Monocrystalline Solar Module LGXXXS1C(W)-G4. Installation Instructions MFL

Similar documents
Monocrystalline Solar Module LGXXXN1C(W, K)-G4. Installation Instructions MFL

Installation Instructions

Installation Instructions

Installation Instructions

PV Solar MODULE. Installation manual. Please read this manual carefully before operating your set and retain it for future reference.

PV Solar MODULE. Installation manual.

PV Solar MODULE. Installation manual. Please read this manual carefully before operating your set and retain it for future reference.

PV Solar MODULE. Installation manual. Please read this manual carefully before operating your set and retain it for future reference.

PV Solar MODULE. Installation manual.

PV Solar MODULE N-TYPE MODELS

PV Solar MODULE. Installation manual.

Safety and Installation Instructions

Installation Manual. Opal Solar QSA Series

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Grape Solar Photovoltaic Modules. Safety and Installation Manual

INSTALLATION MANUAL THE / MODULE. IEC & UL version

General Installation Manual 2007 Sanyo Electric Co., Ltd. All Rights Reserved 6/15/07

General Installation Manual July 1, SANYO Energy (USA) Corp. All Rights Reserved.

INSTALLATION MANUAL.

Installation Manual AXITEC SOLAR MODULES

Grape Solar Photovoltaic Modules. User Manual

Installation Manual. Installation Manual. AXITEC, LLC 160 Greentree Drive, Suite 101 Dover, Delaware

IEC INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL FOR CRYSTALLINE SOLAR PV MODULE

INSTALLATION MANUAL MODULE TSM-PDG5/PDG5(C) TSM-PEG5/PEG5(C) TSM-PEG40 THE. UL version IEC version. TSM_UL/IEC_IM_Dec_2014_RevB - 1 -

General Installation Manual Mar 2009, Sanyo Electric Co., Ltd. All Rights Reserved 3/23/09

PM220P00 / PM240P00 Installation Guide for Users

INSTALLATION MANUAL. IEC version. TSM_IEC_IM_2012_RevB

Product Manual. Installation Instructions for CHSM-230M Series Solar Module

Grape Solar Photovoltaic Modules. User Manual

INSTALLATION AND SAFETY MANUAL for Cigs-2000A1 and Cigs-2000E1 Solar Photovoltaic Modules Release Date: Version: 1.1

Safety and Installation Instructions For Fluitecnik PV Modules

Installation Manual LIGHTWAY PV MODULES. Revision Date March 30, 2013 /Applicable for IEC certified products

Crystalline Silicon PV Module Installation Guide (JET)

INSTALLATION INSTRUCTION AND MAINTENANCE MANUAL

Solar module user manual Conergy PM 225P-250P

Photovoltaic Module User Manual

General Installation Manual for POWERCOM Photovoltaic Modules

Contents. VBHNxxxSJ40 series. VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT TM. VBHNxxxSJ40 series. VBHNxxxSJ25 series

PM300P00 Installation Guide for Users

Contents. VBHNxxxSJ40 series VBHNxxxSJ47 series. General Installation Manual. Photovoltaic Module HIT R. VBHNxxxSJ25 series VBHNxxxSJ40 series

Suniva OPTIMUS Installation and Instruction Manual Introduction. Electrical Characteristics. Safety. Mounting Overview. Product Information

Photovoltaic Modules Installation Manual for Australia

Installation manual. For professional use only

Installation guide for Suntech Power photovoltaic module Purpose of this guide

INSTALLATION MANUAL WAAREE ENERGIES LIMITED

Installation and Safety Manual

GENERAL INSTALLATION MANUAL

INSTALLATION MANUAL. For Monocrystalline Modules. According with IEC61215 edition 2 & IEC61730 standards

General Installation Manual Photovoltaic Module HIT. Contents. Model No. VBHN330SA16 and 16B VBHN325SA16 and 16B

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

VBHNxxxKA01 series. General Installation Manual Photovoltaic Module HIT. Contents. Model No. VBHN315KA01

General Safety & Installation Instructions

INSTALLATION MANUAL ECOSOLARGY SOLAR MODULE

Photovoltaic Module User Manual (CSA-UL1703)

PV Module Installation Manual

SunWize SW and OEM Series Solar Modules GENERAL INSTALLATION & USER GUIDE

INSTALLATION MANUAL Crystalline Photovoltaic Module

JinkoSolar. Photovoltaic Module. User Manual (UL1703)

