ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Similar documents
MESG 12 / 17.5 / 24 / 36 KV

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

NXPLUS C Single busbar. Maintenance-free for lifetime

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

with Vacuum Circuit Breaker HAF

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Modular medium-voltage switchgear. NorMax

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Metal Clad Switchgears

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

UniGear. Technical Guide

Benefits, typical uses

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

8DJ. Maintenance-free for lifetime

Power IT Air Insulated Cubicle Uniswitch

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

COMPACT SUBSTATION GUIDE

CBGS-0. Medium voltage distribution

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

ZX-Family Gas-insulated medium voltage switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

PIX-H Metal-clad switchgear up to 17.5kV

Content. Uniswitch. 1. Design philosophy Applications Switchgear construction Cubicle types... 9

with Vacuum Circuit Breaker HAF

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Medium voltage compact switchgears. rated voltage 12 and 25 kv rated current 400 and 630 A

Medium voltage switchgear type W 12. rated voltage 12 kv rated current 630 A

Air-insulated medium-voltage secondary distribution switchgear

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

CGMCOSMOS Fully gas-insulated modular and compact (RMU) system Up to 24 kv

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Switchgear Type 8DJH 36 for Secondary

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

CPG.0 Single busbar gas-insulated cubicles

the safe, reliable, and efficient choice for MV switchgear

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

UniSec licensed by ABB, produced by Metix WHERE ENERGY LIVES COMPLETE SOLUTIONS

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

Gas Insulated Metal-clad Switchgear, HMGS!

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

Switchgear Type 8DJH for Secondary Distribution Systems up to 24 kv, Gas-Insulated

Air-insulated medium voltage switchgear metal-enclosed type-tested factory-assembled withdrawable-unit design 12 kv / 24 kv

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

cgm.3 2 ry Distribution Switchgear

ZX2 Gas-insulated medium voltage switchgear

Fixed-Mounted Circuit-Breaker Switchgear Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

Extensible Unit - VCE2a

Metal Clad Air Insulated Switchgear

ga-gae630 2 ry Distribution Switchgear

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SABRE VRN2a ENGINEERING BRILLIANT SOLUTIONS

Unitole UP kv Primary substations Motor control centres

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

Innovac SVS/08 - SVS/ kv modular switchgear

Persian Tajhiz Niroo Engineering Co.

COMPACT AND EXTENSIBLE RING MAIN UNIT. insulated Ring Main Unit with load break switch or integrated vacuum circuit breaker

Medium Voltage Distribution PI 100. up to 24 kv Air-insulated circuit-breaker switchgear for primary distribution. System configuration

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

132/11 kv, 25 MVA MOBILE SUBSTATION

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT


Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Medium voltage NEX switchgear Withdrawable circuit breaker. Quite simply efficient

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Key features. DESIGNS: - Conservator type - Hermetically sealed

USN. Metal-clad type switchgear. Technical information

Persian Tajhiz Niroo Engineering Co.

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

Unitole UP kv Primary substations Motor control centres

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

MCSG 12kV / A

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

PT Guna Era Manufaktura. Catalogue GAE TPS \ Medium Voltage Switchgear 12kV - 24kV \ M GAE TPS. Medium Voltage Switchgear 12kV - 24kV

AIR INsULATeD switchgear >> PIX. up to 24 kv. Air-insulated switchgear with vacuum circuit-breaker. system configuration.

Transcription:

ATR-MIX METAL ENCLOSED SWITCHGEAR 12-24-36kV 630-1250 A 16-20-25 ka

INDICE 01 GENERAL DESCRIPTION TECHNICAL DATA UNIT TYPES TYPICAL UNITS - ATR 01 TYPICAL UNITS - ATR 02 TYPICAL UNITS - ATR 03 TYPICAL UNITS - ATR 04 TYPICAL UNITS - ATR 05 TYPICAL UNITS - ATR 06 TYPICAL UNITS - ATR 07 TYPICAL UNITS - ATR 08 TYPICAL UNITS - ATR 09 TYPICAL UNITS - ATR 10 INSTALLATION DERATING FOR ALTITUDE Pag. 02 Pag. 04 Pag. 05 Pag. 06 Pag. 07 Pag. 08 Pag. 09 Pag. 10 Pag. 11 Pag. 12 Pag. 13 Pag. 14 Pag. 15 Pag. 16 Pag. 17

