Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

Similar documents
Operating instructions sonnenbatterie eco 8.0 for operators

Installation instructions. sonnenbatterie.de. for authorised electricians. KD-429 Part no.

Installation instructions for authorised electricians sonnenbatterie hybrid 9.53

Installation manual wall-mounted distributor

Installation manual portable distributors

Wilo-Control SC-Fire Jockey

User Manual Rittal PMC UPS 6kVA

BMW i. Freude am Fahren. BMW i Wallbox Plus. Owner's manual

c-go 24V/6A 24V/8A 24V/12A

MP V 8A Electronic Smart Charger. Instruction and Information Manual

Battery Charger JCB- SCH20LI.2

C3 Operating Instructions

BMW i. Freude am Fahren. BMW i Wallbox Plus. Instructions for use

Cordless Rechargeable Saw Instructions for Use

User Manual TABLE MAGNIFIER TL-70. User-friendly Manual ID: #05007

Operating manual UPS - System

OPERATION & MAINTENANCE INSTRUCTIONS

Wind power inverter WINDY BOY 5000-US/6000-US WINDY BOY 7000-US/8000-US. 1 Notes on this addendum. 1.1 Validity. 1.2 Target group

Getting started with

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER


OPERATION & MAINTENANCE INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

KeContact P20. User manual

Pulsar EXtreme 2200C / 3200C

Assembly and Maintenance Manual Type ASNU

FREQUENCY INVERTER INSTALLATION & USER GUIDE

Operating manual. original operating manual. HDA eco Box 12/24V DC Automatic Dispenser. Translation of the. Item No.:

Wind Power Inverter WINDY BOY 5000A/6000A

AXA DALI P20. DALI Broadcast Controller. Installation Manual

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Oil-free piston compressors KK and piston vacuum pumps KV

Version: 1.0 Mat.-Nr.: DBUS-WB50-80US

Assembly instructions

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

1.Safe testing IMPORTANT:

Manual. Curtis Model 1625 Battery Charger. Curtis Instruments, Inc. 200 Kisco Avenue Mt. Kisco, NY

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Compressor Refrigerator Instruction Manual

BATTERY CHARGER-STARTER

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Power Inverter 400 MW Owner s Manual

Battery System User Manual for Panasonic LJ-SK56A BATTERY SYSTEM USER MANUAL FOR PANASONIC LJ-SK56A

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

Catalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Battery Charger JCB-FCH20LI2

LCD video-goggle with 5,8 GHz diversity receiver HIVR 101

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

CPS Energy Balancer. Version: 1.0

BYD Battery-Box HV User Manual Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Assembly and Maintenance Manual Type AS

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

1200W INVERTER GENERATOR

Domestic Water Supply Pressure Pumps

System Monitoring SCHOOLMETERBOX AU

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

2.0Ah BATTERY INSTRUCTION MANUAL

KEWTECH. KT56 digital multi function tester. Instruction manual

Assembly and Maintenance Manual Type RSBW

T35 W35. Thermoelectric cooler Instruction Manual 6. Thermoelektrische Kühlbox Bedienungsanleitung 16. Glacière thermoélectrique Notice d emploi 27

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Register your instrument! HeatSealer S100. Operating manual

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

1100W PORTABLE GENERATOR

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

SMART ENERGY SAVER Manual

230VAC Power Inverter 400W Owner s Manual

AXIAL FANS Axis / Tubo OPERATION MANUAL

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Battery Charger JCB-FCH12Li

CORDLESS WORK LIGHT CORDLESS WORK LIGHT. Operation and Safety Notes IAN

LEAD ACID BATTERY CHARGER

Accessories for power generation plants in Italy SMA GRID GATE

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Operating Instructions. bluesmart Active

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

MGE TM Galaxy TM 7000

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

OPERATION MANUAL BATTERY CHARGER DFC-10P DFC-50P DFC-450P DFC-650P

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

Pulsar EXtreme CLA 1500C

Originalbedienungsanleitung/Ersatzteilliste 5. Original operating manual/spare parts list 11