JinkoSolar. Photovoltaic Module. User Manual (UL1703) 1500V

Crystalline Silicon PV Module Installation Manual

JinkoSolar. Photovoltaic Module. User Manual (UL1703) 1500V

OPTXXX-##-4-1YY IEC & UL EN Suniva, Inc. SI&IM _9 Rev 9 Page 1

Installation Manual for the photovoltaic modules brand Eurener

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

CRYSTALLINE SILICON PV MODULE INSTALLATION GUIDE THE POWER OF ASTRONERGY

Installation & Assembly. Panel SAM-CS6C-130P. Please read these instructions before installing and using this panel

Jinko Solar. Photovoltaic Module Eagle Dual. Installation Manual

JinkoSolar. Photovoltaic Module. User Manual (UL1703)

Philadelphia Solar Installation and Operation Manual

CRYSTALLINE SILICON PV MODULE INSTALLATION GUIDE THE POWER OF ASTRONERGY

JinkoSolar. Photovoltaic Module-Eagle Dual. Installation Manual

Installation And User Manual SCHOTT PERFORM POLY SCHOTT PERFORM MONO

KD240GX-LFB2, KD245GX-LFB2 KD250GX-LFB2

SN SERIES 1,000V. EN ver 03_2017

INSTALLATION MANUALFOR RISEN SOLAR MODULE

Installation. Guide. HSL Poly Series

Installation and Maintenance Manual

YINGLI SOLAR PV MODULES Installation and User Manual

PM060M00 Installation Guide for Users

INSTALLATION AND USER MANUAL FOR SHARP PHOTOVOLTAIC MODULES A) GENERAL MANUAL

RITEK SOLAR PV MODULES Installation and User Manual

JinkoSolar. Photovoltaic Module. User Manual (UL1703)

Solar Module Installation and User Manual

Assembly instructions

UL Installation guide for Suntech Power photovoltaic module

INSTALLATION MANUAL. The Solution in Black The Quadmax Solution Honey M The Aesthetic Solution The Comax Solution

AUO Photovoltaic Module Installation Manual. Version 2.0


250 Watt. Features. Positive tolerance Positive tolerance of up to 5% delivers higher outputs reliablity

Field Installation and Operation Manual for DC Smart Modules

X-SERIES SOLAR PANELS

FLEXIBLE PHOTOVOLTAIC MODULES. Instruction Manual

Version: GCLSI_ _V2. Photovoltaic Module Installation Manual for GCL System Integration Technology Co., Ltd.

Installation Manual for LONGi Solar Modules

idealpv SSP1 220/270 Solar Panel

Installation and Operations Manual

SOLAR MODULE AS-M6, AS-M7 SOLAR MODULE SERIES AS-P6/AS-P7 AS-M6/AS-M7

JA SOLAR INSTALLATION MANUAL

JinkoSolar. Photovoltaic Module. Installation Manual

JinkoSolar. Photovoltaic Module. Installation Manual

Transcription:

Monocrystalline Solar Module LGXXXSC(W)-G4 Installation Instructions MFL69000

Table of Contents. Safety 3. efore & fter Installation 4 3. Electrical Installation 5 4. Mechanical Installation 7 5. Product Specifications 9 6. Disclaimer of Liability / Disposal 0 7. Transporting and Storage 0 8. ppendix Revisions Table Date Version Description of change Remark 05.0..0 ( st edition) 05.08.6.0 dd ppendix(installation Scene)

