REC EPO STATUS BAT OUTPUT MUTE Critical Power Technical Data Sheet Uninterruptible Power Supply TLESM_UL_015-090_UPS front_01 GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland T +41 (0)91 / 850 51 51 F +41 (0)91 / 850 52 52 www.gecriticalpower.com imagination at work
Critical Power Model: Issued by: Approved by: TME Modular Series 15 to 90 UL S1 Product Document Department Riazzino - CH R & D Department Riazzino - CH Date of issue: 06/05/2018 File name: GE_UPS_TDS_TME_MUL_15K_90K_1US_V010 Revision: 1.0 Identification No.: Up-dating Revision Concern Date COPYRIGHT 2018 by GE Consumer & Industrial SA All rights reserved. The information contained in this publication is intended solely for the purposes indicated. The present publication and any other documentation supplied with the UPS system is not to be reproduced, either in part or in its entirety, without the prior written consent of GE. The illustrations and plans describing the equipment are intended as general reference only and are not necessarily complete in every detail. The content of this publication may be subject to modification without prior notice. Modifications reserved Page 2/6
REC EPO STATUS BAT OUTPUT MUTE DESCRIPTION The TME Modular Series UPS provides a compact footprint of less than 9.5 sq. ft. with maximum capacity of 90 kva/kw with best reliability and high performance. TME Modular Series is considered to be the best power protection solution. TLESM_UL_015-090_UPS front_01 FEATURES Modular design with N+X redundancy, on-line and hot-swappable. High power density with footprint of less than 9.5 sq. ft. up to 90 kva/kw. 15 kva/kw power module with only 3U height. Paralleling up to 270 kva/kw (3 cabinets) with optional parallel cable. Green and energy saving: ECO mode efficiency up to 98%, On-line up to 93%. Excellent input performances: power factor >0.99 while THDi <4%. Wide accepted input voltage range for maximum compatibility with stressing utility. Superior Battery Management enhances battery lifetime resulting in reduced cost of operation. Battery cold start: UPS can be powered on from the battery without utility. Lifetime monitoring of critical components, such as fans and capacitors. Independent LCD display for each power module with self-starting function. 9 signaling voltage-free contacts (4 programmable by user). SNMP card with iups Guard (GE UPS Remote Monitoring) 1-year free license included. User-friendly color touch screen of 10.4 inches. Built-in Maintenance Bypass and Backfeed Protection. Modifications reserved Page 3/6
SPECIFICATION Model Capacity Power Module type TME Modular Series 15 to 90 kva/kw UL S1 15 90 kva/kw, up to 270 kva/kw with 3 parallel cabinets 15PM General data System efficiency On-line: up to 93% ECO mode: up to 98% Battery mode: up to 93% Cooling air at PF=0.9 (77 F 86 F / 25 C 30 C, On-line) m 3 /h 15 kva: 1129 30 kva: 2258 45 kva: 3387 60 kva: 4516 75 kva: 5645 90 kva: 6774 Cooling air at PF=0.9 (77 F 86 F / 25 C 30 C, ECO Mode) m 3 /h 15 kva: 306 30 kva: 612 45 kva: 918 60 kva: 1224 75 kva: 1531 90 kva: 1837 Display 10.4 LCD color touch screen IP Class IP20 (IEC 60529 - ANSI/NEMA 60529) Interface 9 signaling voltage-free contacts (4 programmable) and SNMP card Operating temperature range UPS: 32 F 104 F / 0 C 40 C Storage temperature range UPS: -40 F +158 F Battery: -4 F +104 F (higher the temperature, shorter -40 C +70 C -20 C +40 C the storage time of the