w.s e c.c o m.t w AUTOMATIC TRANSFER SWITCHES Instructions (MCCB TYPE) BREAKER & SWITCHGEAR SYSTEM

Similar documents
BTB TYPE AUTOMATIC TRANSFER SWITCH (ATS)

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Air-insulated switchgear UniGear type ZS1

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

Circuit Breaker Prepared By :

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Power systems Protection course

Components for EEx e Panels

section-page Table 1. Transfer switching device ratings. Conditional short circuit current

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Phoenix Inverter

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

EMPAC Metal enclosed capacitor bank for wind applications

DEEP SEA ELECTRONICS PLC

DKG-114 MANUAL AND REMOTE START UNIT

Metal Clad Switchgears

Florham Park, NJ USA Call (ASCO) for sales or service

Low Surge Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.

SECTION MOTOR CONTROL

Operator Manual. Transfer Switch. RSS100 and RSS Cummins Inc. All rights reserved. English

Operator s Manual Series ADTS Automatic Delayed Transition Transfer Switches, amps

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Florham Park, NJ USA Call (ASCO) for sales or service

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

Transfer switch OTEC and OTECSE open transition

Memshield - ACB Ratings & Specifications

Description. Positive safety relays

SafeGear TM Motor Control Center Arc resistant metal-clad construction

Panelboards & Motor Starters

Bulletin 109 IEC Non-Reversing Starters. Product Overview/Product Selection. Table of Contents

www. ElectricalPartManuals. com Operator s Manual

Vacuum Circuit Breaker VS1

22AF 40AF AF 150AF 225AF 400AF 800AF

Quality Products, Prompt Service, Trustful Relationships.

Jaeshininformation Co., of Korea Distributor

S H A D E S ELECTRICAL DB MANUFATURING

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Metal Clad Air Insulated Switchgear

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

MAHALAKSHMI ENGINEERING COLLEGE TIRUCHIRAPALLI

MNS Light F. Low-voltage switchgear with fixed units. ABB LV Systems

Manual motor starters Overview and benefits

MAGNETIC CONTACTOR & MOTOR STARTER

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

USER'S GUIDE. WiseHP11 SINGLE PHASE HIGH PRECISION AVR SERVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

DMX 3 -I 2500 switch disconnectors

MAGNETIC CONTACTOR & MOTOR STARTER

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Power System Solutions (PSS)

DEEP SEA ELECTRONICS PLC

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

DEEP SEA ELECTRONICS PLC

DPX moulded case circuit breakers

Isolation Transformer for Medical Applications

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

DEEP SEA ELECTRONICS PLC

POWER REGULATOR LD -40PSU

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

MESG 12 / 17.5 / 24 / 36 KV

SG-B1 SERIES / SG-A1 SERIES

50 Hanover Road, Florham Park, New Jersey USA For sales or service call (ASCO)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

Rated Impulse withstand voltage U imp Main circuit Between terminals, AC3500V for 1 minute 12kV terminal group to earth Control circuits

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Miniature Circuit Breaker

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

B BASIC HEAT TREATMENT CONSOLE

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

Intelligent Choice for Prestigious Buildings

Application Engineering

Operator s Manual Series ATS Automatic Transfer Switches 600 through 1200 amps

(Example) In case of DC24 to 48V, it is operating time for DC24V.

GCU-10. Automatic Engine Control Unit Operators Manual

Key features. DESIGNS: - Conservator type - Hermetically sealed

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

AF series contactors (9 2650)

MCSG 12kV / A

Softstarters Softstarters

MAGNETIC MOTOR STARTERS

Using new Magnetically Actuated Vacuum Interrupter technology for safe and reliable medium voltage circuit breaker switching in mines

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Multi-Pak Group Control

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Single & Three-Phase Soft Starters

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Mitsubishi Breaker Line-up

HEAVY DUTY POWER RELAYS FEATURES

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

Step 1: Collection of required data

Application Engineering

Transcription:

w.s e c.c o m.t w 2010 AUTOMATIC TRANSFER SWITCHES Instructions (MCCB TYPE) BREAKER & SWITCHGEAR SYSTEM

Index ATS Instructions A. General description B. MCCB TYPE Specification C. The main structure analysis diagram D. The main structure description E. Control panel - Electronic F. Control circuit diagram G. Control Panel configuration diagram H. Overall dimensions (mm) I. Working Chart J. Automatic Transfer Switch Component description K. Frequently asked questions and easy maintenance of Description P2 P2 P3 P3 P4 P4 P5 P6 P7 P7 P9 1

