EASY TO RUN. Road Mode Operation. Standby Mode Operation. Temperature Set-point. Defrost. Alarm display. Malfunction codes table. Unit Data.

Similar documents
PRELIMINARY UNIT OPERATION. Operation & Service Manual. Carrier Transicold Europe 03/09/07 Viento/Xarios/Zephyr - Unit operation Road only /Rev- #1/15

Constant Cold throughout the day PULSOR

Section 3 Technical Information

Our complete line of refrigeration systems and performance options. Truck/Trailer/rail Product guide

a s s e m b l y t o o l s a n d s y s t e m s Pneumatic Screwdrivers DS Series w w w. d o g a. f r

ACCESSORY KIT INSTALLATION INSTRUCTIONS

List price 2012 USD A Service manual, CA-UK B Service manual, CIM5-UK C Service manual, CIM6-UK 29.

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

Operator s Manual. TriPac EVOLUTION Diesel Particulate Filter (DPF) TK OP (Rev. 2, 03/16)

Operation & Service Manual INSTALLATION

ATA 49 AUXILIARY POWER UNIT

DASSAULT AVIATION Proprietary Data

Flight Systems. Replacement for KASSEC DESCRIPTION

ROC-2. icontrols. Reverse Osmosis System Controller Documentation

Starcool Reefer Parts Service Manual, CIM6, Spare part catalog Short Form manual, CIM6, ES. Back plate, evaporator

13A-1 FUEL CONTENTS MULTIPOINT FUEL INJECTION (MPI) FUEL SUPPLY... 13B



ASSEMBLY TOOLS AND SYSTEMS. DPTC Cordless Impulse tools

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

GENSET CONTROL MODULE LEVEL 0 A120A. User selectable time delays for engine start and engine stop (cool down).

Subject Underhood G System Error Codes and Symptoms System or Parts affected

3.2 Air Conditioning (A/C) Model 140 up to M.Y. 1995

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

4.2 Component Identification

Truck and Trailer Selection Guide

MATRIX LLC LEVEL CONTROL PANEL

PowerView PV380-R2 Mechanical Configuration

QUANTUM LX CONTROL PANEL

Terex Utilities. Issue: Action:

MICROPROCESSOR BASED CONTROLLER

Power (kva) 3 Phase,50 Hz, PF 0.8. STANDBY RATING (ESP) PRIME RATING (PRP) Standby Amper. kw kva kw kva 400/

Copeland Screw TM Compressors

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

SINAMICS GM150 IGCT version

Malfunction Criteria and Threshold Value Adaptive value. Secondary Parameters with Enable Conditions. >50.8 S Engine load 9-45% Delta fuel adaptation

E Series CE Approved Intermittent Pilot Ignition Control

ASSEMBLY TOOLS AND SYSTEMS. DPTC Cordless Impulse tools

Diesel Generator Set S3.8 Series Engine

SERVICE MANUAL HOT DELI 3/4/5/7 MERCHANDISERS

PART7. Trouble Shooting

SLAM-SHUT VALVE. Type OSE

Variable speed application guidelines

REPLACEMENT PARTS MANUAL

PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM

INSTALLATION INSTRUCTIONS Model FPT 50

9. Maintenance. 9.1 Error Code List. Service Manual. Installation and Maintenance

ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

Slam-Shut Valve OSE LS. Europe, Middle East, and Africa Document Only CONTENTS INTRODUCTION CHARACTERISTICS. Scope of Manual.

