Thermal-cutoff, Fuse and Fuseholder Incorporated into a Simple Compact Device

Similar documents
DATA SHEET FUSIBLE ALLOY THERMAL SENSITIVE PELLET TYPE, 2 AMPERES RATED CURRENT

DATA SHEET ORGANIC THERMAL SENSITIVE PELLET TYPE 10 AMPERES RATED CURRENT

MAGNETIC MOTOR STARTERS

HEAVY DUTY POWER RELAYS FEATURES

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Power systems Protection course

Ihr autorisierter Distributor: Neumüller Elektronik GmbH Motor Protectors

ELECTRIC POWER AND HOUSEHOLD CIRCUITS

Electrical Protection

Fusing Equipment. Kearney Fuse Links. general. Internal Construction. tin element

MICROTEMP Thermal Fuses. Product Information and Application Notes

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

9. Effects of an electric current

RP Instruction Manual

TCO Series Standard Styles

INTRODUCTION. MICROTEMP Thermal Cutoffs: Upper Limit Temperature Protection. Operating Principle of the MICROTEMP TCO

Is Your Wiring System Safe and Energy Efficient?

Metal Film Fuse Resistors

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

EVS RP6020. Instruction Manual

PB-Series. GFCI/ELCI & Panel Seal

HV DIN FUSE-LINKS FOR TRANSFORMER PROTECTION. March 2017

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

Kearney fuse links. Technical Data General. Effective December 2013 Supersedes November 2009

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

FUSES. Safety through quality

Input voltage Power rating Output voltage Output current With Front mounting Bracket. With DIN-rail mounting Bracket 400/480 VAC

Kearney fuse links. Technical Data General. Effective March 2014 Supersedes December 2013

FUSE TECHNOLOGY Ambient temperature

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

MICROTEMP Thermal Cutoffs PRODUCT CATALOG

PROTECTION OF THE BRANCH CIRCUIT

Products :: Circuit Protection :: Thermal Circuit Breakers

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Tablet PC Automotive applications Printer Security systems VOP (V) Ibreak (A)

Ratings 0402 inch size : Type ERBRD ERBRD R X 0R25 0R3 0R37 0R50 0R75 R00 R25 R50 2R00 2R50 3R00 Rated Current (A)

TECHNICAL SPECIFICATION OF THERMAL PROTECTOR, ST-22

EPS/ELA-Series User Manual EPS/ELA 250W

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

ECET Distribution System Protection. Overcurrent Protection

RT Series Step Down Transformer for RT Series UPS 6-10kVA UL Input Vac Output Vac User Guide

Model Number Structure

INTERACTIVE SCIENCE 2A

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

Medium voltage products. Fuses

OWNER S MANUAL POWER INVERTER

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

SEFUSE. Thermal Links

A1P OPERATING MANUAL

AF40... AF96 3-pole contactors Technical data

Industrial Control Transformers

Question 2: Around the bar magnet draw its magnetic fields. Answer:

New Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home

Design Standards NEMA

Technical Guide for Basic Switches

High Frequency SineWave Guardian TM

MICROTEMP Thermal Cutoffs: INTRODUCTION

PI Electrical Equipment - Course PI 30.2 FUSES

LS200 Series Instruction Manual

Thermal Cutoffs (TCO)/ Thermal-Links

PD-Series Ground Fault Circuit Protection

INDUSTRIAL POWER SUPPLIES SFL-SERIES

A Special Note To Our Customers

Thermal system protection of switchgear through high voltage fuse links with integrated temperature limiter under consideration of IEC 420:1990

RWS50B RWS100B RWS150B RWS300B RWS600B

Why is the Breaker Tripping?

Film Capacitors Power Factor Correction

Overcurrent Protection According to the 2011 NEC

WHITE PAPER. DIRTY DOZEN: The 12 Most Common Mistakes of Specifying Circuit Protection for Equipment. E-T-A Circuit Breakers

Technical Service Bulletin IOX/DCX Transmitter Maintenance Schedule

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

RU BMS Power Supply and Battery Management System Owners Guide

What is included in a circuit diagram?