ATS Instructions A. General description The company s product is under the control by the strict-quality production, in full compliance with IEC standard, the control panel through the EMC certification (anti-surge, anti-noise), quality guaranteed products with high performance, high trust, and provide you with the most satisfactory service. 1 Apparatus there is access control to be installed in the electrical room, to avoid the nonelectrical maintenance staff or children close, resulting in erroneous action or a sense of power accident. 2 Placement: Install the ATS unit in any protected environment that provides adequate airflow around unit and is free from excessive dust, corrosive fumes inflammable material and conductive contaminants. Do not operate your ATS in an environment where the ambient temperature or humidity is high. 3 Transmission before the Note: 1. First of all, ATS switch to the OFF position 2. Check power line wiring is correct 3. Remove all unnecessary ATS wiring beside Normal power, back-up power, and load 4. Inspection commonly used power supply, Emergency power, load power whether there are short-circuited or grounded 5. Inspection commonly used power supply, standby power, load power of the terminals have locking 6. Control panel prohibited to use Pak 10000 Ohmmeter high voltage insulation apparatus measurements, for electric components safety. 4 Transmission in use Note: 1. During repair or operation is strictly prohibited contact with any terminal. 2. Do not rotation manual operation (except in special circumstances). 3. In addition to a specific need, please do not arbitrarily change any switch. 5 Manual Operation When the main switch for some reason, after escape, purports to switch reversion to use, or because of some accident can not be automatically converted when the operation of the following ways: Please motor connector before the operation quickly detached and manually switch to the anti-clockwise direction to your desired location, switches have ON, OFF position indicative of the power supply. B. MCCB TYPE Specification 2 Type Pole Rated current In (A) BS100CN 2P, 3P, 4P AC Rated Breaking Capacity Sym r.m.s(ka) IEC 60947-2 Icu BS100SN 2P, 3P, 4P 10, 15, 20, 30, 40, 50, 60, 75, 100. 25 15 220V 380V 10 7.5 BS100HN 2P, 3P, 4P 50 30 BS225CN 2P, 3P, 4P 30 22 125, 150, 175, 200, 225. BS225SN 2P, 3P, 4P 50 30 BS400CN 2P, 3P, 4P 35 25 BS400SN 2P, 3P, 4P 250, 300, 350, 400. 50 35 BS400HN 2P, 3P, 4P 85 50 BS600CN 3P, 4P 35 25 BS600SN 3P, 4P 500, 600. 50 25 BS600HN 3P, 4P 85 43 BS800CN 3P, 4P 50 25 BS800SN 3P, 4P 700, 800. 85 50 BS800HN 3P, 4P 100 70 BS1000HS 3P 1000. 130 100 BS1200HS 3P 1200. 130 100 BS1600HS 3P 1400, 1600. 130 100 Note 1: Rated Breaking Capacity (ka) IEC 60947-2 Note 2: Special breaking capacity please contact sales representative.

C. The main structure analysis diagram (1) MCCB (2) Status display ATS Instructions (3) The manual operation handle (4) BTS Terminal Blocks (5) Gear Motor (6) Transmission gear switch structure (7) Mechanical Interlock (8) Load Side Bus D. The main structure description (1). Shihlin Brand Molded Case Circuit Breaker (Shihlin Electric circuit breakers quality guaranteed). (2). The Input Display: Display change the red ON / Green OFF conditions, when ATS switch escape from the status quo. (3). Manual operating handle: a. Mode of operation, depending on the direction of rotation against the clock to make switch to change the ON and OFF. b. Optional handles with locks, to prevent equipment by non-management staff of arbitrary action, while the damage. (4). BTS Terminal Blocks (5). Gear Motor: The composition of induction motor and reduction gear, according to torque required switch configuration. (6). Transmission gear switch structure. (7). Mechanical Interlock devices: The use of seesaw principle of chain device, in any side of the MCCB inputs on the other side of the bakelite MCCB will bulge to withstand the primary contact, to avoid both sides of the Switch inputs at the same time. (8). Load-side bus (400A and above): Copper forging, jumper two of the secondary side switches, copper-handling devices on the base below the copper connections with copper pillars connected with each other, after locking, and to Silver welding, strengthening the conductive area, resin covered conductive adhesive as a whole at any thickness up to 1.5mm, insulation withstand voltage of over 1000V or more. 3

