Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Similar documents
Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Benefits, typical uses

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

NXPLUS C Single busbar. Maintenance-free for lifetime

Metal Clad Switchgears

UniGear. Technical Guide

MESG 12 / 17.5 / 24 / 36 KV


with Vacuum Circuit Breaker HAF

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

ZX-Family Gas-insulated medium voltage switchgear

Metal Clad Air Insulated Switchgear

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

the safe, reliable, and efficient choice for MV switchgear

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Modular medium-voltage switchgear. NorMax

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH 36 for Secondary

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

8DJ. Maintenance-free for lifetime

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

NXAirS Withdrawable Medium-Voltage Switchgear up to 24kV Air-Insulated

CPG.0 Single busbar gas-insulated cubicles

Air-insulated switchgear UniGear type ZS1

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

Medium-Voltage Switchgear OPERATING INSTRUCTIONS

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

ZX2.2 Gas-insulated medium voltage switchgear

ZX2 Gas-insulated medium voltage switchgear

ga-gae630 2 ry Distribution Switchgear

Gas Insulated Metal-clad Switchgear, HMGS!

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

Vacuum Circuit Breaker

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

VB1-D Generator Circuit-Breaker Switchgear

COMPACT SUBSTATION GUIDE

Valid for you. medium voltage switchgear

cgm.3 2 ry Distribution Switchgear

PIX High. Medium-voltage switchgear. Air-insulated switchgear kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual

Power IT Air Insulated Cubicle Uniswitch

Medium Voltage Distribution PI 100. up to 24 kv Air-insulated circuit-breaker switchgear for primary distribution. System configuration

EnergieBlock TEB. Industrial unit substation air-insulated 12 kv / 24 kv AN-/AF-Operation roof-ventilators arc fault tested with HRC fuses

UniSec Operation and maintenance manual

Unified requirements for systems with voltages above 1 kv up to 15 kv

Gas-Insulated Switchgear. Type 8VN1 blue GIS up to 145 kv, 40 ka, 3150 A

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

Fixed-Mounted Circuit-Breaker Switchgear Type NXPLUS C up to 24 kv, SF 6 -Insulated. Medium-Voltage Switchgear Catalog HA 35.

Features. 2 Siemens HA Page. 8DJ10 switchgear is a factoryassembled,

HIGS Highly Integrated Generator Circuit-Breaker Switchgear

W 12 ELEKTROTECHNISCHE WERKE FRITZ DRIESCHER & SÖHNE GMBH. DRIESCHER - Air-Insulated Medium-Voltage Switchgears

Unitole UP kv Primary substations Motor control centres

The Key Link for all your Distributions Needs. A Comprehensive Range for All Your Needs

cpg.0 GIS-type medium-voltage switchgear with full insulation in SF 6 gas, up to 40.5 kv in accordance with IEC Standards

Air-insulated switchgear with

PIX-H Metal-clad switchgear up to 17.5kV

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

Unitole UP kv Primary substations Motor control centres

with Vacuum Circuit Breaker HAF

Gas Insulated Switchgear

Air-Insulated Medium-Voltage Switchgear NXAIR, up to 24 kv

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Contents. We build a better future! MCC HCB

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

For your safety! Foreword

Transcription:

BasisBlock MC 1

Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage [kv] 28 50 Rated lightning impulse withstand voltage [kv] 75 125 Short circuit strength Rated short-time withstand current [ka] 25 20 Rated surge withstand strength [ka] 65 52 Rated short-circuit duration [s] 1 1 Arc fault qualification IAC A F L acc. to IEC 62271-200, duration 1s [ka] 25 20 Rated current, busbars [A] up to 1250 up to 1250 (higher currents available on request) Rated current, feeders [A] 630 630 1250 1250 Frequency [Hz] 50/60 50/60 Dimensions [mm] Width 600/650/800 800 Depth 1035 1185 Height 2200 2200 Side wall 40 40 Height with electric-arc-deflector [mm] 2340 2340 Required ceiling hight [mm] 2840 2840 Ambient air temperature [ C] +5 up to +40 Degree of protection IP3X Max. operating height above sea level [m] 1000 Colour (higher RAL colours are optional) RAL7032 page 2 of 8