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

MGE TM Galaxy TM 7000 GFC

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

Filterpack FR-BFP2-(H)0.4K to (H)15K

PV Inverter SUNNY BOY 3300/3800

Manual. Taucher O.Wulf 6. R/C Pilot boat. No. 2072

Instructions for use and installation Cooker Hood

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

User s Manual Power Supply IM E. 5th Edition

Transcription:

Operating instructions for operators sonnenprotect 1300 KD-337 Part no. 22010 Version X00 info@sonnenbatterie.de www.sonnenbatterie.de

EN IMPORTANT Read this documentation carefully before operation. Retain this document for reference purposes. Publisher sonnen GmbH Am Riedbach 1 87499 Wildpoldsried Service number +49 8304 92933 444 E-Mail info@sonnenbatterie.de Document 2 / 20 Document number KD-337 Part number 22010 Version X00 Valid for AU Publication date 04/0/2017

1 Information about this document4 Table of contents 1 Information about this document...4 1.1 Target group of this document...4 1.2 Designations in this document... 4 1.3 Explanation of symbols... 4 2 Safety... 2.1 Intended use... 2.2 Qualified electricians... 2.3 Operating the sonnenprotect... 6 2.4 Product modifications or changes to the product environment...6 2. Voltage inside the sonnenprotect...6 3 Product description...7 3.1 Technical data... 7 3.2 System components... 8 3.2.1 System components... 8 3.2.2 Control and display elements...9 3.3 Type plate... 10 3.4 Symbols on the outside of the sonnenprotect...10 4 Function...11 4.1 Basic principle... 11 4.2 Grid operation no grid outage...11 4.3 Emergency operation grid outage...11 4.4 Protection provided by the insulation monitor...12 Commissioning...13.1 Commissioning the storage system...13.1.1 Switching on the miniature circuit breaker...13.1.2 Switching on the storage system...13.2 Setting the backup buffer... 1.2.1 Establishing connection to the storage system...1.2.2 Setting the backup buffer... 16 6 Maintenance...17 6.1 Checking function... 17 6.2 Cleaning... 17 7 Troubleshooting...18 8 Uninstallation and disposal...19 8.1.1 Uninstallation... 19 8.1.2 Disposal... 19 3 / 20

1 Information about this document 1 Information about this document This document describes the installation of the sonnenprotect 1300 in connection with the sonnenbatterie eco 8.2 storage system. Read this document in its entirety before beginning the installation work. Keep this document in the vicinity of the sonnenbatterie. 1.1 Target group of this document This document is intended for the operator of the storage system and the sonnenprotect. 1.2 Designations in this document The following designations are used in this document: Complete designation Designation in this document sonnenbatterie eco 8.2 storage system sonnenprotect 1300 sonnenprotect 1.3 Explanation of symbols DANGER DANGER Extremely dangerous situation leading to certain death or serious injury if the WARNING WARNING Dangerous situation leading to potential death or serious injury if the safety CAUTION CAUTION Dangerous situation leading to potential injury if the safety information is not Notice Notice Indicates actions that may cause material damage. safety information is not observed. information is not observed. observed. Important information not associated with any risks to people or property. Symbol Meaning Work step 1. 2. 3. Work steps in a defined order List Table 1: Additional symbols 4 / 20

