Industrial Static Var Compensators

Similar documents
Company profile 2 Profile of ČKD ELEKTROTECHNIKA 2

DYNACOMP. The top-class reactive power compensator

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

ELG4125: Flexible AC Transmission Systems (FACTS)

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Power Quality and Energy Management

PQC-STATCON. PPHVC-Power Quality Solutions. Instantaneous and stepless power quality compensation for dynamic reactive power and unbalanced loads

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

The Application of Power Electronics to the Alberta Grid

FINHRM FINHRM5 FINHRMA FINHRMAC

Power Quality innovative SolutionS for industrial and distribution grids.

Dynamic reactive power compensation

POWER QUALITY SOLUTIONS FOR INDUSTRIAL AND DISTRIBUTION GRIDS. W WW.R EINHAU S EN.COM

PQC - STATCON The ultra fast Power Quality Compensator

PPHVC Power Quality Solutions. ABB PQC-STATCON Benefits and advantages

EPRLAB FAQ v1.0 Page 1 / 8 Copyright EPRLAB December 2015

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

High Power Rectifiers for the DC Arc Furnace Industry The smart solution for smooth and energy efficient production

Heatsinks and accessories

S C ELECTRIC EUROPE LTD. Excellence Through Innovation. Harnessing the Wind. November 2011 Descriptive Bulletin E

Implementation of FC-TCR for Reactive Power Control

HV Compensation & Filtering Products

Targeted Application of STATCOM Technology in the Distribution Zone

Surabaya Seminar Ferdinand Sibarani, Surabaya, 30 th October Power Quality

ADF. Restoring the perfect wave

Power Protection Discrete Automation & Motion South Africa

ahead of time Voltage Stabilisers

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

HIGH POWER RECTIFIER SYSTEMS

1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General

ELECTRIC TRACTION.

More power for railway lines Maximum efficiency with proven system behavior

Synchronous condenser solutions siemens.com/energy/facts

Three Phase Capacitors KNK

LV Capacitor Bank APC

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Traction Systems GC01DTR01_C 08/2013. Ingeteam Traction

LV Capacitor Bank APC

C1000 Series Automatic Cap Bank

Overview of Flexible AC Transmission Systems

Shunt reactors Proven history for future success

Power Electronics

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

LV Capacitor CLMD03 Power Module Instruction manual

Magnetically Controlled Reactors Enhance Transmission Capability & Save Energy Especially in Compact Increased Surge-Impedance- Loading Power Lines

Optimizing Drive Systems for Energy Savings

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Dynamic PFC:Thyristor Modules TSM Series

ABB Wind Power Solution

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

MODVAR Low voltage reactive power compensation modules Installation manual

B kv Gas-insulated Substations

Medium voltage drive for single or multimotor applications, 3 27 MW

Versatile and Powerful. Liduro Wind Frequency Converter System

ABB n.v Power Quality in LV installations

Concepts And Application Of Flexible Alternating Current Transmission System (FACTS) In Electric Power Network

Power System Solutions (PSS)

Solutions for Power Quality and Productivity

Chapter 3.1: Electrical System

AIR CORE REACTORS. Phoenix Electric Corporation

Power Quality Improvement Using Statcom in Ieee 30 Bus System

Qingdao Zener Electric Co., Ltd

EMPAC Metal enclosed capacitor bank for wind applications

Metal enclosed capacitor banks: ABBACUS family

ELECTRONIC EQUIPMENT DISTRIBUTION POWER ELECTRONIC COMPONENTS

Low voltage capacitors CLMD Improving power factor and enhancing power quality of your network

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

Unit Protection System for Pumped-Storage Power Stations

American Traction Systems

HVDC. TMT&D provides the best and most economical HVDC system.

