Advanced Instructions

Similar documents
INSTALLATION INSTRUCTIONS FOR PART TRIGGER TRIGGER

MegaSquirt III for LS Style Engines. Hardware Install. 1. Disconnect and remove the battery from the vehicle.

MultiFunction Module (MFM) Installation Instructions

MegaSquirt III for Gen 3 HEMI. Hardware Install THE FOLLOWING SENSOR PART NUMBERS APPLY TO ALL HARNESSES FOR ENGINES 2004 TO CURRENT:

RF-425LCD PROFESSIONAL VEHICLE SECURITY SYSTEM INSTALLATION MANUAL (FOR AUTHORIZED DEALERS ONLY)

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

Ebling Back Blade Snow Plow Wireless Controller Kit Only sold by SnowplowsPlus.com and ControlAllWireless.com

-----

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

DLKEK3HN INSTALLATION INSTRUCTIONS

Gate Operators, Inc. Model 7100UL Residential & Medium Duty Commercial Slide Gate Operator INSTALLATION MANUAL

Installation instructions

Vehicle Security System

Installation Manual for Dodge 12V Cummins Version 3.7. Please read all instructions before the installation of the ATS Co-Pilot

MSD Circle Track LS Ignition Control PN 6014CT

Installation and Operation Guide

AIR CONTROL ACCESSORY KIT

INSTALLATION MANUAL. This unit is designed for professional installation only and must be installed by an authorized Silencer dealer.

56- Electric Latch Retraction Exit Devices Installation and Wiring Instructions

INSTRUCTIONS. 20 Circuit Wiring Kit Instructions October 2009, Speedway Motors, Inc.

Typical Marinette AC Wiring

Motorized Electric Latch Retraction

THROTTLE & RPM-ACTIVATED NITROUS CONTROL SYSTEM P/N 15970NOS

FIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER

Terminal/Alternator Auxiliary Terminal to Light to Regulator Fuse or Switch to Pumps

2 CHANNEL MULTI-PURPOSE RECEIVER

USERS GUIDE LO-21U LOCKOUT RELAY

BE 1 BODY ELECTRICAL SYSTEM

DOC # DOCSST-D 08/16/99

MM1 Installation Instructions

Vehicle Security System

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

ROCKLEA TRUCK ELECTRICAL. Sleeper Air NXT. Owner s Manual. Revision th March 2013

Crop Link Pump Control Wiring

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

INSTALLATION INSTRUCTIONS. Yamaha G19 Installation Notes

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

Gen INSTALLATION MANUAL

CTC 400 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

Auto-Level Troubleshooting (Old Platform) Electronic Control- Prior to 2009, Pressure Switch Control panel #s 2057, 2058, 2795, 2795B

2007-UP NAVIGATION INTERFACE MODULE (Infiniti/Nissan)

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

2004 Scion xa. PARKING LIGHTS (+) GREEN At Harness On Top Of Fuse Box DOOR TRIGGER (-) RED/WHITE In 9-Pin On Top Of Fuse Box

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

Shaved-B. Installation Manual & Operation Instructions

A WORD ABOUT PROPER GROUNDING

WIRING DIAGRAM AND INSTALLATION INSTRUCTIONS

Model 1550 Single Swing Gate Model 1650 Dual Swing Gate

For questions or technical support, 1. Wiring Reference:

ATS Diesel Performance INST. Installation Manual for 2003 Dodge Cummins Version 3.1

INSTALLATION GUIDE Table of Contents

GENERAL MOTORS SERVICE PARTS OPERATION 6200 Grand Pointe Drive, Grand Blanc, MI 48439

Installation Instructions

535T Window Automation System

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

MSD LS Ignition Control PN 6014/60143

MSD Kawasaki Jet Ski 750 Enhancer CD Ignition PN 4251

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System

Remote Starter Integration for the 2007 Toyota Camry equipped with the Smart Key System with Push Button Start

Installation Tips for your Crimestopper/ProStart Remote Start system (for GM vehicles) v1.01 updated 2/27/2012

Idle Timer Controller - A-ITC520-A Ford E Series Ford F250 - F Ford F250 - F550 (*B-ITC520-A) F650/F750

