PATCHMAX GS3, GS6 and PowerSUM Modular Panels

Similar documents
SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

UNP-U-Type Universal Panel Instructions

UNPWM-U-Type Universal Wall Mount Patch Panel Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

UNP610-WM-12P Modular Jack Panel Installation

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

SYSTIMAX Solutions. Asia-Pacific Ordering Guide (03/14)

How to remove and replace the Foonf/Fllo fabric

CM52 Network Protector with Arc Flash Reduction Module

FCategory 5e 110 Wiring

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

THE safety accessory of the 21 st Century.

Voice/Data/ Video Tools

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

Signal Mirror Installation Instructions

Fiber Connector Shelf (CCS)

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector S-FTP STP

Data sheet E-DAT modul Cat.6 A 8(8) jack, T568A

Bel Stewart Connector

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

Customer Owned Copper Outside Plant Guidelines

10260S Series Actuators Auto-Manual Switch Replacement Instruction

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SCION FR-S FOG LIGHTS

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Installing the Flame Ionization Detector EPC Flow Control Manifold

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

2015 Mustang Lightbar (All Models) CDC#

Job Sheet 6 Installing the Combiner Box

Brake Shoe: Service and Repair Removal Procedure

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

* * APPLICABLE MODELS: 2014 > Mazda 3

Switches 10AX/16AX. Safety. Easy Operation. Switch Mechanism. Characteristics of Urea Resin. Screwless Terminal (reduces installation work) Features

* * APPLICABLE MODELS: 2014 > Mazda 6

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

Shaver Industries. Assembly Instructions Vertical Vinyl Curtain Door DT2 Wire Rope Replacement

ET-PWR-END-KIT Installation Instructions (part #JSR00)

* * APPLICABLE MODELS: 2017 > CX-5

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

Fiber optic splice closure

GENUINE PARTS INSTALLATION INSTRUCTIONS

Installation Instructions: HYPERION R-Lite SYSTEM

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

How to Replace a Switch

2M Series Contacts and Tools

GENUINE PARTS INSTALLATION INSTRUCTIONS

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

MNBRATKIT MidNite Brat Solar Charging Kit

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

WARNING. Important Notice

ARB UTILITY MANAGEMENT SYSTEMS WATER ELECTRIC GAS. E-Coder)R900i Quick Install Guide. E-Coder)R900i QUICK INSTALL GUIDE

FIBER CONNECTOR SAFETY WARNINGS

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

PATCH PANEL Easy Patch INSTRUCTION MANUAL

Safe-T-element Installation Instructions

Installing the Switch

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

ELECTRICAL CONNECTORS B.1

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Data sheet C6 A RJ45 field plug pro

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

HEADLAMP ASSEMBLY. Service and Wiring Instructions with Diagrams. CAUTION Read this document before installing the snowplow.

Blowfish Racing, LLC 200 Old Love Point Road Stevensville, MD

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

SAFETY THIS PRODUCT IS FOR OFFROAD USE ONLY. ALL LIABILITY FOR INSTALLATION AND USE RESTS WITH THE OWNER.

S6 BATTERY REPLACEMENT

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

* * APPLICABLE MODELS: 2016 > CX-3

ISSUER: WRC 10/29/10 ENGINEERING: PROD/MTL: QA APPROVAL: REVISION HISTORY

HP Modular Cooling System 200/100 Options Installation Guide

Shielded Connector Block for the NI PXI/PXIe-2532/2532B

Valve Box and Valve Accessories G4315A, G4316A, G4317A

Chexit/RCM/DE5300. Chexit/RCM/DE5300 Service Parts. Chexit Field Wiring Cable. DE5300/RCM Field Wiring Cable. Table of Contents

8. Electronics assembly (B3/R2 design)

SCION xd INTERIOR LIGHTING UPGRADE Preparation

CASS Interface System Parts Section 1

Agilent G1554A On-Column Capillary Inlet with EPC

ACA-20PC Series Digital, LED-Display AC Ammeters with Built-in Current Transformers

Installation Instructions: ACCENT HIGH OUTPUT SYSTEM

Signal Mirror Installation Instructions

Transcription:

