RMF Rolling Media Filter Operation & Service Manual

Similar documents
OPERATION MANUAL MYCO SELF INDEXING UNIT. Clearstream Filters Inc. 57 Arnold Sayeau Dr. Delhi, ON, N4B 2W9 Tel Fax

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

MFS/MFD HY-TRAX Installation Guide

MODEL 4470GX. Ideal for grinding, honing, light metal removal.

Instruction & Parts Manual for. Power Rotary Machine

WARCO CHEMAG SERIES GH FILTERS

MOREHOUSE INSTRUMENT COMPANY, INC. 60,000 LBS CAPACITY AIRCRAFT PART NUMBER SCALE S FORCE CALIBRATION PRESS PART NO.

This instruction is valid for all ACF/UCF pump models shown on page 2

This instruction is valid for all ACF/UCF pump models shown on page 2

ZDM Positive Displacement Flow Meter User Instructions

Installation, Operation and Maintenance Manual

Medium and high pressure pumps

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Type 644 and 645 Differential Pressure Pump Governors

INSTALLATION, OPERATION, LUBRICATION, & MAINTENANCE MANUAL FOR THE 300-G JUMBO PUGMILL

ENVIRO UNIT CES SERIES

High Accuracy Mechanical Fuel meter FM-100

SOLAROY 12 VDC Metering Pump

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

SAI GM Series Piston Hydraulic Motor Crankshaft Design Radial Piston Motors

Fisher 644 and 645 Differential Pressure Pump Governors

Installation and Operating Instructions. Gravity Band Filter Typ PF

VSCP Vertical Suspended Column Pump Operation & Maintenance Manual

Gauges, Sight Glasses and Vacuum Breakers

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

4 - Way Control 4 - Way Control 4 - Way Control with lock

HOOD EXHAUST OR SUPPLY PROPELLER FAN

APP S 674 pumps APP S / APP S APP S

8.1.4 The 175 ml, 250 ml, or 500 ml unit may be used for static filtration testing up to and including 175 C (350 F).

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

GP-2000 : Trouble Shooting. Cause of problems

OPERATION AND PARTS MANUAL

BMF TROUBLESHOOTING GUIDE

APP pumps APP / APP / APP (W) / APP / APP / APP Lenntech. Data sheet

PACKING, HANDLING, TRANSPORTING AND STORING MOTORS

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Contamination Handbook. For use with the Schroeder EasyTest Patch Test Kit (EPK) and TWG Fluid Analysis

AXIAD II Fans. General Installation, Operation and Maintenance Instructions For Aerovent Products

02. Purpose : Heating / Drying / Calcination etc. 04. Feeder System : 0.5 H.P. Motorized Screw Feeder with VFD.

LIQUEFIED GAS PUMP INSTALLATION

GL Ludemann Y-Strainers

Crispin Valves Operating Guide. Crispin

TABLE 1: COMPARISON OF GREASE AND OIL LUBRICATION. housing structure and sealing method. speed. cooling effect. removal of foreign matter

SECTION HYDRAULIC SYSTEM

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES

HYDRAULIC SYSTEM, ISL-07

MODEL 900 IMPELLER-TYPE FLOW METER

FOX TrimAway INSTALLATION AND OPERATING INSTRUCTIONS FAMILIARIZE YOURSELF WITH THE SYSTEM COMPONENTS

Model 800 Disassembly Instructions and Troubleshooting

DeZURIK G-SERIES MANUAL ACTUATOR USED ON BOS BUTTERFLY VALVES

ZTM AND ZTMB ZENNER TURBINE METERS INSTALLATION, MAINTENANCE AND SERVICING

2/4/6.3, PAH 10/12.5, PAH 50/63/70/80/100 pumps

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

Hydrostatic Power Train

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

COMPANY. Pneumatic Flow Meters Installation, Operating & Maintenance Manual AW-Lake Company. All rights reserved. Doc ID:PNEUMAN082516

GREEN & GREEN 1000 ELECTRONIC LAVATORY FAUCET. InstallatIon and maintenance guide

