ENERGY. TECWATER EMV-FC S1BC4N8-F 0,6/1 kv. Screened Cable for Water Application

Similar documents
ENERGY. HYDROFIRM(T) EMV-FC S1BC4B-F 0,6/1 kv. Screened Cable for Drinking Water Application KTW/ACS

HYDROFIRM(T) S1BB-F and S1BBH2-F 0,6/1 kv. Round and Flat Cables for Drinking Water Application KTW/DVGW W270/ACS/WRAS ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU.../3E Medium Voltage Flexible Cables for Use in Water with Copper Core Shield sa B-CABLES nv ENERGY

sa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY

HYDROFIRM(T) KTW/W270/ACS S1BB-F and S1BBH2-F 0,6/1 kv Drinking Water Application

PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation

CORDAFLEX(SMK) (N)SHTÖU Tough Rubber-Sheathed Reeling Cables

ENERGY. TECSUN(PV) PV1 F Cables for Photovoltaics

Watertight Cable Catalogue. For drinking, waste and hot water application

ENERGY. TECSUN(PV) PV1-F Cables for Photovoltaics

(N)SSHÖU O/J, (N)SSHÖU 3E, (N)SSHÖU 3E + ST 0.6/1kV Cable

ENERGY. Solar Cables

Industry Cables Special cables for industrial applications General Catalogue

PROTOLON(FL)-LWL (N)TSFLCGEWOEU 3,6/6 kv: medium voltage flat reeling cable with fibre-optics

Global data. Electrical parameters

Technical attributes

INDEX PRODUCT RANGE TRATOSFLEX- NSHTÖU-JZ TRATOSFLEX- NSHTÖU-JZK TRATOSFLEX - NSHTÖU-J TRATOSFLEX- NSHTÖU-JK TRATOSFLEX-OCS NEW TRATOSFLEX-ES *

CRANE, CONVEYOR, LIFT & REELING CABLES

ÖLFLEX CLASSIC 110 CY

LISTED. Applications. Features CORDAFLEX (SM) CORDAFLEX (SM)

CABLES FOR A MOVING WORLD TRATOS VDE MTO. for Mining and Tunnelling Applications. May 2014 Tt 18-14

H05BQ-F / H07BQ-F. The harmonized PUR cable with Europe wide registration according to HD S1 VDE Description.

Conductor: plain wire, fine stranding as per VDE 0295 class 6 from 50 mm² fine stranding according to VDE 0295 class 5

RFOU 0.6/1kV Power Cable

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

2011 Ver Ph: Product Catalogue. Industrial Cables Hazardous area equipment Cable termination

BFOU 0.6/1kV Power Cable

ÖLFLEX CLASSIC 115 CY

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

20 HUBER+SUHNER RADOX SOLAR

RHEYFIRM (RTS) R-(N)TSCGEWTOEUS 3x...+3x.../3 3.6/6 kv 20/35 kv adapted to DIN VDE 0250 part 813

OFFSHORE WIND FEASIBILITY STUDY APPENDICES Appendix C.2 Subsea Cable Data Sheets

OPTOFLEX G62,5/125: rubber cables with fiber optic

PANZERFLEX TUNNELFLEX C A B L E S

Telephone Cables Fire Warning Cables

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

Rolling Stock Cables Supplement to Prysmian Group General Catalogue (CEE Region)

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

Caledonian Medium Voltage Cables Three Core Cables to VDE 0276-

SY PVC / BS EN Control Flexible Cable

MOTOR, SERVO, & FEEDBACK CABLES

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

Photo: HELUKABEL. Trailing Cables G 1

Data sheet chainflex CF6

Data sheet chainflex CF240

N2XY IEC XLPE PVC 0.6/1kV Cable

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

Solutions for the mining industry. Special cables for highest demands in the mining sector

