Signature Series. Duplex Softener Service Manual

Similar documents
AQT-56SE ELECTRONIC SERIES PROGRAMMING MANUAL CONTROL VALVES

ProFloSE. Downflow Brining Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

Rayne Guardian Water Conditioner This manual contains information on setting the controller and normal operating maintenance required by the owner

Nitrate / Sulfate Manual

3200ET TIMER. Service Manual. IMPORTANT: Fill in pertinent information on page 2 for future reference.

DCS7 Water Softener - Product Manual

WS2H/ WS3 Error Codes

Trouble Shooting Guide for WS1 - WS2 Control Valves

BNT 85 /185 Valve Operation Manual

AQT-275 SERIES SERVICE MANUAL CONTROL VALVES

Model 7000XTR. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Installation and Operations Manual

5900e Carbon Filter Installation & Start-Up Guide

IWT 565 Series Valve Operation Manual

INSTALLATION, OPERATING AND SERVICE MANUAL

Isobar II Nitrate / Sulfate Manual

High Capacity Softener Manual

Nitrate / Sulfate Manual Installation / Operation Manual

MASTER. Water Conditioning Corp. Installation and Operation Manual. MCA Combination Series Residential Units

Softener Manual Installation / Operation Manual

Water Specialist EE Control Valve Programming and Cover Drawing Manual

or OWNER S MANUAL MODEL R

Installation / Operation Manual

SIMPLEX PREMIUM WATER SOFTENER INSTALLATION AND USER GUIDE

AQT-56 POWERFLO SERIES SERVICE MANUAL CONTROL VALVES

wd-2

65 Series. Valve Operation Manual

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

Nitro Filter Installation / Operation Manual

Provectr Plus Filter Manual

Water Specialist igen Control Valve Programming and Cover Drawing Manual

Signature 2 Signature 3

Water Specialist CI Control Valve Programming and Cover Drawing Manual

Water Specialist EI Control Valve Programming and Cover Drawing Manual

Superior Water And Air OWNER S MANUAL Model 32-CL770 & 48-CL770

FLECK 5800 LXT DOWNFLOW/UPFLOW SERVICE MANUAL

Superior Water And Air

WATER SOFTENER SEMI AUTOMATIC INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

6700XTR Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

Provectr Plus Filter Manual

Water Specialist PR Control Valve Programming and Cover Drawing Manual

Water Specialist CK and EQ Control Valve Programming and Cover Drawing Manual

Fleck 2510 Manual Sediment Filter Installation & Start-Up Guide

Impression Series. Installation Instructions & Owner s Manual. Metered Water Softeners

Installation Instructions & Owner s Manual. Omega Series Metered Water Softeners

Organic Scavenger Fleck Model 7000 SXT Series Operation and Service Manual

Problem and Solutions Manual

TotalCare, CareSoft Elite. and CareSoft Pro. Series. Twin Water Softeners and Conditioners. For Models: TC1-TW TC2-TW CSE-TW CSP-TW CSERC-TW CSPRC-TW

Evolve ES Series. Water Softeners. For Models: ES-844 ES-948 ES-1044 ES-1248 ES-1354

Evolve ES Series. Water Softeners. For Models: ES-844 ES-948 ES-1044 ES-1248 ES-1354

SIGNATURE 2. Signature 2. Installation / Operation Manual

Value Super Filter Max Installation Manual

Impression Plus Series Sanitizer Plus Series

Sanitizer Plus Series. Water Conditioners

Arsenic / Heavy Metals Filter Manual

Reactr VS Installation / Operation Manual

ADVANCE. Backwashing Filters and Tannin Filter. Installation Instructions & Owner s Manual

Impression Plus Series

Model 5600SXT Downflow

NUGEN Pure Water Systems Fusion XT. Installation Instructions and Owners Manual

Impression Plus Series

MGTE Series 1 1/2 Metered & Time Clock

7500 Greensand Filter Installation & Start Up Guide

300 HD-AP SERIES. 300 HD-AP Series Two Tank Iron / Sulfur Treatment Manual. Installation / Operation Manual

TotalCare Series. Water Conditioners

CareSoft. Series. Metered Water Softeners. For Models: UCS-844 UCS-948 UCS-1044 UCS-1054 UCS-1248 UCS-1354

