House Hydrant Installation Instructions

Similar documents
House Hydrant V1 FROST-FREE OUTDOOR WALL HYDRANT. aqu r FLUSH-MOUNT NON-FREEZE SELF-DRAINING.

House Hydrant V2 FROST-FREE OUTDOOR WALL HYDRANT. aqu r FLUSH-MOUNT NON-FREEZE SELF-DRAINING ANTI-SIPHON.

GTFLOW EXTENSION MANIFOLD ASSEMBLY INSTRUCTIONS

Installation Instructions

Installation Instructions 7024

SB-1821-E. Instructions for Models: What You Need To Know: Tools: Required: Need Help? For additional assistance or service call: Helpful:

Installation Instructions

Product Instructions. Mixing Station. Features. Specifications. Materials

Manifold Isolation Valves

INSTALLATION INSTRUCTIONS

Instruction Manual Includes:

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

LAWN SPRINKLER, IRRIGATION PUMP

Installation Instructions

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide

Installation Instructions

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Installation Instructions

FOR TECHNICAL ASSISTANCE

MrPEX 1 ½ " Brass Manifold Installation Guide

Installation Instructions

Installation and Maintenance Instructions

DISCONTINUED. Installation. Aerada 900 Series Futura Faucet. With Accu-Zone (AZ) Infrared Control

EDGEMERE DUAL CONTROL WIDESPREAD LAVATORY FAUCET INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PATIENCE

MrPEX 1 ¼ Stainless Steel Manifold. Installation Guide

Installation Instructions

Installation Instructions

Installation Instructions

Fluid-O-Tech ROTOFLOW ROTARY VANE PUMP REBUILD MANUAL

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Installation Instructions

Installation/Care/Use Manual

Installation Instructions

CAUTIONS AND WARNINGS

SHOWER TIMER INSTALLATION INSTRUCTIONS Battery model 500

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

Frost-Proof Wall Hydrant Installation, Use & Repair Guide

GENERAL INSTALLATION MANUAL

CHEMTROL TRIPLE SPACE SAVER CLEANING STATION #U16242 INSTALLATION INSTRUCTIONS

Installation Instructions

AUTO REWIND AIR HOSE REEL

INSTALLATION INSTRUCTIONS

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

Installation Instructions

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

INSTALLATION & OPERATING INSTRUCTIONS

Clean Water Made Easy

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

FOR TECHNICAL ASSISTANCE

Installation/Care/Use Manual

Installation & Programming Manual. Quick Reference

D/G-03 Maintenance. Shutdown Procedure During Freezing Temperatures. Daily. Periodically

MUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2

Full Flow Drinking Water System Model: 3MFF100

AMEREC STEAMBATH GENERATOR (MODEL: AV2, 2KW/120 VOLT) SAVE THESE INSTRUCTIONS

Instructions. Certifications. Two Handle Kitchen Faucet. Tools Required. Maintenance. Safety Tips. Important Points. Things You May Need.

Paint/Solvent/Dump Valve and Flow-Through Valve

Installation Instructions

Installation Instructions 1662SG SG.222

Installation Instructions

INSTALLATION INSTRUCTIONS

AEROMOTIVE Part # /2 4.6L SOHC Ford Fuel Rail Kit INSTALLATION INSTRUCTIONS

Installation Guide. Engineering Excellence. Single Handle Tub & Shower Valve Set: 4020B

AEROMOTIVE Part # & Stealth Fuel Tank Sump INSTALLATION INSTRUCTIONS

Installation Instructions

Identify and Assemble the Pneumatic Components

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

# and # FAST Fuel System Kits

Installation Instructions Pro Bandit Shifter Fits: GM Powerglide Automatic Transmissions

Installation Instructions

TTS GOLF ROTOR OWNERS MANUAL

Andreja Premium Direct Connect Installation Instructions Chris Coffee Service

INSTALLATION MANUAL 2000WCY

SB-75 Installation & Operation Manual

Oil Drain Plug Repair Kit. 5. Boring tool (drill bit) 1. Oil cap with regulator. 6. Alignment tool. 2.

