INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

Specification Grade Contemporary Wall Mount/Technical Installation Data

Captivate Illuminated Mirror Light

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

Universal Retrofit System Installation Instructions Revised:

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

MAXLITE RKT LED Retrofit Kit

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

ELV1abbccd-e. Color Temperature: 30 = 3000K White 35 = 3500K White 40 = 4000K White 45 = 4500K White 50 = 5000K White

INSTALLATION GUIDE Works in double and single ended wiring.

MOONRING 1.5 MOONRING 3

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

LED 2/3/4ft T8 Tube 120V


INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Installation Guide. WARNINGS Read all instructions and warnings before attempting installation

Product Installation Instruction LED Tube Lamp Retrofit Kits

Tetra minimax. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTION Bollard Light 12V

Installation Instructions BLTR and 2BLTR Relight Assembly

TECTONIC LED CORP. ISO

LED Recessed Troffer Retrofit Kit

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

LAL SERIES LED LUMINAIRE

IMMERSION. imagination at work. Retrofit Installation Guide. GE Lighting. LED Refrigerated Display Lighting

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION

Wet Rated Batten LED Luminaire

960 Montage sur staff préfabriqué Mounting in prefabricated plaster

Lumination TM LED Luminaires LAL Series - Continuous Run Option

GETTING STARTED WITH IN-WALL DIMMER SWITCH

INSTALLATION INSTRUCTIONS

I. Pendant Mount Installation

UB-2 2 Universal Button

Cable Cubby 1202 and 1402 Installation Guide

WARNING / AVERTISSEMENT

WARNING/AVERTISSEMENT. Coupez l alimentation électrique à la boîte de fusibles ou au disjoncteur avant servicing or installing product.

INSTALLATION GUIDE FOR VM-3000 SERIES INTEGRATED VOICE EVACUATION SYSTEM

Installation Instructions

Instruction/Installation Manual

Lumination TM LED Luminaires Suspended LED Fixture (Series EP14)

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

VR44-MU-xxx-8yy-xxxxA

OPTIMAX RADIANT FIELD RETROFIT INSTRUCTIONS

Spun Bay Installation Standard Version (non dimmable), Hook Mount

SAVE THESE INSTRUCTIONS

IMMERSION. imagination at work. LED Refrigerated Display Lighting. Vertical Cases RV40 Series LED Drivers GEPS4000NCMUL-SY

INSTALLATION INSTRUCTIONS ModuSys LED Retrofit Kit 2x2, rev. D.02

IMMERSION. GE Lighting. OEM Installation Guide. imagination at work. LED Display Lighting

MEDMASTER DOWNLIGHT Luminaires for MRI Applications

VR44-MU-xxx-8yy-xxxxA

MEDMASTER CLEANSCENE MRI/Imaging Suite Luminaires

OmniAire Omnitec Design, Manufacturing Air Purification Equipment Since 1988

Cable Cubby 650 UT Installation Guide

A1100 GUARDIAN OVERFILL PREVENTION VALVE (with Installation Kit)

VR22-MU-xxx-8yy-xxxxA

IMPORTANT SAFETY INSTRUCTIONS

MEDMASTER EXTERNAL POWER SUPPLY

IMPORTANT: SAFETY INSTRUCTIONS Important: Instructions de securité

STOP BEFORE YOU BEGIN READ THESE INSTRUCTIONS COMPLETELY AND CAREFULLY

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

VersaWall SlimLine 1750

Installation Instructions

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Optimax Pro Retrofit Instructions

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Installation Instructions

Have a bright day! Nicholas Harmon President, Verilux, Inc.

HBC-20 - LED HIGH BAY

A1100 GUARDIAN OVERFILL PREVENTION SYSTEM

Index. Primary components - back sections Composantes principales - traverses ou meneaux

UL AND CODE COMPLIANCE

Installation Instructions

INSTALLATION INSTRUCTIONS

RSA-MRZ Installation Instructions

LED IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTION Bliss - Vanities & Wall Sconces WS-79622

Installation Instructions

QTM-eLED INSTALLATION INSTRUCTIONS Must be installed by licensed electrician.

