LHW-3P Load Holding Valve Winch

Similar documents
LBM Load Brake Valve Motor

FC2-1L Flow Control Valve, double

Annex to the CG4 Manual: HydraBrain

Modular Unit 6MB HYDRANOR MODULAR UNIT 6MB GENERAL DESCRIPTION. 6MB-200-**-2C General Arrangement. Rev

Pilot Operated Proportional DC Valve Series D*1FW / D*1FT

Steering unit LAGZ. Data sheet. Series 2 x

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN

Steering unit LAGC. Data sheet

Pilot control unit with end position lock for the remote control of directional valves

Sectional Directional Control Valve RSQ 240

Connection blocks type HMP with integrated lifting and lowering function for proportional spool valves type PSL and PSV, size 2 and 3

Proportional Pressure Reducing Valve PDM08130

6/2 ways/positions flow diverters

Flow sharing control block in mono block / sandwich plate design M6-15

LUDV control block in mono block/sandwich plate design M7-20

Proportional pressure reducing valve, pilot operated, with on-board electronics (OBE) and position feedback

6 to14/2 ways/positions bankable flow diverters flangeable

Priority valve LPS. Data sheet. Series 1 x

RA / Internal Gear Pump Model GP3, Series 3X Fixed Displacement. Typical application:

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Leak-Free Load-Control Valve NS 32, Cartridge Design

Flow sharing control block in mono block / sandwich plate design M6-22

Steering unit LAGU. Data sheet

VINCKE HYDRAULIC PUMPS

PISTON MOTORS FOR CLOSED LOOP SYSTEMS types HMF/A/V/R-02

Sectional Directional Control Valve RS 220

Chapter 6: Check Valves

Proportional pressure reducing valve type KFB 01 (hydraulic joystick)

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Hydraulic inch power brake valve LT 31

Pilot-Operated Proportional DC Valve Series D*1FH

Proportional pressure reducing valve, pilot operated

Flow sharing control block in sandwich plate design M7-25

Proportional pressure relief valve, pilot operated

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Variable Vane Pump, Direct Controlled PV7...A Series 1X / 2X

6/2 ways/positions flow diverters

Pressure controlled the 2-way directional valve type CNE

Proportional, solenoid actuated flow control valves type SE and SEH

External Gear Pumps Series F

Load-holding valves type LHDV

6 to14/2 ways/positions bankable flow diverters flangeable

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Pilot-Operated Directional Control Valves Series D3 - D11

VPN2-10/MR. Functional Description HU /2008. Pilot Operated Pressure Relief Valves. Replaces HU /2005

Servo solenoid valves with on-board electronics (OBE)

Proportional pressure relief valve, pilot operated, with on-board electronics (OBE) and position feedback

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

6 to14/2 ways/positions bankable flow diverters flangeable

LUDV control block of sandwich plate design

4/3 Proportional directional valve elements L85P5 with proportional (EDC-IP) hydraulic control and flow sharing control (LUDV concept) PATENT PENDING

P2060 P2075 P2105 P2145 P3105 P3145

Releasable twin check valve type DRH

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Open center control block in mono block design MO-16, 22, 32

Chapter 6: Check Valves

HYDRAULICS VINCKE HYDRAULIC PUMPS

Priority valve Type LPS

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

VSK. Functional Description HA /2008. Constant Flow - Control Valves VSK4 VSK2 VSK2 VSK4. Replaces HA /2000

Pressure reducing valve, pilot operated

2.3 MEDIUM HEAVY DUTY SERIES

Proportional Throttle Valves Series TDL

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Directional servo-valve of 4-way design

HP3V SERIES. Swash-plate Type Axial Piston Variable Displacement Pump

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G

Safety valves direct, pilot operated and cartridge execution

THE PRODUCTION LINE OF PONAR WADOWICE

Available manual, pneumatic, and hydraulic spool control kits.