RS-340-EDP+ / RS-450-EDP+

Gas Valve Controller

jegs.com

Optional: Wiring a Relay for Gauge Controlled Output

CAUTION: REMOVE YELLOW WIRE AND TERMINAL FROM RELAY SOCKET

Installation Manual for Dodge 24V Cummins Version 3.1. Please read all instructions before the installation of the ATS Co-Pilot

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

Telephonic Car Alarm and Remote Starter Wiring Schematics

Step 1 Wiring your remote start. Installation Tips for your Remote Start system (for GM vehicles) V3.3 revised 9/12/2013

Model APS-101N Installation Manual

Model APS-510C Installation Manual Remote Control Vehicle Security System

P2149-BANK 2 (CYLINDERS 4-6) SHORTED HIGH OR LOW


PIM701 (Police Interface Module) Dodge Charger Pursuit

INSTALLATION MANUAL. Model: PLUS Vehicle Security

"WE'VE GOT THE EDGE ON SECURITY" INSTALLATION MANUAL AL-700 ATV / AL-900 ATV / AL-1000 ATV

Advanced EasyStart Troubleshooting

MSD 7AL-3, Ignition Control PN 7230

CruzPro. Volts Amps Amp-Hour Monitor VAH110. Other CruzPro Products. website:

Installation Instructions for: Channel Thermocouple Amplifier

OWNERS MANUAL LINK 2000-R IDEAL REGULATOR OPTION

CTC 200 Cab Trailer Communication Power Line Carrier Technology Communications for Trucks and Trailers

FM SECURITY AND REMOTE START SYSTEM

HYPPOETL HYPPO DUALETL 12 VOLT DC Swing Gate Operator

Relay Driver Applications Guide

PARTS AND CUSTOMER SERVICE BULLETIN

2 Way Security and Keyless Entry Installation Guide ca 1553

SCHEMATICS 2/29/2008

FOR AUTOMATIC TRANSMISSION AND DIESEL ENGINE VEHICLES

ALARM UPGRADE FOR FACTORY REMOTE KEYLESS ENTRY SYSTEM INSTALLATION PRECAUTIONS & WARNINGS

Installation Manual v3.0: Dodge Cummins. Please read all instructions before the installation of the ATS Co-Pilot

RS-X60-EDP / RS-X60-EDP+

50A Dual-Feed 5/5 GMT Total Front Access Fuse Panel

MSD 6LS-2 Ignition Controller for Carbureted and EFI LS 2/LS 7 Engines PN 6012

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

PROFESSIONAL INSTALLATION STRONGLY RECOMMENDED

AviStart 6500 Installation Manual

INSTALLATION MANUAL. Remote Mobile Security System. Model: PL50

TELORVEK EFI 5.0 Coyote Sequential Fuel Injection System Part # CY-11

Transcription:

Advanced Instructions Detailed wiring and installation instructions Monitor Battery #1 (and power the device) Connect the long red (positive) and black (negative) leads to the main battery. Many vehicles and vessels will have optional places to access 12 volts or 24 volts from a battery or a set of house batteries. You can connect your device to any battery or battery bank that you choose. Whichever you connect your main red and black leads to will become the source of voltage that you will monitor as battery #1. Be sure to make sure the device connection is un-switched. In other words, when you turn off the power to the vehicle or vessel, you want the device to remain connected to battery power. See the bottom of this document for a wiring reference. Monitor Battery #2 To hook up the device to a second battery (or bank of batteries), connect the pink wire to the positive side of that battery. Normally there is no need for a ground because the device is already grounded. If battery #2 in your vehicle or vessel does not share a ground with battery #1, then connect the ground from battery #2 to the device harness s black wire (pin #1). See the bottom of this document for a wiring reference. Continued on next page 1

Shore power sensor hardware) To utilize shore power monitoring, you need an optional Shore Power DC Adapter. We offer a certified adapter at our online store. 1. Connect the red lead from the Shore Power DC Adapter to the white wire from your device harness. 2. Connect the black wire from the Shore Power DC Adapter to the black wire (pin 16) from your device harness. 3. Before proceeding, make sure the shore power is disconnected. 4. Now it's time to attach the Shore Power DC Adapter to your vehicle or vessel s shore power. Tips If your vehicle or vessel has an AC outlet connected to shore power, simply plug in the Shore Power DC Adapter One good place to attach to your vehicle or vessel s shore power is where it goes into the AC charging system on your vehicle or vessel. To do this, cut off the 110v plug on the Shore Power DC Adapter and attach the two wires your shore power inlet. Be sure to use a qualified electrician for any high voltage wiring. You can test the shore power monitoring by turning on shore power to your vehicle or vessel and checking the product app or website. There will normally be about a 60 second delay. Temperature sensor hardware) Temperature monitoring can be added to your product by using an optional Temperature Sensor. We offer a certified temperature sensor at our online store. Attach the wires as follows: Temperature Sensor red wire to device harness s orange wire (pin 9) Temperature Sensor yellow wire to device harness s white/blue wire Temperature Sensor black wire to device harness s black wire (pin 19) Your inside temperature sensor should register within the next 4 hours. Continued on next page 2