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

Service Manual. 9. Maintenance. 9.1 Precautions before Maintenance. discharge resistance or plug of soldering iron. Installation and Maintenance

VTZ variable speed Reciprocating compressors

CSD Series Current Devices Split Core

Fuses and Relays CONTENTS FUSE AND RELAY BOARDS ( ) K4M690-K4M694 ENGINES 13

EVD-ice FOR PS SERIES

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Air-Cooled Liquid Chiller with integrated hydraulic module

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

BITZER Liquid Injection Guidelines for CSH Compressors

P445 Series Electronic Lube Oil Control

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Instruction Bulletin. Enclosed ALTISTART 46 Controller Supplemental Instruction Bulletin Class 8638 and 8639 INTRODUCTION

ORDERING INFORMATION SPECIFICATIONS APPLICATION

GS2 Series - Introduction

Application Engineering

ECCII to ECCIII Upgrade Kit

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

SPN 609 or Suspect Parameter Number (SPN) and Failure Mode Indicator (FMI) Description

CWP-CO / CWP-RC / CWP-HP 02 to 35

TM-11x1 Series Room Temperature Module

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Wadi Mai Item Description Status UOM Quantity

Standby Amper VOLTAGE

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Battery, Mounting and Cables - Battery and Cables Description and Operation

HGM72 Automatic Generator Module OPERATING MANUAL Smartgen Electronic

ELECTRIC AND ELECTRONIC ACCESSORIES. motralec

Installation Instructions Part Numbers: CRLOWAMB018A00 THROUGH CRLOWAMB026A00

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

A/C SYSTEM SPECIFICATIONS

9-2 FAULT CODE DIAGNOSTICS AND REPAIR PROCEDURES

ROCKLEA TRUCK ELECTRICAL. Sleeper Air NXT. Owner s Manual. Revision th March 2013

DESCRIPTION AND OPERATION

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL - ICE0806A3-W3-R4, ICE1006A3-W3-R4 Includes 50Hz. and 3 Phase Units


Nordic Model CCM0830 1, Service Parts Manual (Includes 50Hz. Units)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

On Demand, Differential Pressure Controls

GENSET CONTROL MODULE A121A / A241A

HVAC Compressor Clutch Does Not Engage

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Powerful Solutions DHP - Introduction

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Standby Amper VOLTAGE

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

DIM Heating and Air Conditioning

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL: TCA100

SSW07. Soft Starters. Applications. Standard Features

Eaton Hybrid First Responder Training Eaton. All rights reserved.

Transcription:

RUN CHECK OUT THESE FUNCTIS Road Mode Operation Standby Mode Operation Temperature Setpoint CARRIER TRANSICOLD EUROPE S.C.S 0, bd de l Oise F950 CERGY PTOISE CEDEX Téléphone : + (0) 00 Fax : + (0) Defrost Alarm display Malfunction codes table Unit Data Stopping Brightness Display 500 SERVICE STATIS In EUROPE RUSSIA, MIDDLE EAST AND AFRICA Soucieux d'améliorer en permanence la qualité de nos produits, nous nous réservons le droit de modifier sans préavis nos fabrications. Carrier Transicold Europe S.C.S. S.C.S. au capital de 6090700 euros R.C.S. Pontoise B 0 0 776 Code APE 5 M TVA : FR500776 Les informations contenues dans ce document ne sont pas contractuelles, et ne peuvent être reproduites sans notre consentement préalable 6605790. 6605790

I FOR YOUR PROTECTI STOP Safety Your CARRIER product has been designed to meet all European Safety requirements. Please take notice of all stickers that have been placed on this product for your safety. They are for your PROTECTI. Stopping EMERGENCYSTOP ARRET D'URGENCE 0 In all cases the unit can be completely shut down manually by the emergency switch inside the frame of the condenser unit. The emergency switch has to be reinitiated to allow the unit to restart. Press the key Before welding on the chassis make sure to have disconnected battery VDC power supply and alternator. Never start the unit with a booster as it could damage electronic components. Notes: for a short stop, switch off the ignition key of the vehicle. Display brightness Beware of voltage Make sure unit is shutdown. Standby mode operation. FOR YOUR SAFETY : Never operate the Cab command while driving. Two display brightness are available. Press 5 seconds the + or key to adjust the brightness to your convenience. 0

