MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER

Similar documents
RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

OPERATOR S MANUAL Please read all the information in this booklet before using the unit.

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

Tension Control Unit Type Product Manual EUROTHERM DRIVES. Copyright Eurotherm Drives Limited Printed in England HA Issue 3

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

EasyStart Installation Instructions for Dometic Family RV A/Cs

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

NT-500 Technical Support Guide. For use by qualified company approved Technicians

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

EMPAC Metal enclosed capacitor bank for wind applications

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Introduction. System Components

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Model DS1000/DT20 System

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

C-Drive 7 Motor Control Unit For Electric Steering & Autopilots

FG Series, 230V ac Toroidal Single Primary Transformers

Condensation monitor

Endura AZ10 Oxygen probe Sensor sub-assembly tested spares kit

Model 340i / 680i / 1220i DC drive product manual HG iss 8 1

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

AUTOMATIC 12 WAY HEAT TREATMENT CONSOLE

The Power of Reliability INSTRUCTION MANUAL

FurnaceDoctor -DPT Dewpoint Analyzer. User Manual Version 008

SERIES VAC Microprocessor Based Direct Spark Ignition Control FEATURES DESCRIPTION APPLICATIONS THE TOTAL SOLUTION FOR GAS IGNITION CONTROL

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

PFC W HF/PFC Battery Charger

AFM500X Automatic Flashing Module

User Guide. Mini Maestro. Variable Speed Drive for Permanent-magnet DC Servo-motors. Part Number: Issue: 5.

Installation & User Instructions

PID-1500 THERMOELECTRIC & RESISTIVE HEATER TEMPERATURE CONTROLLER INSTRUCTION MANUAL

ELECTRICAL INSPECTOR EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET Time Allowed: Three hours

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

HD UNIT INSTALLATION & SERVICE BOOKLET 3-7

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

P66 Series Electronic Fan Speed Controls

Commander SK. Technical Data Guide. Model sizes A to D and 2 to 6. AC variable speed drive for 3 phase induction motors

Requirements for Secondary Voltage Revenue Metering (750 V and less)

SCR Power Controllers

Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1

Operating Instructions For The X-Seal Manual Thermal Sealer

Mclennan Servo Supplies Ltd. Bipolar Stepper Motor Translator User Handbook PM546

COATING THICKNESS GAGE NOVOTEST TP-1

Engineering Recommendation P26

INTRODUCTION... 2 ABOUT THE VALHALLA... 2 ABOUT THIS MANUAL... 2 RETAILER & DISTRIBUTOR OBLIGATIONS... 2 HOW TO USE THIS MANUAL...

MODEL 422 Submersible Pump Controller

INSTALLATION & OWNER'S MANUAL

INDEX Section Page Number Remarks

HILLSTONE DC LOAD BANK

Compact Sine Inverter

Stepper Motor Drive. Description: Specifications:

GP12 TECHNICAL MANUAL

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

INTECH Micro 2300-RTD6

DART Charger Product Description, Information and Specification

SPECTRA ENGINEERING PTY LTD. MXPS15 Series Technical Manual

FREEZSTOP MICRO SYSTEM. Freeze Protection of Pipework

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Installation Operation Maintenance ADDENDUM

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

ADI-125/750 ADI-125/1500 ADI-125/2500

HEAVY DUTY POWER RELAYS FEATURES

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Rental Industry Safety Tester Safe Check 5s

Power Switching Principles

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Technical Description

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

DC POWER SUPPLY ALIMENTATION C.C.

B BASIC HEAT TREATMENT CONSOLE

Distributed by SPECIALISED RUBBER PRODUCTS. Donut Springs Spring Covers Rubber Bumpers Tensions Bands

USER MANUAL 6 Position Powered Rack for TD Series Modules TDR 01 AC

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 22 November 2014 QUESTION AND ANSWER BOOKLET

Compact System NRGS 11-2 NRGS Original Installation Instructions English

REVISED ATM72 Auto Transfer Module

PEGASUS R MODEL 970. This manual is issued under the authority of. Mr. J.P. Tavener, Managing Director

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Displacement Sensor. Model 8739, 8740, 8741

Instruction Manual. Q Series 2 Motor Control Modules - OEM

SPECIALISED RUBBER PRODUCTS. Donut Springs Spring Covers Rubber Bumpers Tensions Bands

MX431 Generator Automatic Voltage Regulator Operation Manual

USER MANUAL 6 Position Front Connect Rack for TD Series Modules with 16 Channel Modular Front Panel TDP

