Translation of the Original Operating Manual. Manual Powder Spray Gun PEM-X1. Version 09/2012. II 2D 2mJ P_01660

Similar documents
Translation of the Original Operating Manual. Automatic Powder Spray Gun PEA-C4XL-S. Version 03 / II 2 D EEx 2mJ 85 C P_02330

Translation of the Original Operating Manual

Electrostatic Control Unit

RediCoat by Nordson. Hopper and VBF Dolly Systems. Customer Product Manual Part A Issued 10/07

EasySelect-Cup Manual Powder Gun

Operating instructions Accu Jet

Turbocharger / VTR..0, VTR..1 Original assembly instructions English

Electrostatic Air Spray Gun

PG 1-A Automatic Powder Gun

Operating Instructions and Spare Parts List. PG 1-Cup Gun. Issued 09/98

Translation of the Original Operating Manual. Pneumatic Double Diaphragm Pump. II 2G c IIB T4. Version 09/2016 B_06420 B_05369

Electrostatic Air Spray Gun

KeContact P20. User manual

HST -LS Interlocking device (Translation of Original Manual)

Application cup for OptiFlex 2 GM03 manual powder gun

Oil-free piston compressors KK and piston vacuum pumps KV

Turbocharger / A100-L Original assembly instructions English

Operating instructions

Tribo Manual Spray Gun

Assembly and Maintenance Manual Type ASNU

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Printed: Doc-Nr: PUB / / 000 / 00

Operating Instructions

Operating manual GA 250AL GA 400AL. Edition 07 / Automatic Airless Spraygun. II 2GX (Atex 95)

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Turbocharger / TPS-H Original assembly instructions English

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

USE and MAINTENANCE INSTRUCTION MANUAL AZ3 HTE2 AZ3 HTE2 HVLP GRAVITY. SPRAY GUN Series. en it fr es pt de se

Angle seat valve with diaphragm actuator VZXA-...-M

60 / 50 / 25L / L-D1

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Assembly and Maintenance Manual Type AS

Operating Instructions CYR52

Type 6213 EV, 6281 EV

2025 Digiflow Airfluid Manual Powder System. Operating Manual

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

PG 2-A Automatic Powder Gun (and PG 2-AX Automatic Powder Gun for Quick Colour Changes)

Instruction Manual. Ex-Time 40 / 50

Installation manual wall-mounted distributor

Assembly and Maintenance Manual Type RSBW

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

Industrial Solutions. Corona and Tribo Guns. Powder manual and automatic guns. Efficient and economical Perfect application efficiency Light and handy

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Turbocharger / TPL-B Original assembly instructions English

AquaCoat AirCoat spray system for non-combustible liquids

Installation manual portable distributors

EasySelect GM01-E Manual Powder Gun

USE and MAINTENANCE INSTRUCTION MANUAL W-300 W-300 WB LPH-300 GRAVITY. SPRAY GUN Series. en it fr es pt de se

Exchange of rollers from the XTS-Mover

Swiveling gripper finger GFS 16-40

Operating Instructions

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Translation of the original Operating manual. AquaCoat air spray system for non-combustible liquids. AquaCoat Air -LDG20 -ZIP S -VM 2900W

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

Prodigy HDLV Pump. Customer Product Manual Part A02

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

OWNER'S MANUAL RED LINE EZ50

Angle seat valve with piston actuator VZXA-...-K

Econo-Coat Manual Powder Spray Gun

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

These installation and maintenance instructions must be read in full and completely understood before the installation!

Installation and Operating Instructions Magnetic Vibrator MR 1

Micro Diaphragm Gas Sampling Pumps

Pressure relief valve

Uninterruptible power supply Supply MEg101.4

SPARK PLUG CLEANING KIT OPERATING MANUAL

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Prodigy HDLV Generation II Pump Panel

Safety information on VIKING type AAI lithium-ion batteries for use in imow robotic mowers

Operating instructions Solenoid interlock EX-AZM About this document. Content

Off-line filter system

Operating Manual. Automatic spray gun AGR-09 mini, AGR-09 mini with needle stroke limitation for low-pressure atomization

Angle seat valve with piston actuator VZXA-...-K

Operator s and Maintenance Manual

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Manual coating equipment OptiFlex 2 B

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

OPERATING MANUAL. Robot Gun Mount T2, T4

General operating manual for assembly, commissioning and maintenance of valves and hydraulic manifolds

Ex m Solenoid Operator Type 0519

RO Automatic trailer coupling. Repair instructions. 5KPVM02000 Towing Hitch Automatic Rockinger RO244A

C3 Operating Instructions

Mod: KLD6-12/35XLAS-N

MPS 1-F / MPS 2-F Manual Powder System

Translation of the original Operating manual EPG Edition 06 / Electrostatic Control Unit for E-Static automatic sprayguns

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Operating and Maintenance Manual. for. HADEF overhead crane. as jointed crane TA

OptiGun 2-AE Automatic Powder Gun (GA02)

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

AUTOMATIC AIRSPRAY GUN

DIAPHRAGM LIQUID PUMP NF 1.30

English. Instruction and operation manual S 212. Dew point sensor

Installation, Operation, and Maintenance Manual

Operating Instructions Flexdip CYA112

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

SCOPELITE TIMING LIGHT OPERATING MANUAL

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Transcription:

Translation of the Original Operating Manual Manual Powder Spray Gun Version 09/2012 P_01660 0102 II 2D 2mJ

Contents 1 GENERAL INFORMATION 6 1.1 Preface 6 1.2 Warnings, Notes and Symbols in these Instructions 6 1.3 Languages 7 1.4 Abbreviations 7 2 CORRECT USE 8 2.1 Device Type 8 2.2 Correct Use 8 2.3 For Use in Potentially Explosive Areas 8 2.4 Safety Parameters 8 2.5 Processing Materials 9 2.6 Reasonably Foreseeable Misuse 9 2.7 Residual Risks 9 3 IDENTIFICATION 10 3.1 Explosion Protection Identification 10 3.2 Permissible Device Combinations 10 4 GENERAL SAFETY INSTRUCTIONS 11 4.1 Safety Instructions for the Operator 11 4.1.1 Electrical Devices and Operating Equipment 11 4.1.2 Personnel Qualifications 11 4.1.3 A Safe Work Environment 11 4.2 Safety Instructions for Staff 12 4.2.1 Safe Handling of WAGNER Powder Spray Devices 12 4.2.2 Grounding the Device 12 4.2.3 Material Hoses 12 4.2.4 Cleaning 13 4.2.5 Handling Powder Paints 13 4.3 Information about Harmless Discharges 14 4.4 Protective and Monitoring Equipment 15 5 DESCRIPTION 16 5.1 Design of the Spray Gun 16 5.2 Functioning of the Spray Gun 16 5.3 Technical Data 17 5.3.1 Dimensions 18 5.4 Permitted Accessories 19 5.5 Scope of Delivery 19 6 ASSEMBLY AND COMMISSIONING 20 6.1 Qualification of the Assembly/Commissioning Staff 20 6.2 Storage Conditions 20 6.3 Installation Conditions 20 6.4 Preparing the Spray Gun 21 6.4.1 Selection of the Suitable Nozzle System 21 6.5 Connecting the Spray Gun 23 6.6 Grounding 25 6.6.1 Grounding the Powder Coating System 26 3