Film Capacitors Power Factor Correction

1-50 KVA SINGLE-PHASE SERVO REGULATOR INSTRUCTIONS FOR USE SERVO SINGLE-PHASE VOLTAGE REGULATOR

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

General safety and installation information.

Car Battery Charger Instructions for Use

SEFUSE SEFUSE SEFUSER THERMAL CUTOFF NEC SCHOTT

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

Medium Voltage current limiting Fuse links

MASTERsine Inverter PXA Series Installation Guide

OD10 10A Outdoor Solar Charge Controller

ECET Circuit Design Motor Loads. Branch Circuits. Article 210

Design Guide. VLT Soft Start Controller MCD 100

Control Circuit Protection

Owner s Manual. DC-DC Step Down Converter

ATD WATT INVERTER

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

Utilization of Electric Power Laboratory 3 rd Year G2: Testing & Characteristic of MCCB Used in Commercial and Industrial Applications

Transfer switch OTEC open or delayed transition

Transcription:

Thermal-cutoff, Fuse and Fuseholder Incorporated into a Simple Compact Device It is generally known to employ a fuse for overcurrent protection and a thermal fuse or a thermostat for overheat protection individually in a circuit. Efforts have been made to combine a thermal fuse with a current fuse. Basically, the fuse must respond to joule heat generated by a current, while as the thermal fuse must not technology to meet both the basic characteristics contrary to each other. CT Fuse has been developed to overcome the thermal sensing element is isolated from the current carrying parts electrically and thermally which has attained the trust in the world. 5758 Foxbo ro Ave. NW ww w.calcoelectric.com

Fuse Revolution The First in the Protection Fields, Unique Design Change the Future of Circuit Protection. Applications It can be used as a device for overcurrent protection and for overheating protecting of electrical appliances and CT Fuses contribute to the as the composite devices which have both functions of fuse and thermal of circuit protection as the devices bring more safety to circuit. and others. E.g. microwave oven, rice cooker, coffee maker, bakery, dish washer, electric washer, vacuum cleaner, clothes dryer, fan heater, air conditioner, water warmer, vending machine, copy machine, computer, compressor, boiler, air oven, etc. Microwave Oven Copy Machine Electric Pot Fan Heater Highest Accuracy and Safety; Easy Installation and Economical Meets the Requirements of Various Safety Standards Complies with the requirements for fuses and thermal Pursuing Thoroughly Cost Performance on Electrical Circuits Three parts in one providing a substantial staving on parts cost by its multi-function. Current fuse and thermal cutoff are docked together. Furthermore a fuseholder is unnecessary. Saving in installation cost. The mounting and wiring cost for two parts is reduced in half. Additional processing is not required and usable as it is. Cost for additional insulation materials and mounting materials are not required. High Sensitive and High Accuracy Thermal Cutoff by Direct Mounting Method For a thermal sensing device, the response accuracy to an object temperature is more important than nominal temperature accuracy of itself because the real functioning temperature in actual operating condition is greatly affected by a current, temperature rise, and condition of convection or radiation. 5758 Foxbo ro Ave. NW ww w.calcoelectric.com

A Safety Device which Emphasizes on Reliability Provides a Sense of Security The organic materials which tend to deteriorate with age are not employed for the thermal element. The thermal element is made of stabilized metal alloy which has proved itself reliable in moisture, hot and cold conditions, in our DM Series thermal cutoffs. Furthermore, the thermal element is not deteriorated by the current passing through it because it is isolated from current carrying parts electrically and thermally. The current sensing element is silver coated against heat. It can be used even in a high ambient temperature. Insulation parts are made of molded PPS with high heat resistance, humidity resistance and high mechanical strength. Solid and Simple Structure Enables Easy Installation The installation is all accomplished just by mounting with screws and connecting with quick connectors. Any delicate handling is not required. Additional Protection of Function Improves the Safety of Equipment With its composite design, when a fuse is used only, the thermal cutoff function acts as a supplement and vice versa. More safety of equipment is obtainable at usual cost.

