Battery Back-up BBM Owner's Manual. Please read this manual BEFORE installing your inverter

Similar documents
Battery Back-up Model: BBM-1225

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

DC to DC Step Up Converter Model: VTC305

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

AUTOMATIC BATTERY CHARGER

SunCharger Portable Solar Panel Models: SC-05 SC-10. Owner's Manual. Please read this manual before operating the units

PURE SINE WAVE DC-AC INVERTERS

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL

VTC1000 Series Voltage Converter. Installation & Operation Manual

VTC610 Series Voltage Converter. Installation & Operation Manual

IQS300 Series Quasi-Sine Inverter. Installation & Operation Manual

Installation & Operation Manual PWS1000R Rack Mount Power Supply

INSTALLATION & OPERATION MANUAL VTC605 SERIES VOLTAGE CONVERTER

INSTALLATION & OPERATION MANUAL VTC1505 SERIES VOLTAGE CONVERTER

INSTALLATION & OPERATION MANUAL PWS1505 SERIES POWER SUPPLIES

BCD600 Series Battery Charger DC. Installation & Operation Manual

Charging Kit MSK-90 MSK-135

A48 / A48B (base plate) BATTERY CHARGER

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Chek-A-Cell TM. Instruction Manual Rev A 8/12

IPS1000 Series Pure-Sine Inverter

Power Conversion Products

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Owner s Manual. DC-DC Step Down Converter

Switch Mode DC Power Supply with Battery Backup SEC-1223BBM

Magnum AC Coupled In a D3R battery box MND3RACCPLME 7/20/18

RU BMS Power Supply and Battery Management System Owners Guide

Pure Sine Wave Inverter 600W-24V User Manual

ELECTRONIC MARINE CONVERTER/CHARGER Owners Manual Models PD2020, PD2030, PD2040, PD2050, PD2060, PD2080

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

DC-AC MODIFIED SINE-WAVE INVERTER OWNER S MANUAL SI-750HP MODEL: Please read this manual before operating your inverter.

INSTRUCTION MANUAL FOR PC63 CAGE

Universal Battery Holder Operator s Manual

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Go Power! Manual. GP-Smart Charger

BCD610 DC Source Battery Charger

BATTERY SAVER LOW RIPPLE HO

SCC-MPPT Solar Charge Controller

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

SCC-MPPT Solar Charge Controller

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

SCC-MPPT Solar Charge Controller

Cruising Charger Series OWNER S MANUAL

Solar Charge Controller

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

20A Solar Charge Controller

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

USER S MANUAL GPC SERIES LOW VOLTAGE DISCONNECT. Galley Power LLC.

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

1000 Watt Pure Sine Wave Power Inverter, Users Manual

HYDRAULIC POWER PACK

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

6 & 12 Volt Battery and Systems Tester with 100 Amp Load

SAVE THESE INSTRUCTIONS

C&D VRLA Batteries Extended Run Time for Small UPS Machines

LESTRONIC II BATTERY CHARGER MODEL 19740

A39 UNIVERSAL SCR CHARGER

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

IPS1000 INSTALLATION & OPERATION MANUAL PURE-SINE INVERTER.

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

BATTERY & STARTER ANALYSER (BSA-12) User Manual

Microprocessor Controlled Multi-Stage 16V Automatic Battery Charger P/N User Guide

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

GSL Electronics Modified Sine Wave Power Inverters

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

OWNERS MANUAL JANUARY 2007 ISO

AUTO CHARGE D PUMP PLUS

CLEAN POWER TM CPS Series Operator s Manual

User Guide IGD Series

10 AMP ON BOARD BATTERY CHARGER

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

PVI 60KW, PVI 82KW, PVI 95KW

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

Pump Sentry. Models 812 PS & 1612 PS INSTALLATION INSTRUCTIONS

A32 (UPS) UNINTERRUPTIBLE POWER SYSTEM ECN/DATE CPN /06 INSTRUCTION DRAWING NUMBER: Page 1 of 11 INSTRUCTIONS FOR A32 - UPS