Installation Instructions

UNPACKING THE UNIT. Alcohol cleaning pad

INSTALLATION INSTRUCTIONS 120V DirectAC LED Engine Kit

RSA-MRZ Installation Instructions

Transcription:

INDIGO-CLEAN TECHNOLOGY RETROFIT KIT INSTALLATION INSTRUCTIONS 1 IMPORTANT SAFETY INFORMATION Risk of shock. Disconnect power before installation. DANGER- RISQUE DE CHOC- COUPER L ALIMENTATION AVANT L INSTALLATION WARNING Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. If not qualified, do not attempt installation. Product must be installed in accordance with NEC or your local electrical code. If you are not familiar with these codes and requirements, contact a qualified electrician. Risque d incendie ou de choc électrique. L installation du kit upgrade LED exige Ia connaissance des systèmes électriques pour luminaires. Si non qualifié, ne tentez pas d installation. Ce produit doit être installé conformément à NEC ou votre code électrique local. Si vous n êtes pas familier avec ces codes et ces exigences, veuillez contacter un électricien qualifié. WARNING Risk of fire or electric shock. To prevent wiring damage or abrasion, do not expose wires to the edge of sheet metal or any other sharp objects. Pour éviter les dégâts de câblage par l abrasion, ne pas mettre en contact les fils électriques avec des bords de tôle ou d autres objets pointus. WARNING Risk of fire or electric shock. Check the existing wiring for damage before Installing upgrade kit. Do not install if existing wires are damaged. Risque d incendie ou de choc électrique. Vérifier si le câblage existant n est pas endommagé avant l installation du kit upgrade LED. Ne pas installer si des fils sont endommagés. WARNING Risk of fire or electric shock. Luminaire wiring and electrical parts may be damaged when drilling for installation of the LED upgrade kit. Check for enclosed wiring and components. Risque d incendie ou de choc électrique. Câblage électriques peuvent être endommagés Iors du perçage pour l installation du kit upgrade LED. Vérifier les fils et composants. NOT FOR USE WITH PHASE CUT DIMMERS. NE PAS UTILISER AVEC GRADATEUR À COUPURE DE PHASE. WARNING Risk of fire or electric shock. Install this kit only in luminaires that have the construction features and dimensions shown in the photographs and/ or drawings, and where the input rating of the retrofit kit does not exceed the input rating of the luminaire. ATTENTION- Risque d incendie ou de choc électrique. lnstallez ce kit seulement dans les luminaires qui ont les caractéristiques de construction et les dimensions dans les photographies ou les dessins de Ia page suivante. Only the holes indicated in the photographs or drawings may be made or altered as a result of the kit installation. Do not leave any other holes open in a wiring enclosure or electrical component. Seulement les trous indiqués dans les photographies ou les dessins peuvent être faits ou altérés pour l installation du kit upgrade LED. Ne laissez aucun trou ouvert dans le compartiment électrique. THE RETROFIT KIT IS ACCEPTED AS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY CSA OR AUTHORITIES HAVING JURISDICTION. PRODUCT MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH THE APPLICABLE ELECTRICAL CODES. THE INSTALLATION GUIDE DOES NOT SUPERSEDE LOCAL OR NATIONAL REGULATIONS FOR ELECTRICAL INSTALLATIONS. LE NÉCESSAIRE DE MODERNISATION EST ACCEPTÉ À TITRE DE COMPOSANT D UN LUMINAIRE LORSQUE LA PERTINENCE DE LA COMBINAISON DOIT ËTRE DÉTERMINÉE PAR LA CSA OU PAR LES AUTORITÉS COMPÉTENTES. CE PRODUIT DOIT ETRE MIS EN PLACE PAR UN ELECTRICIEN QUALIFE CONFORMEMENT AUX CODES ELECTRIQUES APPROPRIES APPLICABLES. LE GUIDE D INSTALLATION NE SUPPLANTE PAS LES REGLEMENTS LOCAUX OU NATIONAUX EN MATIERE D INSTALLATIONS ELECTRIQUES.

