Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Similar documents
NTK floor twist outlet DB-N-DN 215

Broad multiplex outlet BF-V...

Krantz. Trapezoidal displacement outlet VA-T... Semi-trapezoidal displacement outlet VA-TH... Air distribution systems

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Ceiling swirl diffusers

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling swirl diffusers with perforated face plate

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Ceiling swirl diffusers

ISF-AD. Inclined Floor Swirl Diffuser PRODUCT BROCHURE. Optional Features: Constant throw height adjustable airflow rate Electrical VAV operation

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Ceiling swirl diffusers with perforated face plate

PRODUCT BROCHURE. Rectangular Displacement Diffuser RDW-FD RDW-FD : smartemp.com

STI Supply air valve. Specifications. Quick Selection. Product code example Supply air valve STI-160-C

ceiling swirl diffuser DQJ

Ceiling Swirl Diffuser DQJ

Slot diffusers, Round duct diffusers. IMP Klima

Ceiling swirl diffusers

ceiling swirl diffuser Model DQJA / DQJR

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Ceiling diffuser 4DE

PELICANTM. Wall. Rectangular perforated wall air diffusers for supply air. Quick guide

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Air Displacement Vent Units

SRY. Ceiling mounted linear disc diffuser for supply air QUICK FACTS

CornerAir. CornerAir. Active chilled beam

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

Displacement flow diffusers. L e

Ceiling diffuser 4DF

Ceiling Slot Diffuser DSC

1/8/EN/6. Floor Diffusers. Type FB. in aluminium and plastic

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Ventilation grilles for installation into walls, sills or rectangular

Ceiling impulse diffuser Model PIL

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Slot diffusers for ceiling installation

Ceiling Slot Diffuser DSC

Ceiling air diffuser INDULCLIP INDUDRALL KOMBICLIP

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

JVR CONTENTS. Page Introduction 2 Models and dimensions 3 Technical data. Selection tables 4 Technical data. Selection charts 5 Product codes 6

Ceiling Slot Diffuser DSC

Swirl Diffuser Model DQF

WGA Long throw nozzle grille

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

Swirl Diffuser DHV Contents Description...3 Models and dimensions...4 Technical data...8

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

1/3/EN/4. Ventilation Grilles Types TRS-K TRS-R TRSE-R

DIR. VARIZON Displacement unit with adjustable spread pattern. Quick guide

Ventilation grilles for installation into walls, sills or rectangular

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Ceiling Slot Diffuser Model DSX

Exhaust air diffuser HPKH + Plenum box ATTS

KSOF Fire damper valve

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

Floor Swirls Models BZD and SZD

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

C O L M A N. Air Distribution SWIRL DIFFUSERS DWT SERIES DWT SERIES

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Wall diffuser SVQC / Supply air unit SVQC + ATVA TECHNICAL DATA

IMP Klima. Swirl diffusers. Variable swirl diffusers

ACTIVENT System. Specifications. Product code example ACTA

KLIMA Active Chilled Beams

TUBUS TUBUS. Key figures. Function Wall-mounted supply air diffusers

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Long Throw Nozzle WDA

DCS - Ceiling Diffuser. Halton DCS. Ceiling Diffuser

C O L M A N. Air Distribution FLOOR SWIRL DIFFUSERS B SERIES SERIES

Air Distribution SWIRL DIFFUSERS DW SERIES SERIES

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

Multicore diffusers. introduction. type control. options. finish. sizes SQUARE AND RECTANGULAR DIFFUSERS

Ventilation grilles for installation into walls, sills or rectangular

KTS Supply air valve. Specifications. Quick Selection (50 Pa) Product code example Supply air valve KTS-100-C

Compact Grille Model KG

Ventiduct nozzle ducts

BRC

TBV - Terminal Unit. Halton TBV. Terminal Unit

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Air displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225

Ventilation grille Model AL

5/9.2/EN/6. Volume Flow Limiter. Type VFL for insertion into air ducting. The art of handling air

Ventilation grilles for installation into walls, sills or rectangular

DFB - Conical Ceiling Diffuser. Halton DFB. Conical Ceiling Diffuser

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

SLOT DIFFUSERS, ROUND DUCT DIFFUSERS

Mobile recleanable HEPA filter units for a flow of m 3 / h

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Ventilation Grille PA

Transcription:

Krantz Floor displacement outlet Q-B-DN 0 Air distribution systems DS 62 E 05.