INSTALLATION & OPERATION MANUAL

MODEL A45M RECHARGER OPTION 116 ELECTRONIC TIMER

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

MIL-24/2600Q MIL-24/3200DQ

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

Powermaster IntelliCHARGER. Microprocessor Controlled Three-Stage 12V/16V Automatic Battery Charger P/N User Guide

A46 / A46F. Constavolt Float Rectifier INSTRUCTION MANUAL

ADI-125/750 ADI-125/1500 ADI-125/2500

72 in / 1,83 m SWIVEL TABLE

MM-AVR UPS Series User s Manual

Transcription:

Battery Back-up BBM-1225 Owner's Manual Please read this manual BEFORE installing your inverter

owner's MAnUAL index section 1 Safety Instructions... 3 section 2 Layout and Dimensions... 4 section 3 Description and Principle of Operation... 5 section 4 Installation... 7 section 5 Operation and Protections... 9 section 6 Specifications... 11 section 7 Warranty... 12 Disclaimer of Liability UNLESS SPECIFICALLY AGREED TO IN WRITING, SAMLEX AMERICA, INC.: 1. MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. 2. ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSSES, DAMAGES, COSTS OR EXPENSES, WHETHER SPECIAL, DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USERS RISK. Samlex America reserves the right to revise this document and to periodically make changes to the content hereof without obligation or organization of such revisions or changes. copyright notice/notice of copyright Copyright 2016 by Samlex America, Inc. All rights reserved. Permission to copy, distribute and/or modify this document is prohibited without express written permission by Samlex America, Inc. 2 SAMLEX AMERICA INC.

Section 1 Safety Instructions 1.1 Precautions when working with batteries Batteries contain very corrosive diluted Sulphuric Acid as electrolyte. Precautions should be taken to prevent contact with skin, eyes or clothing. Batteries generate Hydrogen and Oxygen during charging resulting in evolution of explosive gas mixture. Care should be taken to ventilate the battery area and follow the battery manufacturer s recommendations. Never smoke or allow a spark or flame near the batteries. Use caution to reduce the risk of dropping a metal tool on the battery. It could spark or short circuit the battery or other electrical parts and could cause an explosion. Remove metal items like rings, bracelets and watches when working with batteries. The batteries can produce a short circuit current high enough to weld a ring or the like to metal and thus cause a severe burn. If you need to remove a battery, always remove the ground terminal from the battery first. Make sure that all the accessories are off so that you do not cause a spark. SAMLEX AMERICA INC. 3

Section 2 Layout and Dimensions 2.1 LaYout 2 1 4 3 5 LegenD: Fig. 2.1: Input Side Fig. 2.2: Output Side 1. Positive Input Terminal 2. Negative Input Terminal 3. Common Negative Output Terminal for Load and Battery 4. Positive Output Terminal for Load 5. Positive Output Terminal for Battery note: All input and output terminals: Hole size: 5mm / 0.2"; Set Screw: #10, 24 TPI, 5/16" long 2.1 DiMensions 114 2.9 4.3 5.5 R2.5 Height: 47.5 mm 98.8 2.9 93 2 22.15 35.7 22.15 note: All dimensions are in mm. Fig. 2.3: Dimensions 4 SAMLEX AMERICA INC.