Proportional pressure relief valve

6/2 ways/positions flow diverters

PUMP SIZE Flow rate at 1500 rpm lt/min Operating pressures bar

Axial piston variable motor A6VM Series 63. Europe. RE-E Edition: Replaces:

Fixed Displacement Pump A4FO Series 10 Axial Piston Unit, Swashplate Design

VQ400M SERIES CLASS A COMBINATION VALVES INSTRUCTION SHEET APPLICATION

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

Servo solenoid valves with on-board electronics (OBE)

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Hydraulically pilot operated cartridge check valves Type RHC and RHCE without and with hydraulic pre-relief

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

3-way servo solenoid valves, cartridge type, pilot operated, with inductive position transducer

Proportional directional control valve, pilot operated with on-board electronics (OBE) and inductive position transducer

Directional Control Valve Series D3W Soft Shift

Proportional Pressure Relief Valve Series RE*T

Axial Piston Fixed Motor A2FM

Central Hydraulics Valve for Tractors with Priority Function for Steering, Trailer Brake and Pilot Oil Valve

2/2 Solenoid Cartridge Valve, Size 10

Chapter 10: Valves for Pipe Mounting

Directional Control Valve Series 4D01 (DENISON)

Dual Axis Hydraulic Joystick Series JH4

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

Axial Piston Variable Double Pump A8VO

Output flow In l/min at 1500 min

Variable displacement axial piston pump type V30D

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

VED*M PROPORTIONAL PILOT OPERATED DIRECTIONAL CONTROL VALVES

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Transcription:

Table of Content 1 General Description... 2 1.1 Applications... 2 1.2 Mounting Location (Recommendation)... 2 1.3 Function... 2 1.4 Characteristics... 2 2 Technical Data... 3 3 Ordering Information... 4 3.1 Type Code... 4 3.2 Currently available Versions... 4 4 Description of Features according to Type Code... 5 4.1 Feature 1: Design... 5 4.2 Feature 2: Connection Ports... 5 4.3 Feature 3: Spool... 5 4.4 Feature 4: Pressure Setting... 5 4.5 Feature 5: Activation... 5 4.6 Feature 6: Damping System... 5 4.7 Feature 7: Opening pressure... 6 4.8 Feature 8: Directional valve for mechanical brake... 6 5 Installation... 7 5.1 General Instructions... 7 5.2 Connection Proposal... 7 5.3 Mounting - Installation Space... 7 5.4 Setting the pressure relief for the attachment... 7 5.5 Feature 7: Adjustment of opening pressure... 8 5.6 Dimensions Size SAE ¾... 8 5.7 Dimensions Size SAE 1¼... 9 6 Notes, Standards and Safety Instructions... 10 6.1 General Instructions... 10 6.2 Standards... 10 6.3 Safety requirements... 10 Subject to Modifications Version: LHW-3P_02E.doc 1/10

1 General Description If loads are to be raised and lowered using hydraulic winch drives, a load holding valve should be installed on the winch motor for safety reasons. Load holding valves are suitable for motor and cylinder applications. They guarantee a leak-free locking of the consumer. The opening is not effected by the load pressure and is controlled by opposing side pressure. This prevents the consumer from getting ahead of the incoming volume flow. The load holding valves are suitable for applications that are subject to vibration, such as e.g. winch drives and are characterized by their high sensitivity and the direct joystick response. Load holding valves of design 3P are equipped with a pressure relief valve, which restricts the maximum pressure on the consumer. Advantages Quick installation Optimal dampening for tough application Adapting the dampening characteristics does not influence the start of opening 1.1 Applications The WESSEL enables low-loss load lifting by a check valve. The valve prevents any fast movement caused by the load as opposed to the incoming oil flow. The load can be retained without any oil leaking and lowering is controlled. 1.2 Mounting Location (Recommendation) The Load holding valve Winch is flanged with port B directly onto the hydraulic winchmotor. 1.3 Function The lifting-line from the winch control valve is connected to port A (lifting ) of the load holding valve. The lowering-line is directly connected to the winch motor. This line is also connected to the port X as a signal line to start the lowering operation.. For lifting the load, the volume flow is directed from port A through a check valve to the winch motor. In the idle position the load is locked leak-free. To lower the load, the valve is opened by the rising pressure in X. The initial opening is adjustable. The lowering of the load is very sensitive and independent of load pressure. Thus prevents driving loads faster than the incoming oil flow permits. The damped activation of the valve ensures a vibration- free operation. The valve is provided with a pressure valve which limits the maximum pressure at the consumer. It is important to note that the specified pressure corresponds to the opening pressure of the pressure valve. Make sure that the return line only has a low back pressure even at higher flow rates. 1.4 Characteristics Oscillation-free load lowering Extremely precise and fine characteristics, especially with lower speeds Leakage free load locking Robust valve construction with redundant spring system ensures the greatest safety Pressure relief function for winch connection Subject to Modifications Version: LHW-3P_02E.doc 2/10