Safety 2 Safety 2.1 Intended use The sonnenprotect 1300 is an emergency power unit designed to supplement the sonnenbatterie eco 8.2. The sonnenprotect provides power to the connected consumer even if a grid outage occurs. It can only be operated together with the right storage system from sonnen GmbH. Any other use is considered improper use. Improper use poses a risk of death or injury to the user or third parties as well as damage to the product and other items of value. The following points must therefore be observed in order to comply with the intended use of the product: Only operate the sonnenprotect together with the right storage system. The sonnenprotect must be installed by an authorised electrician. The sonnenprotect must only be connected to the storage system as described here. The output of the sonnenprotect must not be connected to the building mains. Only connect an electrical consumer that does not exceed the nominal power (in continuous operation) and maximum power (when switched on) of the sonnenprotect. The sonnenprotect must only be used at a suitable installation location. The transport and storage conditions must be observed. Failure to comply with the conditions of the warranty and the information specified in this document invalidates any warranty claims. 2.2 Qualified electricians Improper installation can result in personal injury and/or damage to components. For this reason, the sonnenprotect must only be installed and commissioned by authorised electricians. Authorised electricians must meet the following criteria: The electrician must be a person with technical knowledge or sufficient experience to enable him/her to avoid dangers which electricity may create. The company for which the electrician works must be certified by sonnen GmbH. The electrician must have successfully complete sonnen GmbH certification / 20 2

2 Safety training for the storage system. 2.3 Operating the sonnenprotect Incorrect operation can lead to injury to yourself or others and cause damage to property. This device can be used by children from the age of eight (8) years old and individuals with impaired physical, sensory or mental capabilities or individuals with limited knowledge and/or experience of working with the device, as long as they are supervised or have been trained to safely use the device and understand the resulting risks of doing so. Children must not play with the device. Cleaning and user maintenance must not be carried out by children without supervision. The sonnenprotect must only be operated as described in the product documentation. 2.4 Product modifications or changes to the product environment The sonnenprotect must only be used in its original state without any user modifications and only when in perfect working order. Safety devices must never be overridden, blocked or tampered with. The interfaces of the sonnenprotect and the storage system must be wired in accordance with the product documentation. The number of plug outputs on the sonnenprotect must not be changed. All repairs on the sonnenprotect must be performed by authorised service technicians only. 2. Voltage inside the sonnenprotect The sonnenprotect contains live electrical parts, which poses a risk of electrical min shock. The storage system inverter also contains capacitors which carry voltage even after the storage system is switched off. As the sonnenprotect is connected to the inverter of the storage system, this means that the voltage from the inverter also flows into the sonnenprotect. Therefore: Do not open the sonnenprotect. Do not remove any plastic covers. 6 / 20

Product description 3 Product description 3.1 Technical data sonnenprotect 1300 System data Maximum power (2 sec.) 2,200 W Nominal power 1,300 W Output voltage (AC) 240 V +/- 10 % Nominal frequency 0 Hz Network configuration in emergency IT operation Operating concept Single-phase power supply via plug outlet. The switch to emergency operation takes place automatically through the storage system. Switchover time approx. 3 seconds Dimension / Weight Dimensions (H/W/D) in mm 23/10/124 Weight in kg approx. 2 kg Safety Protection class II (protective insulation) Degree of protection IP 21 Protective functions Overcurrent protection, insulation monitor (as per IEC 617-8) Ambient conditions Ambient temperature range C 30 C Storage temperature range 0 C 40 C Transport temperature rang -1 C 40 C Max. rel. humidity 90 %, non-condensing Permissible installation altitude 2,000 m above sea level Additional ambient conditions The ambient conditions prescribed for the storage system apply. Table 2: Technical data 7 / 20 3

3 Product description 3.2 System components 3.2.1 System components 1 2 ON AL Test Reset 20 40 60 100 3 Figure 1: System components sonnenprotect No. Designation 1 sonnenprotect 2 Plug outlet 3 F1.P (Z6) miniature circuit breaker 4 K2.P insulation monitor Table 3: Description of the system components 8 / 20 80 4

Product description 3.2.2 Control and display elements 2 3 4 ON AL 1 Test K2.P RAL 6 Reset 20 40 kω 60 F1.P 100 80 Figure 2: Control and display elements No. Designation Function 1 Miniature circuit Reversing the switch activates/deactivates the plug outlet breaker of the sonnenprotect. ON LED Lights up when power supply is on (indicates emergency 2 operation). 3 AL LED Lights up when an insulation fault occurs, i.e. when the insulation resistance drops below the set alarm value (RE < RAL) (in emergency operation). 4 Test key Pressing the test key simulates an insulation fault, thereby testing the function of the device. The AL LED lights up and the connection to the plug outlet of the sonnenprotect is interrupted for as long as the test key is held. Reset key No function. 6 RAL setting Turning sets the RAL alarm value (recommended setting: 100 Ω/V). Table 4: Description of the control and display elements 9 / 20 3