Patient Care Facility

Integrated temperature test and calibration bench Model CBS-SC4000

Transcription:

MODEL 540 USER MANUAL INCORPORATING MODEL 530 TEMPERATURE CONTROLLER Signal Group Limited 12 Doman Road, Camberley Surrey, GU15 3DF England Tel: +44 (0) 1276 682841 Fax: +44 (0) 1276 691302 e-mail: instruments@signal-group.com Part Number 540ADD01

DOCUMENT HISTORY ISSUE AMENDMENT DATE 3 First Issue 28/01/87 4 ECN 910 03/06/93 5 ECN 944 28/09/ 93 5.01 REPRINT 15/05/03 2003 Signal Group Ltd. All rights reserved. No part of this manual may be reproduced, stored in a retrieval system or transmitted in any form or by any means - electronic, mechanical, photocopying, recording or otherwise - without the prior written permission of Signal Group Ltd. While we believe that the information and guidance given in this manual is correct, all parties must rely upon their own skill and judgement when making use of it. Signal Group Ltd. will not assume any liability to anyone for any loss or damage caused by any error or omission in the manual, whether such error or omission is the result of negligence or any other cause. Any and all such liability is disclaimed. Page 2 of 16

ADDENDUM TO The following caution applies to all issues of this manual, up to and including issue 5.01 CAUTION Take care to avoid skin contact with the line ends while disconnecting and transporting a hot line. Tightly coiling a hot line can cause the PTFE inner tubing to kink causing restricted flow next time it is used. Switch the controller off and allow cool air to purge through the line until it is cool (about 60 C to 70 C). If the line must be transported while still hot, only LIGHTLY coil it. SIGNAL GROUP LTD Page 3 of 16

INDEX SIGNAL HEATED LINES 1.0 INTRODUCTION 5 Page MODEL 540 ENCLOSURE 2.0 INTRODUCTION 6 3.0 SPECIFICATION 6 4.0 INSTALLATION 7 4.3 Wiring Schematic 8 5.0 OPERATION 9 MODEL 530 TEMPERATURE CONTROLLER 6.0 INTRODUCTION 10 7.0 SPECIFICATION 11 8.0 INSTALLATION 12 8.5 530 Installation Drawing 107009 14 8.6 530 Installation Drawing 107010 15 9.0 OPERATION 16 Page 4 of 16

SIGNAL HEATED LINE 1.0 INTRODUCTION 1.1 The SIGNAL Heated Line was primarily developed for carrying heated diesel exhaust gas to Hydrocarbon and NOx analysers such as the SIGNAL 3000 and 4000 series. If the temperature of the sample gas falls below the dew-point of the gas being measured, then the gas will become liquid and condense in the sample line. Since the analysers can only measure gases it is essential to avoid such condensation. 1.2 A constant high temperature must be maintained throughout the entire line assembly, and this is achieved by the use of a braided heating element. The braiding is made from stainless steel wire, which completely surrounds an inner PTFE tube. The whole is bedded in a silicone sponge for thermal insulation, and a sleeve of wire reinforced, anti-scuff, PVC hosing completes the assembly. 1.3 This method of heating ensures a constant high temperature throughout the sample line, with no cold spots. Despite internal temperatures of up to 200 degc, the efficiency of the insulation keeps the line relatively cool on the outside and therefore quite comfortable to handle. 1.4 The temperature of the braid is sensed by a type K thermocouple in thermal contact with, but electrically isolated from the braid. The thermocouple leads and electrical terminations to the braid, are brought out at one end of the line for connection to a temperature controller and isolating transformer. 1.5 Heating is achieved by passing a current through the braid to raise it's temperature. SIGNAL have designed the heating method with safety as a major consideration, and therefore an isolating transformer is supplied with the line. This transformer is designed and wound to suit an individual line, according to the voltage required to drive the correct current through the length of braid. 1.6 Temperature control is achieved by a solid state, purpose built controller, SIGNAL MODEL 530, which has been designed to drive the primary side of the isolating transformer. This gives a lower power loss in the controller. Special circuit techniques are used to reduce the high inrush current normally associated with transformer loads, and ensure that the DC component of the drive current is minimised. 1.7 The SIGNAL 540 ENCLOSURE, containing the 530 controller and the isolating transformer, provides a compact and transportable system for customers who wish to use heated line in a laboratory, or on site, and heated line facilities are not available in their own systems. SIGNAL GROUP LTD Page 5 of 16

