SPH General Manual 400 Series

Similar documents
Operations & Maintenance Manual DFH-1000 DUCTLESS FUME HOOD

SPH-400 i Series General Manual

I-6500 Series. Industrial Applications. Operations & Maintenance Manual. Air Purifiers for. Manufactured. Serial number.

ivac TWIN Premium Turbine Dust Collectors

ZENOTEC Air + Instructions for Use. ivt (120 volt) & ivt25-912(230 volt)

quatroair.com AIR TECHNOLOGIES INC.

X-3400A, X-3500, X-3700 OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Quest DRY 150. Quest PowerHEPA 500. quest. Read and Save These Instructions. Quest PowerHEPA 500:

Further information: Berriman Associates Model 850P.2 Owners Manual

Installation & Operation Manual Chef Base

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

ARM-EVAC 50. Benchtop Plenum/Arm Extractor MANUAL NO REV. B

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Miracle State Of The Art Air Filtration System!

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

MODEL FA1 Mini Air Filtration System. Operations Manual

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Quest H5. Quest Dry. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. Quest H5:

RK Standby Battery Operator s Manual

Owner s Manual Phoenix Guardian HEPA System

Owner s Manual Phoenix Guardian HEPA System

DESKTOP CONTAINMENT SYSTEM

For ELECTRONIC INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS TO BE USED IN CONJUNCTION WITH: SERVICE GUIDE for Gage Unit

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Premium Turbine Dust Collectors

FA1 Series Air Filtration System. Operations Manual

Source Capture Air Purification System

PHOENIX GUARDIAN H. E. P. A. SYSTEM

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

User s Manual and Operating Instructions

MODEL 950C-NP-UV Installation and Owners Manual

PHOENIX MINI-GUARDIAN

MODEL FA5 Air Filtration System. Operations Manual

RK Standby Battery Operator s Manual

Owner s Manual Phoenix GuardianR

Owner s manual for installation, usage and maintenance


GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Model G14SD Vapor Management System

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

OWNER S MANUAL C O M M E R C I A L I N D O O R A I R Q U A L I T Y S O L U T I O N S. Total High Efficiency Particulate & Gaseous Filtration System

Loctite Air Filtration System Part Number EQUIPMENT. Operation Manual

CLEAN AIR WORKSTATION REVERSE FLOW. Installation and Operations Manual

Operating Manual PFB-2500

Owner s Manual Phoenix Mini-Guardian HEPA System

FAN POWERED HEPA FILTER UNIT

Omniaire 1000V Instruction Manual-8/05

Harvil 5 Foot Air Hockey Table

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

EXT DUCTLESS FUME HOOD

MODEL MA4210 Installation and Operation Manual Important:

ARM-EVAC 105. Central Filter Unit

2SHE Series Direct-Drive Shutter Fans

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

MODEL GS1-100 Air Filtration System. Operations Manual

Raydot LLC 24 Actuator (115 VOLT)

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

DESIGN-AIRE SL-RSR-EC. Installation and Operations Manual

Operating Manual MAC-21 VFD

Part No DROP IN POPCORN WARMERS Instruction Manual Model #2343, 2344, 2345

MAVERICK 7' POOL TABLE WITH TABLE TENNIS ASSEMBLY INSTRUCTIONS

MLS KICK-OFF TABLETOP SOCCER TABLE ASSEMBLY INSTRUCTIONS

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

AUTO-BREEZE Cotton Candy Machine Instruction Manual Model #3052

RENEGADE SLATE BUMPER POOL TABLE ASSEMBLY INSTRUCTIONS

Harvil 4 Foot Air Hockey Table

Environmental Series Air Curtains

Airistar 100GT Owner s Manual Airistar 100GT Air Purifier

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com BVX-100. Fume Extraction System _B

HURRICANE 54-IN FOOSBALL TABLE ASSEMBLY INSTRUCTIONS

HUSTLER 7' & 8' POOL TABLE ASSEMBLY INSTRUCTIONS

PLAYOFF 48" FOOSBALL TABLE ASSEMBLY INSTRUCTIONS

9' & 12' CHALLENGER SHUFFLEBOARD TABLE ASSEMBLY INSTRUCTIONS

ARM-EVAC 500 Central Filter Unit

Portable Air Purifiers

For BLOWER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Adjustable Angled Incline Conveyor Owners Manual with Operating Instructions