ATS Instructions E. Control panel - Electronic 1. Features a. Following EMC standard (IEC 60947-6), with anti-surge and anti-noise capability. b. Reading Status Easily: LED lights show status of power supply and load. c. Self-testing function: (1).Generator testing switch(auto-on-off) (2).Normal power failure simulation test(test-auto) d. Flexibility: Option funtion for Over and under voltage protecter and Input phase fault detector 2. Delay timer instructions a. TDEN: Time delay of transfer from Emergency to Normal when the normal power returned to nomal. b. TDNE: Time delay of transfer from Normal to Emergency when the normal power supply is abnormal. c. TDES: Time delay on engine starting when the normal power supply is abnormal.(fixed 4 seconds). d. TDEC: Time delay for engine cool-off after the power supply from the emergency power to the utility power. Supply voltage: AC 220V 50/60Hz Disk hole size: 194.5mm Width (W) x 164mm high (H) F. Control circuit diagram Normal power N3 N2 N1 LOAD Emergency power L3 L2 L1 E1 E2 E3 T S R Mechanical Interlock U W T R U W 1 S2 11 21 9 9 10 10 TNR NLS ELS TER NR NLS ELS TDEN 6 7 TDNE AUTO TEST F 6 7 S1 OFF NR TDES TDEN TDEC TNR Power M Power TER TDNE ER TDES E ER Access to the remote control signal generator 38 8 TDEC G TNR 8 TER NR Notes: 1.S1 Generator Remote Control Auto / Test function 2.S2 common side power simulation test 3. Dashed line for the additional equipment 4. Controlling voltage is 220V, if no please install the transformer voltage Code Description: TNR, TER, ER: Power Relay M: motor TDEN: from emergency to normal power supply switching time required TDNE: from normal to emergency power supply switching time required TDEC: generator shutdown delay time TDES: generator start time delay 4

S.W R SHANG WET S.W R SHANG WET G. Control panel configuration diagram Control panel (back) Description G F Normal power failure simulation test Generator contact (USE 3.5mm 2 LINE) Analog power test Test Auto 3P-ATS access line 3Ø3W 220V Control panel (back) Terminal Blocks 9A 8A 7A 3A 2A 1A 10 7 6 8 9 W (NE) U T (NN) R ATS Instructions 21 11 6 7 8 9 10 R S T U V W NN NE 9A 8A 7A 3A 2A 1A 10 7 6 8 9 W (NE) U T (NN) R Fuse BTS Terminal Blocks BTS 3P-ATS access line 3Ø4W 220V/380V 4P-ATS access line 3Ø4W 220V/380V Control panel(back) Terminal Blocks Control panel (back) Terminal Blocks 9A 8A 7A 3A 2A 1A 10 7 6 8 9 W U T R 9A 8A 7A 3A 2A 1A 10 7 6 8 9 W U T (NE) (NN) (NE) (NN) R 6 7 8 9 10 6 7 8 9 10 R S T U V W NN NE Neutral R S T U V W NN NE BTS Terminal Blocks BTS Terminal Blocks BTS ATS for the 3P Connection : System voltage : 3Ø3W 220V : Normal power supply connect to R, T, Emergency power connect to U, W. 3Ø4W 220/380V : Normal power supply connect to R, Emergency power connect to U, neutral (N) connect to T, W. 3Ø3W 380 ~ 480V above : Normal power supply through the transformer into a 220V connect to R, T, Emergency power through the transformer into a 220V connect to U, NE. ATS for the 4P connection mode : System voltage : 3Ø4W 220/380V : Normal power supply connect to R, NN, Emergency power connect to U, NE. 3Ø4W 120/208V: Normal power supply connect to R, T, Emergency power connect to U, W. Notes: The control power supply for 220V input, such as input supply must be installed without 220V transformer (PT). Transformer (PT) selected : a. 225AT The following selection of 100VA. b. 250 ~ 400AT selection 150VA. c. 500AT selection above 300VA. 5

ATS Instructions H. Overall dimensions (mm) 165 105 3P BS100 & BS225 type 394 374 107 180 107 30 340 21 130 197 55 165 105 4P BS100 & BS225 type 450 430 100 210 140 390 21 130 197 55 3P BS100 & BS225 high capacity(ka) type 4P BS100 & BS225 high capacity(ka) type 30 165 105 107 394 374 180 340 107 21 130 220 55 165 105 450 430 103 210 138 390 21 130 220 55 3P BS400 type(including high capacity(ka) 4P BS400 type(including high capacity(ka) 490 470 121.5 247 121.5 282 554 534 121 268 166 282 32.5 30 30 257 192 434 200 65 257 192 504 200 65 3P BS600 & BS800 type 4P BS600 & BS800 type 618 598 156 306 156 294 747 727 156 365 226 294 275 48 180 200 40 200 65 275 180 40 40 200 80 559 689 3P BS1000 above high capacity(ka) type 68 406 271 622 602 158 306 158 205 105 200 105 200 438 358 100 Description: 1. This table using the units of millimeters (mm) mark. 2. This form is only marked (for industrial use - Standard type) size. 3. This table is for standard specification, if requir the special specification, please contact representative. 6 559