2 MINIMUM DIMENSIONS For installation in a 2 x2 or 2 x4 surface or recessed luminaire, the following minimum dimensions apply: 2.5 deep pan 3 wide minimum wiring compartment 43 minimum length to accommodate 4 light bars; 22 minimum length to accommodate 2 light bars For installation into linear troffers, wraparound, striplights, or vaportights the following minimum dimensions apply: Minimum wiring compartment depth: 2.5 Minimum 3.25 wide flat surface compartment cover width 43 minimum length to accommodate 4 light bars Only one kit is to be installed per luminaire SUPPLIED COMPONENTS (2) or (4) Lensed Modules/Light Bars (1) Driver (1) Black and White Driver Input Extension Wires (1) or (3) Red and Blue Driver Output Extension Wires (2) Driver Screws (Serrated Washer) (6) or (2) Connectors (Orange 3-Position or Yellow 4-Position) (2) Connectors (Red, 2-Position) (1) Relamp Label (2) Screws supplied per 2 Light Bar, (3) Screws supplied per 4 Light Bar SUITABLE LUMINAIRE TYPES 2' 4-Lamp System RK-ICT-24-55C43K-DCC-DV 2x2 Troffers: Lensed, Type IC (Insulated Ceiling) or Type Non-IC, 25 C max ambient, requires minimum 3 depth, one RK-ICT-24-55C43K-DCC-DV per troffer 4' 2-Lamp System RK-ICT-48-55C43K-DCC-DV 1x4 or 2x4 Troffers: Lensed, Type IC (Insulated Ceiling) or Type Non-IC, 25 C max ambient, requires minimum 3 depth, one RK-ICT-48 per troffer 4ft Wraparound: Lensed, (minimum 8.5 width and 2.25 depth), 25 C max ambient, requires 3 wide minimum wiring compartment, one RK-ICT-48 per 4ft, 4ft Striplight: Non-lensed, (minimum wiring compartment dimensions 2.5 depth and 4 width), 25 C max ambient, one RK-ICT-48-55C43K-DCC-DV per 4ft 4ft Vaportight: Lensed, minimum 5 depth and 6.75 width, 25 C max ambient, one RK-ICT-48 per 4ft vaportight. FRENCH TRANSLATION 2' 4-Lamp System RK-ICT-24-55C43K-DCC-DV 2x2 à lentille, Type IC ou de Type NON-IC, température ambiante max. de 40 C, profondeur min. de 2.5 RK-ICT-24-55C43K-DCC-DV 4' 2-Lamp System RK-ICT-48-55C43K-DCC-DV 1x4 ou 2x4 à lentille, Type IC ou de Type NON-IC, température ambiante max. de 25 C, profondeur min. de 3 4 pi., à lentille enveloppante (largeur min. de 8.5 et profondeur de 2.25 ), compartiment de câblage de 3 de large min., température ambiante max. de 25 C 4 pi, sans lentille, réglette, (dimensions du compartiment de câblage min., 2.5 de profond, 4 de large), température ambiante max. de 25 C Lentille 4 pi. étanche à la vapeur avec profondeur min. de 5 et largeur de 6.75, température ambiante max. de 25 C Montage continu sur 2 rangées, Type IC ou Type Non-IC, chemin lumineux encastré de 1 x 4 conçu pour des températures ambiantes maximum de 25 avec compartiment de lampe de 4 pi. x 11-3/4 x 4-1/4 et compartiment de câblage de 4 pi. x 3 x 1-1/2.