Section 3 Description and Principle of Operation 3.1 DESCRIPTION This unit is used to allow any 12 VDC / 24 VDC power supply (with rated Current Limit value of up to 25A) to function as a DC Uninterrupted Power Source (UPS). This unit is a passive device and functions only as an interface between the external power supply, the battery and the DC load. As long as the power supply is operating normally, it will supply the load as well as float charge the battery. In case the output of the power supply fails, the battery will start feeding the load immediately thus, ensuring uninterrupted DC power to the load. During this period, the battery will start discharging. Once the output of the power supply is resumed, the power supply will take over the load and will also re-charge the battery at its float voltage. 3.2 PRINCIPLE OF OPERATION i INFO Explanation given below is based on use of external power supply with "Constant Current Limit" value of 25A. In a Constant Current Limit Power Supply, when the Current Limit value is reached, the output voltage will not be regulated and will drop. FUSE F1 32V, 25A (FAST BLOW) EXTERNAL POWER SUPPLY + INPUT R1 + BATTERY + BATTERY R2 + INPUT D1 D2 D1,D2 SCHOTTKY DIODE, 30V/30A R1,R2 POWER RESISTOR 1R2 (1.2 OHM), 25 WATTS + LOAD + LOAD FUSE F2 32V, 25A (FAST BLOW) Fig. 3.1: Schematic and Installation Diagram Please refer to the schematic and installation diagram at Fig. 3.1. SAMLEX AMERICA INC. 5

Section 3 Description and Principle of operation External power supply is connected to the Positive and Negative input terminals. The battery is connected to the battery terminals through Fuse 1 and the load is connected to the load terminals through Fuse 2. The voltage from the power supply is fed through the isolating Schottky Diode D1 to the load and to the battery through the charging current limiting resistors R1 and R2. Diode D1 provides isolation between the power supply and the battery to prevent the battery from feeding back into the power supply circuit. D1 has a forward voltage drop of up to 0.5V. Hence, the voltage available to the load and to the battery for float charging will be up to 0.5V lower than the output voltage of the power supply. in a battery backup application, the battery will normally remain in a fully charged, standby condition most of the time. it will discharge to the load only when the power supply fails. under this standby application, the battery should be charged at the recommended float voltage. Assuming the standby float charging voltages of 12V / 24V Sealed Lead Acid (SLA) Batteries to be 13.5V to 13.8V and 27V to 27.6V ( at 60ºF to 77ºF) respectively, the output voltage of the power supply should be adjusted as follows: Power supply Voltage for 12V sla battery backup: adjust to 14V The output voltage of this unit for the load and for float charging of the battery will be 14V minus drop of up to 0.5V across diode D1 i.e. around 13.5V. Power supply Voltage for 24V sla battery backup: adjust to 27.6V The output voltage for the load and for float charging of the battery will be 27.6V minus drop of up to 0.5V across diode D1 i.e. around 27.1V. As long as the external power supply is operating normally, it will supply the load as well as charge the battery through resistors R1 and R2, each 1.2 Ohm, 25W ( R1 and R2 are connected in parallel and will provide a net series resistance of 0.6 Ohm). note: as the external power supply is required to feed the load as well as charge the battery, the current rating of the power supply should be at least 20% more than the sum of the maximum load current and the maximum charging current (4a for 12V and 8a for 24V). If the power supply fails, the load will be supplied by the battery through the Schottky Diode D2. As in the case of Schottky Diode D1, there will be a forward voltage drop of up to 0.5V across D2. Thus, when the battery is supplying the load, the voltage seen by the load will be up to 0.5V less than the battery voltage. Note that Schottky Diode D2 is connected in parallel with resistors R1 an R2 and is used to bypass resistors R1 and R2 when the battery is discharging through the load. Maximum battery charging current Lead Acid Batteries should not be charged at very high charging current. The maximum recommended charging current of a battery is normally related to it s Ah (Ampere Hour) capacity, designated as C (based on 20A Discharge Rate). The maximum charging current for an SLA battery is normally specified within a range of C/5 (0.2C) to C/10 (0.1C). 6 SAMLEX AMERICA INC.