Construction design Preliminary remarks Floor displacement outlets are usually used where wall or plinth displacement outlets cannot be installed for reasons of space and a raised floor is available. The Q-B-DN 0 floor displacement outlet is suitable for the relatively large volume flow rate range up to l/s [ m 3 /h]. The air outlet element is made of aluminium and is intended for installation in conventional raised floor systems. When the floor plan is altered the floor tiles with air outlets can be easily exchanged for tiles without air outlets. The local air supply to the room can therefore be increased or reduced as required. The supply air is fed to the floor displacement outlet via the distributor basket. The space under the raised floor acts as a pressurized plenum. The floor displacement outlet can also be connected to the supply air ductwork via a rectangular connection box with flexible duct. Construction design The Q-B-DN 0 floor displacement outlet consists of the circular air outlet element 1 with 16 outer air slots 1a and a perforated air outlet centre 1b. It can be inserted either in the stepped bore b or, using a clamp insert 5, in the through bore a of the floor tile. The clamp insert has a protective collar 6 on the top which functions as edging for the tile cutout. This is particularly useful for raised floors with carpeting. VL VSD VND Figure 1: Floor displacement outlet in a floor tile Left: in a stepped bore Right: in a through bore with clamp insert The clamp insert can be fastened to the floor tile with a claw fastener 5b or a clamp collar 5d. The air outlet element can be optionally locked to prevent unauthorized removal 1). The floor displacement outlet is supplied with a distributor basket 2 for even air supply. There are different types to choose from (Figure 2): Standard type, with throttle device: VSD (without throttle device: VS) Short type, for raised floors with lower plenums; without throttle device: VK Short type with fixed damper for even supply air distribution when using DN 0 in assembly rooms or with low air outlet volume flow rates: VL Low type, with openable basket bottom to enable additional air supply from below, best for raised floors with thicker tiles and lower plenums, with throttle device: VND (without throttle device: VN) Perforated sheet metal type for metal floor air outlets, with throttle device: VPD VK Figure 2: Various types of distributor basket Table 1: Technical data Air outlet volume flow rate V A: Nominal ø = Installation ø: Supply air temperature J su : Temperature difference between supply air and indoor air 2) DJ: supply air and return air 3) DJ: Coverage radius of a floor displacement outlet: Weight of air outlet: Breaking load ) of air outlet element: VPD l/s [ m 3 /h] DN 0 C 1 to K K 5 m 0.8 kg. kn 1) For the required air outlet type (kind, material, etc.) or possible combination of individual components, see Table 3 Types available on page 6 2) At head height of a seated person 3) For room heights up to approx. 3 m; otherwise higher DJ possible ) Load class to EN 1: Heavy ; point load applied centrally with steel cube, edge length x mm with corner radius min. 2 mm 5) The slide 8b is adjustable from the room Key for all pages: 1 Air outlet element 1a Air slots 1b Air outlet centre 2 Distributor basket 3 Throttle device Seal (by others) 5 Clamp insert 5b Claw fastener 5d Clamp collar 6 Protective collar Connection box 8 Connection spigot 8a V damper (optional) 8b Slide 5) Floor tile a Through bore b Stepped bore www.krantz.de DS 62 E p. 2 05. 2 Krantz

Installation options and dimensions min. ø 0 ø 5 ±1 1) ø 8 +0.5 1 1a 1b 6 a min. ø 0 ø 5 ±1 1) ø 8 +0.5 3 5 ø 5d 5 2 3 ø X 0 5d 5 2 X ø 3 DN 0 with clamp insert and clamp collar, VND distributor basket 52 8b 2) +0.2 ø 0 +0.3 ø 1.5 +0. b max. 5 8 8a DN 0 with clamp insert and clamp collar, VPD distributor basket 3 350 2 ø 1 ø 11 +1 Top view of connection box DN 0 installation in stepped bore, VK distributor basket 8b 2) +0.2 ø 0 +0.3 ø 1.5 +0. b max. 5 www.krantz.de DS 62 E p. 3 05. 0 0 8a min. ø 5b 5 3 2 ø 0 ø 1 ±1 1) ø 13 1 DN 0 with clamp insert and claw fastener, VSD distributor basket Y DN 0 Top view of installation in stepped bore ø 1 ø 11 +1 DN 0 installation in stepped bore, distributor basket VL 5d 1b Detail X 1 1a Detail Y 5b DN 0 - Top view of installation with clamp insert 6 1 1a Notes: Any distributor basket can be used for the respective installation options. Likewise connection box can be used for the air outlet placement in the other figures. 1b 1) ø 1 +1 for fastening with claw fastener, ø 5 +1 for fastening with clamp collar 2) The slide 8b is adjustable from the room Krantz 3