battery) Relative humidity 0 95% (non-condensing) Altitude of operation 1000m 1500m: -2.5% / 2000m: -5% / 2500m: -7.5% / 3000m: -10% General safety requirements for UPS used in operator access areas UL 1778 5 th edition Electromagnetic compatibility (EMC) requirements for UPS IEC/EN 62040-2, Category C3 (FCC PART 15 Class A as option) Transport On pallet- Cabinet suitable for handling by forklift (wheels for installation) External cable connections Rear side: top and bottom cable entry Audible noise level 65dB with 100% load / 62dB with 45% load (at 1 meter) Color RAL 9005 (black) Paralleling Up to 3 cabinets (option parallel cable) Input Phase 3 Phases + Neutral + Ground Voltage 208V / 120V (phase - phase) Frequency 60Hz Power factor >0.99 THDi THDi<4% with 100% linear load Voltage range 166Vac 261Vac (phase - phase), full load Frequency range 40Hz 70Hz Output Voltage 208V / 120V (programmable) THDu THD <1.5% with linear load / THD <6% with non-linear load Power factor 1.0 Crest factor 3:1 Overload Capability 110% for 1 hour / 125% for 10 minutes / 150% for 1 minute / >150% for 200ms Short-circuit characteristic 3 times In for 200ms between phase/phase and phase/n/pe Bypass Input connection Primary components Overload on bypass Short circuit withstand current Separate for rectifier and bypass input or common to the rectifier input Static switch (SCR) on bypass Circuit breaker (internal backfeed protection) on bypass 110% Long term operation (at 86 F / 30 C ambient temperature) / 110% 130% for 10min. / 130% 150% for 1min. / >150% for 200ms 65kA Output UPS power versus power factor for: Inductive loads Resistive loads Capacitive loads Modifications reserved Page 4/6
TLESM_UL_015-090_UPS dimensions_01 Battery Battery type Valve regulated lead-acid (VRLA), NiCd and Li-ion on request Float voltage at 68 F / 20 C 272V Number of cells VRLA at 2.27V/cell: 120 cells Min. discharge voltage (programmable) 198V Recharge current Up to 20% of the rated output power of PM (kw), programmable Recharge time <5 hours up to 80% of battery capacity Longer recharge time for long autonomy time / high load conditions Automatic and manual battery test Standard Common battery in parallel system Up to 3 cabinets (with same output power rating) Battery power data kva 15 30 45 60 75 90 DC power at full load & PF=0.8 lag. / PF=0.9 lag. kw 12.9/14.5 25.8/29.0 38.7/43.5 51.6/58.1 64.5/72.6 77.4/87.1 Maximum discharge current (1.65V/cell) Amps 65.2/73.3 130.3/146.6 195.5/219.9 260.7/293.3 325.8/366.6 391.0/439.9 Matching battery cabinets See option features on page 7 Dimensions and weights 31.50" / 800mm 43.31" / 1100mm UPS cabinet 617 lbs/ 280 kg Net weight Power module 15 kva/kw TME Modular Series 90 kva/kw (UPS with 6 power modules) 75 lbs / 34 kg 1067 lbs / 484 kg 75.00" / 1905mm Dimension (W x D x H) UPS cabinet Power module 15 kva/kw 31.50x43.31x75 inches 800x1100x1905 mm 18.11x31.10x5.28 inches 460x790x134 mm TME Modular Series 90 kva/kw (UPS with 6 power modules) 31.50x43.31x75 inches 800x1100x1905 mm Protections Protections for utility voltages (3 x 208Vac / 120Vac) UPS model Utility Input Bypass Input Common Input Utility External Battery TME Modular Series 15 3 x 70A 3 x 60A 3 x 70A 3 x 90A TME Modular Series 30 3 x 150A 3 x 110A 3 x 150A 3 x 175A TME Modular Series 45 3 x 200A 3 x 175A 3 x 200A 3 x 250A TME Modular Series 60 3 x 300A 3 x 225A 3 x 300A 3 x 350A TME Modular Series 75 3 x 350A 3 x 