ESE Series Cast Iron Sewage Pumps

Installation & Operation Manual PWS1000R Rack Mount Power Supply

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

!"" #$% "!&' ( ( ) *

Operation Manual for ARM-EVAC 150 Fume Extraction System

SIDEKICK TABLETOP SOCCER ASSEMBLY INSTRUCTIONS

AUTOMATIC SUBMERSIBLE UTILITY PUMP

MAGNETOGRAPHIC PRINTER

EXT HEPA/CARBON FUME HOOD

The BVX-100 Fume Extraction System

COMPRESSED AIR LOADER MODEL: AL-1

Installation & Service Manual for Portable Fume Collector. Model PFC-800

Model 616 Rotating Disk Electrode Instruction Manual

Henny Penny Rotisserie Display Model SCD-6/8 TECHNICAL MANUAL

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION & OPERATION MANUAL

MODEL MC1500 Installation and Operation Manual Important:

High Velocity Series Air Curtains

MICRO-AIR AIR CLEANER INSTALLATION AND OPERATION MANUAL. MX3510 Includes Installation, Operation, and Service Instructions CAUTION

FD Conveyor for FD 260 Tabber

Transcription:

Operations & Maintenance Manual SPH General Manual 400 Series (SPH-415,416,425,426,4U6,4U5,4B5,4B6) Filename: Quatro/SPH-400 General 12/28/04 R6 ------------------------------------------------------------------------Engineering Clean Air----------------------------------------------------------- ------------- 30 Hymus Blvd., Montreal, Quebec, Canada H9R 1C9 Tel.: (514) 630-4444 Fax: (514) 630-4454

1.0 INTRODUCTION You are now the owner of a Quatro SPH system, an advanced effective indoor air purification system designed specifically to remove particulate matter and/or gas phase contaminants. You can expect a noticeable improvement in air quality as the SPH begins the process of reducing microscopic airborne particulate as well as harmful and odorous gases. 2.0 SAFETY PRECAUTIONS Read all of the instructions contained in this manual before operating this unit. Keep this manual, as it contains information for proper operation and maintenance. Keep all fastening hardware tight to ensure that the unit is in safe working condition. Disconnect power prior to accessing unit, when checking or replacing filters, or replacing motor brushes. All filters must be in place whenever this machine is in operation. Use only on a grounded electrical circuit; do not use any two-wire electrical prong adapters to defeat the three-pronged plug on the end of the cord. When servicing the motors be careful when touching the exterior of the motor as soon as it has been turned off; it may be hot enough to be painful or cause injury. With modern motors, this condition is normal when operated at rated load and voltage, as they are built to operate at higher temperatures. Do not substitute any other filters (particulate or chemical) for those supplied, as this will alter the design characteristics and may void warranty. DO NOT ACCESS UNIT UNLESS UNIT IS UNPLUGGED FROM RECEPTACLE (ITS POWER SUPPLY)! Warning: This is a class A product. In domestic environment, this product may cause radio interference in which case the user may be required to take adequate measures. 3.0 PRINCIPLE OF OPERATION The SPH features a progressive filtration sequence method of operation; 1) captures general particulate 2) HEPA filter removes microscopic particulate matter; 3) chemically adsorbs, reacts or scrubs toxic or nuisance gases; SYSTEM COMPONENTS CABINET: Attractive airbrushed finish. The SPH is mounted on casters to ease portability. STANDARD FILTER SEQUENCES (from top to bottom): BLOWER ASSEMBLY: The blowers are tested to ensure quiet, vibration-free operation. The blower(s) in the SPH-400 Series features a blower mounting system designed to reduce vibration and noise. CONTROLS: Externally visible: ON/OFF switch, fused internally, a potentiometer to adjust airflow as required. AIR SUPPLY: 2, 3 or 4 diameter collars, mounted on top of the unit c/w flexible hose. POWER CORD: 8 long electrical power cord. Page 2

