Powered by Cummins K38 Series. Genset Standby Power :820KW. Basic Characteristics of Diesel Generator Set

Similar documents
Powered by Dongfeng Cummins 4B Series Engine. Genset Prime Power Range: 27kw-80kw. Basic Characteristics of Diesel Generator Set

WPS60/S EP Series. Features:

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

WPS100/S EP Series. Features:

WPS20/S EP Series. Features:

WPS350/S EP Series. Features:

WPS150/S EP Series. Features:

WPS250/S EP Series. Features:

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

Technical specification

GMS350C/S EC Series. Features:

GMS200C/S EC Series. Features:

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

GMS100C/S EC Series. Features:

FE - C KW / 650KVA 600KVA

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

Standby Power(60Hz) Prime Power(60Hz) 170KW / 212KVA 160KW / 200KVA. Standard Features

Diesel Generating Set

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Diesel Generating Set

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

CGT Stamford UCI 274 E1

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Dual Frequency Diesel Genset

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

Diesel Generating Set

1 / Genset general description

DGP-25 MF. 1 / Genset general decription. > Open genset with automatic start-up, control card allows automatic, manual or signal start-up.

DIESEL GENERATOR DATA SHEET

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

1 / Genset general description

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS352KW 380/ / / / / / / / /

PPU Diesel Power 50/60Hz Containerized Generator Set

Water-Cooled DEUTZ BF6M101. Standby: 200KW/250KVA. Prime: 180KW/225KVA

Technical Data 280KW / 350KVA 256KW / 320KVA. Bargh Afshan Alborz. Standby Power(50Hz) Prime Power(50Hz) General Features:

PGDLS / / / / / / / / /

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Voltage adjusting range % Voltage stabilization time(100% load sudden reduce) 3. Voltage fluctuation rate: Frequency volatility ±0.

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

23 KW / 29 KVA POWERED by

GMS800C/ Features:

PGDLS / / / / / / / / /

300 KW / 375 KVA POWERED by

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Diesel Generating Set. Generator Ratings

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

APD-ULJ250. Standby Power

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

1800 KW / 2250 KVA POWERED by

PGKT / / / / / / / / / / / /

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

APD-NG400. NG Standby Power

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Diesel generator set QSX15 series engine

DW Series Generator. Specification BV-DW145

Powered by Cummins Model:YN-95C

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

Prime Ratings (KW/KVA) 400/ / / /910

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

TPD2250H6.3 TECHNICAL DATA

28 KW / 28 KVA POWERED by

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

2000 KW / 2500 KVA POWERED by

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

500 KW / 625 KVA POWERED by

Voltage kva kw kva kw Amp 400/ ,00 88,00 100,00 80,00 144,00

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

130 KW / 165 KVA POWERED by

70 KW / 90 KVA POWERED by

Rental Power QSB7 series engine

Diesel generator set QSK23 series engine

45 KW / 55 KVA POWERED by

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

DIESEL GENERATOR SET MTU 18V2000 DS1400

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

CUKUROVA GENERATOR SYSTEMS

Annex A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 400V (750KVA) DIESEL

64 KW / 80 KVA POWERED by

1000 KW / 1250 KVA POWERED by

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

KH275. Frequency (Hz) Optional control panel POWER. Voltage

KV550C2. Frequency (Hz) Voltage (V) Standard control panel Optional control panel Optional control panel Optional control panel POWER

Transcription:

Powered by Cummins K38 Series Genset Standby Power :820KW Basic Characteristics of Diesel Generator Set All series powered by the Cummins engine, modern technique, dependable performance,high combustion efficiency and low fuel consumption, long time continuous running, long working life, and Easy to maintain. Conform to the standard of ISO3046. All series adopt alternator of Stamford / Marathon/ Faraday/Engga; Excellent excitation characteristics, Ensure that the genset can withstand high power load moment, small Voltage fluctuation, quickly recover. Conform to the standard of GB755,BS5000, IEC34-1,CSA22.2,AS2359. Controller System All series use automatic Powertec GC6110 as controller, Integrating digital, intelligent, network technology,use for a single diesel generator set automation and monitoring system,implement a automatic starting/stopping,the data measured, Alarm protection function of the genset. Option: DeapSea/Comap. Radiator Standard 40 ambient temperature online radiator, Closed water circulation cooling system, ensure the rated power output of under high temperature environment. Steel welding base, inbuilt shock absorber Inbuilt shock absorber, perfect shock absorption The performance parameters of the diesel generator set 230/400VAC,50HZ 0.8PF Three phase four wire output (Electronic speed) Frequency drop 3% The steady state frequency 0.5% Voltage modulation 0.3% The steady state voltage deviation ±1% The transient frequency deviation +10% -7% The transient voltage deviation +20% Frequency recovery time 3S -15% voltage recovery time 1S(voltage ±3%) THF <3 TIF <50 Conform to the standard of NEMA MG1-22.43 performance, Easy installation and transport No need to install shock pad on the connection of base foundation and fixed. www.grupotecnolife.com Page 1 of 5 PGS: PCK500-1000_09/2015