Issue C, October 2017 SYSTIMAX SYSTIMAX PATCHMAX GS3, GS6 and PowerSUM Modular Panels General The SYSTIMAX PATCHMAX GS3, GS6 and PowerSUM modular panels are available in a 24-port (2U) and 48-port (3U) version. These panels are approved components for use in SYSTIMAX GigaSPEED XL, X10D and PowerSUM systems. SYSTIMAX PATCHMAX panel systems are designed for premises high speed data and voice networks. Wire terminations can be performed from the front or rear of the frame. These panels can be used for EIA-T568A or EIA-T568B wiring applications. The panels use snap-in distribution modules, each with six modular jacks. Panel kits are available unpopulated for use with separately ordered modules. Note: PowerSUM modular panel no need termination manager kit. Ordering information is listed below: Material ID Part No. Description 760062356 PM-GS3-24 PATCHMAX GS3 Cat 6 U/UTP copper patch panel, 24-port, equipped with termination manager 760062364 PM-GS3-48 PATCHMAX GS3 Cat 6 U/UTP copper patch panel, 48-port, equipped with termination manager 760001669 PM-GS3-2U PATCHMAX GS3 24-port panel kit (without modules) 760001677 PM-GS3-3U PATCHMAX GS3 48-port panel kit (without modules) 760221564 PM-GS6-24 PATCHMAX GS6 Cat 6 U/UTP copper patch panel, 24-port, equipped with termination manager 760221572 PM-GS6-48 PATCHMAX GS6 Cat 6 U/UTP copper patch panel, 48-port, equipped with termination manager 760221580 PM-GS6-2U PATCHMAX GS6 24-port panel kit (without modules) 760221598 PM-GS6-3U PATCHMAX GS6 48-port panel kit (without modules) 760205260 PM-PS-24 PATCHMAX PowerSUM copper patch panel, 24-port (2U) 760205278 PM-PS-48 PATCHMAX PowerSUM copper patch panel, 48-port (3U) 760205286 PM-PS-2U PATCHMAX PowerSUM 2U panel kit (without modules) 760205294 PM-PS-3U PATCHMAX PowerSUM 3U panel kit (without modules) How to Contact Us To find out more about CommScope products, visit us on the web at / For technical assistance: - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or PartnerPRO Network Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795 or email to claims@commscope.com. 2016 CommScope, Inc. All rights reserved This product is covered by one or more U.S. patents or their foreign equivalents. For patents, see /ProductPatent/ProductPatent.asp px Page 1 of 8

Tools Required Outside the United States, contact your local account representative or PartnerPRO Network Partner. Phillips head screwdriver Cable jacket scoring tool D-914 punch tool with M110 blade Parts List Verify parts against the parts list below: Quantity 24-Port Panel 48-Port Panel 2U Panel Kit 3U Panel Kit 1 1 Panel 1 1 Panel frame Description 4 8 Rear label, T568A wiring 1 2 1 2 Cable management bar 28 56 Termination managers* 1 2 1 2 Label sheet, White (4 labels per sheet) 1 2 1 2 Label sheet, Blue (4 labels per sheet) 4 8 4 8 Hook-and-loop straps 4 4 4 4 Mounting screws 1 1 1 1 Instruction sheet *Not applicable for PowerSUM copper patch panel. Specifications Wire Terminations Wire Size: 22-24 AWG (0.64-0.51mm) Solid Copper 22-24 AWG (0.64-0.51mm) Seven Stranded Copper Insulation Size: 0.042-inch maximum DOD Insulation Types: Polyethelyne, Polypropylene, and FEP IDC Reterminations: 20 minimum Modular Jack Mating Cycles: 750 minimum Environmental Data Temperature Range: -40 F (-40 C) to 158 F (70 C) (Storage) 14 F (-10 C) to 140 F (60 C) (Operational) Humidity: 95% Noncondensing Separately Orderable Parts Modules for the PM-GS3 and PM-PS panel kits must be ordered separately and are listed below: Material ID Product Number Description 760065763 PM-GS3-DM PATCHMAX GS3 Category 6 U/UTP distribution module 760221606 PM-GS6-DM PATCHMAX GS6 Category 6 U/UTP distribution module 760205302 PM-PS-DM PATCHMAX PowerSUM Category 5e U/UTP distribution module Page 2 of 8

860584481 WARNING Important Safety Instructions When using this product, the following basic safety precautions should be followed to reduce the risk of fire, electric shock, and injury to persons: 1. Never install communications wiring in wet locations unless it is designed for wet locations. 2. Never install this product during a lightning storm. There is a remote risk of electric shock. 3. Never touch uninsulated communication wiring or terminals unless the communication circuit has been disconnected at the network interface. 4. Caution: All wiring that connects to this equipment must meet applicable local and national building codes and network wiring standards for communication cable. Step 1 Mount Panel to Rack Mounting screw (4 places) 1. Using four screws (included), attach panel to 19-inch rack. 2. Install retainer bar to rear of panel. Step 2 Populate Panel with Distribution Modules (For Panel Kits Only) Note: Distribution modules are ordered separately. 1. From the front side of the panel, insert the module into the desired panel opening. 2. Rotate the top of the module down so that the trunions fully engage with the panel cutouts. 3. Press on the top of the module so that it rotates up and locks in place. Page 3 of 8

Step 3 Cable Modules Front View Rotate and remove module Release snap Insert module posts into slots Attach designation label Attach retainer bar Replace module Route cables through panel opening Attach retainer bar Terminate cables Secure cables to retainer bar Route cables Rear View Call outs above correspond to items listed on next page. Page 4 of 8