Safety The instructions related to safety and use indicated in the this installation manual are intended for the prevention of unexpected danger, damage, or failure. DNGER Non-compliance with the instructions may cause product damage, product failure, and/or serious bodily injury or death. DNGER WRNING Do not contact electrically active parts of the panel, such as terminals, without appropriate safety gear. Contact may result in lethal spark or electric shock. Do not use or install if the module is broken or torn. Failure to comply may result in electric shock. WRNING CUTION Perform all work in dry conditions and use only dry tools. Do not handle wet panels without appropriate protection equipment. Failure to comply may result in accident or death. accident or death. Damaged modules must be treated with safety protection equipment. Failure to comply may result in serious bodily injury or death. 3 Do not approach the damaged or broken module unless you are an authorized or qualified expert. Failure to comply may result in serious bodily injury or death. 4 No electrical parts like cables are located after installation between laminate and mounting structure. 5 Do not reconnect or repair Junction ox Cable. It may occur spark or electric shock. Installation during rain, heavy wind or snowy day may result in bodily injury or death. 3 Holes in the frame or glass of the module may decrease the strength of the frame or break the glass. 4 Do not touch the glass surface or frame of the solar module after installation of the module. It may result in injury or death. 5 Heavy objects must be kept off of the solar module. Do not stand on or step on the module. Do not drop the module. Failure to comply may result in product damage, product failure or bodily injury. 6 Do not scratch the coating surface of the frame. Scratches may decrease the total solar output due to corrosion of the frame. 7 Do not artificially concentrate sunlight on the solar module surface. Failure to comply may result in product damage or failure. 8 Do not apply a shock to the junction box of the module or pull the cable. Do not remove the labels attached to the module. Failure to comply may result in damage of the product. 9 If the installing modules on curved surface, (e. g. arch type), as shown in the below picture, do not forcefully modify the module in the installation when connecting it with the structure. Only install the module in the place where the structure for the panels has been properly set up. n improper structure may cause deformation of the panels. Panels may also be damaged by unapproved installation methods such as the use of a crane. 3 4 7 5 8 6 3 4 5 9 Module Installing structure (bent type) Module Installing structure (Stralght type) CUTION Use proper equipment, connectors, wires and buttresses for the installation of the module. Failure to comply may result in product damage, product failure or bodily injury. Product Deformation Occurrence of space 3

efore & fter Installation efore Installation Please carefully read this manual before installation. Contact with electrically active parts of the panels, such as terminals, may result in burns, sparks and lethal shock whether the panel is connected or disconnected. Panels produce voltage even when not connected to an electrical circuit or load. Solar module installation and maintenance must be performed by qualified and authorized installer. ll installation instructions should be read and understood before performing any installation. Do not twist, pull, or scratch the cable attached to the solar module. Do not touch the solar module with bare hands. Failure to comply may result in a serious burn or injury. Do not drop the solar module or place weight on a solar module. Do not disassemble the solar module. fter installation or repair, check that the solar module are operating properly. In the event that the currently used solar module or parts have been replaced the newly replaced module and parts must have the same model name and parts as the previously installed solar module. Secure all necessary permits and licenses to install the solar modules Only qualified and authorized individuals are permitted to treat electrical parts, when there is a breakage, failure or damage of the product or damage of the product. Do not use or install broken modules; Failure to comply may result in fire, electric shock, and injury. Do not install the module horizontally. Failure to comply may result in excess dirt or white efflorescence (glass disease). Panels are not intended for use indoors or on moving vehicles of any kind. Reflection from external environments such as snow Reflection from external environments such as snow, water or other surfaces may increase the power generated by the panel. Industry standard rated specifications are made at conditions of 000W/m irradiance and 5 C (77 F) solar cell temperature. Colder temperatures may substantially increase voltage and power. Keep the solar module and system away from children at all times. Keep the module packed in the carton until the time of installation. Keep flammable gasses away from the installation site. Do not work alone. Please work as part of a team of two or more people. Safety harness use is strongly recommended for installation. Partial shadowing may substantially reduce panel and system output. Care must be taken to avoid low tilt angles which may cause dirt to buildup on the glass against the frame edge. Dirt build-up on the surface of the panel may cause active solar cells to be shaded and electrical performance to be impaired. lways keep the back surface of the panel free from any foreign objects or structural elements which could come into contact with the panel. fter Installation Plug in the connector tightly and ensure that the wiring properly works. Conduct periodic inspection of the panels for damage to front glass, back sheet, frame, junction box, or external electrical connections. Check electrical connections for loose connections and corrosion. Removal of dirt from the front glass can increase output. Water, ethanol or a conventional glass cleanser with a micro-fiber cloth can be used for regular washing or rinsing of the front glass to remove dust, dirt or other deposits. ggressive and abrasive cleansers or chemicals such as alkali chemicals including ammonia based solution should not be used on cleaning the module. lways wear rubber gloves for electrical insulation while maintaining, washing or cleaning panels. Deposits of foreign material on the frame surface can be cleaned by using a wet sponge or cloth and dried in air or by using a clean chamois. Perform the wiring work by connecting the connector and wires to the stand away from the roof or ground. 4