Section 3 Description and Principle of Operation Battery Backup Application Using 12V, 40-100 Ah Battery This Battery Backup Unit has been preset for battery backup application for a 12V battery of approximately 40 to 100 Ah capacity with the maximum charging current limited to approximately 4A (At power supply voltage set at 14.0V and battery discharged to 11.1V). Battery Backup Application Using 24V, 40-100 Ah Battery When using this unit in the preset condition for 24V, 40-100 Ah battery backup application, the charging current will increase approx. two times to 8A (At power supply voltage set at 27.6V and battery discharged to 22.3V). Calculating Maximum Battery Charging Current Maximum battery charging current Ib = {(Vp Vd) Vb} divided by Rs. Equation 1 Vp = Output voltage of the power supply (14V for 12V battery and 27.6V for 24V battery) Vd = Forward voltage drop across Schottky Diode D1 (up to 0.5V) Vb = Battery voltage Rs = Equivalent series resistance. In this case, R1 (1.2 Ohm) and R2 (1.2 Ohm) in parallel = 0.6 Ohm (See Fig 3.1). Assuming the voltages of fully discharged 12 V and 24 V batteries to be 11.1V and 22.3V respectively (at Discharge Rate of around C/10 (0.1C) Amps), the maximum charging currents will be as follows as per Equation 1: For 12 V battery backup = (14V 0.5V 11.1V) divided by 0.6 Ohm = 4A For 24 V battery backup = (27.6V 0.5V 22.3V) divided by 0.6 Ohm = 8A SECTION 4 Installation 4.1 INSTALLATION DIAGRAM AND DIMENSIONS Fig 3.1 shows the installation diagram. Dimensional details are given at Fig 2.3. 4.2 CABLE SIZING, TERMINATION AND FUSING The size of the cables used to connect the power supply, the battery and the load to this unit will depend upon the maximum value of the current flow and the length of the cable run. Current flowing through a cable will produce an undesirable voltage drop along the length of the cable. The voltage drop is proportional to the resistance of the cable. Higher resistance produces higher voltage drop. The resistance of the cable increases as the cable becomes thinner. Similarly, the resistance increases with the length of the cable. It is desirable to limit the voltage drop to 2% which will be 0.24V for 12V battery and 0.48V for 24V battery. SAMLEX AMERICA INC. 7

Section 4 installation A battery can supply very heavy current in case of short circuit in the path across its terminals. This can cause overheating of the cables / connected device(s) and consequent risk of melted insulation and possibility of fire. Hence, for safety, a fast acting fuse of appropriate current capacity should be connected in series with the Positive cable and should be placed within 7" of the Positive terminal of the battery. Automotive Blade Type of Fuses, Type ATO/ATC may be used. The following Table gives the recommended sizes of cable and fuses for external power supply rated at 25A. table 4.1 sizing of cable and Fuses current cable Length up to 3 ft cable Length up to 6 ft Fuses F1, F2 25A #12 AWG #8 AWG 32V, 25A The terminals have a tubular hole of diameter 5 mm with set screw for connecting the input and output cables. If the bare end of a multi-stranded cable is used directly, the set screw may not pinch all the strands firmly and will result in a loose connection which will cause voltage drop and excessive heating. For a firm connection, the cable ends should be terminated with suitable pin type of terminal. 4.3 adjusting output VoLtage of external Power supply Before the external power supply is connected to this unit, it is to be ensured that the output voltage of the power supply is adjusted to the required voltage as explained under Section 3.2. 4.3 connections Switch off the power supply. Connect the Positive and Negative output of the power supply to the input terminals of the unit marked INPUT + and INPUT respectively (1,2 in Fig 2.1). Connect the DC load to the terminals marked LOAD + and LOAD (4, 3 in Fig 2.2) Connect the battery to the terminals marked BATTERY + and BATTERY (5,3 in Fig 2.2)! caution! Ensure correct polarity of all connections. 8 SAMLEX AMERICA INC.