02 GENERAL DESCRIPTION GENERAL - ATR-MIX series Metal enclosed units which are produced by our company,have been designed and tested to be used for all energy distribution systems till 36 Kv - Modular Metal Enclosed units appear as the optimal solution with their easiness of taking operation by means of their moduler structure and with their modular appositi on characteristic for companies - ATR-MIX series Metal enclosed unit are manufactured according to IEC Standards - Optimal dimensions - Long term technical solutions for various applications - High level personnel safety APPLICATIONS - Manufacturing industry - Secondary electricy distribution networks - Shopping malls - MV / LV distribution transformer substations - Small size power plants - Wind power plants - Airports, hospitals, holiday villages Enclosure of cubicle is 2 galvanized steel sheet. If desired al-zinc is also possible. No welding during the assembling of the structure. SAFETY - There is a survelliance window on the front cover of every cubicle to check inside the cubicle without opening the door / cover - The door / cover of the accessible compartments is mechanically interlocked with the earthing switches - High voltage indication system in each cubicle STANDARDS - Compliance with standards IEC 62271-200 - Classification; (according to IEC 62271-200 ) - Classification of service contunity: LSC 2A - Classification of the partitions: ( Partition: Insulated ) - Classification of arc proofing: IAC A (FL), IAC A (FLR)

GENERAL DESCRIPTION 03 STRUCTURES 1 3 4 2 1 2 3 4 Busbars compartment Cable compartment Low voltage compartment Operating mechanism compartment 1 - Busbars compartment Busbars compartment is located on the top of the cubicle. It contains the main busbars interconnecting cubicles and also: - Tool based accessible compartment with regard to accessibility, (it means that is not possible to open the covers without using aproper tool) - Withstand to interl arc - IP 3X protection degree 2 - Cable compartment Cable compartment is located on the bottom of the cubicle. It contains switching devices, metering transformers., HV fuses, earthing devices, support insulators according to the functiol type of the cubicle. Incoming / outgoing MV cable connection of the cubicle is made in this compartment. The door has an inspection window. And also; - Procedure based accessible compartment with regard to accessibility, (it means that it is possible to open the covers using a proper tool) - Withstand to interl arc - IP 3X protection degree 3 - Low voltage compartment Low voltage compartment is located on the front - top of the cubicle having IP3X protection degree. According to the functiol type of the cubicle, it contains, protection relays, LV fuses, metering instruments, auxilary relays, miniature circuit breakers, termil arrays, AC/DC supply, etc. 4 - Operating mechanism compartment Operating mechanism compartment is located on the front of the cubicle. According to the functiol type of the cubicle it contains; disconnector mechanism, switch-disconnector mechanism and same interlocking metal parts. Circuit breakers has own mechanism, separately. All metal parts of the operating mechanism are protected agains to corrosion.

04 TECHNICAL DATA Rated voltage kv 12 24 36 Rated lighting impulse withstand voltage - Across phases and phase to earth kv 75 125 170 - Across the isolating distance kv 85 145 195 Rated power frequency withstand voltage - Across phases and phase to earth kv 28 50 70 - Across the isolating distance kv 32 60 80 Rated frequency Hz 50/60 50/60 50/60 Rated current - Busbar 630 / 1250 630 / 1250 630 / 1250 - Feeder / branch 630 / 1250 630 / 1250 630 / 1250 Rated short time withstand current ka 16 16 16 ka 20 20 20 ka 25 25 25 Rated peak withstand current ka 40-50-62,5 40-50-62,5 40-50-62,5 Rated duration of short circuit s 1:3 1:3 1:3 Interl Arc current, 1 s ka 16 16 16 Interl arc class A(FLR)/A(FL) A(FLR)/A(FL) A(FLR)/A(FL) Partitions class PI PI PI Loss of the service continuity LSC2A LSC2A LSC2A Degree of protection, enclosure IP3X IP3X IP3X Degree of protection, partitions IP3X IP3X IP3X Ambient temperature - Maximum value C +40 +40 +40 - Maximum value of 24 h mean C +35 +35 +35 - Minimum value C -5-5 -5 Altitude above sea level m 1000 1000 1000