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

Installation Guide. Single-Control Bath and Shower Trim A K K K 12021

Installation Instructions

Milano AUTOMATIC FAUCET

Installation Instructions JASMINE Spread Lavatory Faucet with the EverClean Finish & Speed Connect Drain

Installation Instructions

Elite Skimmer Installation Manual. Manufacturers of Quality Pond Equipment & Supplies Item #PBESIM

Installation Kitchen Faucet Filtration System Instructions GXK285JBL

Patent Pending EXTENDED-DUTY PISTON PUMP

THANK YOU FOR CHOOSING BATHERBOX GETTING STARTED WHAT S IN THE BOX? N. Northview Ave Sioux Falls, SD 57107

METERS Data Collection CONTROL. Installation Guide. Residential Water Meters

PRO RATCHET UNIVERSAL SHIFTER

INSTALLATION INSTRUCTIONS FUEL RAIL

Installation Notes for Ingersoll Rand KVG-123 Compressor Package (Up to 255 Gallon Sump Capacity) Ingersoll Rand KVG-123 Compressor Package

MUELLER. Super Centurion 350 Fire Hydrant. Reliable Connections. Inspection and Maintenance 2. Filling Oil Reservoir 3. Facing the Hydrant 4

Service Manual Air Tech Second Stage

Halsey Taylor Owners Manual

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

For assistance call T&M. Tubing and manifolds. installation guide

1-BUTTON DISPENSER INSTALLATION INSTRUCTIONS

Installation Instructions

WARNING. Important Notice

Transcription:

House Hydrant Installation Instructions Please read all instructions and warnings before installing. WARNING Failure to turn off water supply prior to installation can result in personal injury or damage to home. Professional installation recommended. The Aquor House Hydrant is for outdoor use only. This product should be installed in exterior walls of homes and buildings. The House Hydrant is for heated and insulated building walls only. The House Hydrant can only offer freeze protection if the ambient temperature around the rear valve is above freezing. In well-insulated walls, the House Hydrant will resist freezing down to outside temperatures of -30 F (-34 C). Aquor Connector must be disconnected and House Hydrant allowed to self-drain in freezing temperatures. Close the debris cover when House Hydrant is not in use. Install the hydrant in accordance with all applicable plumbing codes and regulations. 1

Step 1: Turn Off Water Supply Turn off the water to your existing faucet by using a shutoff valve found inside the house or basement behind the faucet, or by closing the main water supply. Open the faucet and a bleeder valve on the shutoff to drain any remaining water from the pipe. If your shutoff doesn t have a bleeder valve, the remaining water will drain out of the supply line when it is cut. With the shutoff valve and exterior faucet open, wait for the water to fully drain. Step 2: Measure Fitment Measure the distance from the exterior of your home s wall to where the hydrant will connect to your piping. Measure your House Hydrant from faceplate to end (including the copper or push-fit adapter you ll be using to connect to the supply line) and ensure that it will fit. Mark your piping at the correct length, then use a pipe cutter or hacksaw to cut it. Place a bucket under the cut to catch any water left. TIP If you plan on using a mounting block (see Step 4), make sure to take into account the added thickness when measuring your hydrant length. Step 3: Remove Existing Hose Bib (if needed) With the water supply line cut, head outside and unscrew the existing hose bib from the exterior of the home. Remove the handle, then the mounting screws on either side. Pull the hose bib out of the wall (wrench or pliers may be needed for more leverage). 2

Step 4: Prepare Wall To install your new Aquor Hydrant, a 1 ⅝ (40mm) entry hole is required. You may need to enlarge the entry hole in your home s wall if replacing an existing sillcock. 40 mm (1.575 ) NOTE If you are installing the hydrant on a surface that isn t flat or smooth, such as stucco or dutch lap siding, using a mounting block is highly recommended. A mounting block provides a level, 90 surface that allows the hydrant faceplate to sit flush against the wall. Mounting blocks are available at any hardware store and come in a variety of shapes and sizes to match your home s siding. Step 5: Test Fitment Test your new hydrant s fitment. Keeping the Aquor logo down, ensure the hydrant will line up correctly with the water supply line, then mark the position of the three screw holes in the faceplate for drilling. The included debris cover and wedge will keep the hydrant sloped downward at a 5 degree angle. CAUTION Debris cover and wedge must be installed for proper drainage and freeze protection. 3