Equipment Instruction Performance Parameters Model:Cummins engine K38 series Construction : Replaceable wet type cylinder block, well heat Dissipation, easy for change, high universality of parts, high Series, easy for maintenance, cylinder block and cylinder head Adopt in-built pressure lubricating oil, compact constructure, low failure rate. Starting system:24vdc starter 35A alternator Intake and exhaust: High efficiency Holset waste gas supercharger improved burning, pressure type pulse exhaust pipe can take full advantage of exhaust energy, enhance engine efficiency, air to air cooling guarantee fuel economy and better discharge. Fuel system: Cummins patented technology PT fuel system, optimize burning, upsurge power, STC distribution system ensure perfect burning. Adopt low voltage oil supply system, deploy fuel one way loop,safe and reliable. Filter system: Dry core air filter with intake resistance indicator. Rotate Paper-based full flow and bypass oil filter. Rotate anti-corrosion water filter. Performance Parameters Type: Stamford / Marathon/ Faraday/Engga Brushless, 4 pole rotating magnetic field, single bearing, with protective cover. H class insulation Standard IP23 grade Cooling system AC exciter, rotate rectifying unit Stator winding after dip treating, Surface override epoxy insulation varnish Rotor and exciter get treatment of high temperature insulating resin, will be more applicable for severe environment. Rotor dynamic balancing accord with standard BS5625,class 2.5. Advanced lubricating grease seal long time bearing. Supplied Accessories Silencer bellows exhaust bend Battery connect wire Files of original factory of engine and alternato Generator set manual book, certificate of conformity Optional Items Silent/trailer type genset Oil water separator Heat exchanger water tower cooling system Low water level, low fuel oil warning function Genset environmental protection Mains supply monitoring automatic control system Storage fuel tank BAC 06 battery charger www.grupotecnolife.com Page 2 of 5 PGS: PCK500-1000_09/2015

Intelligent Control System Standard Detection Function 3 phases voltage Ua,Ub,Uc 3 phases current La,Lb,Lc Frequency F1 Active power PA Apparent power PR Power factor PF Coolant temperature WT / display Oil pressure OP kpa/psi/bar display Speed RPM Battery voltage V HC timer records 99999 hours The maximum cumulative times of starting can reach 999999 Standard Protection Function Genset Protection Programmable alarm and status input Emergency stop Protection Stop for over speed Alarm for low/high battery voltage Alarm/Stop for low oil pressure Alarm for shortage of battery Alarm/Stop for high coolant temperature Stop for failure to start/jigger Indication for sensor fault Protection Stop for over high/low voltage Stop for over frequency Alarm/stop for over current Stop for low frequency Stop for loss of voltage detection signal Control System Components Control switch manual/auto/stop/start Screen menu selection button Setting button Emergency stop button Fault status indicators Digital display Communication Interface (Optional Function) Adopt international standard MODBUS communication protocol with error detection as well as RS232/ RS485 (RS485 is opto-isolated type) Realize functions including remote control, telemetry and telesignalling, which are facilitate to monitor gensets. www.grupotecnolife.com Page 3 of 5 PGS: PCK500-1000_09/2015

Data sheet of Genset Model PCK830S-60 Genset Battery Prime Rating (kw) 750 Standby Rating (kw) 820 Prime current(a) 1353 Frequency(hz) 60 Model KTA38-G2B Gross output-prime (kw) 830 Gross output-standby (kw) 920 Bore * stroke 159*159 Cylinders and build 12,V type Cubic capacity(l) 37.8 Compression Ratio 14.5:1 Intake way Turbo charging, jacket water after cooled and air to air after cooled Max intake resistance (kpa) 6.23 Air intake (m 3 /h) 4928 Max exhaust back pressure (kpa) 10 Exhaust gas flow(m 3 /h) 13244 Exhaust temp( ) 502 Cooling way Radiator and Fan Fan exhaust flow (m 3 /min) 2169 Coolant capacity (L) 252 Highest water temperature( ) 104 Minimum air opening to room (m 2 ) 5.8/4.5 Thermostat range ( ) 82-93 Max oil temperature ( ) 121 Lubrication system oil capacity (L) 135 Fuel consumption(l/h) 205 Standard Governor/Class Electronic Prime voltage(v) 416/240 Prime power factor 0.8 Exciter Brush-less, Self-exciter Max voltage regulation ±1% phase 3 Protection class IP21 Insulation class H 2X200AH Rated capacity (AH) 12V (optional) www.grupotecnolife.com Page 4 of 5 PGS: PCK500-1000_09/2015

and Weight Genset Model Wet Weight (kg) Net Weight (kg) A B C PCK830S-60 7034 6371 4538 1805 2467 www.grupotecnolife.com Page 5 of 5 PGS: PCK500-1000_09/2015