300 SERIES. 300 Series Filter. Installation / Operation Manual

Sanitizer Plus Series

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

Owner s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual

Water Specialist 1 Control Valve Series Model: WS1CS 1.25 Control Valve Series Model: WS1.25CS

WATER SOFTENER SERIES DAY TIMER INSTALLATION & OPERATING INSTRUCTIONS. Serial No :

Filter Manual Installation / Operation Manual

Fleck 5600SXT Upflow. Service Manual TABLE OF CONTENTS JOB SPECIFICATION SHEET

Technical Manual. Models: Standard Softeners High Efficiency Softeners Combination Softeners S150 S250 S250 OD S350 S550 S650 S650 OD Q850 Q850 OD

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

Water Specialist 1.5, 2 and 2 QC Control Valve Drawings and Service Manual

Arsenic / Heavy Metals Filter Manual

Installation Instructions & Owner s Manual LINDYSPRING LCR Series II Water Conditioners

Error code explanation Diagnostics...2 Error Code Chart...3 Tests Wiring diagram...6

Model 5600SXT Upflow. Service Manual. IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

Water Specialist WS2H and WS3 Control Valve Drawings and Service Manual

Impression Plus Series

OZONE ZENTEC CAPSULATE FILTER INSTALLATION AND USER GUIDE

Signature 2 Signature 3. Arsenic / Heavy Metals Filter Manual. Installation / Operation Manual 1

Owner s Manual HELLENBRAND, INC.

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

Water Specialist 1 Control Valve Series Model: WS1CI 1.25 Control Valve Series Model: WS1.25CI

Organic Scavengers Fleck Model 2850 SXT Series Operation and Service Manual

Standby Generator Quick Reference Guide

OWNER S MANUAL FOR ALL GREENSAND SYSTEMS

300 HD-AP SERIES. 300 HD-AP Series Two Tank Iron / Sulfur Treatment Manual. Installation / Operation Manual

ProMate EcoMax Duo Twin Alt

Consumer s Filter Manual. ProMate 6.0 Iron Curtain Junior Filter Manual

Water Specialist 1 Control Valve Series Model: WS Control Valve Series Model: WS1.25

Series. Ion Pro and CareClear Pro. Water Filters. For Models: IPHS IPFE IPG IPCG-AN CCP CCP-AN

Owners Manual Installation Instructions. For Models PTCF PTCF PTCF

TTV Series. Softening Water System. Installation, Operation and Maintenance Manual. Revised 01/17/13

Chemical Free Iron Sulphur Filtration System Owner's Operation and Maintenance Manual

Transcription:

Signature Series Duplex Softener Service Manual

Control Start-Up Procedures System Overview Softener Slave Unit #2 (Forward Flow) Shuttle Valve Master Softener Slave Unit #1 (Reverse Flow) Connection to Brine Tank Inlet Outlet Page 2