READ KEYPAD Unit Data 5 6 7 9 Unit Data can be accessed by following the herebelow key sequence Press SET for 5 seconds to access malfunction codes list Press or + key to display malfunction codes Press SET displays software version Press + key displays cab command software version Press SET displays road hourmeter (Road light is illuminated) Press SET displays standby hourmeter (Standby light is illuminated Press Defrost key displays defrost interval calculated by the microprocessor Press Defrost key displays elapsed time since the last defrost Press SET key returns to box temperature display The cab command simplifies all control operations. From his seat, the driver can carry out: Automatic startup in Road or Standby mode Temperature Setpoint Parameters change Alarms display Defrost Shutdown The driver can display the box temperature, and see whether the setpoint is being maintained by checking the green indicator. The indicator lights up red in the events of a malfunction. 0 5 6 Readout Standby operation Engine operation Manual defrost key Data decrease Modified data selection 5 6 7 7 9 0 9 Data increase Unit shutdown Unit startup Unit operation display Green: off cycle Red: malfunction 9

START CHECK Road Mode Operation Malfunction codes table Start the vehicle engine Press the key The box temperature is displayed The Road Mode light illuminates Note: Startup is timedelayed for 0 seconds A00 A0 A0 A0 A0 A05 A06 A07 A0 A09 A0 A A A A A5 A6 A7 A A9 A0 A A A A A5 A6 A7 A No malfunction. Unit in operation Low pressure switch open High pressure switch open Standby compressor over heated Clutch compressor fault Contactor fault Condenser fan fault Evaporator fan fault Hot water solenoid fault Defrost valve (HGS) fault Liquid injection valve fault Hot gas valve (HGS) fault High temperature alarm Low temperature alarm Defrost alarm > 5 minutes Setpoint adjusted out of the range 9 C/+0 C Drain water resistor fault Thermal break down standby transformer or diode bridge protection fault Electrical heating relay fault Liquid solenoid valve fault LP standby pressure switch openend Open circuit contactor compressor Open circuit condenser fan Open circuit hot water solenoid Open circuit defrost valve (HGS) Open circuit liquid injection valve Open circuit hot gas valve (HGS) Open circuit drain water resistor (DWR) Open circuit electrical heating relay (EHR) Note: when a malfunction is past or repaired AXX becomes PXX

READ RUN Alarm display Standby Mode Operation Press SET for 5 seconds Connect standby cable to unit Press or + key displays malfunction codes Press SET key again to return to box temperature display Note: the following messages are displayed without action on cab command and instead of temperature readout as soo as the malfunction is detected and remain displayed as long as the malfunction persists. The unit shuts down until the malfunction has disappeared or been corrected. Malfunction: evaporator temperature probe Battery low voltage alarm Twin power supply (Diesel and Standby) Programming mistake of the maximum setpoint by the user Setpoint lower than maximum setpoint but in the range 9 C / +0 C Press the key The box temperature is displayed The Standby mode light illuminates Note: Startup is timedelayed for 0 seconds SAFETY PRECAUTI Under no circumstance the standby mode should be operated while the unit running on. The unit must be shutdown before connecting or disconnecting the standby supply cable. 7

SET SELECT Temperature Setpoint Defrost Press the SET key Press the Defrost key Change setpoint to desired value DF is displayed Note: the Defrost mode terminates automatically Press the SET key to enter new value Note: when no key is activated within 5 seconds, display reverts to box temperature. Defrost Parameters change Shut down the unit Press Defrost key and key Previous selected defrost interval is displayed Press or + key to increase or decrease defrost interval 5 Press SET key to enter new value Modification of defrost interval 00 : inhibit defrost function. 0,5 to 0,9 : decrease time interval between automatic defrost cycles in relation to calculated time. AUT (coefficient ) : microprocessor optimized automatic defrost according to type of cargo transported (variable intervals)., to,5 : increase time interval between automatic defrost cycles in relation to calculated time. H, H,... 6 H : Fixed defrost interval in hours. WARNING : when settings are adjusted if no key is activated within 5 seconds, the system reverts to box temperature display. 5 6