SECTION 5 Operation and Protections 5.1 OPERATION! CAUTION! Please ensure that the rated output current of the 12VDC or 24VDC power supply is only up to 25A. As already stated at in Section 3.1, this unit is a passive device and functions only as an interface between the external power supply, the battery and the DC load. Switch ON the external power supply to power on the load and also to start charging the battery. If the power supply fails or is switched OFF, the load will be immediately fed by the battery. When the load is supplied by the battery, the battery will start draining and its voltage will continue to drop. During this time, the voltage at the Load Terminals (4&3, Fig 2.2) will be up to 0.5V lower than the voltage at the Battery Terminals (5&3, Fig 2.2) due to the Forward Voltage Drop across the internal Schottky Diode D2. 5.2 PROTECTING THE BATTERY AGAINST DEEP DISCHARGE For longer life, Lead Acid Batteries should not be allowed to discharge more than 80%. For example, a 12V / 24V loaded battery at load current of C/10 Amps (C is the Ah capacity) will be 100% discharged at around 11V / 22V and 80% discharged at 11.5V / 23V. It is recommended that a suitable Low Voltage Disconnect Device, also called Battery Guard, may be used in series with Positive line of the load for protection against deep discharge of the battery. Battery Guard, Model No. BG-40, made by Samlex America, Inc. may be considered. 5.3 OVERLOAD AND SHORT CIRCUIT PROTECTION i INFO Explanation given below is based on use of external power supply with Constant Current Limit value of 25A. In a Constant Current Limited Power Supply, when the Current Limit value is reached, the output voltage will not be regulated and will drop. If the load tries to draw current higher than the current limit value of the external power supply (25A), the output voltage of the external power supply will not be regulated and the voltage at the Load Terminals (4&3, Fig 2.2) will drop. Portion of overload current beyond the current limit value of the external power supply (25A) will now be fed from the battery and the battery will start draining at this differential current. The voltage at the Battery Terminals (5&3, Fig 2.2) will start dropping and will be equal to the voltage corresponding to state of discharge of the battery. The voltage at the Load Terminals (4&3, Fig 2.2) will be up to 0.5V below the voltage at the Battery Terminals (5&3, Fig 2.2). External 25A Fuse (F2) on the load side will blow. SAMLEX AMERICA INC. 9

Section 5 operation and Protections In case of short circuit on the load side, the external 25A Fuse (F2) on the load side will blow because of very high additional current supplied by the battery (Additional battery current supplied into the short circuit on the load side = Short circuit current minus 25A from the external power supply). i info Over current protection provided by a fuse is determined by its Time versus Current Characteristic. For example, based on the Time Current Characteristics of 32V, 25A Blade Fuse Type ATC-25 from Cooper Bussmann, the fuse can pass extremely high currents for shorter durations as follows and will blow at 25A continuous for > 100 sec: 550A for 10 ms 170A for 100 ms 40A for 1 sec 25A continuous (for > 100 sec) 5.4 Protection against reverse PoLaritY of battery connection! caution! Please ensure that the polarity of battery / load connection is not reversed. This unit does not provide protection to the external power supply / load against reverse polarity connection. This protection has to provided by the user in case the power supply / load do not have integral protection against reverse polarity. Damage to the external power supply / load due to reverse polarity of battery / load connection is not covered by warranty. 10 SAMLEX AMERICA INC.