Step 6: Attach Adapter The rear valve housing unscrews from the House Hydrant body counter-clockwise. This is how you access the rear valve and o-rings to clean or service your hydrant, if needed. You can use any male-threaded 1/2ʺ NPT adapter to connect to your supply line. All types of plumbing adapters, including sweat-on or push-fit adapters, are compatible with the House Hydrant. Use teflon tape and firmly tighten the adapter on the rear valve housing. The rear valve housing can be unscrewed up to 180 from full lock while still remaining sealed, so that you can easily align the hydrant on your home s exterior wall. TIP The Aquor House Hydrant works best when attached to PEX tubing. In addition to being easier to route and connect, PEX tubing also provides a second layer of freeze protection for your home because it is able to expand. Additionally, it provides an easy way to access the rear of the hydrant for future maintenance. When installing your hydrant, add a couple extra feet of PEX tubing in a loop, which will allow you to pull the entire assembly out from the exterior of the home. 4

Step 7: Connect to Supply Line With your adapter attached, screw the rear valve housing back onto the rear of the hydrant, making sure the internal spring and rod are correctly in place. Then, connect your water supply line. This process will vary depending on the type of plumbing you have in your home. With recommended PEX tubing, you can simply use a PEX expansion tool to stretch the tubing and then slip it onto the adapter. Step 8: Secure to Wall Insert the debris cover with integrated wedge between the hydrant faceplate and exterior wall. The wedge and cover must be installed, and are required to drain water from the hydrant when disconnected. Ensuring the Aquor logo is on the bottom, use the included screws to secure the hydrant to the home s exterior wall. Step 9: Test and Check For Leaks Test the cover operation to check that it opens and closes smoothly. Insert the Aquor connector and make sure the internal rod and valve open smoothly. Remove connector before proceeding. With the system disconnected, turn your water supply back on and check for any leaks from the interior and exterior. Installation Complete. 5

Appendix A: Maintenance The Aquor House Hydrant can be easily cleaned or serviced from the exterior of the home. With the water supply turned off, remove the three mounting screws in the faceplate, then pull the entire assembly outward. The PEX tubing will unwind and allow you to easily access the rear of the hydrant. With copper piping, the rear valve housing will stay inside the wall. Unscrew the body of the hydrant from the rear housing in a counterclockwise direction, making sure not to lose the internal spring or rod. The hydrant utilizes two internal o-rings that can be replaced if needed: one that closes the rear valve, and a second that seals the outer housing. Appendix B: Troubleshooting Problem: Hydrant is not flush with exterior wall. Solution: If you are attaching to a rough surface like stucco, use a mounting block. When drilling into hard surfaces such as stucco or brick, use the provided blue anchors. Problem: Hydrant faceplate is not level / rotated. Solution: The rear valve housing can be unscrewed 180 from full lock without losing its seal. Tighten the body into the rear housing fully, then unscrew counter-clockwise until the Aquor logo is on the bottom and the hydrant is level. Problem: Hydrant is leaking from body when disconnected. Solution: Check rear valve housing o-ring for damage. Ensure rear valve housing is tightened to hydrant body (within 180 of full lock). Ensure teflon tape was used to attach the hydrant to your adapter in step 6. Adapter should be firmly tightened to rear of hydrant. Problem: Hydrant is leaking from outlet when disconnected. Solution: Check for debris blocking the hydrant valve. Disassemble hydrant and inspect internal o-rings and rod for damage. Ensure rod and valve open and close smoothly without water. Problem: Hydrant is spraying water when connector is inserted. Solution: This is not a problem. Attach a garden hose to the connector and enjoy your water. 6