Control Start-Up Procedures (Cont d) Home Display Un t1 CHANGE MENU ENTER SET Alternates between indicating which unit is in service (currently being used to soften the water) and how many gallons are remaining before that unit needs regenerated. If Softener Slave Unit #1 is in service the display will show [unt1]. If Softener Slave Unit #2 is in service the display will show [Unt2]. The gallons remaining will decrement as water is used. Once the gallons remaining gets to [0000] the shuttle valve will automatically switch the water flow to the Unit that is in standby. During the time that the shuttle valve is shuttling, the display will show the number of the softener unit that it is shuttling to and the last two digits will show rotating segments (ex. [2-'']). Once done shuttling the display will again show the Softener Unit that is in service and the gallons remaining. Also the Softener Unit that was just taken out of service will begin its regeneration cycle. Main Menu To enter main menu press the button. The first menu item is for display only. It shows the status of the Softener Unit that is not currently in service (the unit that is in standby). It will alternate between showing the standby unit (ex. [unt1]) and the current status of the unit. The following are the different status indications that may be seen when viewing this item: o [rdy ] This indicates that the standby unit is ready to go into service. o [1-''] This indicates that the standby unit is motoring to position #1 (Backwash position). The last two digits will be rotating the outer segments of the digit to indicate that the motor is running. The display will be the same when motoring to other positions, except that the first digit which shows the position number that is being motored to ( ex. Position 2 2, Position 3 3 ). o [1-05] This indicates that the standby unit is in position #1 and has less than five minutes remaining in that position. The time will count down in each position to zero and will then automatically motor the Softener Unit to the next position. The display will be the same for the other positions except for the first digit which shows the position number that the unit is in. Note: While viewing this menu the Softener Unit that is regenerating can be forced through the cycle steps. While the display is showing the position with time remaining (ex. [3-12]), press and hold the button until the display shows the unit motoring to the next position (approximately 3 seconds). To continue to the next menu item press the button. Menu/Enter Button Set/Change Button Page 3

Control Start-Up Procedures (Cont d) The second menu item is the hardness setting, and will show the current setting (ex. [H-25]), the entire display will be flashing. The hardness setting should be set according to the water hardness of the water being treated. If there are any questions as to what value this should be set to, please consult with your Signature Series Softener supplier. The hardness setting is used to calculate the number of gallons of water that can be treated between softener unit regenerations. o To edit this setting Press the button. o The lowest digit will begin flashing while the other digits are solid. o Press to change the digit to the desired value. o Press to accept the value of the current digit o Repeat last two steps for each digit. o Once the last digit is accepted all digits will flash. To continue to the next menu item press the button. The third menu item is the regeneration day override setting and will show the current setting (ex. [A-07], the entire display will be flashing. This setting adjusts the number of days between forced regenerations (if the unit has not been regenerated because of normal water usage). This number will get reset to the programmed setting after any regeneration, and will count down once every 24 hours. If it reaches zero it will force the shuttle valve to switch softener units and will begin regeneration of the unit that leaves service. o To edit this setting Press the button. o The lowest digit will begin flashing while the other digits are solid. o Press to change the digit to the desired value. o Press to accept the value of the current digit o Repeat last two steps for each digit. o Once the last digit is accepted all digits will flash. Notes: - Maximum Value is 29. - If value is set to 0, regeneration override will never occur To exit the Main Menu press the button. o Note: While in any part of the Main Menu, if no buttons are pressed for 60 seconds or longer the menu will automatically be exited. Page 4

Control Start-Up Procedures (Cont d) Flow Meter The Signature Series duplex softener has a built in flow meter. While at the home display, press and hold the button for approximately 3 seconds in order to view the flow meter. 05 31 CHANGE MENU ENTER SET The above example shows a water flow of 5.31 gallons per minute (gal/min). Notes: 1. The smallest continuous detectable flow is approximately 0.35 gal/min If the flow is below this volume the display will intermittently switch from showing 0.00 gal/min and some small flow value. 2. The flow meter value can be affected by plumbing connections. The value should be considered approximate and should not be used if a highly precise flow reading is needed. To exit the Flow Meter Menu press the button. o Note: While in the Flow Meter Menu, if no buttons are pressed for 60 seconds or longer the menu will automatically be exited. Battery Backup (Uses a Standard 9-Volt Alkaline Battery) Installing the Battery o To install the battery the back cover of the shuttle valve must be removed by removing the two back cover screws. o Next insert the battery into the battery holding clip and snap the 9 volt battery connector onto the battery. o Replace the back cover. Features of Battery Backup o The battery backup continues to count down gallons remaining during power failure. o The battery backup allows the motor to complete running to the next valve position if power fail occurs while a valve transition is occurring. o The battery backup allows a softener slave unit to motor to a rest position that minimizes potential water flow during the power outage. Once power returns, the softener valve will pick back up where it was when power was lost. Notes: During power failures, the display is turned off to conserve battery power. However, to confirm that the battery is working, press either button and the display will turn on for five seconds. When used without battery back-up, the unit acts like a standard mechanical valve when a power failure occurs, the unit stops at its current point in the regeneration position and then restarts at that point when the power is restored. Page 5

