Combined ballast Combined ballast XCU 16 XCR 17 XHF 18-19 Batteries 20 15 Combined ballast
XCU The XCU combined units together with the appropriate inverter circuits For Linear and TC-L fluorescent lamps Safety class I 28mm An extensive range Supplied with IDC/push-wire terminals, which are suited to automatic and manual assembly Each zinc galvanised steel XCU unit incorporates a constant current charge circuit with deep discharge protection The low profile unit provides flexible mounting options and is compatible with most louver and diffuser luminaires 42mm 424mm Fixing centres 415mm Battery packs Advanced, high temperature Nickel Cadmium batteries provide a minimum of 4 years service life (when installed in compliance with EN 60598-2-22). Use the Performance and table on page 19 to identify the number of cells required. Select your desired configuration from the detailed battery information on page 20. 16 Combined ballast XCU
XCR The XCR combined units together with the appropriate inverter circuits For compact fluorescent lamps Safety class I TC-DD units Safety class II TC-DEL/TEL 35mm 164mm 93mm Fixing centres 155mm x 80mm An extensive range TC-DEL/TEL units are supplied with push-wire terminals TC-DD units are pre-wired complete with LED indicator and battery connectors Each zinc galvanised steel/polycarbonate housed XCR unit incorporates a constant current charge circuit with deep discharge protection Twin lamp versions can be configured for mains lamp use The low profile unit provides flexible mounting options Available as open Printed Circuit Boards (PCBs) Battery packs Advanced, high temperature Nickel Cadmium batteries provide a minimum of 4 years service life (when installed in compliance with EN 60598-2-22). Use the Performance and table on page 19 to identify the number of cells required. Select your desired configuration from the detailed battery information on page 20. 17 XCR Combined ballast
XHF The XHF combined units and emergency lighting unit and are designed to fit simply within contemporary luminaires For TC-DD fluorescent lamps Safety class I A lamp holder, LED indicator and NiCad battery are incorporated to simplify installation Only unswitched live, switched live, neutral and earth supply connections are required Supplied with screw terminals with cable protectors for mains connections 38mm Fixing centres 147mm 145mm 165mm 18 Combined ballast XHF
Performance and part XCU Battery T5 14 watt 60 0.28 0.98 16 3.6 3 XCU414.3E twin 18 watt 39 0.18 0.98 13 3.6 3 XCU218.3E 18 watt 75 0.35 0.98 13 3.6 3 XCU418.3E single 36 watt 39 0.18 0.98 8 3.6 3 XCU136.3E twin 36 watt 75 0.35 0.98 8 3.6 3 XCU236.3E T8 36 watt 150 0.7 0.98 8 3.6 3 XCU436.3E single 58 watt 60 0.27 0.98 6 4.8 4 XCU158.3F twin 58 watt 115 0.51 0.98 6 4.8 4 XCU258.3F single 70 watt 76 76 0.98 7 6 5 XCU170.3G twin 70 watt 135 0.61 0.98 7 6 5 XCU270.3G TC-L twin 55 watt 115 0.51 0.98 10 7.2 6 XCU255.3H XCR Battery single 16 watt 22 0.10 0.98 13 3.6 3 XCR121.3E single 21 watt 26 0.12 0.98 9 3.6 3 XCR121.3E TC-DD single 28 watt 31 0.15 0.98 5 3.6 3 XCR128.3E single 28 watt 31 0.15 0.98 12 4.8 4 XCR128.3F single 38 watt 41 0.19 0.98 9 4.8 4 XCR138.3F TC-DEL 10 watt 23 (31) 0.10 (0.15) 0.93 (0.98) 19 3.6 3 XCR213.3E TC-DEL/ TC-TEL 13 watt 18 watt 26 watt The results in brackets relate to twin lamp operation 26 (35) 0.12 (0.15) 0.95 (0.98) 18 3.6 3 XCR213.3E 26 (45) 0.12 (0.19) 0.96 (0.98) 15 3.6 3 XCR218.3E 34 (54) 0.14 (0.23) 0.96 (0.98) 10 4.8 4 XCR226.3F XHF Battery* TC-DD * Supplied complete single 16 watt 22 0.10 0.98 13 3.6 XHF21.3E single 21 watt 26 0.12 0.98 9 3.6 XHF21.3E single 28 watt 32 0.14 0.98 12 4.8 XHF28.3F single 38 watt 40 0.18 0.98 9 4.8 XHF38.3F 19 Performance and part Combined ballast