Electrical Installation Danger void all electrical hazards when installing, wiring, operating and maintaining all panels. Do not connect panels that have different electrical properties or physical configurations in the same system. Match the polarities of cables and terminals when making the connections; failure to do so may result in damage to the panel. The rating of the over-current device shall not exceed the maximum series fuse rating marked on the nameplate. The panel contains factory installed bypass diodes located inside the junction box. When installing the system, it is recommended to install a lightning rod to protect the system. The junction box should not be opened. Opening the junction box will void the warranty. Panels with a suspected electrical problem should be returned to LG Electronics for inspection and possible repair or replacement as per the warranty conditions provided by LG Electronics. Series Connection The solar modules may be wired in series to produce the desired voltage output. The current of each module connected in series should be the same. The maximum number of series connected modules can be determined by basis on max system voltage, the 5% safety factor not explained in specifications, and the module Voc which can be checked in Product Specifications in this document. Do not exceed 80% of maximum system voltage. Maximum Module configuration (recommend) : refer to the Product Specification in this manual. Series connection for more voltage Electrical Connections Shock hazard may occur near the solar modules electrical connections. Modules may be connected in series and/or parallel to achieve the desired electrical output as long as it is within the guidelines on the product specification sheet. Please use only the same type of modules in a combined source circuit. Do not disconnect the module under when it is operating. Shock hazard may occur near the solar modules connection means. Diodes ll LG modules are equipped with factory installed bypass diodes. The factory-installed diodes provide proper circuit protection for the systems within the specified system voltage. IF (V) VF (max) VRRM Tj (max) RTH 5 0.6V 50V 00 C.0 C/W 3 4 D D D3 - + Diode specification and configuration 5

Parallel Connection The solar modules may be combined in parallel to produce the desired current output. When modules are combined in parallel, the total current is equal to the sum of currents from each module. The voltage of each module connected in parallel should be the same. When connecting plural strings of modules in parallel every series string or solar module must be fused prior to combining with other strings. bide with all applicable federal, state, and local codes for additional fusing requirements and limitations on the maximum number of solar modules in parallel. Maximum parallel strings without proper measures, e. g. fuse 5 : string Parallel configuration is not limited if proper measures are taken to block the reverse current flow, e.g. fuses for the protection of the module and cables from over-current for prevention of unbalanced string voltage. multiplying factor is required for increased output of the PV modules. Under normal conditions, a PV module is likely to experience conditions that produce more current and/or voltage than reported at standard test conditions. The requirements of the National Electrical Code (NEC) in rticle 690 shall be followed to address these increased outputs. In installations not under the requirements of the NEC, the values of Isc and Voc marked on this PV module should be multiplied by a marked on this PV module should be multiplied by a factor of 5% when determining component voltage ratings, conductor ampacities, fuse sizes, and size of controls to the PV output. Depending on national directives, additional safety factors might be applicable for overcurrent protection. - - Earth Grounding ll work must be conducted in conformance with all Federal, State, and local codes and standards. Grounding works should be performed by an authorized installer for the safety and maintenance of the system in accordance with all national, state and local electrical codes and regulations and standards. Specific information on the solar module dimensions and location of grounding holes is provided in Product Specifications. One M4 stainless steel bolt, one nut, one spring washer two flat washers one cup washer one star washer and WG Cu wires are recommended per mounting hole. Where common grounding hardware (nut, bolts, washers) is used to attach a listed grounding device, the attachment must be made in conformance with the grounding device manufacturer s instructions. There is an earth hole on the edge of the module frame Using this hole an earth conductor and the solar module frame may be recommended to be connected and earthed as the below drawing. ll screws and nuts shall be tightened to a torque of 4~5 Nm. module with exposed conductive parts is considered to be in compliance with UL 703 only when is electrically grounded in accordance with the instructions presented below and the requirements of the National Electrical Code. The installation instructions shall include:. Details for wiring shall comply the NEC rticle 690.. Details for the grounding method of the frame of arrays shall comply with the NEC rticle 50. 3. CNL model instruction manuals shall also include a statement that installation shall be in accordance with CS C., Safety Standard for Electrical Installations, Canadian Electrical Code, Part. Module frame 6 Parallel connection for more current General Wiring LG Electronics recommends that all wiring be double insulated with a minimum rating of 90 C (94 F). ll wiring should use a flexible copper (Cu) conductor. The minimum size should be determined by the applicable codes. LG Electronics recommends a size no smaller than WG. olt Flat washer Star washer Cup washer Grounding wire Flat washer Spring washer Nut