2 Technical Data Criteria Unit Value A, B SAE ¾ SAE 1¼ (DIN ISO 6162-2, SAE J518/2 (CODE62)) Max. operating pressure bar 420 Pressure setting See type code feature 04: Pressure setting Max. volume flow See type code feature 03: Spool Weight kg 6,2 12,2 Connection Connection sizes Maximum Pressure SAE ¾ SAE 1¼ X, MVSt G ¼ ISO 1179-1 350 MA, MB, B-1 M8x1 G ¼ ISO 1179-1 bar 420 T G ¼ ISO 1179-1 < 1 bar Installation position any Hydraulics Hydraulic fluid Mineral oil (HL, HLP) conforming with DIN 51524, other fluids upon request Hydraulic fluid temperature range -20 +80 C Environmental temperature: < +50 C Viscosity range Contamination grade 2,8 500 mm2/s Filtering conforming with NAS 1638, class 9, with minimum retention rate β 10 75 Subject to Modifications Version: LHW-3P_02E.doc 3/10

3 Ordering Information 3.1 Type Code LHW 3P HYP03B 0 00 01 02 03 04 05 06 07 08 00 Product group LHW 01 Design standard 3P 02 Connection(s) motor / cylinder ISO 6162-2 (SAE J518 Code62) metric SAE ¾ SAE 1 ¼ 05C 05G 03 Spool Design of the spool optimized for the specified volume flow. Specifications in l/min SAE ¾ 200 SAE ¾ 250 SAE ¾, SAE 1 ¼ 300 SAE ¾,SAE 1 ¼ 350 SAE 1 ¼ 400 SAE 1 ¼ 500 SAE 1 ¼ 600 04 Pressure setting opening level pressure valve at 10 l/min in bar, 150bar to 420bar XXX 05 Activation Hydraulically proportional HYP03B 06 Damping (orifice selection) minor damping 01 medium damping 02 strong damping 03 07 Opening pressure Pressure at port X, Standard 16 bar = 016 XXX 08 Directional valve for mechanical brake unavailable 0 XXX fixed features XXX customer selectable features available not available Some theoretical configurations might be not feasible for technical reasons. For relating questions please ask for our advice. 3.2 Currently available Versions The versions listed below are available standard-versions. Further versions in the range of the above mentioned features are available on request. Designation Type Code Part Nr LHW-3P SAE3/4 CD62 350LPM 250BAR LHW -3P -05C -350-250 -HYP03B -01-014 -0 536.060.008.9 LHW-3P SAE3/4 CD62 200LPM 420BAR LHW -3P -05C -200-400 -HYP03B -01-014 -0 536.060.016.9 LHW-3P SAE11/4 CD62 500LPM 420BAR LHW -3P -05G -500-420 -HYP03B -01-015 -0 538.060.005.9 LHW-3P SAE3/4 CD62 200LPM 420BAR LHW -3P -05C -200-420 -HYP03B -03-024 -0 536.060.022.9 LHW-3P SAE1 1/4 CD62 300LPM 420BAR LHW -3P -05G -300-420 -HYP03B -03-024 -0 538.060.012.9 LHW-3P SAE1 1/4 CD62 400LPM 150BAR LHW -3P -05G -400-150 -HYP03B -03-017 -0 538.060.022.9 Subject to Modifications Version: LHW-3P_02E.doc 4/10

4 Description of Features according to Type Code 4.1 Feature 1: Design Design of the valve with an additional pressure valve for the protection of the winch motor 4.2 Feature 2: Connection Ports The Load holding valve Winch is flanged with port B directly onto the hydraulic winchmotor. The lowering-line from the main control valve is directly connected the winch motor also to the piloting port X of the load holding valve. 4.3 Feature 3: Spool 4.4 Feature 4: Pressure Setting The pressure limiting valve is used for cutting down the dynamic load on the motor caused by pressure spikes. Make sure to always set that valve sufficiently higher than the maximum operating pressures. Pressure limiting valves have a hysteresis: Be aware that the pressure limiting valve closes at a lower pressure than the adjusted opening point. Otherwise this can lead to an uncontrolled lowering when the pressure relief function is actuated with loads close to the opening point of the valve. 4.5 Feature 5: Activation The valve is only activated externally for lowering operation. Therefore a pressure signal which is divided from the lowering line pilots the load holding valve at port X. For lifting the load the flow is directed from port A via a check valve to the winch with low losses. In idle position the load is locked without any leakage. To lower the load the valve is opened by increasing pressure at port X. 4.6 Feature 6: Damping System Inlet and outlet orifices dampen the opening speed of the brake. WESSEL brake valves are additionally equipped with a stroke-dependent damping system: Small openings (range 1) with low damping are realized via an additional drain orifice. The further opening (range 2) is made with progressively increasing damping characteristics. A check-valve (CV 2) guarantees that the valve closes quickly. minor damping medium damping strong damping Subject to Modifications Version: LHW-3P_02E.doc 5/10