Data sheet chainflex CF140.UL

Cables for Railway Technology

Caledonian Medium Voltage Cables

Caledonian Medium Voltage Cables

TECSUN (UL) PV1-F Halogen - free TÜV + UL dual rated PV-Wire

Composition of core 1. Conductor stranded tin plated copper 2. Insulation RADOX EI 110, colour: red 3. Sheath RADOX EI 109, colour: black

Data sheet chainflex CF8821

FTG10OM1-0,6/1KV. 50 N/mm 2 of copper section max for fixed layings

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall braid minimises electrical interference Multifunctional application possibilities

Cables for cable carriers and reels SYSTEMS IN MOTION

Crane Cables General Catalogue

DURAREEL TRAILING REELING CABLE

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

RG7H1R-1,8/3 26/45 kv RG7H1OR-1,8/3 18/30 kv

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING BLUELINE - CABLES FOR SHIPBUILDING.

INFORMATION. Hybrid cables. Description

Data sheet chainflex CF210.UL

VDE-registered oil-resistant PVC control cable with black outer sheath for a wide range of applications

TRATOS OIL&GAS NEK606

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

PRODUCT INFORMATION. UNITRONIC SPIRAL LiF2Y11Y. Info New: the unscreened spiral cables with small cross section High restoring forces PUR outer sheath

Any inquiries, please feel free to contact or Caledonian

Data sheet chainflex CFSOFT1

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Cable category. B Multi-core cables for domestic/handheld equipment Rubber insulation PVC insulation TPE insulation 0.

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

14 HH EAC/CTP CE RoHS-II conform

Unarmoured Single-Core Cables to BS6883

YOUR ENERGY, OUR SYSTEMS, ANYWHERE. Flexible Cables

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION

Data sheet chainflex CF10

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

Technical data sheet LÜTZE SUPERFLEX PLUS (C) PUR FEEDBACK Encoder cables for Siemens and other systems For highest requirements in drive technology

Cables for Airport Equipment

Technical Data Sheet Shielded (CY) PVC Control Cable

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR CLEAN ROOM TECHNOLOGY. industrieblick / Fotolia

High Voltage and Extra High Voltage Cables


Approvals (Norm references)

Power & Control Cable IEC

Data sheet chainflex CF881

Harnessing the wind of change. Our cables supply societies with renewable energy.

Rubber was the first insulant to be used in Electric Cable manufacture but gave way to other insulants like paper, PVC, XLPE etc.

Data sheet chainflex CF5

Data sheet CFBUS.PVC PVC - e-chain - Bus cable for medium load requirements (class 4.3.2): shielded, oil-resistant as well as flame-retardant.

BlueLine Cables for Shipbuilding

High Voltage Copper, Smooth Aluminum Shield/Sheath

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Transcription:

ENERGY TECWATER EMV-FC S1BC4N8-F 0,6/1 kv Screened Cable for Water Application

Technical Data Trademark Type designation Specification Application TECWATER EMV-FC S1BC4N8-F Design and tests according to Prysmian specification For making connections to electrical equipment used in a waste-water environment and subject to medium mechanical stress, e.g. submersible pumps in sewage disposal and treatment as well as submersible mixer. Especially for frequency converter controlled AC drives and if considerable demands in respect of electromagnetic compatibility (EMC) according to the EMC directive imposes. For an effective shielding both ends of cable must have a good shield contact to ground. Owing to the various (and frequently changing) substances of which the contaminated water is made up, the cables may be used only in easily accessible areas that can be inspected (installation depth of approximately 10 m, as customarily encountered in sewage water tanks). These cables are also suitable for use in process water, cooling water, mine surface water, rainwater and combined waste water. Under certain circumstances they can be suitable for groundwater and seawater; it is possible to impose less stringent specifications in terms of accessibility and inspection. In such cases the cables can be used at depths up to 500 m. If the water concerned is aggressive or composed of special substances, the cables resistance properties should be examined. These cables can be used indoors, outdoors, in explosion-hazard areas. In other respects, DIN VDE 0298-300 / HD 516 applies Electrical Rated voltage Maximum permissible operation voltage of plant and power system Maximum permissible peak AC voltage Û AC test voltage Uo/U = 0.6/1 kv - Single-phase and three-phase AC operation Line-Earth/ Line-Line 0.7/1.2 kv - DC operation Line-Earth/ Line-Line 0.9/1.8 kv 2,4 kv 5 kv (test duration 5 min.) Current-carrying capacity The s are valid for a cable in permanent operation with DC or AC with 50 up to 60 Hz in air at 30 C. In other respects, DIN VDE 0298-4 applies Thermal Maximum permissible operating temperature of the conductor Maximum permissible shortcircuit temperature at conductor Maximum permissible water temperature Minimum permissible temperatures during operation, laying, transportation and storage permanent 90 C 250 C (max. 5 s) 40 C (At higher water temperatures, a shortened cable service life is to be expected.) when in motion - 25 C when stationary - 40 C