540 ENCLOSURE 2.0 INTRODUCTION 2.1 The Model 540 enclosure provides a convenient, transportable package for the 530 temperature controller and isolating transformer that are required to control a length of heated line. 2.2 The enclosure is suitable for loads up to 1800 watts (20 metres) on 240 volt 50/60 Hz supplies and 900 watts (10 metres) on 110 volt 50/60 Hz supplies. An enclosure is customised for one length and size of heated line only. They are not interchangeable. 2.3 A 2 metre length of mains lead is provided for local mains connection which should be terminated with a fused plug to suit the outlet. 2.4 The heated line is attached via a 9 pin connector providing power and thermocouple connections. 3.0 SPECIFICATION 3.1 Mains Supply 200-260 Vac 50/60 Hz or 100-130 Vac 50/60 Hz Check serial number plate for detail. 3.2 Ambient Temperature 5 to 30 degc 3.3 Relative Humidity 90% non-condensing 3.4 Power Requirement 90 Watts/metre length of heated line plus 10 watts. Maximum 1810 watts. 3.5 Fuse Rating Depends upon length of heated line and mains supply. Fuse Part No. 240 Vac 110 Vac 3A FUS/021 0-200W 0-100W 7A FUS/022 200-360W 100-180W 10A FUS/023 360-760W 180-380W 16A FUS/024 760-1800W 380-900W 3.6 Temperature Control Range 0-200 degc 3.7 Size 225 mm width and depth 320 mm height 3.8 Weight Depends upon length of line 25 kg maximum excluding line. Page 6 of 16

4.0 INSTALLATION 4.1 Connect the mains lead to a suitably rated and fused connector with safety earth. The wires should be connected as follows:- Brown Blue Green/Yellow Live Neutral Earth 4.2 Connect the 9 pin plug on the heated line to the mating socket on the enclosure. 4.3 To prevent problems that can arise from connecting the wrong length line to the enclosure, the transformer secondary is fused and thermocouple connections are made to specific pins for particular load ranges. Thus the T/C ERROR indicator on the controller will be on if the thermocouple has gone open circuit ~ the wrong length line is fitted. These connections are shown on the wiring schematic 107308. SIGNAL GROUP LTD Page 7 of 16

Page 8 of 16

5.0 OPERATION 5.1 Switch on the mains supply at the local outlet. Check that the POWER indicator is on. 5.2 Check that the T/C ERROR indicator is off. If not, check that the serial numbers of the heated line and enclosure are the same. Check for a low resistance between the thermocouple leads, and for a high resistance between the thermocouple and heater leads. 5.3 Set the required temperature on the front panel control. Check that the HEATER indicator turns on showing that power is being applied to the line, and that it cycles on and off when the working temperature is reached. 5.4 The proportional band has been factory set to suit the heated line. This is the range over which power is proportionally applied and is centred around the set temperature. If the temperature control accuracy needs to be improved then the proportional band should be reduced. If the temperature overshoots the set point by an unacceptable level, then the proportional band should be increased. A small screwdriver can be used to adjust the P.BAND control, accessible from the front panel. One turn anticlockwise will reduce the proportional band by about 4 degc. One turn clockwise will increase it by about 4 degc. Adjust until an acceptable control is achieved. 5.5 Due to the method of heated line construction, small variations in temperature along the length of the line will be experienced. SIGNAL GROUP LTD Page 9 of 16

TEMPERATURE CONTROLLER 6.0 INTRODUCTION This section applies when the controller and heated line are supplied without the enclosure and are to be installed in an OEM or USER system. 6.1 The 530 temperature controller is designed to control the temperature of the SIGNAL HEATED SAMPLE LINE. The advantage of this unit is the ability to drive the primary side of the line transformer. The high surge current that can occur at switch-on is significantly reduced by special circuit techniques giving improved reliability and reduced line interference. This feature is not available on most standard temperature controllers. 6.2 An output is available to drive a solid state relay for loads greater than specified. The user must ensure that adequate heat sinking is provided for the relay. Page 10 of 16