DeZURIK R1 POWERRAC ACTUATOR ON 1/2-3" PEC ECCENTRIC VALVES

SERIES ARH INSTALLATION AND OPERATION INSTRUCTIONS FOR THE HORIZONTAL AUTOROLL & MANUROLL

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

26 Series Stainless Steel 2-way Ball Valves

DeZURIK MANUAL G-SERIES ACTUATORS USED ON PEC ECCENTRIC VALVES

Operating Instructions. High Energy Vibratory Finishing Bowl. Model FSV-25/50. Vibra Finish Company

Design and Application Details MICRO-RATIO Valves

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

Suggested Installation & Operating Instructions for Sidewinder Pumps

DeZURIK R1 AND R2 POWERRAC ACTUATORS

MODEL 1100 TURBINE FLOW METER

Suggested Installation & Operating Instructions for Sidewinder Pumps

3 Spin Klin Battery Operation and Maintenance Manual

SERIES 2000 GAS SAFETY SHUT OFF VALVE

Specification: Industrial Mixing Center

Fisher 585C Series Piston Actuators

Installation, Operation and Maintenance Instructions

To ensure proper installation, digital pictures with contact information to before startup.

Filters. HF3P Series Places 60 b c x d DP 4 Places Flange

Domestic Pump 2 NPSH Horizontal Pumps Series HB17, HB35, DB, DB-F

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

Best Practice Variable Speed Pump Systems

PAHT pump PAHT X

Table of Contents. Choke Principle...4

Single and Parallel Installation

Operating instructions Flow monitors SI / / 2010

INSTALLATION & SERVICE INSTRUCTION MANUAL W.A. KATES FLOW CONTROLLERS FC VALVE MODELS E THRU M

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

PAHT pumps / PAHT G pumps / ATEX PAHT G pump

Variable Air Volume Dampers

MODEL 200 MULTI-JET FLOW METER

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

Model: TON AXLE JACK. March 1999 Rev.-02

Design and Application Details MICRO-RATIO Valves

Transcription:

8 L-4205 RMF Rolling Media Filter Operation & Service Manual 580 West Park Road Leetsdale, PA 15056 ph. 724.318.1100 fax 724.318.1200 An ISO 9001:2008 Certified Company www.schroederindustries.com

580 West Park Road Leetsdale, PA 15056 ph. 724.318.1100 fax 724.318.1200 L-4205 Created 7.2012

- TABLE OF CONTENTS - 1. System Installation... 4 2. Principle Of Operation... 4 3. System Operation... 5 4. Control System... 5 5. Timer Adjustment... 5 6. System Maintenance... 6 7. Control Panel Schematic... 6 8. RMF System Components... 7-9

L-4205 RMF User Manual 1. System Installation Please refer to parts list for component identification. The Rolling Media Filter is designed as a stand-alone filtration system, if it is mounted above a suitable tank or equipped with a pump to remove the filtered fluid from the base of the filter. Inspect Filter for any damage that may have been caused during shipment. In order to ensure trouble free operation and easy maintenance of your Rolling Media Filter, installation should be carried out following the tips provided below. The filter should be mounted or installed as close as possible to level position. Ensure that sufficient space is provided for maintenance installation and removal of spent filter media. Install an isolation valve upstream of the filter when the source of fluid supply cannot be shut off for maintenance. If fluid supply cannot be interrupted for service, bypass line should be installed around the filter. The outlet of the filter should not be restricted. If outlet is restricted, it can cause fluid backup in the main filter tank to the point where the fluid makes contact with the level probe. If this situation occurs, the filter will index filter media continuously. Adjust level probe to about 2 (50mm) above filter media (honeycomb conveyor). After electrical power supply is connected check rotation of Speed Reducer. Ensure that it is turning in a clockwise direction (110V is factory set). Adjustment spring (13) shown in photograph 1.0 is factory set to prevent leakage from filtration area and containment wheels. If leaks occur tighten appropriately. 2. Principle Of Operation A motor driven metal conveyor (7) is used to carry filter media (9) and to form a trough between two wheel discs (5). The liquid to be filtered is pumped or gravity fed into inlet (1). It is then distributed to the headbox (15), which slows the velocity and discharges the liquid over the width of the filter media (9). The liquid passes through the filter media, leaving the solids on the filter media. The clean liquid is collected in the tank or discharged into an open system. As the solids are collected on the filter media, the liquid level rises to a preset level. A level sensor (3) initiates an index cycle and fresh media is indexed, displacing a portion of spent media. The spent media is discharged to waste. 4 En 7.2012 Schroeder Industries