3 FIXTURES USING 4' MODULES 1. Disconnect power to the fixture. 2. For 2x2 or 2x4 luminaire installations, locate latches on the lens frame and release. Swing lens frame open and carefully allow lens to hang open as shown in Figure 1. NOTE: For vaportights and lensed wraparound installations, remove lens and set aside. For striplight and non-lensed wraparound installations go to Step 3. 6. Cut the leads from the input power to ballast. See Figure 5. NOTE: Cut leads at the ballast leaving as much length as possible to facilitate installation of the driver. Strip wires as necessary. Fig. 5 Fig. 1 7. Remove ballast by unscrewing from the fixture and dispose of properly per local regulations. See Figure 6. Fig. 6 3. Remove existing linear fluorescent tubes as shown in Figure 2. Dispose of tubes per local regulations. Fig. 2 8. Locate a flat area on the fixture within the wiring compartment to mount the driver. The driver must set flush with the fixture for proper thermal management. Install the driver where possible using existing crow s feet or mounting holes, and the provided two drill point screws with serrated heads. Ensure driver is properly grounded. See Figure 7. 4. Remove wiring compartment to access existing ballast and set aside. See Figure 3. Fig. 3 Fig. 7 5. Cut the leads from the ballast to the socket housing on both ends of the fixture as shown in Figure 4. NOTE: Cut the leads at the socket housing as short as possible. Push the leads back behind the lampholder housing or cap any exposed leads. Lampholders may be removed but require removal of lampholder leads. Fig. 4 9. Peel liner from double-sided foam tape strips at opposite corners of light bar. Position light bar approximately at the centerline of existing lamp sockets and centered between the sockets as shown in Figure 8. Apply pressure to temporarily affix the light bar. Fig. 8

4 10. Once positioned, secure light bar to the fixture with the (6) provided selftapping screws as shown in Figure 9. Repeat for additional light bars. Fig. 12 CAUTION: Foam tape is temporary for ease of installation. Do not complete retrofit installation without securing screws (3 per lamp). To maintain a Damp or Wet environmental rating of the luminaire, fasten all retrofit components to internal surfaces, such as wireways or reflectors. Do not use fasteners on any surface that functions as the environmental enclosure. Fig. 9 14. Prepare input power leads by stripping 1/4. Connect power lead wires to the correct driver contacts as indicated on the driver label. See Figure 13 NOTE: If the existing black and white lead wires are too short to reach the new driver position, an extension can be created using the provided black and white leads and red two-position connector. 11. Recommended mounting pattern. See Figure 10. Fig. 13 12. Connect red leads from both light bars to the loose red lead wire with the supplied orange 3-position connector by pushing into the open slot. Repeat for blue leads. See Figure 11. Fig. 11 Fig. 14 15. Wiring Schematics; See Figure 14 and Illustration 2, Page 7. SUPPLY WIRING SERRATED HEAD SCREW GROUNDS DRIVER TO HOUSING WHITE BLACK LED DRIVER VIOLET OPTIONAL 0-10V GREY DIMMING CONTROL 13. Connect red and blue lead wires to the correct driver contacts as indicated on the driver label. See Figure 12. NOTE: Optional 0-10V Analog Dimming Interface Use Violet (+) and Gray (-) for connection to 0-10VDC. The dimming control connections on the LED driver are for Class 2 wiring methods only. Separate the dimming control field wiring from the branch circuit field wiring in the wiring compartment in accordance with the National Electrical Code. 16. Replace wiring compartment cover. Dress light bar leads under the cover. Take care not to pinch red and blue leads between the cover and fixture. 17. Place relamp label at a visible location in the fixture. Close or replace lens and secure latches or other fastening means. See Figure 15. Fig. 15