Contents 7 OPERATION 27 7.1 Qualification of the Operating Staff 27 7.2 Safety Instructions 27 7.3 Optimizing the Powder Cloud for Coating 28 7.3.1 Recommended Settings for Total Air Volume 28 7.4 Switching off the Spray Gun 29 7.5 Adjustment of Powder Quantity 30 7.6 "Double Click" Recipe (High Dynamic Remote) 31 7.7 Reproducible Setting of the Nozzle Position 32 8 CLEANING AND MAINTENANCE 33 8.1 Cleaning 33 8.1.1 Cleaning Staff 33 8.1.2 Safety Instructions 33 8.1.3 Cleaning Procedures 34 8.2 Maintenance 35 8.2.1 Maintenance Staff 35 8.2.2 Safety Instructions 35 8.2.3 Maintenance Procedures 36 8.2.4 Replacing the Spray Gun 37 8.3 Removing the Flat Spray Nozzle 38 8.4 Fitting the Flat Spray Nozzle 39 8.5 Removing the Round Spray Nozzle 40 8.6 Fitting the Round Spray Nozzle 41 8.7 Replacing the Protective Wedge 42 8.8 Changing from Flat Spray Nozzle to Round Spray Nozzle 44 8.9 Mounting the Corona-Star 46 8.10 Replacing the Suspension Hook 47 9 INSPECTIONS IN ACCORDANCE WITH DIN EN 50177: 2010 48 9.1 Overview of Inspections 49 10 DISASSEMBLY AND DISPOSAL 52 10.1 Disassembly 52 10.2 Disposal 52 11 TROUBLESHOOTING AND RECTIFICATION 53 12 ACCESSORIES 55 12.1 Flat Spray Nozzle 55 12.2 Deflector Cone 55 12.3 Electrode Holder 55 12.4 Hose Take-Up 56 12.5 Retrofit Set Corona-Star 56 12.6 Wedge Tool 56 12.7 Nozzle Extension X1 VL 150/300 57 12.8 Powder Hose 57 12.9 Wall Mount 58 12.10 Powder Measuring Adapter 59 4

13 SPARE PARTS 60 13.1 How to order Spare Parts? 60 13.2 Corona Manual Spray Gun 61 13.3 Electrode Holder X1 R 62 14 DECLARATION OF WARRANTY AND CONFORMITY 63 14.1 Important Notes on Product Liability 63 14.2 Warranty Claim 63 14.3 Declaration of Conformity 64 14.4 EC Type Examination Certificate 65 14.5 FM Approval 68 5

1 GENERAL INFORMATION 1.1 PREFACE The operating manual contains information about safely operating, maintaining, cleaning and repairing the device. The operating manual is part of the device and must be available to the operating and service staff. The operating and service staff should be instructed according to the safety instructions. The device may only be operated in compliance with this operating manual. This equipment can be dangerous if it is not operated according to the definitions in this operating manual. 1.2 WARNINGS, NOTES AND SYMBOLS IN THESE INSTRUCTIONS Warning instructions in this operating manual highlight particular dangers to users and device and state measures for avoiding the hazard. These warning instructions fall into the following categories: Danger - immediate risk of danger. Non-observance will result in death, serious injury and serious material damage. DANGER This information warns you of a hazard! Possible consequences of not observing the warning instructions. The signal word indicates the hazard level. The measures for preventing the hazard and its consequences. Warning - possible imminent danger. Non-observance may result in death, serious injury and serious damage to property. WARNING This information warns you of a hazard! Possible consequences of not observing the warning instructions. The signal word indicates the hazard level. The measures for preventing the hazard and its consequences. Caution - a possibly hazardous situation. Non-observance may result in minor injury. CAUTION This information warns you of a hazard! Possible consequences of not observing the warning instructions. The signal word indicates the hazard level. The measures for preventing the hazard and its consequences. Notice - a possibly hazardous situation. Non-observance may result in damage to property. NOTICE This information warns you of a hazard! Possible consequences of not observing the warning instructions. The signal word indicates the hazard level. The measures for preventing the hazard and its consequences. Note - provides information about particular characteristics and how to proceed. 6

1.3 LANGUAGES The this operating manual is available in the following languages: German 2326019 English 2326020 French 2326021 Italian 2326022 Spanish 2326023 1.4 ABBREVIATIONS Piece Item Marking in the spare parts lists Number Spare part 7

2 CORRECT USE 2.1 DEVICE TYPE Powder spray guns for manual coating of grounded work pieces 2.2 CORRECT USE The manual powder spray gun is designed for the electrostatic coating of work pieces with organic powders. Any other form of use is considered not intended use. Wagner disclaims liability for any damage resulting from not intended use. The spray gun may only be used in spray areas equipped in accordance with EN 50177 or under equivalent ventilation conditions. 2.3 FOR USE IN POTENTIALLY EXPLOSIVE AREAS This type A-P electrostatic powder spray gun is suitable for processing industrial powder paints for coating electrically conductive objects and can be used in potentially explosive atmospheres (zone 22). (See chapter 3.1 "Explosion Protection Identification"). 2.4 SAFETY PARAMETERS The powder hand gun is only suited to the application of powder paint. J. Wagner AG forbids any other use! The powder spray gun may only be operated under the following conditions if: the operating staff have previously been trained on the basis of this operating manual, the safety regulations listed in this operating manual are observed, the operating, maintenance and repair information in this operating manual is observed, the statutory requirements and accident prevention regulations standard in the country of use are observed. The manual powder spray gun may only be operated if all parameters are set and all measurements/safety checks are carried out correctly. 8