Mode of operation Mode of operation The supply air flows into the distributor basket and then through the radial air slots and the perforated air outlet centre into the room. The special shape of the slots deflects the air jets which slide along the floor (Figure 3). The result is a low-turbulence horizontal, radial supply air flow at low velocity. Height above air outlet in mm 500 0 0 < 0.1 in = C Volume flow rate V A = l/s [ m 3 /h] Supply air temperature su = C Indoor air temperature in = C Air velocity u in Turbulence intensity Ti in 0 0. 0.0 2 0.05 50 0. 2 0. 0.1 0 0 0 0 500 Figure 3: Floor displacement outlet, jet pattern Distance around the air outlet in mm Height above air outlet in mm 500 0 0 < 0.1 in = C Volume flow rate V A = l/s [ m 3 /h] Supply air temperature su = C Indoor air temperature in = C Air velocity u in Turbulence intensity Ti in Figure : Low-turbulence horizontal, radial jet dispersion, made visible with smoke tracer Figure 5 shows the air velocities measured in the near-zone of the air outlet for two air volume flow rates. Already at an approximate distance of 0.5 m from the air outlet they are low and allowable indoor air velocities to EN ISO are not exceeded. Despite the low air velocities, we recommend a minimum spacing of 0.8 m between air outlet and next seat. This prevents the seat from obstructing jet dispersion and possibly resulting in impaired thermal comfort for the occupants. 0 50 0. 0.53 0 0 0.11 0. 0. 0. Distance around the air outlet in mm Figure 5: Air velocities above the floor with different air outlet volume flow rates V A Above: V A = l/s [ m 3 /h] Below: V A = l/s [ m 3 /h] 5 0 0 500 1 2 www.krantz.de DS 62 E p. 05. Krantz

Sound power level and pressure drop Sound power level and pressure drop 1) Total pressure drop p t in Pa p t 6 3 + 5 + 8 2 + 6 1 2 + 3 1 5 + 6 + 8 8. 2 l/s L WA Sound power level L WA in db(a) ref. - W Table 2: Key to graphs No. Size Type 1 Distributor basket Throttle device 2) open Aperture width / Disc lift mm V damper in connection spigot Damper angle a 8 3) 2 DN 0 VSD 8 0 open 3 8 5 5.0 3) 5 50.5 3) 6 DN 0 VPD 5.0 0 open 50.5 0 open 8 5.0 5 DN 0 VL without throttle device 3) Left: Adjustment of throttle device in VSD distributor basket 50 0 0 m 3 /h Air outlet volume flow rate V A www.krantz.de DS 62 E p. 5 05. No. 1 2 3 5 6 8 Air outlet volume flow rate Size Total pressure drop Sound power level in db ref. - W V A Dp t L WA Octave band centre frequency in Hz l/s m 3 /h Pa db(a) 63 1 0 500 1 K 2 K K 8.5 11 35 1 2 11 16 11 16 1 2 16 38 3 3 38 2 35 2 2 35 1 3 Insertion loss in db 3 3 1 1 2 2 1 2 Octave band centre frequency in Hz 1 1 0 500 1 K 2 K K 8 K 11 Mean value DN 0 6 3 8 DN 0 8 Throttle device Aperture width Distributor basket Disc V damper Connection spigot Connection box Adjustment of throttle device (disc) in VPD distributor basket Figure 6: Adjustment of throttle device Slide V damper in connection spigot 0 mm = closed.5 mm = 50 open 5 mm = open 1) The sound power level and pressure drop pertain to the use of the VSD and VPD distributor baskets. When the VK and VND distributor baskets are used, the values approximate those for the VSD type or remain within the permissible measuring tolerances. 2) The throttle devices in the distributor baskets enable continuous volume flow reduction, preferably up to 50, as well as full shutoff 3) Without connection box Without connection box With connection box Krantz 5