FILTER SEQUENCES: General Purpose Filter Sequence 12 Filter Section Filter #1 Multi layer disposable polypad (Quatro PN: F069-071) Filter #2 2 pleated pre-filter (Quatro PN: F071) Filter #3 2 99.97% HEPA Filter (Quatro PN: F074) Filter #4: Activated carbon chemical 8 filter module ( Quatro PN: AG097) 6 Filter Section Filter #1 Multi layer disposable polypad (Quatro PN: F069-071) Filter #2 2 pleated pre-filter (Quatro PN: F071) Filter #3 2 99.97% HEPA Filter (Quatro PN: F074) Filter #4: 2 Activated carbon chemical filter module ( Quatro PN: AG072) Filter Sequence for dust only applications Filter #1 4 pleated 90% ASHRAE rated pre-filter (Quatro PN: F164) Filter #2 2 99.97% HEPA Filter (Quatro PN: F074) Filter Sequence for odor and gas phase only applications Filter #1 AG097 for 6 filter sections Filter #1 AG098 for 12 filter sections 4.1 UNIT SPECIFICATIONS Model SPH-400 Series Series (12 Filter Section) Dimensions: Height: 24 "(762mm) Length: 15" (381mm) Width: 12" (304mm) Model SPH-400 Series Series (6 Filter Section) Dimensions: Height: 18 "(457mm) Length: 15" (381mm) Width: 12" (304mm) Voltage / Current: max. 120/1/60 North American 12.3 amps, 230/1/50 European 8.2 amps Approximate Weight: 70 lbs.(32kg) Page 3

UNIT RECEIVING INSTRUCTIONS 5.1 UNIT INSPECTION Upon receipt, inspect unit for either visible or concealed damage. Damage should be immediately reported to transport company. Remove unit from its box. Shipped inside the box are top cover, c/w collars and hose inside the unit. PRE START-UP Filter Installation 1) Ensure that you have received all necessary filters 2) Upon removing the unit from its box, ensure the unit is standing on its wheels; 3) Ensure that blue gel has remained in track during transport ( If not please contact factory) 4) Remove plastic wrapping from AG097 chemical filter (individually packaged). Use the handles on the chemical filters to lower carefully into the unit. 5) Lower the filters into the unit in the following order: General Purpose 12 Filter Section a. AG097 (8 chemical tray) ensuring that the perimeter rests in the Gel or on the gasket b. F074 HEPA filter (gasket side down) c. F071 pre-filter holding frame d. F071 disposable pleated filter e. F069-071 multi layered pad 6 Filter Section f. AG072 (2 chemical tray) ensuring that the perimeter rests on the gasket g. F074 HEPA filter (gasket side down) h. F071 pre-filter holding frame i. F071 disposable pleated filter j. F069-071 multi layered pad Filter Sequence for dust only applications 1) 2 99.97% HEPA Filter (Quatro PN: F074) 2) 4 pleated 90% ASHRAE rated pre-filter (Quatro PN: F164) 3) F069-071 multi layered pad Filter Sequence for odor and gas phase only applications a) Filter #1 AG097 for 6 filter sections a) Filter #1 AG098 for 12 filter sections 1) Replace the Top Plate (ensure buckles on the unit match tabs on the Top Plate) and fasten top of the unit; adjusting latches as necessary to create a tight fit. 2) Plug unit into an appropriate grounded receptacle and turn unit ON 3) If unit is equipped with a remote system interlock ensure that the switch is in the auto position and that the 12VDC or 24 VDC interlock power is connected 4) When using an optional 9 pin Sub D connector interlock, the control voltage will be wired to Pin # 3 and Pin #4. With optional pressure/vacuum switches pins 5 & 6 can be used to carry a 12 VDC or 24 VDC control signal Page 4