300A 3 x 350A 3 x 450A TME Modular Series 90 3 x 400A 3 x 350A 3 x 400A 3 x 500A Cable sections Cables section / Local Standard and cables installation disposal shall be applied UPS model Utility Input Bypass Input Common Input Utility Utility Output External Battery TME Modular Series 15 4 x AWG 3 + AWG 8 3 x AWG 4 4 x AWG 3 + AWG 8 4 x AWG 4 + AWG 8 3 x AWG 3 + AWG 8 TME Modular Series 30 4 x AWG 3/0 + AWG 6 3 x AWG 1/0 4 x AWG 3/0 + AWG 6 4 x AWG 1/0 + AWG 6 3 x AWG 3/0 + AWG 6 TME Modular Series 45 4 x 250 kcmil + AWG 6 3 x AWG 4/0 4 x 250 kcmil + AWG 6 4 x AWG 4/0 + AWG 6 3 x 250 kcmil + AWG 4 TME Modular Series 60 8 x AWG 3/0 + AWG 4 6 x AWG 1/0 8 x AWG 3/0 + AWG 4 8 x AWG 1/0 + AWG 4 6 x AWG 3/0 + AWG 3 TME Modular Series 75 8 x AWG 4/0 + AWG 3 6 x AWG 3/0 8 x AWG 4/0 + AWG 3 8 x AWG 3/0 + AWG 3 6 x AWG 4/0 + AWG 2 TME Modular Series 90 8 x 250 kcmil + AWG 3 6 x AWG 4/0 8 x 250 kcmil + AWG 3 8 x AWG 4/0 + AWG 3 6 x 300 kcmil + AWG 2 Modifications reserved Page 5/6
BC44 BATTERY CABINET TECHNICAL DATA BC44 Battery cabinet BC44 Battery cabinet front view 24" / 610mm right side view 42" / 1067mm 75" / 1905mm Dimensions (Width x Depth x Height) 24.00 x 42.00 x 75.00 inches 610 x 1067 x 1905 mm UPS (kva kw) 15 30 45 60 75 90 Runtime PF = 1 (min.) 9 No. batteries BC44 Battery cabinet (*) No. Cabinets Dimensions cabinet Cabinet weight (lbs/kg) Multi-Cabinets weight (lbs/kg) 1050 lbs / 476 kg 1050 lbs / 476 kg 13 1120 lbs / 508 kg 1120 lbs / 508 kg 18 1120 lbs / 508 kg 1120 lbs / 508 kg 31 20 1 1460 Lbs / 662 kg 1460 Lbs / 662 kg 46 1800 Lbs / 816 kg 1800 Lbs / 816 kg 59 2020 Lbs / 916 kg 2020 Lbs / 916 kg 73 2200 Lbs / 998 kg 2200 Lbs / 998 kg 5 17 1800 Lbs / 816 kg 1800 Lbs / 816 kg 20 1 23 2020 Lbs / 916 kg 2020 Lbs / 916 kg 1120 lbs / 508 kg 1120 lbs / 508 kg 11 1460 Lbs / 662 kg 1460 Lbs / 662 kg 29 2200 Lbs / 998 kg 2200 Lbs / 998 kg 42 2720 Lbs / 1234 kg 2720 Lbs / 1234 kg 46 59 2020 Lbs / 916 kg 4040 Lbs / 1832 kg 73 2200 Lbs / 998 kg 4400 Lbs / 1996 kg 7 13 2020 Lbs / 916 kg 2020 Lbs / 916 kg 20 1 16 2200 Lbs / 998 kg 2200 Lbs / 998 kg 1800 Lbs / 816 kg 1800 Lbs / 816 kg 24 2720 Lbs / 1234 kg 2720 Lbs / 1234 kg 26 35 2020 Lbs / 916 kg 4040 Lbs / 1832 kg 43 2200 Lbs / 998 kg 4400 Lbs / 1996 kg 62 2720 Lbs / 1234 kg 5440 Lbs / 2468 kg 7 9 20 1 2200 Lbs / 998 kg 2200 Lbs / 998 kg 2020 Lbs / 916 kg 2020 Lbs / 916 kg 15 2720 Lbs / 1234 kg 2720 Lbs / 1234 kg 17 23 2020 Lbs / 916 kg 4040 Lbs / 1832 kg 29 2200 Lbs / 998 kg 4400 Lbs / 1996 kg 42 2720 Lbs / 1234 kg 5440 Lbs / 2468 kg 50 2200 Lbs / 998 kg 6600 Lbs / 2994 kg 60 3 73 2720 Lbs / 1234 kg 8160 Lbs / 3702 kg 5 2200 Lbs / 998 kg 2200 Lbs / 998 kg 20 1 9 2720 Lbs / 1234 kg 2720 Lbs / 1234 kg 12 17 2020 Lbs / 916 kg 4040 Lbs / 1832 kg 21 2200 Lbs / 998 kg 4400 Lbs / 1996 kg 30 2720 Lbs / 1234 kg 5440 Lbs / 2468 kg 38 2200 Lbs / 998 kg 6600 Lbs / 2994 kg 60 3 54 2720 Lbs / 1234 kg 8160 Lbs / 3702 kg 78 80 4 2720 Lbs / 1234 kg 10880 Lbs / 4936 kg 6 20 1 7 2720 Lbs / 1234 kg 2720 Lbs / 1234 kg 2020 Lbs / 916 kg 4040 Lbs / 1832 kg 13 2020 Lbs / 916 kg 4040 Lbs / 1832 kg 16 2200 Lbs / 998 kg 4400 Lbs / 1996 kg 24 2720 Lbs / 1234 kg 5440 Lbs / 2468 kg 29 2200 Lbs / 998 kg 6600 Lbs / 2994 kg 60 3 42 2720 Lbs / 1234 kg 8160 Lbs / 3702 kg 62 80 4 2720 Lbs / 1234 kg 10880 Lbs / 4936 kg *) For further information please consult the Installation, Operation & Maintenance Manual of the BC44 Battery cabinet Modifications reserved Page 6/6