2.5 PROCESSING MATERIALS Types of powder which can be charged electrostatically Metallic powder 2.6 REASONABLY FORESEEABLE MISUSE The following is prohibited: Coating work pieces which are not grounded Unauthorized conversions and modifications to spray guns Processing liquid or similar coating materials Using defective components, spare parts or accessories other than those described in chapter 12 of this operating manual. The forms of misuse listed below may result in health issues and/or damage to property: Use of damp powder paint Incorrectly set values for powder discharge Incorrectly set electrostatic values Use of defective components and accessories Use for foodstuffs Use in the pharmaceutical sector Use with not permissible control units 2.7 RESIDUAL RISKS Residual risks are risks which cannot be excluded even in the event of correct use. If necessary, warning and prohibition signs at the relevant points of risk indicate residual risks. Residual risk Source Consequences Specific measures Lifecycle phase Skin contact with powder paints and cleaning agents Powder paint in air outside the defined working area Handling powder paints and cleaning agents Painting outside the defined working area Skin irritation, allergies Inhalation of substances hazardous to health Wear protective clothing Note safety data sheets Observe working and operating instructions Operation, maintenance, disassembly Operation, maintenance 9

3 IDENTIFICATION 3.1 EXPLOSION PROTECTION IDENTIFICATION Gun type: Manufacturer: CE: 0102 J. Wagner AG CH - 9450 Altstätten II 2D 2mJ 85 C Communautés Européennes 0102: Number of notified body which issues the recognition of quality assurance in production Ex: Symbol for explosion protection II: Device class II 2: Category 2 D: Ex-atmosphere dust 2mJ: Maximum ignition energy 2 mj 85 C: Maximum surface temperature The EC type examination certificate PTB 12 ATEX 5002 can be found in chapter 14.4. 3.2 PERMISSIBLE DEVICE COMBINATIONS WARNING Incorrect use! Risk of injury and damage to the equipment. Only connect original Wagner devices to the powder spray gun. The powder spray gun may only be connected to the control devices listed below: EPG-Sprint X with PI-F1/HiCoat ED-F powder injector EPG-Sprint with PI-F1* powder injector EPG S2 with PI-F1* powder injector * The remote control function of the spray gun is not available when using these control units. 10

4 GENERAL SAFETY INSTRUCTIONS 4.1 SAFETY INSTRUCTIONS FOR THE OPERATOR Keep this operating manual to hand near the unit at all times. Always follow local regulations concerning occupational safety and accident prevention. 4.1.1 ELECTRICAL DEVICES AND OPERATING EQUIPMENT To be provided in accordance with the local safety requirements with regard to the operating mode and ambient influences. May only be maintained by skilled electricians. Must be operated in accordance with the safety regulations and electrotechnical regulations. Must be repaired immediately in the event of problems. Must be put out of operation if they pose a hazard. Must be de-energized before work is commenced on active parts. Secure the device against being switched back on without authorization. Inform staff about planned work. Observe electrical safety regulations. 4.1.2 PERSONNEL QUALIFICATIONS Ensure that the device is operated and repaired only by trained persons. 4.1.3 A SAFE WORK ENVIRONMENT The floor in the working area must be electrostatically conductive (measurements according to EN 1081 and EN 61340-4-1). The footwear worn by the operators must comply with the requirements of EN ISO 20344. The measured insulation resistance must not exceed 100 MΩ (megaohms). The protective clothing, including gloves, must comply with the requirements of EN ISO 1149-5. The measured insulation resistance must not exceed 100 MΩ (megaohms). The powder release must be electrically interlocked with the powder spray system's exhaust air equipment. Excess coating material (overspray) must be collected up safely. Ensure that there are no ignition sources such as naked flames, sparks, glowing wires or hot surfaces in the vicinity. Do not smoke. Provide sufficient numbers of suitable fire extinguishers and ensure that they are serviceable. The operating company must ensure that the average concentration of powder paint in the air does not exceed 50% of the lower explosion limit (LEL = max. permitted concentration of powder to air). If no reliable LEL value is available, the average concentration must not exceed 10 g/m³. 11

4.2 SAFETY INSTRUCTIONS FOR STAFF Always follow the information in these instructions, particularly the general safety instructions and the warning instructions. Always follow local regulations concerning occupational safety and accident prevention. Under no circumstances may people with pacemakers enter the area where the high-voltage field between the spray gun and the work piece to be coated builds up! 4.2.1 SAFE HANDLING OF WAGNER POWDER SPRAY DEVICES Do not point spray guns at people. Before all work on the device, in the event of work interruptions and malfunctions: - Switch off the energy/compressed air supply. - Lock spray guns against actuation. - Relieve pressure on spray guns and device. - In the event of malfunctions: Identify and correct the problem, proceed as described in chapter "Elimination of Faults". 4.2.2 GROUNDING THE DEVICE The electrostatic charge may, in certain cases, give rise to electrostatic charges on the device. In the event of discharge, this may result in the formation of sparks or flames. Ensure that the device is grounded before each coating process. Ground the work pieces to be coated. Ensure that all persons inside the working area are grounded, e.g. by wearing electrostatically conductive shoes. The function of grounding cables must be checked regularly (see EN 60204). 4.2.3 MATERIAL HOSES Only use original Wagner powder hose. 12

4.2.4 CLEANING Before starting cleaning or any other manual work, the high-voltage in the spray area must be shut down and locked to prevent it from being switched back on! Lock the supply of compressed air and decompress system. Secure the device against being switched back on without authorization. Use only electrically conducting and grounded containers for cleaning liquids. Preference should be given to non-flammable cleaning fluids. Flammable cleaning fluids may only be used if, once the high-voltage has been switched off, all parts carrying high-voltage are discharged to a discharge energy of less than 0,24 mj before they can be reached. Most flammable solvents have a firing power of around 24 mj or 60 nc. The cleaning agent's flash point must be at least 15 K above the ambient temperature. Only mobile industrial vacuum cleaners of design 1 (see EN 60335-2) may be used to remove dust deposits. 4.2.5 HANDLING POWDER PAINTS Take note of the processing regulations laid down by the manufacturer of the powder paint being used, when preparing or processing the powder. Take note of the manufacturer s notification and the relevant environmental protection regulations when disposing of powder paints. Take the prescribed safety measures, in particular wear of safety glasses and safety clothing and use protective hand cream if required. Use a mask or breathing apparatus if necessary. To ensure sufficient protection of health and the environment, only operate the device in a powder booth or at a spray wall with activated ventilation (exhaust air). 13

4.3 INFORMATION ABOUT HARMLESS DISCHARGES Nozzle Electrode Luminous discharge Work piece P_01698 With the high-voltage switched on, a luminous or corona discharge occurs at the electrode tip; this can only be seen in the dark. This physical effect can be seen when the electrode is brought near the grounded work piece. This luminous discharge does not involve any firing power and has no effect on system handling. When the electrode approaches the work piece, the control unit automatically reduces the high-voltage to a safe value. If you touch plastic parts of the spray gun with your finger, harmless discharges may occur due to the high-voltage field around the spray gun (so-called brush discharges). However, these do not contain any firing power. 14