Speed Control ON / OFF switch Pre-Filter Pad, PN: F069-071 Dust Filter, PN: F071 F071 pre-filter holding frame Power Source HEPA FIlter, PN: F074 Odor Filter, PN: AG097 Standard Control Panel General purpose filter sequence START-UP 1) Plug in the appropriate power for your SPH unit; 2) Connect hose to the unit 3) Ensure all filters are installed 4) Turn switch on SERVICE NOTE: It is important to change the filters when required to avoid the excess build up of pressure within the unit that will result in diminished airflow and ultimately poorer filtration performance. The pre-filters should be changed on a routine interval. WARNING: DO NOT OPERATE SPH UNIT UNLESS ALL FILTERS ARE IN PLACE. 7.0 BLOWER MAINTENANCE PROCEDURES DISCONNECT POWER PRIOR TO ACCESSING TOP LID OR MOTOR SECTION BELOW To access blower section, do the following: 1) Switch unit off and unplug power cord before servicing the blower; 2) Unlatch and remove top cover 3) Remove all filters ; 4) Turn unit upside down; 5) With a Phillips screwdriver, remove (4) screws at the base of unit and holding the casters, lift off base You should now see the blower plate ( either 1,2 or 3 blowers depending on model) Page 5

Blower access caster plate View of blowers once caster plate is removed BRUSH REPLACEMENT (Disregard this section for BRUSHLESS Units) SERVICE NOTE: Please note that if your system is equipped with carbon brushes they need to be replaced approximately every 500 hours of operation. The brushes should be replaced before they are completely worn. Waiting until the brushes are completely expired could result in motor damage. Periodic brush inspection is a good preventative maintenance practice. The brushes on the SPH system can be changed in less than 5 minutes with the use of a screwdriver BLOWER MAINTENANCE, CHANGING BRUSHES WARNING: Switch unit off and unplug power cord from wall before servicing the blower. Screws Figure 1 Figure 2 Figure 3 1) Using a phillips screwdriver, unscrew the 2 screws holding down each of 2 gold colored brush casings (see Figure 1) 2) Lift gold colored tab and lift/pull out each brush (Figure 2 shows right brush removed) 3) Replace each brush onto turbine motor, screwing down the phillips screws over tab. YOU DO NOT HAVE TO REMOVE TURBINE FROM UNIT TO CHANGE BRUSHES! To access motor, remove blower section door. TURBINE & BRUSHES are visible once door is removed. Page 6

7.2 REPLACEMENT OF MOTOR PLATE (C/W1,2 BLOWERS) QUATRO To remove the entire plate c/w blowers: Switch unit off and unplug power cord before servicing the blower 1) loosen the motor wire forks from the terminal strips and loosen ground wire 2) loosen 4 wing-nuts at the 4 corners of the plate 3) lift off plate carefully, avoiding control panel 4) replace with new plate 2 Blower Plate Assy 8.0 FILTER REPLACEMENT PROCEDURE. 1) DISCONNECT POWER BEFORE ACCESSING TOP PLATE. 2) To replace appropriate filter, remove 2 flexible hose and unclamp 2 clamps as shown below; 3) Remove top lid and pull filters out of the unit; Filter Access Clamp, PN: H233 Pre-Filter Access Door For Upflow units Disposal of both odor and particulate filters is the responsibility of the enduser. Please contact local authorities for proper and legal disposal of spent filters. Page 7

General Dust Only Odor Only Purpose Application Application 6 Section 12 Section Filters are placed with #1 at the top: and # 4 at the bottom of the unit Filter #1: Pre-Filter F069-071 F069-071 F069-071 Filter #2: Secondary Filter F071 F164 ------- Filter #3: Main filter F074 F074 ------- Filter #4: Chemical Filter AG097/AG072 ------- AG098 Replacement Filters : Qtybox Description Quatro P/N: 12 Pre-Filter Pad F069-071 6 2 Pre-Filter F071 1 4 Hi Capacity Filter F164 1 HEPA Filter F074 1 2 General Chemical Filter AG072 1 8 General Chemical Filter* AG097 1 12 General Chemical Filter* AG098 1 Brush Kit (4 brushes & 2 discharge pads) 120/1/60 AB011 * General purpose modules are filled with F100 media. * Modules containing special blends for specific applications will have different part # s 10.0 ANNUAL GENERAL INSPECTION The sealing integrity of the SPH-400 Series is essential. Every 12 months (during a filter change-out): 1) Verify sealing integrity of the chemical filter at the bottom of filter section (Gasket PN: H296 or Blue Gel) 2) Verify that the blue gel is in tact and providing a good filter seal 3) gasket under top cover plate (Gasket PN: H006). Page 8