Technical Data Mechanical Tensile strength Minimum bending radii max. 15 N/², see selection table See selection table Stability against other influences Water resistance Test according to DIN VDE 0282-16 (HD 22.16) Resistance to oil Test according to DIN EN 60811-2-1 Behaviour in case of fire Test according to DIN EN 60332-1-2

Design features Conductor Copper, plain, finely stranded Class 5 acording to DIN VDE 0295 / HD 383 / IEC 60228 Insulation Ozone, water and weather resistant insulation compound, base EPR (Ethylene-Propylene Rubber) Core identification Colour of cores according to DIN VDE 0293-308:2003 Sheath Shield 2 layer sheath system: Inner layer: EPR special compound; colour: blue Outer layer: CPE special compound; water and oil resistant; colour: black Braiding of tinned copper wires between inner and outer sheath. Maximum transfer impedance of 30 Ohm/km at 30 MHz Marking, example ~~"NNNNNNNN" ~~ TECWATER EMV-FC S1BC4N8-F 3x10/10KON 0,6/1 kv ~~ "NNNNNNNN" = Order number

Selection and ordering data Number of cores and nominal cross-sectional area ² Order-No. Conductor guidance Diameter over shield guidance Overall of cable Min. Overall of cable Max. Minimum bending radii (fixed installation) Minimum bending radii (free movement and entry) Approx. net weight for 1000 m kg Tension force Max. N Currentcarrying capacity, touching surfaces, at 30 C, 3 cores loaded A Short Circuit Current 1 s ka TECWATER EMV-FC S1BC4N8-F 3X1,5/1,5KON 5DH8 702 1,5 8,7 9,5 11,1 33 56 174 67 23 0,21 3X2,5/2,5KON 5DH8 703 2,0 9,7 10,5 12,1 48 73 230 112 30 0,36 3X4/4KON 5DH8 704 2,4 10,7 11,8 13,4 54 80 310 180 41 0,57 3X6/6KON 5DH8 705 2,9 12,2 13,6 15,2 61 91 389 270 53 0,86 3X10/10KON 5DH8 706 3,9 16,6 17,8 19,8 79 119 693 450 74 1,43 3X16/16KON 5DH8 707 5,0 19,4 20,9 22,9 92 137 1037 720 99 2,29 3X25+3G16/3 5DH8 708 6,3 24,5 25,3 28,3 113 170 1477 1125 131 3,58 3X35+3G16/3 5DH8 709 7,5 26,7 28,3 31,3 125 188 1883 1575 162 5,01 3X50+3G25/3 5DH8 710 8,9 31,0 33,2 36,2 145 217 2635 2250 202 7,15 3X70+3G35/3 5DH8 711 10,7 36,0 38,7 41,7 167 250 3633 3150 250 10,01 3X95+3G50/3 5DH8 712 12,3 41,5 43,7 47,7 191 286 4652 4275 301 13,59 3X120+3G70/3 5DH8 713 14,3 42,9 48,8 51,8 207 311 5933 5400 352 17,16 Technical data, dimension and weights are subject to change. PRYSMIAN Germany Version: 1.3 SL - Date: 2011-10-05