User Manual RMF L-4205 3. System Operation Place a roll of filter media on shaft provided and locate in mounting bracket with filter media unwinding from the topside of roll. Place the leading edge of the filter paper on the conveyor. While holding on conveyor, press and hold the green manual index button (12) shown in photograph 4.0 on the control panel until the filter media is sandwiched between conveyor and seal wheels. Continue to press and hold the manual index button until the filter media exits the filter unit. 4. Control System To adjust the amount of media indexed each time the maximum level is reached on the level probe, open the control panel door and adjust the timer shown below. The recommended amount of filter media to be indexed each time the level probe is activated is 4 to 6 inches (10 to 15 cm). This amount may have to be adjusted depending on the nature and the amount of solids. To adjust the level probe, loosen the screw in the clamp ring and raise or lower the level probe to desired height. The height of the level probe may have to be adjusted, depending on nature of solids. For most typical installations the level probe should be set at 2 above conveyor s lowest point. 5. Timer Adjustment There are two timers in the control panel that need to be adjusted: the media indexing timer and the delay timer. To adjust the amount of media indexed each time the maximum level is reached on the level probe, open the control panel door and adjust the media-indexing timer (11) shown in Photograph 4.0. The recommended amount of filter media to be indexed each time the level probe is activated is 4 to 6 inches (10 to 15 cm). The approximate setting is 0.5 seconds. This amount may have to be adjusted depending on the nature and the amount of solids. The filter is also equipped with a delay on timer (10) shown in photograph 4.0 to prevent false media indexing from splashing liquid or other causes. This delay on timer is adjustable from 0 to 3 seconds and must be set with a time interval that is greater than the setting on the media index timer. (Note the scale on the delay on timer is in percentage and not seconds). A typical setting would be 3 = 30% of 3 seconds or 0.9 seconds. If the Media Index timer is set at 1.0 second, the delay on timer must be set higher than 1 second. 7.2012 Schroeder Industries En 5

L-4205 RMF User Manual To adjust the level probe, loosen the screw in the clamp ring and raise or lower the level probe to desired height. The height of the level probe may have to be adjusted, depending on nature of solids. For most typical installations the level probe should be set at 2 above conveyor s lowest point. 6. System Maintenance All Bearing Units are factory lubricated, ready to use. In extremely wet applications additional grease may be added to completely fill the bearing cavity. For general purpose applications, use #2 consistency Lithium Base Grease, with rust and oxidation inhibitors. Examples: Shell Alvania #2, Mobilux #2, Texaco Multifak #2 For many applications operating at slow speeds and in a clean environment, there is no need for re-lubrication. For speed reducer, see separate manual attached. 7. Control Panel Schematic 6 En 7.2012 Schroeder Industries

User Manual RMF L-4205 8. RMF System Components Key Number Part 1 System Inlet 2 Cloth Roll Support 3 Level Sensor 4 Control Panel 5 Wheel Disks 6 Motor 7 Metal Conveyor 8 System Outlet 9 Filter Media - Cloth 10 Delay Timer 11 Media Indexing Timer 12 Manual Index Button 13 Adjustment Spring 14 Spent Media Collection Container 15 Head Box 16 Gear Reducer 1. RMF Unit (Side View) 7.2012 Schroeder Industries En 7

L-4205 RMF User Manual 2. RMF Unit (Wheel & Conveyor) 3. RMF Unit (Front View) 8 En 7.2012 Schroeder Industries

User Manual RMF L-4205 4. Control Panel (View 1) Control Panel (View 2) Control Panel (View 3) 7.2012 Schroeder Industries En 9