4.4 PROTECTIVE AND MONITORING EQUIPMENT WARNING Incorrect use! Risk of injury and damage to the device. Protective and monitoring equipment must not be removed, modified or rendered unusable. Regularly check that they are working perfectly. If defects are detected on protective and monitoring equipment, the system must not be operated until these defects are remedied. To prevent electrostatic flashover, the cup nut for securing the nozzles is designed in a certain geometric shape. This shape, together with the shape of the flat spray nozzle or deflector cone sleeve, prevents the nozzles from coming loose unintentionally (see chapters 8.3, 8.5, 8.8). To ensure safety, only use genuine Wagner spare parts! 15

5 DESCRIPTION 5.1 DESIGN OF THE SPRAY GUN L A K B I E F D C H G F P_01663 A B C D E F G H I K L Designation Suspension hook Handle Electrical connection cable Powder hose connection Trigger lever Cap nut Round spray nozzle Atomizer air connection Flat spray nozzle Buttons to adjust the powder quantity Gun body 5.2 FUNCTIONING OF THE SPRAY GUN High-voltage is activated in the hand gun when the trigger is actuated. The powder supply and air supply to the gun are activated at the same time. The control unit must be switched off in order to lock the spray gun. To prevent electrostatic flashover, the cap nut for securing the nozzles is designed with a labyrinth. 16

5.3 TECHNICAL DATA Dimensions: Length/width/height see chapter 5.3.1 Weight 490 g; 1.08 lbs Electrical: Input voltage maximum of 22 Vpp Input current maximum of 0.9 A Frequency 19-30 khz Output voltage maximum of 100 kv DC max. Corona current 120 μa Polarity negative Construction type in accordance with EN 50050-2 Protection class IP 64 Pneumatic: Input air pressure (atomizer air volume) Powder output quantity maximum of 3 bar; 0.3 MPa, 43.51 psi maximum of 450 g/min; 0.99 lbs/min. Ambient conditions: Operating temperature range 5-45 C; 41-113 F Relative humidity < 75 % WARNING Outgoing air containing oil! Risk of poisoning if inhaled. Insufficient paint application quality. Make compressed air free from oil and water available (quality standard 3.5.2 according to ISO 8573.1) 3.5.2 = 5 μm / +7 C; 44.6 F / 0.1 mg/m³. Ambient conditions: If low-melting powders are used, the ambient temperature may have to be below 30 C; 86 F. Volume measures: for volumes specified in Nm³ (standard cubic meters). One standard cubic meter is one cubic meter of gas at 0 C and 1.013 bar. 17

5.3.1 DIMENSIONS A C B P_01662 Measurement mm inch A* 335/349 13.19/13.74 B 248 9.76 C 45 1.77 * with flat spray nozzle/with deflector cone 18

5.4 PERMITTED ACCESSORIES Only the accessories listed in the chapter "Accessories" of this operating manual may be connected to the powder spray gun. The accessories listed in the chapter "Accessories" were included in the EC type examination and are approved for use with the gun. 5.5 SCOPE OF DELIVERY Stk Order No. Designation 1 2322587 manual spray gun 1 --- Nozzle set The standard equipment includes: 1 2326024 Declaration of conformity 1 2326019 Operating manual German 1 see chapter 1.5 Operating manual in the local language 19

6 ASSEMBLY AND COMMISSIONING 6.1 QUALIFICATION OF THE ASSEMBLY/COMMISSIONING STAFF WARNING Incorrect installation/operation! Risk of injury and damage to the equipment. The commissioning staff must have the technical skills to safely undertake commissioning. The commissioning staff must be familiar with the provisions of European standards DIN EN 50050-2 and DIN EN 50177. When putting into operation and for all work, read and follow the operating instructions and safety regulations for the additionally required system components. 6.2 STORAGE CONDITIONS Until the point of installation, the powder coating gun must be stored in a dry location, free from vibrations and with a minimum of dust. The powder coating gun must be stored in closed rooms. The air temperature at the storage location must be between 5-45 C; 41-113 F. The relative air humidity at the storage location must not exceed 75%. 6.3 INSTALLATION CONDITIONS The air temperature at the installation site must be between 5-45 C; 41-113 F. Depending on the powder paint used, the maximum permissible ambient temperature for reliable operation can be significantly below +40 C; 104 F. The relative air humidity at the storage location must not exceed 75%. 20

6.4 PREPARING THE SPRAY GUN 6.4.1 SELECTION OF THE SUITABLE NOZZLE SYSTEM The process of changing from the flat spray nozzle to the deflector cone is described in chapter 8.8 "Changing from Flat Spray Nozzle to Round Spray Nozzle". You will find the article numbers of the different nozzles in chapter 12 "Accessories". Nozzle Application overview Powder cloud Flat spray nozzle Complex shapes Widely spread flat powder cloud P_01664 Deflector cone P_01665 Flat parts (slight window frame effect) Profiles Undercuts Wire goods Grid designs Small components Round powder cloud: Size of the powder cloud is dependent on the deflector plate diameter Nozzle Application Distance to work piece Powder discharge (mm) (g/min) Universal deep and complex shapes 120 300 50 300 P_01664 extensive work pieces 21

Deflector cone Application Distance to work piece (mm) R18 18 mm Smaller flat parts 100 300 P_01665 R25 25 mm Medium sized, flat parts 100 300 P_01666 R34 34 mm Large flat parts 100 300 P_01667 Output quantity [g/min] Overall air Feed air [%] 4.00 Nm³/h 5.00 Nm³/h 6.00 Nm³/h 50 140 170 210 60 200 240 260 70 250 270 300 80 300 320 350 90 330 360 380 100 370 400 420 The values have been determined by means of an injector PI-F1 and a powder hose 11 mm, length 5 m. These values have to be considered as reference values and depend on the characteristics of the powder and the status of the transport relevant pieces (e.g. injector). 22

6.5 CONNECTING THE SPRAY GUN WARNING Unintentional putting into operation! Risk of injury. Before any work on the device, in the event of work interruptions and malfunctions: Switch off the energy/compressed air supply. Decompress spray gun and device pressure. Secure the spray gun against actuation. In the event of malfunctions, remedy the fault as described in the "Troubleshooting" chapter. Procedure: 1. Switch off the high-voltage generation on the control unit. 2. Before connecting the spray gun, check that all components (such as the nozzle system and cap nut) are correctly fitted. 3. Connect electrical cable of spray gun to control unit. 4. Connect the powder feed hose to the spray gun and to the powder injector. 5. Connect the atomizing air hose to the spray gun and to the control unit. 23

Powder spray gun to the electrical connection on the control unit Control unit I O P_01668 red Atomizing air from the control unit blue Powder feed from the powder injector transparent Powder injector 24