UNIT TYPES 05 Type ATR - 01 Type ATR - 02 Type ATR - 03 Type ATR - 04 Type ATR - 05 Switch Unit Fuse Switch Combition Unit Switch Unit and Metering Circuit Breaker Unit Bus Tie - Riser Unit with Switch Type ATR - 06 Type ATR - 07 Type ATR - 08 Type ATR - 09 Type ATR - 10 Bus Tie - Riser Unit Incoming Cable Connection Unit Bus Riser Unit Metering Unit Busbars Metering Unit

06 TYPICAL UNITS ATR-01 B ATR - 01 A C 1-3 Position SF6 load break switch(open - closed - earthed) 2 - Operating mechanism with mechanical position indication 3 - Voltage indicator device 4 - Heather 5 - Earthing bar 6 - Busbars 7 - Interlocking unit 8 - Auxiliary contacts for close (2NO+2NC) and earth (2NO+2NC) position 9 - Cable entry with cable support Optiol equipments 1 - Remote control with cable (Opening and closing) 2 - Remote control without cable (Opening and closing) 3 - Gas density indication 4 - Gas density indication with alarm contact 5 - Motor operation device 6 - Cable fault indication device 7 - Surge arresters 8 - Current transformers 9 - Arc-gas channel RATED VOLTAGE KV 12 24 36 A - Width 375 375-500 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 185 185-240 260 Width with pack 420 420-550 1000 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

ATR-02 TYPICAL UNITS 07 B ATR - 02 A C 1-3 Position SF6 load break switch(open - closed - earthed) 2 - Operating mechanism with mechanical position indication 3 - Earthing switch 2 ka 4 - Fuse 5 - Voltage indicator device 6 - Heather 7 - Earthing bar 8 - Busbars 9 - Interlocking unit 10 - Auxiliary contacts for close (2NO+2NC) and earth (2NO+2NC) position 11 - Cable entry with cable support Optiol equipments 1 - Remote control with cable (Opening and closing) 2 - Remote control without cable (Opening and closing) 3 - Gas density indication 4 - Gas density indication with alarm contact 5 - Motor operation device 6 - Voltage transformers 7 - Cable fault indication device 8 - Arc-gas channel RATED VOLTAGE KV 12 24 36 A - Width 375 375-500 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 185 185-275 295 Width with pack 420 420-550 1000 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

08 TYPICAL UNITS ATR-03 B ATR - 03 A C 1-3 Position SF6 Disconnector(open - closed - earthed) 2 - Operating mechanism with mechanical position indication 3 - Voltage transformers 4 - Fuse 5 - Voltage indicator device 6 - Heather 7 - Earthing bar 8 - Busbars 9 - Interlocking unit 10 - Auxiliary contacts for close (2NO+2NC) and earth (2NO+2NC) position Optiol equipments 1 - Earthing switch 2 - Gas density indication 3 - Gas density indication with alarm contact 4 - Cable fault indication device 5 - Arc-gas channel RATED VOLTAGE KV 12 24 36 A - Width 375 375-500 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 230 230-250 320 Width with pack 420 420-550 1000 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

ATR-04 TYPICAL UNITS 09 ATR - 04 B A C 1-3 Position SF6 Disconnector(open - closed - earthed) 2 - Operating mechanism with mechanical position indication 3 - Circuit breaker, vacuum or SF6 type 4 - Current transformers (toroidal orstandard type ) 5 - Over current protection relay 6 - Earthing switch 16 ka 7 - Voltage indicator device 8 - Heather 9 - Earthing bar 10 - Busbars 11 - Interlocking unit 12 - Auxiliary contacts for close (2NO+2NC) and earth (2NO+2NC) position 13 - Cable entry with cable support Optiol equipments 1 - Remote control with cable (Opening and closing) 2 - Remote control without cable (Opening and closing) 3 - Gas density indication 4 - Gas density indication with alarm contact 5 - Voltage Transformers 6 - Cable fault indication device 7 - Surge arresters 8 - Arc-gas channel RATED VOLTAGE KV 12 24 36 A - Width 1000 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 400 400-420 480 Width with pack 850 850 1200 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