Dimension Thermal Fuses A Series UL Type, Medium acting fuse C Series UL Type, Semi-fast acting fuse D Series MITI Type, Medium acting fuse E Series MITI Type, Semi-fast acting fuse Thermal Rating Type Rating series according to the electrical characteristics of inner fuse. Note: The temperature ratings below are applicable to all series. Consisting of Type No A 15 080 V

A Series: Medium Acting Type (According to UL Standard) Current Carrying Capacity: 130% Blowing Current: 160% B Series: Arc Quenching Type (According to UL Standard) Current Carrying Capacity: 130% Blowing Current: 160% C Series: Semi-Fast Acting Type (According to UL Standard) Current Carrying Capacity: 110% Blowing Current: 135% D Series: Medium Acting Type (According to Japan MITI Standard) Current Carrying Capacity: 130% Blowing Current: 160% is 125V. Optional 250V type. E Series: Semi-Fast Acting Type (According to Japan MITI Standard) Current Carrying Capacity: 110% Blowing Current: 135% is 125V. Optional 250V type.

Principle of Operation Overcurrent Operation When an overcurrent larger than a predetermined value pass through the electrical circuit consisting of terminals (1) and fuse (10), fuse (10) blows to open the electrical circuit. Overheating operation When the thermal sensing face (8) is heated to a predetermined temperature, the thermal element (9) melts to allow the contacting spring (5) to expand. Consequently, the fuse (10) with the role of movable contact is separated from the terminals (1) by the working force of the interrupting spring (4) to open the electrical circuit. Construction It is designed that the ferrules of fuse (10) are pressed to the terminal ends cut in V-shape by the strong force of contacting spring (5). This contacting manner enables the contact of fuse to be kept stable for a long time as the contact resistance is very small compare to that of clip type. The transfer of joule heat from the current carrying parts to thermal element (9) is suppressed by the insulating cap (3). It is designed that the thermal element (9) is stuck together to the bottom of cover (8) thermal sensing face and its temperature is almost identical with that of the mounting surface. 1 2 10 7 6 8 4 3 5 9 1 Terminal 2 Casing 3 Insulating cap 4 Interrupting spring 5 contacting spring 6 Disk 7 Element housing 8 Cover 9 Thermal element 10 Current fuse

Overcurrent Blowing Characteristic Performance

Instruction Manual The following informations must be understood for the right selection and use of CT Fuse. For more details, refer to CT Fuse Instructions. Explanation of Ratings and Words are the same as on the ordinary current fuse and thermal cutoff and applicable to various safety standards. Thermal Rating Rated Functioning Temperature (TF) The upper limit of temperature at which a thermal cutoff functions with a detection current of 0.1A or less and temperature increasing at a rate of 0.25 to 1 C per minute. Note: Tolerance of functioning temperature is +0, -7 C. Rated Holding Temperature (TH) The ambient temperature at which a thermal cutoff does not function while conducting rated current for 168 hours. CSA. Maximum Temperature Limit (TM) The maximum temperature at which an opened thermal cutoff can be maintained for 10 minutes without its several safety standards such as IEC, UL, CSA. Electrical Rating Rated Voltage The maximum voltage at which a fuse can safely interrupt the rated interrupting current. A fuse can be used in a circuit of any voltage up to this. Rated Current The current which a fuse can be loaded to. For long life, a fuse is generally loaded to less than 75 90% of the rated current except in special case. Breaking Capacity The maximum short circuit current which a fuse can safely interrupt at the rated voltage.