Types available, features Table 3: Types available Floor displacement outlet Materials 1) Component PC Al St Air outlet element DN 0 For installation in through bore: Clamp insert with clamp collar SR with claw fastener SK For installation in through bore and stepped bore: Distributor basket Standard type VS with throttle device VSD Short type VK Short type with fixed damper VL Low type VN with throttle device VND 3) 3) Perforated sheet metal type with throttle device VPD Connection box without V damper in connection spigot with V damper in connection spigot 2) = available Figure 6: Floor displacement outlet Q-B-DN 0 Installation example: short distributor basket VK and floor tile with stepped bore Figure : Floor displacement outlet Q-B-DN 0 Installation example: perforated sheet metal distributor basket VPD with throttle device and floor tile with clamp insert in a through bore; below it, connection box for duct connection Features Suitable for displacement ventilation in commercial application Installation in conventional raised floor systems Air supply direct from the pressurized plenum or via connection box with flexible duct Low-turbulence horizontal, radial jet dispersion over the floor For air volume flow rates up to l/s [ m 3 /h] Coverage radius of to 5 m Temperature difference between: supply air and indoor air 1 to K supply air and return air K ) depending on heat load and room height Floor installation by insertion in a stepped bore or installation with clamp insert in a through bore of a floor tile Fastening of clamp insert to floor tile with clamp collar or claw fastener Air outlet element and clamp insert made of aluminium, connection box made of galvanized sheet metal Air outlet element can be optionally locked against unauthorized removal Distributor baskets made of polycarbonate or galvanized sheet metal, with or without throttle or shutoff device Can be walked over, driven over and can support a wheelchair 1) PC = polycarbonate; Al = aluminium; St = galvanized sheet metal 2) V damper not needed for distributor basket with throttle device 3) Lock is optional ) For room heights up to approx. 3 m; otherwise higher DJ possible www.krantz.de DS 62 E p. 6 05. 6 Krantz

Type code and tender text Type code Q-B DN 0 Damper (only for distributor baskets VS, VN and VP) O = no volume flow damper D = with throttle device Floor displacement outlet Size Distributor basket Damper Clamp insert Connection type Clamp insert SO = no clamp insert SK = claw fastener SR = clamp collar Connection type P = floor plenum K = connection box Distributor basket VS = standard type VK = short type VL = short type with fixed damper VN = low type VP = perforated sheet metal type www.krantz.de DS 62 E p. 05. Tender text 1)... units Floor displacement outlet for low-turbulence horizontal, radial supply air flow above the floor, for installation in floor tiles of conventional raised floor systems; the air outlet can be walked over, driven over and can support a wheelchair; load class to EN 1: Heavy ; consisting of: circular air outlet element with radial air slots and perforated air outlet centre, distributor basket in the following options: Standard type with surrounding slots in basket casing, optionally fitted with throttle device for full shutoff of air outlet. Short type with surrounding slots in basket casing, best for low raised floors, without throttle device. Short type with fixed damper for even supply air distribution when used in assembly rooms or with low air outlet volume flow rates. Low type with surrounding slots in basket casing and openable bottom, best for raised floors with thicker tiles and lower plenums, optionally fitted with throttle device. Perforated sheet metal type, for floor air outlets made of metal, including throttle device. optional clamp insert for installation in through bore of floor tile, fixed with clamp collar or claw fastener. optional connection box for direct connection of air outlet to a flexible duct, optionally fitted with volume flow damper adjustable from room. The air outlet element can be optionally locked against unauthorized removal. Material: Air outlet element made of aluminium in natural colour 2) Clamp insert made of aluminium in natural colour 2) Distributor basket made of galvanized sheet metal or polycarbonate Connection box made of galvanized sheet metal Make: Type: Subject to technical alterations. Krantz Q-B DN 0 1) For the required air outlet type (kind, material, etc.) or possible combination of individual components, see Table 3 Types available on page 6 2) Powder coating to RAL... on request Krantz

Krantz GmbH Uersfeld, 52 Aachen, Germany Phone: + 1 1-1 Fax: + 1 1-555 info@krantz.de www.krantz.de