating plate and the cylinder tube. Your fingers could get caught between the table and the cylinder tube when the piston rod retracts. If fingers are caught in a cylinder, there is a danger of injury due to the strong cylinder output, and therefore caution must be exercised. 2. In terms of the load mass and moment, the cylinder must be operated below the maximum load mass and allowable moment. 3. If the output of the compact slide is applied directly to the table, make sure it is applied along the rod axial line. (Refer to the figure below.) 8 d L Operating Direction with Different Pressure Ports Caution. The compact slide can be mounted in three directions. Check the pressure port and the operating direction. (Refer to the figure below.) OUT OUT port (On both sides) IN port (On both sides) Stroke Direction Backlash Caution Since the connection between the piston rod and table is a floating structure, there is a maximum table backlash of. mm in the stroke direction. (Refer to the figure below.) IN IN port When customers change the port location, please order the plugs listed below. Replacement plug part no.: CXS-8-2877A Table Max.. mm Piston rod Piston rod and table connection OUT port. Make sure to connect a speed controller and adjust it to a speed of mm/s or less to operate the cylinder. 3 D- -X -X
Series Specific Product Precautions 2 Be sure to read before handling. Refer to front matters 2 and 3 for Safety Instructions and pages 3 to for Actuator and Auto Switch Precautions. Caution Mounting. When tightening threads for compact slide, properly tighten within the specified torque. How to Mount a Compact Slide A compact slide can be mounted from directions. Make a selection suitable for the applicable machinery and workpieces, etc. Lateral Mounting (Body through-hole) Lateral Mounting (Body tapped) Model Bolt M3 x. M x.7 M x.7 M x.8 Maximum tightening torque (N m). 2. 2.. l 2.7.. 2. Model Bolt M x.7 M x.8 M x.8 M x Maximum tightening torque (N m) 2... 8. l 2.7.. 2. l 9..2.2. Vertical Mounting (Body tapped) Axial Mounting (Body tapped) Model Bolt M3 x. M x.7 M x.7 M x.8 Maximum tightening torque (N m). 2. 2.. l.8 8 Model Bolt M3 x. M x.7 M x.7 M x.8 Maximum tightening torque (N m). 2. 2.. l.8 8 32
Series Specific Product Precautions 3 Be sure to read before handling. Refer to front matters 2 and 3 for Safety Instructions and pages 3 to for Actuator and Auto Switch Precautions. Caution Front Mounting Mounting. When tightening threads for compact slide, properly tighten within the specified torque. 2. When mounting a workpiece on the top of the table, do not screw a bolt in more deeper than the female thread (Below table l dimension). If screwing a bolt in more deeper than the l dimension, the edge of the bolt could reach the linear guide and might damage the linear guide. How to Mount a Workpiece A compact slide can be mounted from 2 directions. Make a selection suitable for the applicable machinery and workpieces, etc. Top Mounting Model Bolt M3 x. M x.7 M x.7 M x.8 Maximum tightening torque (N m). 2. 2.. l. 7. Model Bolt M3 x. M x.7 M x.7 M x.8 Maximum tightening torque (N m). 2. 2.. l. 8 9 9. How to Mount a Workpiece Workpieces can be mounted on 2 surfaces of the compact slide. Since the table is supported by the linear guide, take care not to apply strong impact or large moment, etc. when mounting workpieces. Hold the table when fastening workpieces to it with bolts, etc. If the body is held while tightening bolts, etc., the guide section will be subjected to a large moment, and there may be a loss of precision. D- For connection with a load having an external support/guide mechanism, select an appropriate connection method and perform careful alignment. Use caution, as scratches or nicks, etc. on the sliding parts of the piston rod can cause malfunction and air leakage. -X -X 33