5 FIXTURES USING 2' MODULES 1. Disconnect power to the fixture. Locate latches on the Lens frame and release. Swing lens frame open. Lens frame can hang open or be removed. Remove existing fluorescent tubes and discard. Remove wiring compartment cover and set aside. (see Fig. 1) Fig. 1 4. If there are any fluorescent sockets on the opposite end of the fixture, cut these wires where they leave the wireway. Capping these wires is not necessary as these will not be used. Sockets and wires can remain in the wireway. (See Fig. 4) Fig. 4 2. Disconnect ballast from power supply leads. If a connector is present cut the wires at the connector (see Fig. 2) Fig. 2 5. Locate flat areas on the fixture for the four modules. Peel the liner from the double sided foam tape strips at opposite corners of the module. Position modules on flat areas of the fixture. Apply pressure to temporarily affix the module. (see Fig. 5). Route the blue and red module wires under the wireway loosely installed in Step 3. After all 8 wires (4 red, 4 blue) have been routed to the driver compartment, tighten the wireway screw, being careful not to pinch any wires. Permamently fasten the modules using 2 of the provided self drilling and tapping screws per module. To maintain a Damp or Wet environmental rating of the luminaire, fasten all retrofit components to internal surfaces such as wireways or reflectors. Do not use fasteners on any surface that functions as the environmental enclosure. Fig. 5 3. Identify the wire way that contains the blue/red wires from the ballast to the sockets, and remove this wireway. Remove the fluorescent sockets and attached wires. Loosely reinstall the wireway into position. (See Fig. 3) Fig. 3 6. Remove fluorescent ballast and install driver into same location. (See Fig. 6) Fig. 6

6 7. Wiring connections See Wiring Schematics 2ft Version Fig. 8 and Illustration 1, Page 7. Starting with the red driver wire, connect one of the supplied push type wire connectors to this lead, and insert the two supplied wire leads into the remaining holes in the connector. Then connect another wire connector to the other end of the red wire. Insert the 4 red module wires into the remaining 4 holes in the connectors (See Fig. 7). Repeat with the blue wires. Fig. 7 Insert red from 2 modules here (2) Jumper wires to connectors Insert reds from 2 modules here 8. Supply Connections Connect the black and white supply wires to the black and white driver wires using the supplied push connectors. Dress wires in wiring compartment to fit within cover space. Reinstall driver compartment cover. Place relamp label at a visible location within fixture. Close lens door. Fig. 8 Wiring Schematic 2ft Modules SUPPLY WIRING SERRATED HEAD SCREW GROUNDS DRIVER TO HOUSING WHITE BLACK LED DRIVER VIOLET OPTIONAL 0-10V GREY DIMMING CONTROL Single from Driver

7 ILLUSTRATION 1-4' 2 SYSTEM SUPPLY WIRING SERRATED HEAD SCREW GROUNDS DRIVER TO HOUSING WHITE BLACK LED DRIVER VIOLET GREY OPTIONAL 0-10V DIMMING CONTROL ILLUSTRATION 2-2' 4 SYSTEM WHITE BLACK SUPPLY WIRING SERRATED HEAD SCREW GROUNDS DRIVER TO HOUSING LED DRIVER VIOLET GREY OPTIONAL 0-10V DIMMING CONTROL

8 CUSTOMER SERVICE For technical assistance, call 1-800-4KENALL (1-800-453-6255). WARRANTY Kenall reserves the right to issue credit, repair, or replace the defective merchandise, at its discretion, upon notification and confirmation by its local representative of the defect. Kenall also reserves the right to test and examine the defective product if the defect is questionable and to deny the warranty herein for any product altered, improperly installed, installed in applications for which it is not intended. This includes operation in ambient temperatures above stated limits for any length of time. Failure by electrical surge shall not be covered under warranty. Kenall assumes no responsibility for labor or freight costs incurred in connection with the installation, removal, or replacement of products determined to be defective or any other consequential or incidental damages arising from the use of the product. Kenall s entire liability on any claim of loss or damage resulting from a defective product is limited to the replacement price of the product.