Control Start-Up Procedures (Cont d) Starting an Immediate Regeneration Cycle To Start Immediate Extra Cycle Press and Hold the Set/Change Button. After 3 Seconds the Regeneration Cycle will Begin See Main Menu section for viewing the cycle steps and the time remaining. As well as how to manually step through each cycle step. Regeneration Cycle Indications The Softener Regeneration Cycle steps can be viewed both in the Main Menu and also on the valve position indicator wheel on the softener slave valve. o Step 1: Backwash o Step 2: Brine Draw / Rinse o Step 3: Rapid Rinse o Step 4: Brine Refill Final Set-Up With Proper Valve Operation Verified: Valve Position Indicator Wheel 1. Add water in the brine tank to the top of the air check (Located inside the 4 brine well). Manually step one of the softener valves to the Brine Draw Position (Start an immediate Regeneration cycle and advance to the Brine Draw position, position step 2. See Main Menu section of the manual for details on advancing to the step 2). Allow the valve to draw water from the brine tank until it stops. Note: The air check will close at approximately the midpoint of the screened intake area on the air check, stopping the any more water from being drawn out. 2. Next, manually step the valve to the Brine Refill Position (position step 4) and allow the valve to return to Service automatically. 3. Once the valve is back in Service, check that there is about 3.0 to 5.0 above the grid in the brine tank. 4. Fill the brine tank with salt to complete Set-Up. The control will run automatically as water is used. Page 6

Basic Operation The reverse flow valve body is marked by a star on the flow direction arrows and an R just above the valve inlet and outlet ports. Page 7

Control Start-Up Procedures (Cont d) Error Codes An error can potentially occur on any of the three valves in the duplex system. If the error occurs on the Shuttle Valve the display will alternate showing [SHtL] and the error code (ex. [Err2]). If the error occurs on Unit 1 or Unit 2 the display will alternate showing the Unit (ex. [Unt1]) and the error code. When an error occurs, it is important to note which valve unit has the error code that is displayed. There are four (4) error codes which could indicate a possible problem with the control valve: Error 2 - Homing slot expected but not found. Valve will begin searching for home (Normal operation continues after valve finds home position) Error 3 - Encoder is not sending a position signal (Valve requires service to continue) Error 4 - Unable to find homing slot (Valve requires service to continue) Error 5 - Motor overload (stalled position or shorted motor) (Valve requires service to continue) Error 3 Explanation: The unit is not receiving position information from the encoder. This can be caused by the motor not running, or the position encoder not sending a signal. If an Error 3 occurs, first check to make sure all of your wires are plugged in completely. Then unplug the power supply, wait a few seconds and plug it back in. The valve will try to run again, listen for the valve motor trying to run and look to see if the indicator wheel is turning (only applicable for the softener slave Units 1 and 2). If the Error 3 returns again the valve causing the error will need to be serviced. Error 4 Explanation: The unit is not able to find the home position. The encoder wheel may be partially blocked, or the motor is not running smoothly (has intermittent hesitation or has partial internal gear failure). The valve causing the error will need to be serviced. Error 5 Explanation: The unit thinks the motor is locked. This can only happen when the valve is running the motor, it is not seeing any change in the position encoder signal, and the motor is overloaded. This usually alerts the presence of corrosion inside the valve clogging the system Page 8