860584481 Front Punch-Down Procedure 1. Release snap to disengage module from panel. 2. Rotate module downward and remove from panel. 3. Route an adequate length of cable through the module openings as shown. 4. Insert module posts into panel mounting slots and snap module into position. Note: The module comes with a T568B wiring designation label installed. If T568A wiring is desired, first remove the "B" type label and then place the "A" type label. Do not place the "A" type label on top of the "B" type label. 5. Prepare cable for IDC termination. Terminate conductors on the IDC terminals per the wiring diagram shown below and utilizing the termination manager. Use only single wire punch down tools. Correct procedure for using the termination manager is provided in the next section of this instruction. 6. Unsnap module, rotate and replace into original panel opening. 7. Attach rear retainer bar, ensuring that hooks fully engage into proper mounting features on the panel. 8. Route cables as shown. 9. Secure cables to retainer bar with supplied hook-and-loop strips ensuring there is adequate slack for front removal of module. 10. Attach designation labels provided on front of panel. Rear Punch-Down Procedure 1. Do not remove module from panel opening. 2. Disregard steps 1 thru 4 of Front Punch-Down Procedure and follow procedure for using termination managers (next section) to complete the termination. T568 Wiring Pairs B A 1 2 3 4 5 6 7 8 8 7 6 5 W W W W 2 1 4 3 4 4 BR GR 3 2 OR BL 1 BR OR 2 3 GR BL 1 Entry holes Lock tab (2 places) Entry holes Modular Jack Front of Panel IDC Connector Back of Panel Fold slots (4 places) Wiring Diagram Termination Manager* *Not applicable for PowerSUM copper patch panel. Page 5 of 8

Page 6 of 8

1 Patch 860584481 Panel Termination Manager Instructions The termination managers provide pair positioning, control, and strain relief features to the rear termination area of the panel. See Figure 1. Instructions for using the termination manager are listed below. Feed Pairs into Termination Manager (Figure 2) 1. Trim jacket back at least 3 inches (76mm) to expose twisted pairs. 2. Without crossing over or rearranging pairs out of the jacket, position pairs in-line per pair colors below: T568B Wiring Application (Shown) Blue, Brown, Orange, Green T568A Wiring Application Blue, Brown, Green, Orange 3. Insert pairs through 4 holes on top surface of termination manager, one pair per hole, as shown. 4. Continue to feed pairs through termination manager until resistance is encountered at the jacket. This will usually be about 1/4 inch (6mm) from the jacket. Fold Pairs into Slots (Figure 3) 5. Fold each pair over into adjoining slots on bottom end of termination manager. Conductor colors must be arranged in the slots as listed below: T568B Wiring Application (Shown) BL/OR Pairs Blue/Orange conductors on top BR/GR Pairs both White conductors on top T568A Wiring Application BL/GR Pairs Blue/Green conductors on top BR/OR Pairs both White conductors on top Important: Add twist as needed to align pairs with slots. Never remove twist for any pair. Do not allow pairs to untwist inside termination manager or inside cable jacket. 6. Ensure that both conductors of each pair are in slots completely without being pinched over bottom end surface. Entry holes Lock tab (2 places) Fold slots (4 places) Figure 1. Termination Manager Blue pair Brown pair Entry holes Top surface Green pair Orange pair Figure 2. Feed Pairs into Termination Manager Blue on top Orange on top White on top Figure 3. Fold Pairs Back into Slots Page 7 of 8

Snap Termination Manager onto Rear Housing (Figure 4) 7. Snap assembled termination manager onto rear housing with pair colors in proper position. Push on using the termination manager housing, not by pushing with the cable. (Ensure that both lock tabs on manager fully seat into rear housing). 8. After termination manager is snapped onto rear housing, untwist individual pairs fully and line up correct color conductor and white conductor with the label on the rear housing. Pairs folded back Seat Wires into IDC Terminal Slots (Figure 5) 9. Grasping each untwisted pair, push the conductors down into IDC terminal slots to seat them before punching down. Seat down into slots as far as possible. (It may be easier to use needle nose pliers to perform this task). 10. Using the D-914 punch tool with M110 blade on HI impact setting, punch down conductors making sure the tool is straight and that conductors fully engage in the IDC terminals. Stagger the punch-down tool up and down, so that it stays in alignment with the staggered terminal slots. Figure 4. Snap Termination Manager onto Rear Housing Remove twists, then push conductors down into terminal slots Recommendations to Aid Assembly 1. The termination manager should be snapped onto the rear housing immediately after the pairs have been fed and folded over into the slots. All termination managers should be installed on the panel before proceeding to seat and punch down conductors. 2. Flex cables down for easier access, then seat and punch down the entire top row of the panel. 3. Flex cables up for easier access, then seat and punch down the entire bottom row. Visible pair entry Figure 5. Seat Untwisted Pairs into IDC Terminal Slots Page 8 of 8