6.6 GROUNDING DANGER No grounding! Risk of explosion and risk of electric shock. Electrostatic control units and the associated spray equipment may only be connected to mains supplies with a protective conductor connection (PE conductor)! WARNING Defective grounding will result in high levels of powder mist! Danger of poisoning. Insufficient paint application quality. Ground all device components. Ground the work pieces to be coated. For safety reasons, the control unit must be properly grounded. The ground connection to the energy supply (socket) takes the form of the mains connection cable's protective conductor, while that to the work piece / system is via the knurled screw on the rear of the control unit. Both connections are absolutely essential. If installed correctly as described above, the gun is grounded via the gun cable between the control unit and gun. To achieve optimum powder coating, a flawless grounding of the work piece is also necessary. A poorly grounded work piece causes: Dangerous electric charging of the work piece. Very poor wrap around. Uneven coating. Back-spray to the spray gun, i.e. contamination. Prerequisites for perfect grounding and coating are: Clean suspension of the work piece to be coated. Grounding of spraying booth, conveyor system and suspension by the customer in accordance with the operating instructions or the manufacturer's information. Grounding of all conductive parts within the working area. The grounding resistance of the work piece may not exceed 1 MΩ (megaohm). (Resistance to ground measured at 500 V or 1000 V). 25

The footwear worn by the operators must comply with the requirements of EN ISO 20344. The measured insulation resistance must not exceed 100 MΩ (megaohms). The protective clothing, including gloves, must comply with the requirements of EN ISO 1149-5. The measured insulation resistance must not exceed 100 MΩ (megaohms). Sparks between conveyor, conveyor hooks (hangers) and work piece can occur if electric contact points between conveyor, conveyor hooks (hangers) and work piece are not sufficiently cleaned and therefore the work pieces are not sufficiently grounded! These sparks can cause severe radio frequency interference (electro-magnetic compatibility = EMC). 6.6.1 GROUNDING THE POWDER COATING SYSTEM 3 4 1 5 2 6 P_01120 7 1 Only use mains cables with grounding strand! 2 Connect grounding cable with booth and system ground! 3 Connect grounding cable to an uncoated metal part of the booth! 4 All paint must be removed from hook and other hanger parts! 5 Wear electrostatically conductive gloves! 6 Wear electrostatically conductive footwear! 7 The floor must be electrostatically conductive! 26

7 OPERATION 7.1 QUALIFICATION OF THE OPERATING STAFF WARNING Incorrect operation! Risk of injury and damage to the equipment. The operating staff must be qualified to operate the entire system. Before work commences, the operating staff must receive appropriate training. The operating staff must be familiar with the provisions of European standards DIN EN 50050-2 and DIN EN 50177. 7.2 SAFETY INSTRUCTIONS WARNING Incorrect operation! Risk of injury and damage to the equipment. If contact with powder materials or cleaning agents causes skin irritation, appropriate precautionary measures must be taken, e.g. wearing protective clothing. The footwear worn by operating staff must comply with EN ISO 20344. The measured insulation resistance must not exceed 100 MΩ (megaohms). The protective clothing, including gloves, must comply with EN ISO 1149-5. The measured insulation resistance must not exceed 100 MΩ (megaohms). 27

7.3 OPTIMIZING THE POWDER CLOUD FOR COATING Procedure: 1. Switch on the high-voltage generation and the powder feed. Note: To minimize wear on the wearing parts, the total air volume should be below 5 Nm³/h! The atomizing air should be adjusted for the flat spray nozzle to 0.1 Nm³/h round spray nozzle to > 0.2 Nm³/h 2. Adjust the powder quantity and the powder speed on a test piece. 7.3.1 RECOMMENDED SETTINGS FOR TOTAL AIR VOLUME Hose diameter Hose length 9 mm 10 mm 11 mm 12 mm 4-8 m 2.0-2.5 m³/h 3.0-3.5 m³/h 4.0-4.5 m³/h 8-12 m 2.5-3.0 m³/h 3.5-4.0 m³/h 4.5-5.0 m³/h 12-16 m 3.0-3.5 m³/h 4.0-4.5 m³/h 5.0-5.5 m³/h 28

7.4 SWITCHING OFF THE SPRAY GUN By releasing the trigger the powder supply is stopped and the high-voltage switched off. To safely switch off the spray gun, e.g. for maintenance work, the control unit must be switched off. 29

7.5 ADJUSTMENT OF POWDER QUANTITY Note: This function can only be activated in combination with the EPG-Sprint X control unit. By pressing the buttons +/- the preset program values of the feed air (powder quantity) can be changed in the desired direction. In this case the total air remains unchanged, the feed and dosage air is readjust accordingly. LED display green Reduce powder quantity Increase powder quantity P_01669 LED display Flashing Constant blinking Permanent lighting Control mode Normal operation of gun Activated recipe has been changed using the "+" or "-" button. By selecting another recipe the modified values of the powder quantity are not taken over, however, the current values of the other recipe are taken over and the blinking changes to flashing. By saving these settings the current values of the powder feed are taken over in the current recipe. The blinking changes back to flashing. By activating the "double click" function the blinking is switched off as well, the preset program values are then active again. Trigger has been actuated with "double click", i.e. the "double click" program is activated 30

7.6 "DOUBLE CLICK" RECIPE (HIGH DYNAMIC REMOTE) This function is used to change quickly to another recipe during a coating operation. The operator can access a previously set recipe by double-clicking on the trigger lever on the spray gun, for example to recoat parts using different parameters (high-voltage, current limiting, air volumes etc.) To access the function, press the trigger lever on the spray gun twice in quick succession and hold down. Upon releasing the trigger, the original recipe will be returned to. Tri Cor 100 5 120 2x 2x 80 4 80 60 3 40 40 2 20 20 1 10 kv µa Tri Cor 100 5 120 2x 2x 80 60 40 4 3 2 80 40 20 2x 20 1 10 kv µa Tri Cor 100 5 120 2x 2x 80 4 80 60 3 40 40 2 20 20 1 10 kv µa P_01701 31

7.7 REPRODUCIBLE SETTING OF THE NOZZLE POSITION P_01671 An adjustment tool is provided for the flat spray nozzle. This allows all flat spray nozzles to be turned without damaging the electrodes and without removing the cap nut. The cap nut only has to be slackened. 32