Master Programming Mode Master Programming Mode To enter master programming mode, press and hold both the button and the button for 5 seconds. Note: All Master Programming functions have been preset at the factory. Unless a change is desired, it is NOT necessary to enter Master Programming Mode. Do not change these settings unless you understand the effect it will have on your softener system, or if Signature Series provider had directed you to make the changes. Regeneration Cycle Step Times (1)(2)(3)(4) Example [1-20] Step 1, 20 minutes - The first 4 items in the Master Programming menu set the duration of time in minutes for each regeneration cycle step. - The step number which is currently modifiable is indicated on the far left of the display screen. The number of minutes allotted for the selected regeneration step is displayed on the far right. o To edit this setting Press the button. o The lowest digit will begin flashing while the other digits are solid. o Press to change the digit to the desired value. o Press to accept the value of the current digit o Repeat last two steps for each digit. o Once the last digit is accepted all digits will flash. o Press while all digits are flashing to move to the next menu item. System Capacity in Grains Example [c032] 32,000 grain capacity - Press the Menu/Enter button. This display is used to set the system capacity in grains and is used in conjunction with the hardness setting to calculate total gallons of treated water available between regenerations. This option is identified by the letter c in the left digit. The maximum value for this item is 399. o To edit this setting Press the button. o The lowest digit will begin flashing while the other digits are solid. o Press to change the digit to the desired value. o Press to accept the value of the current digit o Repeat last two steps for each digit. o Once the last digit is accepted all digits will flash. To Exit the Master Programming Mode Press the Button Note: If no buttons are pressed for 60 seconds, the Master Programming Mode will be exited automatically. Page 9

Troubleshooting Guide SYMPTOM PROBABLE CAUSE CORRECTION 1. Softener fails to regenerate automatically Power supply plugged into intermittent or dead power source. Disconnected meter cable Improper control valve programming Defective power supply Defective circuit board or meter Defective drive motor 2. Loss of capacity Increase raw water hardness Brine concentration and/or quantity Connect to constant power source Reconnect cable Reset program settings Replace power supply Call dealer, Replace or repair Check motor operation by activating the service button on back of motor Reset unit to the new capacity. Keep brine tank full of salt at all times. Clean it yearly. Salt may be bridged. If using a salt grid pate, ensure refill water is over it. Resin fouling Poor distribution, Channeling (uneven bed surface) Internal valve leak Resin age Resin loss 3. Poor water quality Check items listed in #1 & #2 Bypass valve open Call dealer, find out how to confirm it. Clean the resin and prevent future fouling. Call dealer. Check distributors and backwash flow. Call dealer. Replace spacers, seals and/or piston. Call dealer. Check for resin oxidation caused by chlorine. Mushy resin. Call dealer. Check for correct bed depth. Broken distributors. Air or gas in bed: Well gas eliminator. Loose brine line. Close by-pass valve Channeling Check for too slow or high service flow. Check for media fouling. 4. High salt usage High salt setting Adjust brine tank refill time Excessive water in brine tank See symptom #7 Constant flow through the unit Improperly set hardness or regeneration day override programming Indicates plumbing leak (i.e. toilet tank) Reset programming Page 10

Troubleshooting Guide Cont d SYMPTOM PROBABLE CAUSE CORRECTION 5. Loss of water pressure Scaling/fouling of inlet pipe Clean or replace pipeline. Pretreat to prevent 6. Excessive water in brine tank and/or salty water to service Fouled resin Improper backwash Plugged drain line Dirty or damaged brine valve Plugged injector Low inlet pressure Excessive brine refill cycle time 7. Softener fails to use salt Check items listed in #1 8. Control cycles continuously Improper control valve programming Plugged/restricted drain line Injector is plugged No water in brine tank Water pressure is too low Brine line injects air during brine draw Internal control leak Faulty circuit board Clean resin. Pretreat to prevent Too many resin fines and/or sediment. Call dealer, reset backwash flow rate, and/or adjust Check flow to drain. Clean flow control Clean or replace brine valve Clean injector and replace screen Increase pressure to allow injector to perform properly. (20 psig minimum) Reset brine refill cycle time Check and reset programming Clean drain line and/or flow control Clean or replace injector and screen Check for restriction in BLFC. Ensure safety float is not stuck. Check brine tank for leaks. Line pressure must be at least 20 psi. Check brine line for air leaks Call dealer, check piston, seals and spacers for scratches and dents Replace circuit board 9. Continuous flow to drain Foreign material in control Call dealer. Clean valve, rebuild unit Internal control leak Valve jammed in backwash, brine, or Rapid rinse position Motor stopped or jammed Same as above Same as above Replace motor Page 11