11.0 OPERATION The air is drawn into the unit through the intake hose located at the top of unit. The air then passes through the various stages of particulate and odor / gas filtration. Powered by a motor/blower assembly, the clean air is then released through the bottom discharge grille into the floor of the room. 11.1 POSITIONING OF UNIT SPH should be placed as close as possible to debris generating machine. 11.2 REDUCTION IN AIRFLOW As the unit cleans the air, the filters are removing the particles of dust and debris in the air stream. As the filters accumulate debris (both visible and microscopic), a restriction on the blower/motor is created. As the restriction becomes greater, the air capacity delivered by the blower decreases rendering the unit less effective. Service Note: IT IS VERY IMPORTANT TO CHANGE PARTICULATE FILTERS ON A REGULAR BASIS TO AVOID DAMAGE TO MOTORS CAUSED BY LACK OF AIRFLOW AND OVERHEATING. 11.3 TROUBLESHOOTING GUIDE Symptoms Possible Cause Suggested Solution Unit will not start o Faulty Power supply o Return or supply grille blocked o Blown fuse o Unit not plugged into receptacle o Check power supply o Remove obstruction o Replace fuse (PN: E106) o Plug unit in Excessive noise o Blower wheel out of align o Replace blower High Amp Draw Insufficient airflow o Lack of restriction o Obstruction in system o Clogged filters o Ensure hose is attached from SPH equipment o Ensure filters are installed properly o Supply only Quatro replacement filters o Remove obstruction o Replace filters Excessive airflow O Filters not in place o Install filters Odor breaking through system Blue Gel is damaged O Chemical filter not sitting in blue gel O Chemical filters are consumed O Removing/Installing the chemical module excessively O Realign module so that the bottom is sealed in the gel O Replace chemical media Filters not in place O Scrape gel out of track and replace with new gel or a dense closed cell neoprene gasket 12.0 WARRANTY QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use and service for a period of one year from date of shipment. QUATRO's obligation under this warranty shall be limited to replacing any parts, thereof, which shall be demonstrated to have been defective. This is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness. QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage. No person, firm or corporation is authorized to assume for QUATRO any other liability in connection with the sale of these goods. Equipment, parts and material manufactured by others and incorporated in QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability to QUATRO Air Technologies Inc.Conditions and Limitations: This warranty does not cover abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of God, general wear and tear, modifications of the equipment or installation of a part not recommended by QUATRO Air Technologies, as well as operation of the equipment at voltages other than those specified by QUATRO Page 9

13.0 Additional SPARE PARTS QUATRO Consumables: Minor Components Qty/unit Description Quatro P/N: 1 Toggle switch E110 1 Fuse E106 1 12vDC Interface Switch E104 4 Blower plate Isolators H307 4 Casters H042 1 3 dia. Flexible hose H142 1 4 dia. Flexible hose H155 1 Blower Isolation Gasket H306-50 1 roll Filter Gasket H296/37ft 1 roll Filter Access Plate Gasket H006/50ft 2) Optional items 1) Sub D 9 pin connector can be incorporated to communicate with a manufacturers system. Standard wiring is as follows but customized pin in/ pin out arrangements may be used. Pin #3. + 24VDC input Relay. Pin#4.. VDC Input Pin #5.. + 24 VDC Vacuum Switch Pin #6.. + 24 VDC 2) Vacuum Switch can be used to monitor the pressure of the entire system. The pressure switch is adjustable by turning the set screw. Clockwise rotation will lower the set point value Counter-clockwise rotation will increase the set point value For Technical Assistance, call QUATRO Air Technologies inc. at (514) 630-4444 (in Montreal Canada). Please ensure that you have your equipment serial number available when calling (located next to the power cord). Page 10