8 CLEANING AND MAINTENANCE 8.1 CLEANING 8.1.1 CLEANING STAFF Cleaning work should be undertaken regularly and carefully by qualified and trained staff. The staff must be familiar with the DIN EN 50050-2 and DIN EN 50177 provisions. They should be informed of specific hazards during their training. The following hazards may arise during cleaning work: Health hazard from inhaling powder paint Use of unsuitable cleaning tools and aids 8.1.2 SAFETY INSTRUCTIONS DANGER Explosive powder/air mixes! Danger to life and equipment damage. Before starting cleaning or any other manual work, the high-voltage must be shut down and locked to prevent it from being switched back on! The spray gun must be separated from the high-voltage supply before any cleaning work is started! Use only electrically conductive containers for cleaning liquids! Ground the containers! Preference should be given to non-flammable cleaning fluids. Flammable cleaning fluids may only be used if, once the high-voltage has been switched off and all parts carrying high-voltage are discharged to a discharge energy of less than 0,24 mj before they can be accessed. Most flammable solvents have a firing power of around 24 mj or 60 nc. The cleaning agent's flash point must be at least 15 K above the ambient temperature. Only mobile industrial vacuum cleaners of construction type 1 (see EN 60335-2) may be used to remove dust deposits. 33

WARNING Incorrect maintenance! Risk of injury and damage to the equipment. If contact with powder materials or cleaning agents causes skin irritation, appropriate precautionary measures must be taken, e.g. wearing protective clothing. The footwear worn by operating staff must comply with EN ISO 20344. The measured insulation resistance must not exceed 100 MΩ (megaohms). The protective clothing, including gloves, must comply with EN ISO 1149-5. The measured insulation resistance must not exceed 100 MΩ (megaohms). 8.1.3 CLEANING PROCEDURES The cleaning intervals should be adapted by the operator depending on the level of use and if necessary the level of soiling. In doubt, we recommend to contact J. Wagner AG's specialist personnel. The valid health and safety specifications and the safety instructions provided in chapter 4 must be adhered to for all cleaning work. 34

8.2 MAINTENANCE 8.2.1 MAINTENANCE STAFF Maintenance work should be undertaken regularly and carefully by qualified and trained staff. They should be informed of specific hazards during their training. The following hazards may arise during maintenance work: Health hazard from inhaling powder paint Use of unsuitable tools and aids Once the maintenance work is complete, the device must be checked by a qualified person to ensure its safe condition. 8.2.2 SAFETY INSTRUCTIONS DANGER Incorrect maintenance/repair! Danger to life and equipment damage. Corrective maintenance, repair or replacement of devices or parts of devices may only be performed outside the hazard area by specialized personnel. DANGER Incorrect maintenance/repair! Risk of injury and damage to the equipment. Have repairs and part replacements be carried out by specially trained staff or a WAGNER service center. Before all work on the unit and in the event of work interruptions: - Switch off the energy/compressed air supply. - Decompress spray gun and device pressure. - Secure the spray gun against actuation. Observe the operating and service instructions when carrying out all work. 35

WARNING Incorrect maintenance! Risk of injury and damage to the equipment. If contact with powder materials or cleaning agents causes skin irritation, appropriate precautionary measures must be taken, e.g. wearing protective clothing. The footwear worn by operating staff must comply with EN ISO 20344. The measured insulation resistance must not exceed 100 MΩ (megaohms). The protective clothing, including gloves, must comply with EN ISO 1149-5. The measured insulation resistance must not exceed 100 MΩ (megaohms). 8.2.3 MAINTENANCE PROCEDURES The maintenance intervals should be adapted by the operator depending on the level of use and if necessary the level of soiling. In doubt, we recommend to contact J. Wagner AG's specialist personnel. The valid health and safety specifications and safety instructions provided in chapter 4 must be adhered to for all maintenance work. Maintenance work Blow out gun and check for sintering Check gun settings Check gun discharge pressure Blow out powder hoses Check grounding Check compressed air quality Check gun voltage Check powder hoses for bends and sintering Point in time per shift weekly x x x x x x x x 36

8.2.4 REPLACING THE SPRAY GUN Before replacing the spray gun any powder residue must be thoroughly removed. The wear parts in the spray gun, marked in the spare parts list with " checked and, if necessary replaced. ", must be regularly 5 1 4 3 2 P_01672 Procedure: 1. Switch off control unit. 2. Disconnect electrical cable 1 from control unit 2. 3. Disconnect the hoses for powder feed 3 and atomizing air 4 from the spray gun 5. 4. Connect the hoses for powder feed 3 and atomizing air 4 to the new spray gun 5. 5. Connect electrical cable 1 to control unit 2. 6. Switch on control unit. 7. The spray gun is ready for use again. 37

8.3 REMOVING THE FLAT SPRAY NOZZLE Procedure: 1. 1. Unscrew cap nut from the gun housing. 2. Take cap nut with nozzle system off gun body. The nozzle system remains inserted in the cap nut. 2. Note: If the nozzle system doesn't remain inserted in the cap nut, the nozzle system and cap nut must be replaced. 3. P_01673 3. The parts can be separated by gently pressing the sliding ring on the flat spray nozzle. 4. Remove powder residue from the parts removed and from the spray gun. Note: Never place the spray gun or parts of the spray gun in cleaning agent. As a rule the protective wedge needs to be checked for wear and replaced if necessary. 38

8.4 FITTING THE FLAT SPRAY NOZZLE Procedure: 2. Note: 1. Before inserting the electrode holder, the spring contact of the gun body and contact surface of the electrode holder should be checked. The spring contact must be clean and smooth-running, the gun body must also be clean and free of powder deposits. 2. Insert electrode holder into gun housing. 3. 3. Attach flat spray nozzle to electrode holder and attach cap nut. 4. P_01674 4. Screw cap nut onto gun housing until flat spray nozzle can no longer be turned by hand. 39

8.5 REMOVING THE ROUND SPRAY NOZZLE Procedure: 2. 1. 1. Pull off deflector cone. 2. Unscrew cap nut from the gun housing. 3. Take cap nut with nozzle system off gun body. The nozzle system remains inserted in the cap nut. Note: If the nozzle system doesn't remain inserted in the cap nut, the nozzle system and cap nut must be replaced. 3. P_01677 4. Press nozzle system out of cap nut by gently pressing on deflector cone sleeve. 5. Remove powder residue from the parts removed and from the spray gun. Note: Never place the spray gun or parts of the spray gun in cleaning agent. 4. As a rule the protective wedge needs to be checked for wear and replaced if necessary. 40

8.6 FITTING THE ROUND SPRAY NOZZLE 2. 4. 3. 5. Procedure: Note: 1. Before inserting the electrode holder, the spring contact of the gun body and contact surface of the electrode holder should be checked. The spring contact must be clean and smoothrunning, the gun body must also be clean and free of powder deposits. 2. Attach deflector cone sleeve onto electrode holder. 3. Insert electrode holder into gun housing. 4. Slide cap nut onto gun housing. 5. Screw cap nut onto gun housing (hand-tight). 6. Slide deflector cone over deflector cone sleeve. 6. P_01678 41