3 Product description 3.3 Type plate The type plate for the sonnenprotect is located on the outer surface of the system. The type plate can be used to uniquely identify the sonnenprotect. The information on the type plate is required for the safe use of the system and forservice matters. The following information is specified on the type plate: Item designation Item number Technical data 3.4 Symbols on the outside of the sonnenprotect Symbol Meaning Warning: electrical voltage min Warning: electrical voltage Wait five minutes after switching off (capacitor de-energising time). CE mark The product meets the requirements of the applicable EU Directives. WEEE mark The product must not be disposed of in household waste, dispose of it through environmentally friendly collection centres. Observe the documentation The documentation contains safety information. 10 / 20

Function 4 Function 4.1 Basic principle The plug outlet of the sonnenprotect supplies electrical power both in grid and emergency operation. The storage system with sonnenprotect automatically toggles between grid operation to emergency operation. The switchover time between grid and emergency operation is stated in the technical data. 4.2 Grid operation no grid outage If the public electricity grid is not experiencing an outage, the consumer connected to the sonnenprotect will be continuously supplied with electrical power. This electrical power is drawn directly from the grid and the batteries of the storage system are not discharged by the usage of the sonnenprotect. The storage system controls the flows of energy in the building and reserves the set backup buffer. The insulation monitor is deactivated in grid ON AL operation: ON LED is off. Test Reset RAL 20 40 kω 60 100 80 Figure 3: Insulation monitor in grid operation 4.3 Emergency operation grid outage The storage system automatically detects grid outages and disconnects from the public electricity grid. The plug outlet of the sonnenprotect is not supplied with electrical power for the approx. three seconds it takes to switch over to emergency operation. After this point, the consumer connected to the plug outlet is supplied with electrical power until the backup buffer of the storage system batteries is depleted. Once the backup buffer is used up and the battery s minimum state of charge has been reached, the plug outlet of the sonnenprotect is no longer supplied with electrical power. 11 / 20 4

4 Function 1 Total capacity 2 Available electrical power in grid 2 1 operation 3 Backup buffer Minimum state of charge 3 4 Figure 4: Distribution of overall capacity The insulation monitor is activated in emergency operation: ON LED lights up. ON AL Test Reset The storage system switches back to grid operation with a delay after a grid outage. This can take a few minutes. During this time the plug outlet is supplied with power in emergency operation. RAL 20 40 kω 60 100 80 Figure : Insulation monitor in emergency operation 4.4 Protection provided by the insulation monitor The insulation monitor checks the insulation status of the IT network, which the sonnenprotect forms in emergency operation. If an insulation fault occurs, the insulation monitor terminates the connection to the plug outlet of the sonnenprotect. The AL LED lights up. When the insulation fault no longer exists, the connection to the plug ON AL Test Reset outlet is automatically re-established. The AL LED goes out. RAL 20 40 kω 60 100 80 Figure 6: Insulation monitor in the event of an insulation fault 12 / 20

Commissioning Commissioning.1 Commissioning the storage system It is essential to follow the instructions in the given order when switching on a storage system with sonnenprotect because the storage system cannot otherwise function properly..1.1 Switching on the miniature circuit breaker Switch on the F1.P miniature circuit breaker for the sonnenprotect. ON AL Test Reset 20 40 DANGER WARNING CAUTION Notice 100 80 60 Figure 7: Switching on the F1.P.1.2 Switching on the storage system If the storage system can t be switched on: Do not attempt switching on the storage system more then three times. Contact the service! Further attempts can damage the battery modules. Fuse switch F1 establishes the connection between the battery and the inverter. To be able to switch on fuse switch F1, switch S1 must also be pressed. 13 / 20