Ambient Temperature and Operating Current Ambient temperature Generally the ambient temperature for the fuse test means the air temperature surrounding the fuse. The following understood for your circuit designing. Ambient temperature It is the air temperature including the heat generated by the current passing through fuse and conductor and it is measured at the position of 5cm to 15cm above the fuse. Mounting surface temperature It is the surface temperature of the fuse mounting plate excluding the joule heat generated by the current. It is usually higher than the ambient temperature. Thermal sensing face temperature It is the temperature of the bottom face of cover and is almost equal to the temperature of the thermal element. Type of Blowing Characteristics The following acting types are related to the blowing characteristics of CT composite fuse and not to the characteristics of inner fuse individually. Medium Acting Type At 25 C Current carrying capacity is 130% rating and blowing current is 160% rating. Semi-fact Acting Type At 25 C current carrying capacity is 110% rating and blowing current is 135% rating. Suitable for a circuit where a quick acting to the light overload is desirable. The operating current must be limited to a smaller current than that of the medium acting. Note: To the overcurrent of about 200% of rated current, each type blows instantaneously.

Safety Precautions on Operating Ambient Temperature Mounting Face Temperature and Thermal Sensing Face Temperature To avoid needless fuse blow and maintain the long life, the temperature of thermal sensing face including joule heat should not exceed TF - 15 C. If the thermal sensing face temperature is unknown, it is recommended that the mounting face temperature is limited to below TF - 25 C. Ambient Temperature TH is the allowable ambient temperature at 100% load of rated current. The life of this device is closely related to the ambient temperature as it is constructed to contain lower TH than that of ordinary thermal fuse to some extent. Refer to the next Safety Precautions on the Operating Current for the effect of ambient temperature on safety operating current. Temperature Limit in the Event of Overheating In any abnormal condition, but the mounting surface temperature and ambient temperature must not exceed TM (250 C) at the overshoot after open. Exposing to more than 250 C may cause the plastic parts to soften. Safety Precautions on the Operating Current It is generally known that the normal operating current should be limited to less than nominal rating and more derating is necessary in the ambient of higher temp for the long life of fuse. CT Fuses can be used in an ambient of higher temp because of the durable minded design. But considerable derating would be much desirable like ordinary fuses for the long life of fuse. The example of recommendable operating current is shown in the table. The deratings are various according to the surrounding conditions. For more details please consult with us. Mounting Ambient A, B, D Series C, E Series 130 C 110 C Rated current x 70% Rated current x 60% 110 C 90 C Rated current x 80% Rated current x 70% 90 C 70 C Rated current x 85% Rated current x 75%

Precautions in Installing and Connecting This device can be mounted irrespective of its attitude. This device is designed to sense the temperature of mounting surface. Mount this device with screws or the like so that the thermal sensing face bottom face of cover In case of other mounting methods, please consult with us. This device can be connected to wires by 6 35 x 0.8mm quick connect receptacles. In case of connecting by soldering its operation should be done within 10 seconds by 100W soldering iron. Poor crimp of connector or loose connection to the fuse terminal will shorten the life of fuse. under the connecting conditions by means of copper conductors in the table. If other conductors are connected they should be examined under the actual operating conditions since the electrical characteristics Ampere Rating to Wire Size 5-8A: 0.75 mm² (# 18AWG) 10A-15A: 1.25mm² (# 16AWG) 17AS: 2.0mm² (#14AWG) Selection of Fuse For the proper selection of the type or rating of CT Fuse, it is recommended to conduct a test on the fuse in the actual circuit under the normal as well as the abnormal operating conditions. (Refer to the special technical materials.) For obtaining the precise temperature sensing, it is recommended to use the thermocouples between the thermal sensing face of fuse and mounting surface to measure the normal or abnormal operating temperature. It is recommended to select the rating of fuses after checking the highest normal operating current, fault current and ambient temperature at the position within 15cm from the fuse terminal. It is recommended to check the operation fo thermal cutoff and the blowing of fuse as your intended circuit design. Consult with us regarding the starting inrush current or the details of the operating current and operating ambient temperature.