ABB FACTS Grid connection of Wind Farms

Modular Standardized Electrical and Control Solutions for Fast Track Projects

Date Issued: 10 August 2009 Status: ISSUED Review Date: 10 August 2011 Ref: NS5.3 DISTRIBUTED GENERATION TECHNICAL REQUIREMENTS TABLE OF CONTENTS

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Technical News. Power Factor Correction. What technology is best for you? Specialists in electrical and automation products, systems and solutions

Power Conversion System for ESS 100 kw to 30 MW Bi-directional Inverters

SIMINE DRAG. Innovative solutions for maximum productivity and reliability. Mining Technologies

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

AMERICAN ELECTRIC POWER 2017 FILING FERC FORM 715 ANNUAL TRANSMISSION PLANNING AND EVALUATION REPORT PART 4 TRANSMISSION PLANNING RELIABILITY CRITERIA

Impulse Voltage Test System, Q Structure, kV

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

Frequently Asked Questions. ABB low voltage drives Low Harmonic AC drives, 7.5 to 2800Hp

CTU 02. Thyristor switching module for fast PF compensation. User manual

Product brochure. Medium voltage AC drive ACS2000, kw, kv

Exercise 6. Three-Phase AC Power Control EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Introduction to three-phase ac power control

POWER QUALITY SOLUTIONS FOR INDUSTRIAL AND DISTRIBUTION GRIDS. W WW.R EINHAU S EN.COM

Paper ID: EE19 SIMULATION OF REAL AND REACTIVE POWER FLOW ASSESSMENT WITH FACTS CONNECTED TO A SINGLE TRANSMISSION LINE

ABB November 16, 2016 Slide 1

ABB central inverters PVS to 2000 kva

Product brochure. Medium voltage AC drive ACS 2000, kva, kv

AC/DC Arc Furnace and Ladle Furnace Transformers

INTRODUCTION. In today s highly complex and interconnected power systems, mostly made up of thousands of buses and hundreds of generators,

SINAMICS GM150 IGCT version

PhiCap Capacitors for Power Factor Correction

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Switchgear and Distribution Systems for Engineers and Technicians

Transcription:

Industrial Static Var Compensators

ČKD ELEKTROTECHNIKA - Company profile ČKD ELEKTROTECHNIKA, a.s., a member of ČKD GROUP, has a long term tradition in development and production of electrical equipment, especially semiconductor applications. We supply our products to the following segments: mining industry and metallurgy oil, gas, chemical industry power engineering environmental protection infrastructure processing industry Production programme ČKD ELEKTROTECHNIKA includes: static var compensators regulated electric drives control systems converter stations for city public transport and railways very high voltage sources for electrostatic precipitators complete supplies of technological units special applications of power electronics technical support, testing, commissioning and maintenance services Our competitive advantages: we are focused on the supply of products and services on the individual projects we offer technically optimal design reflecting minimization of total costs in the case of investment activity, especially with renovation or modernization of existing equipment we pay significant attention to customer service, modernizations, deliveries of spare parts and consulting 1

1. Why is reactive power compensation so important Asynchronous electromotors as well as distribution and rectifier transformers constitute the basic load in industrial grids; During operation inductive load generates reactive power which causes oscillation between the load and the source (generator); Inductive load doesn t create any useful working load; it generates a magnetic field which causes additional harmful load in power grid. Reactive power is a negative factor, affecting the whole grid, with the following consequences: additional losses in conductors due to increased current reduction of power distribution network capacity total harmonic distortion (THD) causing interference, affecting operation of electric devices and microprocessor technology which results in production process disturbance, with negative influence on main power equipment: Transformers increased transformer temperature, even without load. Change of acoustic parameters (higher noise level). Decrease of power and degradation of insulation materials of transformers. Cables increase of cable temperature, cable insulation breakdown. Electric motors temperature increase of electric motors at nominal load. Possible resonance effects. Electric motors run with non-standard time delay. Change of acoustic parameters (higher noise level). Capacitors increased temperature, breakdowns, and explosions. Fuses THD have negative impact on fuses, resulting in unexpected and misguided equipment cut-offs. Fields of application of the static Var compensators SVCs are intended for use in power-intensive production processes in the following sectors: metallurgy mining processing industry railways SVCs can be used in various electric systems generating or consuming reactive power: asynchronous electric motors transformers induction and arc furnaces electric drives of pumps, fans and compressors 2