Standards and classifications The switchgear MC1 is used predominantly at the primary distributor-level. It complies to the classifications of IEC 62271-200, VDE 0671-200 and BS EN 62271-200 Category of operation LSC 2A Partition-class PI Accessibility to areas Busbar area Switchgear room Connecting area Interlock-controlled Internal arc classification The following internal arc qualification has been conducted: IAC A F L IAC = Internal arc classification A = 300 mm distance of the indicators during control (Installation in closed, electrical place of operation) F = Indicators during the testing from the front L = Indicators during the testing from the side I sc = Testing current up to 25 ka t = Arc duration 1s page 3 of 8

Technical Description Construction: The switching panel is of a bolted construction using high-quality galvanised sheet steel with a thickness of 2 mm. An extraordinarily torsionally rigid, self-supporting sheet steel structure is achieved by the appropriate folding of the edges. The front uses pressure resistant doors which can be opened by means of an lifting mechanism. It opens to an angle of almost 180. The door stop can mounted occur alternatively on the right or on the left side. Adjacent panels are compartmentalised with respect to one another by the two sidewalls and an air cushion, which is required by design when joining the cells together. Cast resin bushings are incorporated between the panels in the busbar-area. All fitted components are accessible from the front. The pressure is released upwards by top-mounted, safeguarding pressure relief flap. These open in the event of an overpressure resulting from an internal arcing fault. page 4 of 8

Technical Description Busbars and feeders: These consist of commercial flat copper Lengthwise compartmentalised, panel by panel Circuit breaker: The circuit breaker can be moved on a withdrawable unit in the circuit breaker compartment between the isolated / test position and the operating position with the door closed. Withdrawable unit: The withdrawable circuit breaker unit consists of a removable frame on which is mounted the circuit breaker and which contains all interlocking devices and runs on rollers fitted at the sides. The mechanical principle of the withdrawable units accords with the latest design knowledge for such tasks. The withdrawable unit can be moved from the operating to the isolated position with a horizontal swivel movement of only about 80. In the isolated/test position, after releasing a mechanical latch, it can be removed from the cell and onto a service truck. Cable connection, transformers, earthing switch: This area is generously sized for both the current and voltage transformers, it can also accommodate the cable clamps rails and the earthing switch. The earthing switch is operated by means of a detachable lever located in the right-hand sidewall. The detachable lever can only be inserted or withdrawn in the ON or OFF position of the earthing switch. Low voltage compartment: The low voltage compartment is incorporated into the switch panel as a selfcontained, sheet steel compartmentalised unit with its own door. It is separated from the medium voltage area so as to be touch-safe and pressure-tight. Sufficient space is provided for relays, terminals, miniature circuit breakers, etc. Protection relays, push buttons, measuring instruments, status indicators and field units for switchgear control systems can be mounted in the door. The secondary cables between the switch panel and the withdrawable unit are connected by means of a standard plug and socket connector. page 5 of 8

Technical Description Operator Safety: Anyone who has experienced an internal arc test knows what affect the release of a high electrical power supply output during the ignition phase has. Air is converted to a gas with a temperature of about 4000 C. It is enriched with combustion and vaporisation residue from copper, steel and cast resin. Arc deflector The gas mixture is released through the top at an angle by an arc deflector. Interlocks and switching fault protection: In order to avoid dangerous situations and switching faults, reliable mechanical interlocking devices are provided between the circuit breaker and the switching panel for the protection of personnel and parts of the equipment. The interlocks fulfil the following functions: The circuit breaker can be opened or closed in the isolated / test position. The withdrawable unit is always earthed. The withdrawable unit can only be moved in and out between the isolated / test position and the operating position when the circuit breaker is open. Closing is inhibited during this time. The withdrawable unit is locked in the operating position. Only then can the circuit breaker be opened or closed. Operating personnel safety: For working within the cell, a plate made of insulating material can be inserted in the open isolating path of the withdrawable unit when the door is closed. Side-mounted guide rails completely seal the cell from above, i.e. in the direction of the busbars Finish: All sheet steel parts, which are not galvanised, are powder coated. Standard colour RAL 7032, slate grey. Other RAL colours are optional. page 6 of 8

Technical Description The following equipment can be provided: Vacuum-circuit breakers 12 kv up to 1250 A 24 kv up to 1250 A Load-break switches 12 kv and 24 kv with and without HRC fuses Rated current according to the used fuse. HRC fuses with striker-release page 7 of 8