SECTION 6 Specifications Model No. INPUT INPUT VOLTAGE FROM EXTERNAL POWER SUPPLY INPUT CURRENT FROM EXTERNAL POWER SUPPLY OUTPUT OUTPUT VOLTAGE External Power Supply is ON and is supplying power to the Load and charging the Back Up Battery. OUTPUT VOLTAGE External Power Supply is OFF. Backup Battery is supplying the Load and is getting discharged. OUTPUT CURRENT External Power supply is ON and is supplying power to the Load and charging the Battery. OUTPUT CURRENT External Power Supply is OFF and External Battery is supplying power to the Load. BBM-1225 NOTE: Specifications are subject to change without notice. 14VDC for 12V Battery / 27.6VDC for 24V Battery Load Terminals: Up to 0.5V less than Input Voltage Load Terminals: Up to 0.5V less than voltage on Battery Terminals Load Terminals: = Rated Amps of External Power Supply minus Battery Charging Current Max limit = 25A Up to maximum of 25A Battery Terminals (Battery fully charged): Up to 0.5V less than Input Voltage Battery Terminals: Voltage equivalent to State of Charge of the battery Battery Terminals (Battery Fully Charged): Up to 0.1% of Ah capacity of Battery Load Terminals: Maximum limit = 25A OTHER EXTERNAL BACK UP BATTERY Lead Acid: 12V/24V, 40Ah to 100Ah ENVIRONMENT OPERATING TEMPERATURE RANGE 0 C to 40 C / 32 F to 104 F DIMENSIONS (W x D x H), MM 98.8 x 114 x 47.5 (W x D x H), INCHES 3.9 x 4.5 x 1.9 WEIGHT KG 0.3 LBS 0.7 Battery Terminals (Battery not fully charged): Voltage equivalent to State of Charge of the battery Battery Terminals (Discharged Battery): 12V Battery: Up to 4A (at 11.1V) 24V Battery: Up to 8A (at 22.3V) SAMLEX AMERICA INC. 11

Section 7 Warranty 2 Year LiMiteD warranty The BBM-1225 are manufactured by Samlex America, Inc. (the Warrantor ) is warranted to be free from defects in workmanship and materials under normal use and service. The warranty period is 2 years for the United States and Canada, and is in effect from the date of purchase by the user (the Purchaser ). Warranty outside of the United States and Canada is limited to 6 months. For a warranty claim, the Purchaser should contact the place of purchase to obtain a Return Authorization Number. The defective part or unit should be returned at the Purchaser s expense to the authorized location. A written statement describing the nature of the defect, the date of purchase, the place of purchase, and the Purchaser s name, address and telephone number should also be included. If upon the Warrantor s examination, the defect proves to be the result of defective material or workmanship, the equipment will be repaired or replaced at the Warrantor s option without charge, and returned to the Purchaser at the Warrantor s expense. (Contiguous US and Canada only) No refund of the purchase price will be granted to the Purchaser, unless the Warrantor is unable to remedy the defect after having a reasonable number of opportunities to do so. Warranty service shall be performed only by the Warrantor. Any attempt to remedy the defect by anyone other than the Warrantor shall render this warranty void. There shall be no warranty for defects or damages caused by faulty installation or hook-up, abuse or misuse of the equipment including exposure to excessive heat, salt or fresh water spray, or water immersion. No other express warranty is hereby given and there are no warranties which extend beyond those described herein. This warranty is expressly in lieu of any other expressed or implied warranties, including any implied warranty of merchantability, fitness for the ordinary purposes for which such goods are used, or fitness for a particular purpose, or any other obligations on the part of the Warrantor or its employees and representatives. There shall be no responsibility or liability whatsoever on the part of the Warrantor or its employees and representatives for injury to any persons, or damage to person or persons, or damage to property, or loss of income or profit, or any other consequential or resulting damage which may be claimed to have been incurred through the use or sale of the equipment, including any possible failure of malfunction of the equipment, or part thereof. The Warrantor assumes no liability for incidental or consequential damages of any kind. samlex america inc. (the warrantor ) www.samlexamerica.com 12 SAMLEX AMERICA INC.

NOTES SAMLEX AMERICA INC. 13

notes 14 SAMLEX AMERICA INC.

NOTES SAMLEX AMERICA INC. 15

contact information Toll Free Numbers Ph: 1 800 561 5885 Fax: 1 888 814 5210 Local Numbers Ph: 604 525 3836 Fax: 604 525 5221 Website www.samlexamerica.com USA Shipping Warehouse Kent WA Canadian Shipping Warehouse Delta BC Email purchase orders to orders@samlexamerica.com 11001-BBM-1225-0816