8.7 REPLACING THE PROTECTIVE WEDGE Note: A wedge tool is available to prevent the protective wedge from being damaged when dismantling and inserting. The wedge tool has a removal side (E) and an attachment side (A). Use the right side for the corresponding procedure! You will find the necessary wearing parts and spare parts in chapter 13 "Spare Parts" of this operating manual. E 1 A 1 Wedge tool 2 Electrode holder (shown with a cut-away view to improve comprehension) 3 Protective wedge (when positioned) 3 2 Procedure: 1. Guide wedge tool 1 into electrode holder 2 up to stop. 1. 2. Pull protective wedge 3 out of electrode holder 2 using wedge tool 1. 2. 3. Press manually without a tool the protective wedge 3 sideways out of wedge tool 1. P_01675 3. 42

Note: The same wedge tool is used to insert the protective wedge. Procedure: 1. 2. Y X P_01676 1. Guide protective wedge 2 into wedge tool 1. 2. Insert both parts into opening on electrode holder until they stop. If it is not possible to push the wedge tool in as far as the mark X, rotate the wedge tool a little until it can be pushed up to the mark. The mark X must be flush with the end Y of the electrode holder. 3. The protective wedge is now correctly assembled and the wedge tool can be retracted out of the electrode holder. 4. The protective wedge remains inserted in the electrode holder. Prior to re-fitting, check whether the contact points on electrode holder 3 and in gun housing 5 have been thoroughly cleaned so that the electrode tip is electrically connected to the high-voltage generator. 5. Fit flat or round spray nozzle with the corresponding electrode holder. 3. 43

8.8 CHANGING FROM FLAT SPRAY NOZZLE TO ROUND SPRAY NOZZLE The standard Corona spray gun is delivered with a flat spray nozzle. The nozzle can be changed easily, as described below. The X1 R electrode holder is necessary to perform the change. CAUTION Electrode tip! Risk of injury. Take care when fitting the X1 R electrode holder. Procedure: 1. 1. Unscrew cap nut from the gun housing. 2. Take cap nut with nozzle system off gun body. The nozzle system remains inserted in the cap nut. Note: If the nozzle system doesn't remain inserted in the cap nut, the nozzle system and cap nut must be replaced. 2. 3. 3. The parts can be separated by gently pressing the sliding ring on the flat spray nozzle. 4. Attach deflector cone sleeve to X1 R electrode holder. 4. P_01679 44

7. 6. 8. Procedure: 5. Before inserting the electrode holder, the spring contact of the gun body and contact surface of the electrode holder should be checked. The spring contact must be clean and smooth-running, the gun body must also be clean and free of powder deposits. 6. Insert electrode holder into gun housing. 7. Slide cap nut onto gun housing. 8. Screw cap nut onto gun housing (hand-tight). 9. Slide deflector cone over deflector cone sleeve. 9. P_01690 45

8.9 MOUNTING THE CORONA-STAR The Corona-Star is a retrofit set for the spray gun, which helps to achieve a better surface quality (e.g. reduction of "orange peel"). WARNING Danger from electric current! Risk of injury and damage to the equipment. Only trained personnel may modify the Corona-Star. Prior to mounting the Corona-Star, the high-voltage and powder feed must be switched off and secured against being inadvertently switched on. 1 2 B Procedure: 1. Guide plug-in contact 1 of Corona-Star into hole B on hook. 2. Attach clip 2 of Corona-Star to housing. Flexible positioning in a range of ± 90 is possible. ±90 P_01703 46

8.10 REPLACING THE SUSPENSION HOOK Procedure: 1. 1. Loosen retaining bolts on rear of hook and unscrew. 2. Slide hook in direction indicated by arrow and remove from gun housing. 2. 3. 3. Fit new hook on receiver and slide in direction indicated by arrow. 4. Fit retaining bolts and tighten. 4. P_01717 47

9 INSPECTIONS IN ACCORDANCE WITH DIN EN 50177: 2010 If the system is used for electrostatic coating with flammable coating powders, testing should be undertaken in accordance with DIN EN 50177: 2010-04 as per Table 3 and Table 4. 48

9.1 OVERVIEW OF INSPECTIONS Section Type of inspection Requirements Inspection by 1 Effectiveness of technical ventilation check 2 Interlock between technical ventilation and high-voltage, compressed air and coating material supply Effectiveness of technical ventilation check The technical ventilation should be interlocked such that the highvoltage cannot be switched on while the technical ventilation is not working effectively. Type of inspection Inspection interval UP/BP ME Measurements of air flow speed / air quantities Check the differential pressure indicator. BP FU Test whether the system is safely stopped and the material supply, supply air and high-voltage are switched off when the ventilation is shut down. Continuously Annually 3 Effectiveness of grounding measures Key: HE = Manufacturer AG = Employer BP = Capable person BSB = Fire safety engineer EFK = Electrician UP = Trained person All the system's conductive elements, such as floors, walls, ceilings, protective grating, transport equipment, work pieces, powder containers, machines or construction parts etc. in the spray area, with the exception of parts which carry high-voltage during operation, must be connected to the grounding system. Parts of the booth must be grounded in accordance with EN 12215. FU = Function inspection ME = Measurement OP = Standard inspection SI = Visual inspection SÜ = Continuous inspection TP = Technical inspection BP SI/ME/SÜ Visual check of ground connections, perform function test on grounding switch, measurement of grounding resistors. Weekly 49

Section Type of inspection Requirements Inspection by 4 Measures to take if conductive components are insufficiently grounded 5 Resistance to ground of work piece's locating point Key: HE = Manufacturer AG = Employer BP = Capable person BSB = Fire safety engineer EFK = Electrician UP = Trained person If sufficient grounding of conductive parts cannot be ensured, their discharge energy must not exceed the permissible value. The resistance to ground of every work piece's locating point must not exceed 1 megaohm (measurement voltage must be 1000 V). The design of the work piece receiver must ensure that the adapters remain grounded during coating. FU = Function inspection ME = Measurement OP = Standard inspection SI = Visual inspection SÜ = Continuous inspection TP = Technical inspection Type of inspection Inspection interval BP ME/SÜ Measurement of discharge energy. BP ME/SÜ Measure resistance to ground (work piece receiver - ground potential) max. 1 MOhm @ 1000 V. Weekly Weekly 50