I. Working Chart of the ATS NORMAL SOURCE (N1,N2,N3) EMERGENCY SOURCE(E1,E2,E3) GENERATOR TDES <---> 1 TDNE <---> TDEN <---> TDEC <---> ATS Instructions LOAD(L1,L2,L3) 2 2 REMOTE GENERATOR NOTE : 1.Generator is Start by Manual operation or Signal from F-G Terminal (TDES) 2.Time for Mechanical Tranfer position 3.TDES = is fixed time 4 sec J. Automatic Transfer Switch Component description Note. * Number table is non-standard goods, For purchase information, please contact the company, and in order that stated in * 1. TIME DELAY ON ENGINE STARING (TDES) When the normal(common) power supply is irregular or disappear, the engine will start after 4 seconds (standard) A. Fixed 4 second (standard) B. Adjustable 1 ~ 3 minutes (custom) 2. TIME DELAY NORMAL TO EMERGENCY (TDNE) When the normal(common) power loss, while the engine starting voltage is established, the relay (TDEN), begin to set the value of time, so that normal(common) power switch to emergency(standby) power supply. A. Adjustable 1 ~ 30 seconds (standard) B. Adjustable 1 ~ 60 seconds (custom) C. Adjustable 1 ~ 30 minutes (custom) 3. TIME DELAY EMERGENCY TO NORMAL (TDEN) When the normal(common) power supply is back to normal, the relay (TDEN), that is set to embark on the value of time, so that emergency(standby) power switch to the normal(common) power. A. Adjustable 1 ~ 30 seconds (standard) B. Adjustable 1 ~ 60 seconds (custom) C. Adjustable 1 ~ 3 minutes (custom) 4. TIME DELAY FOR ENGINE COOL OFF (TDEC) When the normal(common) to restore power supply, and switch is completed, the relay (TDEC), namely, the value set to embark on the start time so that the engine generator under no-load shutdown. A. Adjustable 1 ~ 60 seconds (custom) B. Adjustable 1 ~ 3 minutes (standard) C. Adjustable 1 ~ 30 minutes (custom) 5. TEST SWITCH This switch can be used assuming power outage, so that generator operation and load testing functionality of ATS. 7

ATS Instructions 6. Two / three-stage selector switch A. TEST: Available on the assumption that power outage, so that generators start, and switch to standby (emergency) power supply. B. OFF: to make the engine shut down. C. AUTO: in this location. 7. PILOT LIGHTS Emergency(standby) power load indicator (red) Normal(common) power load indicator (green), made 8. ENGINE START CONTACIS Is used to control the engine starter generator 9. RELAY AUXILIARY CONTACIS Normal(common) power auxiliary relay (NR) 2a2b contact Emergency(standby) power auxiliary relay (ER) 2a2b contact * 10. High Breaking Capacity Molded Case Circuit Breaker If you need this high capacity (ka) non-melting line circuit breaker can refer to the company s MCCB catalog choice. * 11. REV. PREVENING RELAY Could confirm that the phase sequence and the lack of three-phase phase, to prevent the reverse-phase motor running. The protector system has nothing to do with voltage detection and the load. * 12. UNDER VOLTAGE RELAY A. Mining-phase protection design standards, with a view to operating voltage voltage display from 85 ~ 264V, detection voltage range of 1V ~ 499V, can be set to escape and restore the value. B. Normal(common) side and Emergency side 3 the installation of a three-phase protection. * 13. OVER VOLTAGE RELAY Over-voltage sensing relays, the detection voltage range of 1V ~ 499V, can be set to escape and restore the value. 14. CONTROL FUSE Control circuit with fuse, just installed in the main control line. * 15. Remote-line non-single-contact If the generator itself, the remote control circuit is not a single contact, that is, remote control line in three or more, please specified. 8