2. The Static Var Compensator effects Reactive power compensation allows: improved power factor causes reduction of current losses as well as overall costs of electric power; reduction of the load in power distribution network units (supply lines, transformers and distribution plants), thus increasing their operational lifespan; reduction or elimination of harmonics increasing efficiency of the equipment due to reduction of failure rate caused by breakdowns of distribution network units (cable lines, power transformers) and microprocessor devices, minimum malfunction of protective devices; increasing reliability and cost-effectiveness of power distribution networks, and thus, reduction of operation costs; electrical arc furnaces (EAF) in steel-making industry shortening of tap-to-tap time, electrode savings, reducing wear of furnace lining due to more stable arcs, substantial flicker reduction; voltage stabilisation, increased voltage on the load bus. power consumption, increased production costs, shortening of equipment lifespan and decrease of operation reliability and breakdowns of power supply systems. SVC can be used for the purpose of reduction of harmonics, stabilization of voltage, minimization of flicker disturbances on own and neighbouring facilities. As a result installation of SVC systems results in significant increase of technological and economical effectiveness of operation of industrial equipment. Example of economical efficiency of SVC installation at EAF (steel works): Increased and stabilized voltage on the load bus after installation of SVC allows decreasing steel processing time up to 15% reduction of one heat time, and thus increasing productivity by 15% owing to: Energy savings; Reduction of active power losses in the transformer; Reduction in consumption of electrodes; Reduction in consumption of natural gas and oxygen; Economical benefits of the Static Var Compensator Operation of the technological electric equipment in power grid with non-rated parameters and significant distortion of the harmonicity of supply voltage results in economic losses due to increased Remark Economic effect can be much more significant after implementation of penalty charges for consumed reactive power. With SVC 100 Without SVC 90 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 Melting time before and after installation of SVC 3

3. Basic components and principle of functioning Basic SVC concepts: with dynamic automatic current control with thyristor control (static var compensator SVC) step controlled compensator, with and without harmonic filters combined type step controlled combined with static var compensator Basic principle of SVC functioning Static var compensator system provides dynamic reactive power and is directly connected to the bus of an electric appliance. Maximum SVC s reactive power is generated by capacitors of harmonic filters and is equal to maximum reactive power of the appliance. Reactive power control is conducted by thyristor valve which regulates current of TCR reactors and compensates excess reactive power of the capacitors in harmonic filters. Control and protection system of the static var compensator provides quick reactive power load, while maintaining controlled parameter, protecting SVC equipment, monitoring and signalizing failures and it also can be tailored in compliance with customer s wishes. Response time of the SVC control system to changes of controlled parameters is 5 ms for EAF and 25-100 ms for general industrial applications and transformer substations. SVC control and protection system allows unmanned operation of the equipment. Rated power and combination SVC device components are defined for particular projects depending on parameters of the power supply system as well as type and power of compensated load. An example of an installation SVC for electric arc furnace. 4

Basic components of the SVC system: Thyristor-controlled reactor (TCR) consists of a three-phase thyristor-controlled transformer and three reactors. Power generating section of the thyristor-controlled transformer is made up by one or several COMPACT modules, manufactured by ČKD: voltage (current) control using reactor smooth control of the output power, from maximum (α=90 ) up to full blocking of the element (α=180 ). Control and protection unit MODULEX: TCR control and communication with the master system Capacitor battery and filter reactors Air cooling of thyristor valves: Cooling of thyristor valves; cooling power designed in compliance with local operational conditions Example of SVC Layout Thyristor valve and control unit cabinet are located indoors TCR reactors and harmonic filters are located outdoors 5