4.7 Feature 7: Opening pressure The valve is opened by the motor inlet pressure (lowering pressure). The opening point defines the pressure which opens the leakage free seat valve. For WESSEL load holding valves the opening point is independent of the load pressure! 4.8 Feature 8: Directional valve for mechanical brake Load holding valves of the design 3P have not provided any signal output for a mechanical brake and do not come with a switching valve for mechanical brakes. Subject to Modifications Version: LHW-3P_02E.doc 6/10

5 Installation 5.1 General Instructions Observe all installation and safety information of the construction machine manufacturer. Only technically permitted changes are to be made on the construction machine. The user has to ensure that the device is suitable for the respective application. Application exclusively for the range of application specified by the manufacturer. Before installation or deinstallation, the hydraulic system is to be depressurized. Settings are to be made by qualified personnel only. Opening is only to be performed with the approval of the manufacturer, otherwise the warranty is invalidated. The included connection recommendations are not guaranteed. The functionality and the technical specifications of the construction machine must be checked. 5.2 Connection Proposal 1 Pump 2 Main control valve 3 Pilot control unit 4 Load holding valve 5 Winchmotor 5.3 Mounting - Installation Space Observe the connection designations Observe the strength category and recommended torques (see appendix) of the fastening bolts Do not damage seals and flange surfaces The air must be exhausted from the hydraulic system Valve is mounted on the hydromotor by means of 4x cylinder head screws 8.8 SAE Thread A Thread depth B Torque Nm SAE CODE 62 ¾ M10 71,5 49 1 ¼ M14 93,5 135 5.4 Setting the pressure relief for the attachment a. Undo the counter-nut (1). b. Set screw (2) 1mm = 83 bar c. Factory pressure valve setting (please see type code) d. Tighten the counter-nut (1) Subject to Modifications Version: LHW-3P_02E.doc 7/10

5.5 Feature 7: Setting the opening pressure CAUTION! The opening point of the load holding valve is specified in Feature 7, adjusted at port X. Due to the pressure dividing function the pressure at MVSt is at a level than specified in Feature 7. Changes to the settings are only to be performed by authorized and trained personnel. The user is responsible for any changes made to the valve. A setting under 13 bar is not permitted, measured at MVSt. ATTENTION During operation, the valve can heat up to the oil temperature. Remove seal (factory status). Loosen the AF10 (1) counternut, left-hand thread (Locknut completely screw out at ¾ + 1 version) The opening start of the hose rupture valve must be approximately 0.5 bar above the opening start of the main control unit spool. Increase: Turn the set-screw AF8 (2) clockwise. Decrease: Turn the set-screws AF8 (2) counter-clockwise. An adjustment of 1mm thread corresponds a variation of the opening pressure fo 2,9 bar. Tighten the counternut AF10 (1). 5.6 Dimensions Size SAE ¾ Subject to Modifications Version: LHW-3P_02E.doc 8/10

5.7 Dimensions Size SAE 1¼ Subject to Modifications Version: LHW-3P_02E.doc 9/10

6 Notes, Standards and Safety Instructions 6.1 General Instructions The views in drawings are shown in accordance with the European normal projection variant A comma (, ) is used as a decimal point in drawings All dimensions are given in mm 6.2 Standards The following standards are to be observed because of the surface temperatures on the valve: EN 563, Temperatures on surfaces that can be touched. EN 982, Safety-technical requirements for fluid-technical systems and their components. 6.3 Safety requirements WESSEL-HYDRAULIK GmbH guarantees utilization of standard and proven safety principles in accordance with ISO 13849-2: 2003, Tables C.1 and C.2 for the construction of the valve described here. WESSEL-HYDRAULIK GmbH has a certified quality management system in accordance with DIN EN ISO 9001. The MTTFd value can be adopted from machine manufacturers with 150 years of experience for the described valve! Note: The user is therefore responsible for complying with the fundamental and proven safety principles according to ISO 13849-2: 2003, Tables C.1 and C.2 for the implementation and operation of the hydraulic component! Subject to Modifications Version: LHW-3P_02E.doc 10/10