K Frequently asked questions and easy maintenance of Description 1. Why normal power outages, generators will not start? Solutions: a. Control panel to selectively switch (AUTO-OFF-TEST) change to the TEST position. (This feature is to launch a remote control signal generator) b. Generator does not start factors: i. Generator Remote Cord not linked: Please connect. ii. Generator itself isn t on automatic position: Please change to the automatic position. iii. Signal diameter is too small (or too far away), change more than 3.5mm 2. c. After following A and B action, change switch back to AUTO position. ATS Instructions DC24V - R Generator start selector switch G + ATS 2. Why Normal power outages, generators started, but there is no switching power supply? Solutions: a. To determine the control panel, whether the standby power LED lights be switched on or micro-light. b. No lighting condition Description: i. Not yet reached the ATS generator voltage output of a measurement (the amount of UW whether there is 220V) ii. N-phase generator Missed. iii. Control panel fuse burned: Please take control back of the spare fuses for replacement. c. There are lighting conditions: Measuring (8), (10) whether there is 220V. A. No, to confirm the motor capacitor line then good. B. Yes, please contact the technical staff. (Possibly motor immersion) Standby power LED light 3. Why is the normal power is restored, but did not switch power supply? Solutions: a. To determine the control panel, LED lights were used on incoming calls whether the switch-or micro-light. b. No lighting condition Description: i. Nornal power voltage output not yet reached the ATS time measurements (the amount of (R), (T) whether there is 220V) ii. Missed normal power N-phase iii. Control panel fuse burned down: (if (R), (T) with 220V) Please take control back of the spare fuses for replacement iv. Control panel, change switch back to auto position. v. (11), (21) contact is short-circuit chip is loose. c. There are lighting conditions: Please contact the technical staff. normal power LED light 9

ATS Instructions 4. Why is the normal power is restored, generators can not be shut down after the time? Solutions: a. To confirm whether the COOL OFF lights switched on b. Lighting conditions Note: (generator operation) i. Generating its own built-in delay shutdown feature. ii. Check TDEC timer in the other sets ATS. iii. Generator is switched to automatic. c. No lighting: Please contact the technical staff. 5. Normal power supply and power LED lights are available but no output? Status: AUX circuit breaker may malfunction. Solution: Please contact the technical staff. 6. Generator power and LED lights are available but no output? Status: AUX circuit breaker may malfunction. Solution: Please contact the technical staff ENGINE COOL OFF of the LED lights 7. Why ATS has been rotating motor will not stop? Status: a. Breaker failure. b. Mechanical chain of failures. Solution: a. Please remove control panel (8) line (motor power line) b. Please contact the technical staff. 10

M E M O 11

M E M O 12

www.seec.com.tw VCB Vacuum Circuit Breaker Based in Taiwan Breaker & Switchgear System Towards the Development of Globalization MCB / ELCB Miniature Circuit Breaker BHA Miniature Circuit Breaker ACB Air Circuit Breaker SW1100-P Pre-Payment Electricity Meter BHP Surge Protective Device MCCB / ELCB Molded Case Circuit Breaker / Earth-Leakage Circuit Breaker MS Magnetic Contactor / Switch SW3005 Multi-function Electricity Meter BBIT Sleeve SLPR 3-phase Sequence Protection Relay ATS Automatic Transfer Switches SPM8 Digital Multi-Meter BW Wall Switch & Socket

BREAKER & SWITCHGEAR SYSTEM Vacuum Circuit Breaker, Air Circuit Breaker, Molded Case Circuit Breaker, Earth-Leakage Circuit Breaker, Miniature Circuit Breaker, Automatic Transfer Switches, Surge Protective Device, 3-phase Sequence Protection Relay, Magnetic Contactor / Switch, Wall Switch & Socket, Sleeve, Digital Multi-Meter, Multi-function Electricity Meter, Pre-Payment Electricity Meter. w.s e c.c o m.t w /w.s e c u s a.c o m Head Office 16F, No.88, Sec.6, Chung Shan N. Rd., Taipei, 111 Taiwan T. +886-2-2834-2662 F. +886-2-2836-6187 Export Sales Dept. 3F, No.9, Sec.1, Chang-An E. Rd., Taipei, 104 Taiwan T. +886-2-2541-9822 F. +886-2-2581-2665 e-mail. export@seec.com.tw Breaker and No.234, ChungLun,HsinFun, HsinChu,Taiwan Switchgear Factory T. +886-3-599-5111 F. +886-3-599-5259 Overseas Office 80 South Lake Avenue, Suite 780, Pasadena, CA 91101 Shihlin Electric U.S.A. T. +1-626-535-0132 F. +1-626-535-0134 e-mail. sales@seecusa.com Area Distributor 2010, 1,000 Copyright reserved