3.1. Air-cooled thyristor valve The basic SVC component device is the thyristor valve which regulates current in TCR reactors and, thus, totals SVC power. Thyristor valve consists of three power blocks (each block for one phase). Each block has optical thyristors, RC circuits, thyristor switching-state signalization and coupling system. Operating voltage of the converter depends on the quantity of series-connected thyristors. The controller sends electric switching signals to the optoelectronic system, where these signals are con- verted into optical ones. Optical signals are transmitted to the thyristors via optical cable. In this way, optoelectronic controller provides correct switching of all necessary thyristors, connected in series. The optical thyristor also includes overvoltage protection using avalanche diodes (BOD) to switch the thyristor when the injection impulse has not been sent. Thyristors and damping resistors are cooled by fans. Three-phase thyristor converter for SVC to 10 kv The power unit (single phase) three-phase thyristor converter for SVC 22/27.5/33/35 kb (more than 400 A) The power unit (single phase) three-phase thyristor converter for SVC 22/27.5/33/35 kb (up to 400 A) Example of a three-phase thyristor converter for SVC 35 kv, 110 MVAr 6

3.2. Main advantages of air cooling The cooling system of SVC s thyristor valve manufactured by ČKD ELEKTROTECHNIKA is based on use of company s own ALTRA heat pipes. The air cooling system has a lot of advantages compared with water cooling: Reliability of operation The air cooling system is less sophisticated compared to water-cooling systems. Proper operation of cooling system based on heat pipes doesn t require extra electronics, mechanical and rotating components, and as a consequence there are fewer potential sources of failures. Heat pipes used in ČKD ELEKTROTECHNIKA s converters operate in closed loop with no forced circulation of coolant and the fan is the only mechanical component of the cooling system The air passing through the power blocks cools not only heat pipes but also other components (capacitors, resistors etc.). Cooler system (heat pipe) ALTRA Simplicity of operation and maintenance Heat pipes are completely sealed and do not require additional maintenance. air cooling eliminates the use of additional equipment such as collant cleaning, watercooling systems, pipes, couplings, etc. Heat pipe thermal cycle 1) Working fluid evaporates to vapour absorbing thermal energy. 2) Vapour migrates along cavity to lower temperature end 3) Vapour condenses back to fluid releasing thermal energy 4) Working fluid flows back to higher temperature end 4 1 2 3 7

3.3. MODULEX Control and protection unit Due to wide range of parameters, air-cooled converter units MODULEX can be utilized in low-voltage applications of low or medium power systems. Control unit consists of semi-conductor converter block which includes power circuits with potential-free modules, turn-on pulse units, overvoltage protection and high speed fuses. Depending on particular project, converter unit MODULEX can also contain EMADYN D K regulator allows the following operations (within capacity range of the filters and inductive power of TCR group): control and regulation of cos φ parameter in the grid control and regulation of reactive power in the grid Converter MODULEX microprocessor regulator EMADYN of various types as well as touch screen panel. Power supply circuits of the converter unit MOD- ULEX have been designed for maximum feeding voltage 500 В, ±10%, 50Hz. EMADYN D K regulator is intended for switching on/ off compensation and control: local non-remote control via buttons, switches and EasyView touch screen control panel, installed on the front side of the cabinet. remote control via external potential-free contacts remote control via RS485 interface (Modbus protocol) Regulator EMADYN while regulation of cos φ and reactive power, EMADYN D K regulator can also symmetrize the grid (i.e. eliminate negative-phase sequence component). EMADYN-D-K regulator can control up to three HV breakers (as an option) for connection of not controlled high harmonic filters (if these breakers are installed). 8

3.4. Outdoor reactors The reactors are connected with the capacitor banks to provide adjustable filtration circuits for reduction, blocking and/or filtration of higher harmonics. The reactors are self-supporting structure, aircooled windings. Reactor windings are made either with or without tappings, depending on the need to provide for required inductivity by change-over switches without load Standard parameters of tappings: 90 100 110 % 90 95 100 105 110 % 90 92,5 95 97,5 100 102,5 105 107,5 110 % of rated inductivity. Insulation, impregnation and coating material is F temperature class. The windings are made of parallel aluminium conductors, insulated with fiberglass on aluminium cross-shaped structure, with top and bottom brackets. Top brackets are fit for lifting and fixing of the unit during transportation, bottom brackets are intended for fitting of reactors on the foundation (supporting insulators). 3.5. Capacitor banks Made of reliable capacitors, 600 700 kvar, voltage up to 20 kv, outdoor installation, with built-in sectional fuse links and discharge resistors supplied as assemblies (capacitor blocks) with insulators and busbars, non-balanced current protection transformer and overvoltage protections (optionally) 9