Mechanical Installation Module Mounting The LG Electronics (LGE) Limited Warranty for solar modules is contingent upon modules being mounted in accordance with the requirements described in this section. ny module without a frame (laminate) shall not be considered to comply with the requirements of UL 703 unless the module with hardware that has been tested and evaluated with the module under this standard or by a field inspection certifying that the installed module complies with the requirements of UL 703. Site Consideration LGE solar modules should be mounted in a location that meets the following requirements. Operating Temperature Maximum Operating Temperature: +90 C (94 F) Minimum Operating Temperature: -40 C (-40 F) Design Strength GE solar modules are certified to basic loads 75lb/ft. (Mounting by using frame bolts holes) : 70mm(6.7 in) : 70mm (0.6 in) Excluded Operating Environments The solar modules from LG Electronics can not be operated in a location where they could come in direct contact with salt water or ammonia. Clearance between the solar module frames and structures such as roofs or ground is required to prevent wiring damage and to allow air to circulate behind the solar module. The recommended standoff height is a minimum of 00mm. When installed on a roof, the solar module must be mounted over a fire-resistant roof covering rated for the application. The fire resistance of the solar module is class C after NSI/UL790. slope less than 5in/ft is required to maintain a fire class rating. The solar module is only ETL listed for use when its factory frame is fully intact. Removal or alteration must be done by an authorized and qualified individual Creating additional mounting holes may damage the solar module and reduce the strength of the frame. We recommend a 6mm gap between module frames to avoid tension from thermal expansion. The fire rating of this module is valid only when mounted in the manner specified in the mechanical mounting instructions. The module is considered to be in compliance with UL703 only when the module in mounted in the manner specified by the mounting instructions below. The solar module may be mounted by using the following methods: (*Torque:8~Nm ) LG modules (Fire performance : Type ) shall be mounted with racking and mounting products certified and listed for system fire class rating in accordance with UL703 edition 04 and UL703 edition 04. It is recommended to check with local authorities for fire safety guidelines and requirements for any building or structure on to which the panels will be installed. When installing modules in heavy snow areas, it is recommended to be taken an appropriate countermeasure to prevent possible damages to the lower side frame by slipping snow. ( snow guard should be installed in accordance with the manufacturer s instructions.) Mounting Methods General Information Select the appropriate orientation to maximize sunlight exposure. Module should not be mounted or stored in a way that the front/top glass faces downward in order to prevent water from entering the junction box, which could cause a safety hazard. Roof Solar module Supporting part 7

Mounting by using frame bolts holes Secure the solar module to the structure by using the factory mounting holes. Four M8 stainless steel bolts, four nuts, four spring washers, and eight flat washers are recommended per solar module. The module may be fastened to a support by using both the outer and inner bolt holes of the frame. Each module should be securely fastened at a minimum 4 points on two opposite sides. Specific information on the solar module dimensions and location of mounting holes is provided in Product Specifications. Mounting by using clamps The module may be fastened to a support by using clamps on both the long edge and the short edge of the modules. Specific information on location of clipping is provided in ppendix_mechanical Installation. (Refer to page) More than 40mm Module frame olt Flat washer More than 0mm Flat washer Spring washer Nut Support More than 0mm Tighten the bolt securely by using the combination shown above. Place the spring washer between the Flat washer and Nut. 8