10 TYPICAL UNITS ATR-05 ATR - 05 B A C 1-3 Position SF6 Disconnector(open - closed - earthed) 2 - Operating mechanism with mechanical position indication 3 - Circuit breaker, vacuum or SF6 type 4 - Current transformers (toroidal orstandard type ) 5 - Over current protection relay 6 - Voltage indicator device 7 - Heather 8 - Earthing bar 9 - Busbars 10 - Interlocking unit 11 - Auxiliary contacts for close (2NO+2NC) and earth (2NO+2NC) position Optiol equipments 1 - Remote control with cable (Opening and closing) 2 - Remote control without cable (Opening and closing) 3 - Gas density indication 4 - Gas density indication with alarm contact 5 - Voltage Transformers 6 - Cable fault indication device 7 - Arc-gas channel RATED VOLTAGE KV 12 24 36 A - Width B - Height 1600 1600-1950 C - Depth 940 940-980 Gross Weight kg 480 480-500 Width with pack 850 850 Depth with pack 1070 1100 Height with pack 1 1-2150

ATR-06 TYPICAL UNITS 11 ATR - 06 B A C 1. 3 Position SF6 Disconnector (open - closed - earthed) 2 - Operating mechanism with mechanical position indication 3 - Circuit breaker, vacuum or SF6 type 4 - Current transformers (toroidal or standard type ) 5 - Over current protection relay 6 - Voltage indicator device 7 - Heather 8 - Earthing bar 9 - Busbars 10 - Interlocking unit 11 - Auxiliary contacts for close (2NO+2NC) and earth (2NO+2NC) position Optiol equipments 1 - Remote control with cable (Opening and closing) 2 - Remote control without cable (Opening and closing) 3 - Gas density indication 4 - Gas density indication with alarm contact 5 - Voltage Transformers 6 - Cable fault indication device 7 - Arc-gas channel RATED VOLTAGE KV 12 24 36 A - Width B - Height 1600 1600-1950 C - Depth 940 940-980 Gross Weight kg 420 420-440 Width with pack 850 850 Depth with pack 1070 1100 Height with pack 1 1-2150

12 TYPICAL UNITS ATR-07 B ATR - 07 A C 1 - Voltage indicator device 2 - Busbars 3 - Earthing bar 4 - Heater 5 - Interlocking unit Optiol equipments 1 - Earthing switch 2 - Voltage transformers 3 - Current transformers RATED VOLTAGE KV 12 24 36 A - Width 375 375-500 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 150 150-210 230 Width with pack 420 420-550 1000 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

ATR-08 TYPICAL UNITS 13 B ATR - 08 A C 1 - Bushings 2 - Voltage indicator device 3 - Heather 4 - Earthing bar 5 - Busbars 6 - Interlocking unit Optiol equipments 1 - Voltage transformers 2 - Current transformers 3 - Earthing SwitchBus RATED VOLTAGE KV 12 24 36 A - Width 500 500 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 210 210-220 240 Width with pack 550 550 1200 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

14 TYPICAL UNITS ATR-09 B ATR - 09 A C 1-3 Position SF6 load break switch(open - closed - earthed) 2 - Operating mechanism with mechanical position indication 3 - Voltage transformers 4 - Current transformers 5 - Bushing 6 - Voltage indicator device 7 - Heather 8 - Earthing bar 9 - Busbars 10 - Interlocking unit 11 - Auxiliary contacts for close (2NO+2NC) and earth (2NO+2NC) position Optiol equipments 1 - Remote control with cable (Opening and closing) 2 - Remote control without cable (Opening and closing) 3 - Gas density indication 4 - Gas density indication with alarm contact 5 - Motor operation device 6 - Cable fault indication device 7 - Arc-gas channelmetering RATED VOLTAGE KV 12 24 36 A - Width 1000 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 240 240-250 290 Width with pack 850 850 1200 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