4. Stages of implementation of Static Var Compensator Preparatory stage Operating measurements of power grid Operating measurements in the conditions of your corporate network of low-, high- and very high-voltage, incorporating voltage and current harmonics, voltage symmetry and fluctuations, power flows, power factor of the basic harmonic, active and reactive el. work, transient phenomena. These measurements can be oriented on establishment of interference sources in the network, on diagnostics of the existing compensation device or on obtaining the underlying documents for the optimum design of the compensation system. Results of measurements are processed by a special software in the form of well-arranged graphs and the measurement report focused on practical consequences for the customer following from the measurements; the simple and clearly formulated conclusion and summary is also not missing. Technical solution Technical solution of the static Var compensator system, incl. Set of components and their layout, solutions on modernisations and reconstruction of existing equipment Delivery of the equipment (standard option) Basic design Thyristor valve TCR reactors Capacitor banks and filter reactors Control and protection unit Cables for auxiliary and switching impulses Technical documentation Spare parts Assembly supervision Commissioning Personnel training Warranty service Additional options Project Supply of auxiliary equipment Supply of power cables Disassemblies and assemblies 10

5. After Sales service One of key-factors of our success are quality services provided to our customers, including technical service, spare parts as well as wide variety of technical service programmes during the entire service life of the equipment. After equipment commissioning ČKD provides fullscope start-up training for customer s specialists Our service teams use the most advanced technologies and operate in the territories of Europe, Asia and in other regions, including operation via remote access. ČKD ELEKTROTECHNIKA offers supply of remote access devices in the scope of delivery to allow remote control of the equipment either by the customer or technical service specialists (via internet or GSM). Our clients can download files containing information from regulators and send them for analysis or software modification to ČKD ELEKTROTECHNIKA s headquarters in Prague. After the analysis and modifications, changed software or recommendations for repair will be sent by technical service department to the customer. ČKD ELEKTROTECHNIKA guarantees high level of technical service provided exclusively by highly qualified specialists. ČKD ELEKTROTECHNIKA guarantees sending a service engineer to carry out necessary technical service within 24 hours on business days or on the next business day, if the requirement by the customer was obtained on weekends/holidays. Maintenance services in the Russian Federation and Ukraine are provided by affiliated companies ČKD ELEKTROPROM (Ekaterinburg, Russia) and ČKD ELEKTROMASH (Kiev, Ukraine). 11

6. References Customer Country Parameters Year Application Output DC voltage Apparent power Volgocemmash Russia 35 kv 70 MVAr 2013 Set SVC POLDI Hütte Metallurgical plant BMZ Belarus Metallurgical plant Traction substation TT Mýto VTŽ Chomutov, division Sandvik 22 kv 16 MVAr 2012 Set SVC Belarus 33 kv 32 MVAr 2012 Set SVC 27,5 kv 2011 Set SVC 6 kv 1 MVAr 2010 Reconstruction SVC Pavlogradugol, mine Ukraine 6,3 kv 2,5 MVAr 2010 Set SVC Evrochem- Volgakalij Russia 10,5 kv 2010-2012 2x set SVC Traction substation TT Klatovy Traction substation TNS Planá u Mariánských Lázní Traction substation TNS Zdice OKD, Mine Darkov, o.z. Traction substation TT Jindřichov Traction substation TT Benešov u Prahy 27,5 kv 2009 Set SVC without transformer 27,5 kv 2009 2 x set SVC 27,5 kv 2009 2 x set SVC 27,5 kv 2009 Reconstrucion of control system SVC 27,5 kv 2009 Set SVC without transformer 25 kv 2009 Set SVC In 2012. at Belarusian Metallurgical Plant was placed set SVC for installation Ladle-furnace, 33 kv, 32 MVAr 12

ČKD ELEKTROTECHNIKA, a.s. Kolbenova 936/5e 190 00 Prague 9 Republic Phone: +420 226 544 200 Fax: +420 226 544 300 E-mail: info@ckde.cz Web: http://www.ckdelektrotechnika.cz