7.0 SPECIFICATION 7.1 Mains supply 200-260 Vac 50/60 Hz 100-130 Vac 50/60 Hz Internally selected 7.2 Load - standard unit 1800 watts 240 Vac 900 watts 120 Vac Load with external drive unit. Part No. REL/001 5000 watts 240 Vac 2500 watts 120 Vac Heat sinking is required for the external drive component. It's base plate temperature must not exceed 90 degc. Maximum power dissipation is 30 Watts. 7.3 Temperature control range 0-200 degc Set by front panel control 7.4 Proportional band Screwdriver adjustable 0-100 degc (1 turn 4 degc) 7.5 Size DIN standard 96 x 96 nun 195mm overall length 200mm required behind panel 27mm required in front of panel 7.6 Weight 900 grams 7.7 Ambient Temperature 5-40 degc ambient temperature 7.8 Relative Humidity 90% non condensing 7.9 Fuse Rating Depends upon length of heated line and mains supply. 7.10 Factory settings Fuse Part No. 240 Vac 110 Vac 3A FUS/021 0-200W 0-100W 7A FUS/022 200-360W 100-180W 1OA FUS/023 360-760W 180-380W 16A FUS/024 760-1800W 380-900W looma FUS/445 Used when an external solid state relay is required Check the serial number plate for details. The unit is supplied with the correct fuse to suit the heated line and with the mains selector set to 240 volts. If specified on the order, the mains selector will be set to 110 volts. When supplied without a heated line, the mains selector will be set for 240 volts and a 16 Amp fuse will be fitted. SIGNAL GROUP LTD Page 11 of 16

8.0 INSTALLATION 8.1 Power Connections and Fuse Selection Power and transformer connections are made at the terminal block on the rear panel. They are labelled as follows going from left to right. H2 Hi L M E Transformer (switched) Transformer (live) Power Live Power Neutral Earth When the controller is supplied together with a heated line and transformer, a suitable rated fuse is factory fitted. When supplied on its own, it is fitted with a 16 amp fuse and is rated for the maximum load. This fuse will protect the controller. To protect a load of lower power rating a smaller fuse rating should be fitted. Suitable values and part numbers are given in section 7.9. 8.2 Thermocouple and other connections Input and Output connections are made at the rear panel 8 pin DIN connector as shown below. Pin 8 is the centre pin. Pin Connection 1 Thermocouple +ve 8 Thermocouple -ye 6 Temperature Output 10 mv/degc 5 Temperature output return 7 Control output for solid state relay (+ve) 3 Control output return 2 Not used 4 Not used * 7 6 3 8 1 5 4 2 * = polarising slot Page 12 of 16

8.3 120/240 volt operation The controller is factory set for the mains voltage requested. To change the operation voltage it is necessary to remove the top cover. WARNING Removal of the covers will expose the mains terminals and wiring. To ensure safety, always disconnect the unit from the mains supply and only allow qualified personnel to gain access. Remove the top cover. Identify SW1 between the main connector and the transformer. Set the switch to the 120V or 240V position according to the mains supply available. Refit the cover. Please ensure that you do not try to use a transformer on the wrong supply voltage. CHANGING THE SWITCH IN THE 530 DOES NOT ALTER THE TRANSFORMER RATING. 8.4 External Solid State Relay When extra long lines are to be driven, up to a maximum of 55 metres (28 metres for 120 Vac), a solid state relay, part No. REL/001 must be used to drive the transformer. It is important that only SIGNAL approved components are fitted to preserve the low surge current and noise features. This component must be provided with adequate heat sinking. The heat sink should be chosen to keep the base plate temperature below 90 degc when dissipating 30 watts. The effect of ambient temperature must be taken into account. In some circumstances, fan assisted cooling will be necessary. Refer to the installation drawing for wiring information. SIGNAL GROUP LTD Page 13 of 16

Page 14 of 16

SIGNAL GROUP LTD Page 15 of 16

9.0 OPERATION 9.1 Set the temperature control to the required position. 9.2 Apply power to the unit. Confirm that the POWER light is on and that the HEATER light is on and cycles on and off when the operating temperature is reached. 9.3 The proportional band control has been factory set for a 40 degc band. This is the range over which power is proportionally applied and is centred around the set temperature. If the temperature control accuracy needs to be improved, then the proportional band should be reduced. If the temperature overshoots the set point by an unacceptable level, then the proportional band should be increased. A small screwdriver can be used to adjust the P.BAND control, accessible from the front panel. One turn anticlockwise will reduce the proportional band by about 4 degc. One turn clockwise will increase it by about 4 degc. Adjust until an acceptable control is achieved. 9.4 If the T/C FAULT light is on then a fault exists in the line thermocouple, or in it's connections to the controller. Check for as low resistance between the thermocouple leads, and for a high resistance between the thermocouple leads and the heater leads. Trace the leads through to the controller and transformer and confirm that they are correctly wired. Page 16 of 16