ATR-10 TYPICAL UNITS 15 ATR - 10 B A C 1 - Bushings 2 - Current Transformers (toroidal or standard) 3 - Voltage transformers 4 - Busbars 5 - Earthing bar 6 - Aeter,Voltmeter 7 - Heather 8 - Interlocking unit 9 - Voltage indicator device Optiol equipments 1 - Energy meter 2 - Hv fuses 3 - Surge arresters RATED VOLTAGE KV 12 24 36 A - Width 1000 B - Height 1600 1600-1950 2250 C - Depth 940 940-980 1400 Gross Weight kg 210 210-220 240 Width with pack 850 850 1200 Depth with pack 1070 1100 1550 Height with pack 1 1-2150 2450

16 INSTALLATION Fuses choice for transformer protection Potenza nomile del trasformatore in kva Tensione nomile fusibile kv 24 36 50 75 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 Corrente nomile del fusibile in A 6 6 10 10 16 16 20 25 32 40 50 63 63 100 100 100 4 6 10 10 10 16 16 20 25 25 32 50 63 63 63 63 Installation room Fronte Fronte Versione quadro A () B () C () D () Standard 50 (3) 100 (3) 50 1550 (1) Arc proof 600 (2)(3) 100 (3) 50 1550 (1) Interl arc on the front 600 100 100 1550 (1) (1) For circuit-breaker units, D = 1200. (2) For lower values, please consult us. (3) When the units are complete with low voltage compartments (control auxiliaries) and the rear sheets are against the wall, distances A and B must be large enough to allow a person to pass through to carry out main busbar assembly.

DERATING FOR ALTITUDE 17 Derating for altitude > 1000 meter over sea level (example) - Installation altitude 2000 m - Working at rated voltage of 7 kv rms - Power frequency 20kV rms - Lighting impulse 50 kvp - Factor Ka = 1.13 (see graph) Those factors can be calculated by the IEC 60071-2 Stds par.4.2.2 with the following equation: Ka = e m (H.1000)/8150 Considering the above parameters, the switchgear must bear (on test at altitude zero i.e. on sea level): -Power frequency: 20 x 1,13 = 22,6 kvrms -Lighting impulse: 50 x 1,13 = 53,5 kvp. From the above it is understood that for installations at altitude of 2000 meters over sea level, with working voltage of 7 kv, it is necessary to foresee a switchgear with rated voltage of 12kV and with insulation lever at power frequency of 28kV rms with 60/75 kvp as lighting impulse voltage. Ka 1,50 m=1 1,40 1,30 1,20 1,10 1,10 1000 1500 2000 2500 3000 3500 4000 H H meter altitude m constant value equal to 1 for power frequency, lighting impulse and phase-phase

FILIALE TECNICO/COMMERCIALE - TECHNICAL/SALES MILAN BRANCH 20066 Melzo (MI) Italia - Viale Svezia,7 Tel. +39 02 9573 7811 - Fax +39 02 9573 2316 email: sales@crtsgroup.com SEDE ESTERA SUD AMERICA - FOREIGN OFFICE SOUTH AMERICA Ave 7ma 6203, Miramar - Haba - CUBA Tel.: +53 720 79077 Fax : +53 720 79079 email : crts@crts.co.cu SEDE LEGALE E AMMINISTRATIVA - HEADQUARTER AND ADMINISTRATIVE 00193 Roma (RM) Italia - Via Crescenzio, 82 Tel. +39 06 687 4730 - Fax +39 02 9573 2316 email: info@crtsgroup.com UFFICIO ASSOCIATO NORD AFRICA - ASSOCIATE OFFICE NORTH AFRICA Ieuble cercle des bureaux 4 étage bureau N11 - centre Urbain nord Tunis - Tunisia Tel. 216 71 822 411 - Fax. +216 712 30825 email : tunis@crtsgroup.com LIBYA TRIPOLI BRANCH Airport Road - Tripoli - Libya Tel. +218214918840 - Fax. +218214918840 email: libya@crtsgroup.com