Section Type of inspection Requirements Inspection by 6 Measures to take if the work pieces are insufficiently grounded 7 Effectiveness of the manually or automatically actuated fire extinguishing systems (room protection system) Key: HE = Manufacturer AG = Employer BP = Capable person BSB = Fire safety engineer EFK = Electrician UP = Trained person If sufficient work piece grounding in accordance with section 6 cannot be ensured, appropriate equipment, e.g. ionizers, may be used to discharge electric charges on the work piece. Such equipment must not exceed the permitted discharge energy of the spray systems with which it is used. In terms of permitted discharge energy, this equipment must be put through the same inspections as the powder spray systems used with it. The discharge equipment must be interlocked with the spray system such that the high-voltage is switched off and that coating cannot take place if the discharge equipment malfunctions. Effectiveness of the manually or automatically actuated fire extinguishing systems (room protection system). FU = Function inspection ME = Measurement OP = Standard inspection SI = Visual inspection SÜ = Continuous inspection TP = Technical inspection Type of inspection Inspection interval BP ME/FU/SÜ Measurement of discharge energy, check the monitoring equipment's test function by triggering it. HE/BSB FU Trigger fire extinguishing system, observe manufacturer's requirements Weekly 6 months 51

10 DISASSEMBLY AND DISPOSAL 10.1 DISASSEMBLY Procedure: WARNING Incorrect disassembly! Risk of injury and damage to the equipment. Before starting disassembly: - Switch off the energy/compressed air supply. - Ensure that all system components are grounded. - Secure system against being switched back on without authorization. Observe the operating manual when carrying out all work. 1. Switch off the system. 2. Lock the supply of compressed air and decompress system. 3. Disconnect the gun connection cable from control unit. 4. Disconnect the powder feed hose to the spray gun and to the powder injector. 5. Disconnect the atomizing air hose to the spray gun and to the control unit. 10.2 DISPOSAL NOTICE Do not dispose of waste electrical equipment with household refuse! In accordance with European Directive 2002/96/EC on the disposal of waste electrical equipment and its implementation in national law, this product may not be disposed of with the household refuse, but must be recycled in an environmentally correct manner. Wagner or one of our dealers will take back your used Wagner waste electrical or electronic equipment and will dispose of it for you in an environmentally friendly way. Please contact one of our service points, one of our representatives or us directly to this purpose. 52

11 TROUBLESHOOTING AND RECTIFICATION DANGER Incorrect maintenance/repair! Risk of injury and damage to the equipment. Have repairs and part replacements be carried out by specially trained staff or a WAGNER service center. Before all work on the unit and in the event of work interruptions: - Switch off the energy/compressed air supply. - Decompress spray gun and device pressure. - Secure the spray gun against actuation. Observe the operating and service instructions when carrying out all work. DANGER Incorrect maintenance/repair! Danger to life and equipment damage. Wagner devices, protective systems and safety, monitoring and control equipment may only be repaired as defined in Directive 94/9/EC (ATEX) by trained Wagner service personnel or capable persons in accordance with TRBS 1203! Note national regulations! Corrective maintenance, repair or replacement of devices or parts of devices may only be performed outside the hazard area! 53

Malfunction Cause Remedy No electrostatics (e.g. no wrap Fault in the high-voltage Contact Wagner Service center. around or powder adhesion) generator. Electrical cable from spray gun Contact Wagner Service center. to control unit faulty. Cascade in spray gun faulty. Contact Wagner Service center. Poor powder wrap around Back-spray Insufficient or no grounding. See chapter 6.4 "Grounding". Powder outlet uneven or inadequate Contamination. Powder sintering. Feed device contaminated. Feed air / dosage air ratio incorrect. Wear on powder injector nozzle. Blow through parts carrying powder. Clean parts carrying powder. See operating instructions for the related devices connected. Adjust at control module resp. control unit. Replace¹) worn parts on powder injector. Spray pattern is uneven Parts of nozzle system worn. Replace worn parts. Cracks in the gun housing Improper handling of the Gun housing must be replaced. powder spray gun. Contact Wagner Service center. 1.) You will find the wear parts and spare parts in the operating manual for the powder injector. 54

12 ACCESSORIES 12.1 FLAT SPRAY NOZZLE Order No. Designation 2321976 X1 flat spray nozzle, complete P_01664 12.2 DEFLECTOR CONE Order No. Designation 2321981 D18 deflector cone, complete P_01665 2321980 D25 deflector cone, complete P_01666 2321171 D34 deflector cone, complete P_01667 12.3 ELECTRODE HOLDER Order No. Designation P_01691 2322529 X1 F ET electrode holder P_01692 2322490 X1 R ET electrode holder 55

12.4 HOSE TAKE-UP Order no. Designation P_01693 2322761 D10-D12 hose take-up, complete P_01694 2322768 D8-D10 hose take-up, complete 12.5 RETROFIT SET CORONA-STAR P_01695 Pos Order No. Designation 2322868 Corona-Star, complete 1 2322835 Corona-Star electrode, complete 1 12.6 WEDGE TOOL 20x P_01696 Pos K Stk Order No. Designation 1 2324124 X1 wedge tool + 20 protective wedges available as accessory, not included in the purchased parts package 56

12.7 NOZZLE EXTENSION X1 VL 150/300 P_01697 Pos K Stk Order No. Designation 1 2323366 X1 VL 150 nozzle extension (150 mm; 5.91 inches) 1 2323356 X1 VL 300 nozzle extension (300 mm; 11.81 inches) 1 2324148 Round spray nozzle X1 VL ET available as accessory, not included in the purchased parts package 12.8 POWDER HOSE Order No. Designation 351794 Powder hose 9 mm 2310699 Powder hose 10 mm 2307502 Powder hose 11 mm 2310700 Powder hose 12 mm 57

12.9 WALL MOUNT P_01861 Order No. Designation 2330223 Wall mount with bracket 58

12.10 POWDER MEASURING ADAPTER DANGER Risk of explosion due to electrostatic charging! Danger to life and equipment damage. Only use powder measurement bag when high-voltage is switched off! for measuring powder quantities for the spray gun Order No. Designation 2325320 X1 powder measuring adapter with bag, complete P_01716 The powder measuring adapter is slid onto the nozzle. 59

13 SPARE PARTS 13.1 HOW TO ORDER SPARE PARTS? To ensure proper spare parts delivery, the following information is necessary: Order number, designation and quantity The quantity does not have to be identical to the numbers in the "Stk" columns of the lists. This number merely indicates how many of the respective parts are used in each module. The following information is also required to ensure smooth processing of your order: - Address for invoice - Address for delivery - Name of the person to be contacted in the event of any queries - Type of delivery (normal mail, express delivery, or courier, etc.) Identification in spare parts lists Explanation of column "K" (labeling) in the following spare parts lists. = Wearing parts Note: No liability is assumed for wear parts = Not part of standard equipment, available, however, as additional extra. WARNING Incorrect maintenance/repair! Risk of injury and damage to the device. Have repairs and part replacements be carried out by specially trained staff or a WAGNER service center. Before all work on the unit and in the event of work interruptions: - Switch off the energy/compressed air supply. - Ensure that all system components are grounded. - Secure the unit against being switched back on without authorization. Observe the operating and service instructions when carrying out all work. 60