Commissioning 1 Press switch S1 and hold it down while the following steps are carried out. 2 Switch on fuse switch F1. 3 Keep switch S1 held down for at least another seconds. S1 4 Release switch S1. F1 off off off Figure 8: F1 and S1 at the top side of the storage system The storage system then starts up and performs a self-test. Once the self-test is successful, the storage system is ready to operate. 14 / 20

Commissioning.2 Setting the backup buffer.2.1 Establishing connection to the storage system The storage system is connected to the router of the home network. Your laptop also accesses the home network. Proceed as follows to access the web interface of the storage system: Start a browser (e. g. Firefox, Chrome, Safari, ) at your laptop. Enter the address finde-meine.sonnenbatterie.de in the address line of your browser. https://finde-meine.sonnenbatterie.de The following window appears: Figure 9: website finde-meine.sonnenbatterie.de Click the button Konfigurieren. The login page appears. Select your preferred language and log in as User with the following password: Sonnen2016 The Dashboard page appears. Figure 10: Dashboard page 1 / 20

Commissioning.2.2 Setting the backup buffer Click on the button Settings. Select Backup Buffer. Change the percentage of the Backup Buffer to a desired value. Figure 11: Settings page 16 / 20

Maintenance 6 Maintenance For fault-free, safe, reliable and long-lasting operation of the sonnenprotect, it is essential to carry out regular function checks and cleaning. DANGER 6.1 Checking function Maintenance interval Action to be taken Every 6 months WARNING CAUTION Notice Check the function of the insulation monitor with help of the Test key (see 3.2.2 - p. 9). Table : Checking function 6.2 Cleaning Risk of material damage due to use of unsuitable cleaning agent an excessive water Unsuitable cleaning agents can scratch the surfaces. Furthermore, if cleaning is not carried out properly, water can get inside the sonnenprotect and cause damage. For this reason: Do not use scouring cloths, sponges or cleaning agent. Use only moist cloths, not wet cloths. Do not use water jets. Carefully clean the outside of the sonnenprotect with a clean, moist cloth. For tougher dirt, use a small amount of household dishwashing detergent on a moist cloth. 17 / 20 6

7 Troubleshooting 7 Troubleshooting Disturbance Possible reason Correction The plug outlet of the There is an insulation fault. Contact the electrician which installed sonnenprotect is not supplying any the sonnenprotect. The insulation fault power. needs to be corrected. The AL LED of the insulation monitor is on. The plug outlet of the There is a grid outage. Wait until the public grid begins sonnenprotect is not supplying any The battery is completely discharged. supplying power again. power. The F1.P miniature circuit breaker of the Switch on the F1.P miniature circuit The ON LED and AL LED of the sonnenprotect is switched off. breaker. The storage system is switched off. Switch on the storage system. The F1.P miniature circuit breaker is An electrical consumer with a power Only connect consumers with a power switching off. consumption rating that is too high is consumption that does not exceed the connected to the plug outlet of the nominal power of the sonnenprotect. insulation monitor are off. sonnenprotect. Only connect consumers with a power consumption that does not exceed the maximum power of the sonnenprotect when switched on. The consumer connected to the Some consumers do not function in an IT Contact the electrician which installed plug outlet of the sonnenprotect network configuration. For example, a the sonnenprotect. It needs to be checked functions in grid operation but not flame monitor, which is often integrated in whether the electrical consumer functions in emergency operation. gas condensing systems, requires a in an IT network configuration. connection to the earth potential, which does not exist in an IT network configuration. 18 / 20

Uninstallation and disposal 8 Uninstallation and disposal 8.1.1 DANGER WARNING CAUTION Uninstallation Improper uninstallation of the sonnenprotect Danger to life due to electrocution! The sonnenprotect must only be uninstalled by authorised electricians. 8.1.2 Disposal The sonnenprotect must not be disposed of as domestic waste! Notice Dispose of the sonnenprotect in an environmentally friendly way trough suitable collection systems. Figure 12: WEEE symbol 19 / 20 8

8 Uninstallation and disposal 20 / 20