Door switch and motion sensor alerts This product will work with alarm switches and equipment that can be set to a normally open condition. Attach one lead from your alarm equipment to the vehicle or vessel s ground. The other lead should be attached to the device harness s violet wire. See the bottom of this document for a wiring reference. Controls (requires additional hardware) With this product you can control up to three relays (or solenoids) that can turn on and off equipment on your vehicle or vessel. Use the device harness s green wire for Control #1 Use the device harness s brown wire for Control #2 Use the device harness s yellow wire for Control #3 These outputs provide a high-current, open-collector driver that can sink up to 150 ma each. In other words, they act as a 150 ma ground for the relay coil. Wiring example for controls Attach 12v (or 24v) DC to one side of the relay coil. Attach the device harness s green wire to the other side of the relay coil. Attach 12v (or 24v) DC to one side of the relay contacts. Attach a light to the other side of the relay contacts. This will provide DC power to the light when the sink is energized by the device. See the bottom of this document for a wiring reference. Monitor Bilge Pump Activity (Marine Vessels only) Many boat owners find it useful to keep track of bilge pump activity. Boat Command can keep track of the frequency and duration of bilge pump operation on your boat. To hook up the device to your bilge pump, simply connect the blue wire from your harness to the positive lead on your bilge pump. When your bilge pump cycles on, Boat Command will detect voltage and log the activity. You can test this by turning on your bilge pump and then checking your Boat Command app or website. There will normally be about a 60 second delay. To monitor a second bilge pump, hook up the gray wire to the second bilge pump as described above. See the bottom of this document for a wiring reference. 3

High water alarm (marine vessels only) To hook up the device to a high water alarm, you can tie into your boat's existing high water alarm switches. If your boat does not have a high water alarm switch, you can add one by placing a float switch at a level a 2 inches (typically) above your bilge pump switch. Attach one lead from the high water alarm float switch to the device harness orange wire (pin 12). The other lead from the high water float switch should be attached to the boat's ground. See the bottom of this document for a wiring reference. Continued on next page 4

Boat Command Wiring Reference Purpose Description PIN Color Battery #2 To battery #2 (positive) 5 Pink Bilge counter To positive side of bilge pump 3 Blue Bilge counter #2 To positive side bilge pump #2 7 Gray High water High water switch (to gnd.) 12 Orange Entry alert To door or motion sensor (NO) 6 Violet Shore power DC adapter) Temperature temperature sensor) To dc adapter positive lead 8 White To dc adapter negative lead 16 Black To temp. sensor: black 19 Black To temp. sensor: yellow 17 White/Blue To temp. sensor: red 9 White/Orange Control 1 Relay coil sink (150ma) 2 Green Control 2 Relay coil sink (150ma) 10 Brown Control 3 Relay coil sink (150ma) 11 Yellow RV Command Wiring Reference Purpose Description PIN Color Battery #2 To battery #2 (positive) 5 Pink Bilge counter To positive side of bilge pump 3 Blue Entry alert #1 To door or motion sensor (NO) 12 Orange Entry alert #2 To door or motion sensor (NO) 6 Violet Shore power DC adapter) Temperature temperature sensor) To dc adapter positive lead 8 White To dc adapter negative lead 16 Black To temp. sensor: black 19 Black To temp. sensor: yellow 17 White/Blue To temp. sensor: red 9 White/Orange Control 1 Relay coil sink (150ma) 2 Green Control 2 Relay coil sink (150ma) 10 Brown Control 3 Relay coil sink (150ma) 11 Yellow 5

Need help? Contact us 918-824-1400 between 9am-5pm CST support@rv-command.com 6