Product Specifications - Electrical and Mechanical Properties (Rated electrical characteristics are within 0 percent) Standard Test Condition(STC) : Irradiation,000W/m, Cell temp. 5 C,.5M Certificates Electrical Properties Mechanical Properties Module Series LGXXXSX-G4 Model Name IE EC65 Ed., IEC 6730, S afety Class II, CE, ISO900 max at STC P W ower Tolerance P % LG50SC(W)-G4 Yes 50 3% 37.9 8.9 30.7 8.6 <4.5 000 oc at STC V V Is sc at STC mpp at STC V V Im mpp at STC *E Efficiency Reduction % Max. System Voltage V onnector C Le ength mm Width mm eight H mm Weight kg ** MC4 640 000 40 7.0 LG55SC(W)-G4 Yes 55 3% 38.0 8.98 30.9 8.7 <4.5 000 MC4 640 000 40 7.0 LG60SC(W)-G4 Yes 60 3% 38. 9.05 3. 8.38 <4.5 000 MC4 640 000 40 7.0 LG65SC(W)-G4 Yes 65 3% 38.3 9. 3.3 8.49 <4.5 000 MC4 640 000 40 7.0 LG70SC(W)-G4 Yes 70 3% 38.5 9.7 3.5 8.58 <4.5 000 MC4 640 000 40 7.0 LG75SC(W)-G4 Yes 75 3% 38.7 9.6 3.7 8.68 <4.5 000 MC4 640 000 40 7.0 LG80SC(W)-G4 Yes 80 3% 38.8 9.33 3.9 8.78 <4.5 000 MC4 640 000 40 7.0 LG85SC(W)-G4G4 Yes 85 3% 38.9 938 9.38 3. 888 8.88 <4.5 45 000 MC4 640 000 40 7.0 LG90SC(W)-G4 Yes 90 3% 39.0 9.43 3.3 8.98 <4.5 000 MC4 640 000 40 7.0 LG95SC(W)-G4 Yes 95 3% 39. 9.48 3.5 9.08 <4.5 000 MC4 640 000 40 7.0 LG300SC(W)-G4 Yes 300 3% 39. 9.53 3.7 9.8 <4.5 000 MC4 640 000 40 7.0 Note : * Relative efficiency reduction by respect to irradiance ** MC4 formal name : PV-KST4 / 6II-UR, PV-KT4 / 6II-UR *** safety locking clip (MC PV-SSH4) may be required per article 690 of NEC 008. - Dimensions of Modules Unit: mm / in. LGXXXSC(W)-G4 Cross-sectional drawings Long side frame Short side frame Note : *Holder is for the convenient connection of junction box cable,but that does not warranty if it is broken after installed. 9

Disclaimer of Liability / Disposal Disclaimer of Liability y beginning the installation process the installer represents the he/she has read and completely understands this Installation Manual. He/She further represents if he/she had any questions regarding this installation manual he/she would have contacted LG with any questions or concerns. y installing an LG Solar module, I discharge, and covenant not to sue LG, its affiliated companies, successors, or assigns, its administrators, directors, agents, officers, volunteer and employees, other participants in any activity connected to installation, operation, or service of LG Solar Modules and if applicable from all liabilities claim Solar Modules, and if applicable, from all liabilities, claims, demands, losses, or damages on my account caused or alleged to be caused in whole or in part by the negligence of the LG its affiliated companies, successors, or assigns, its administrators, directors, agents, officers, volunteer and employees. Disposal Please contact us, if you have any queries related to the disposal or recycling of solar modules from LG Electronics. Transporting and Storage Do not loosen the banding, when the module is transported by truck, ship and etc. In case of loose banding, the module will be shaken, which may cause damage. Do not stack on more than one pallet. Maximum height is two pallets. Severe stacking can give stress to the module and may cause product damage. 0

ppendix_mechanical Installation Fig. Mounting Type Fig. Clamping Type 70mm (6.7 in) 70mm (0.6 in) Front : 6000Pa (5psf) Rear : 5400Pa (3psf) Fig.3 Clamping Type : 50mm (5.9 in) : 400mm (5.7 in) Front : 6000Pa (5psf) Rear : 5400Pa (3psf) Fig.4 Clamping Type : 50mm (5.9 in) : 400mm (5.7 in) Front : 6000Pa (5psf) Rear : 5400Pa (3psf) Fig.5 Clamping Type : 0mm (4.7 in) : 50mm (5.9 in) Front : 800Pa (37.5psf) Rear : 800Pa (37.5psf) Front : 850Pa (60psf) Rear : 850Pa (60psf) Fig.6 Clamping Type : 50mm (5.9 in) : 400mm (5.7 in) Front : 6000Pa (5psf) Rear : 5400Pa (3psf) * 4 point installation is allowed in the following cases:. Slope roof: If module is installed parallel to the rooftop.. Flat roof: If installed with an additional stand such as wind shield or deflector. Front : 800Pa (37.5psf) : 0mm (4.7 in) *4point() Rear : 800Pa (37.5psf) : 0mm : 80 ±00mm (3.3±3.9 in) 6point(+) Front : 6000Pa (5psf) Rear : 5400Pa (3psf) Note) ll mechanical installation method(fig to Fig 6) in this appendix were not tested by Intertek.(UL 703, ULC 703) It is evaluated by LG internal test.

LG Electronics U.S. Inc. 000 Sylvan ve, Englewood Cliffs, NJ 0763 Contact : lg.solar@lge.com http://www.lgsolarusa.com This document is subject to change without notice. LG, LG logo and Life's Good are trademarks of LG Electronics, Inc. worldwide. Trademarks and intellectual properties of LG Electronics, Inc. are protected by international copyright laws. Document : II-G4(P)-UL-V-EN-050