smissline Description

MVC4MEDIUM VOLTAGESOLIDSTATESOFTSTARTER


SECTION MOTOR CONTROL

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

team master medium voltage solid state starters

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

ABB Softstarter Benefits Charnchanok Thongprad

Features and Benefits. Control Features

Open & enclosed. Spec Tech Industrial 203 Vest Ave. Valley Park, MO Phone: 888 SPECTECH. Reduced voltage starters. Overload relay protection

HVW701 HVAC Drive with By-Pass

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Wire size

Technical data OT16E3 OT160E3 UL & CSA

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

SSW07. Soft Starters. Applications. Standard Features

RVS-DN Digital Soft Starter A, V Instruction Manual

SSW03 Soft Starter APG2009.indd 69 5/26/09 8:55 AM

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

Contacts NEMA A600, 10A thermal. Contacts NEMA Q600, 5A thermal. Low energy contacts gold plated. Minimum PUSHBUTTON

MCD 200 Series Soft Starters

Individual & fixed bank capacitors

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

CUSTOMIZED OPTIONS FOR 1-WEEK DELIVERY

AuCom - Soft Starters

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

USERS MANUAL MCD REMOTE OPERATOR

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Application Description

825-P Modular Protection System for motors Specification Guide

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

SECTION VARIABLE FREQUENCY DRIVE UNITS

Softstarters Softstarters

Hp V AC Current Rating [A] 230V AC 60 Hz

Reduced Voltage Starters Section 2

EPS-ECONOMY PUMP STARTER

Reduced Voltage Starters

Basics of Medium Voltage Motor Control Starter Power Components & Starter Types

HPS2DB Serial Softstarter Operation Manual

Table of Contents. Chapter 1: Introduction 1.1 General Description 1. Chapter 2 - Installation 2.1 Receiving and Unpacking.. 5

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

RVS-AX Instruction Manual

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Motors Automation Energy Transmission & Distribution Coatings. GPH2 Combination Soft Starters

SECTION MOTOR STARTERS (AMPGARD) MEDIUM VOLTAGE

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Submittal Data Information

System pro M compact Miniature Circuit Br eakers Description Features

SECTION 16483C ADJUSTABLE FREQUENCY DRIVE - CLEAN POWER (CPX)

Application example of a motor controlled by MCD100 and protected by a circuit breaker

ROBICON W120 enclosed drive

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

The Enclosed Altistart 22 Soft Start/Soft Stop Motor Controller

INSTRUCTION MANUAL. JKSSS Plus Series. Medium Voltage Solid State Starter INSTALLATION OPERATION - MAINTENANCE. Issued: 11/12 Firmware Version 7.

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Soft Starters... Type S801+, Soft Starters. Type S801+, Soft Starters

Variable speed drive or soft starter?

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

TRIPS AND FAULT FINDING

ISA-HD MEDIUM VOLTAGE SOFT STARTERS. Digital medium voltage soft starters

Intelligent Low Voltage Solid State Motor Control Products. with next generation MX 2 /MX 3 technology. Low Voltage Solid State Starters

MaxPak Plus Analog DC V S Drive

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation

MOTOR CONTROL IS OUR NATURE PRODUCT GUIDE

Power Switching Devices

SECTION MOTOR CONTROLLERS

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

Softstarters Type PSS. Softstarters. General information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

Phone: Fax: Web:

Motor Starters. Reduced Voltage. Reduced Voltage Motor Starters Contents

SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

Softstarters Type PSR. Softstarters

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

ABB Softstarters The new PSS line from 3A to 515A

Cutler-Hammer. Instructions for Installation, Operation, and Maintenance of the AMPGARD Reduced Voltage Soft Starter

Product Description. Application Description

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

RVS-DN Instruction Manual

CWM_N NEMA Rated Contactors

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Features and Benefits

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

HPV 100 Hydraulic Elevator Soft-Starter Technical Manual

Transcription:

Medium voltage 2300 13,800V 1 Description Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum contactor sized for across-the-line motor starting (optional on "soft start only" models) Bi-metallic thermal overload provides backup motor protection when operating in emergency bypass mode (optional on "soft start only" models) 120V fused control power transformer standard in line start section (optional on "soft start only" models) Digital controller provides solid state overload and numerous protective features for both the motor and the soft starter Fiber optic fi ring circuit for superior electrical noise isolation Programmable keypad with LCD and status LEDs for easy setup and operation Bypass vacuum contactor sized for across-the-line (emergency) motor starting is standard on all models to guarantee cool operation in all environments and extend unit life Heavy duty SCR stack assemblies with ring transformer isolated circuit for reliable, hard-fi ring gate pulse Isolated low voltage compartment provides maximum protection for operating personnel Mechanically interlocked medium voltage compartment UL File # E175732 2 1 Consult factory for higher voltages. 2 For softstarters rated 410V, 400A and below. Low Voltage Products & Systems.49 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03 Spec Tech Industrial 203 Vest Ave. Valley Park, MO 3088 Phone: 888 SPECTECH Fax: 3 537-1405 www.spectechind.com

General information Key construction features Fused disconnect switch with blown fuse indicators and door safety interlocks rated for load break/fault make with automatic grounding arm Inline isolation vacuum contactor 2 sized for across-the-line motor starting (optional on "soft start only" models) Bi-metallic thermal overload provides backup motor protection when operating in emergency bypass mode (optional on "soft start only" models) 120V fused control power transformer standard in line start section (optional on "soft start only" models) Digital controller provides solid state overload and numerous protective features for both the motor and the soft starter Programmable keypad with LCD and status LEDs for easy setup and operation Bypass vacuum contactor 2 standard on all models to guarantee cool operation in all environments and extend unit life Heavy duty SCR stack assemblies with ring transformer isolated circuit for reliable, hard-fi ring gate pulse Isolated low voltage compartment provides maximum protection for operating personnel Mechanically interlocked medium voltage compartment Heavy duty SCR power assemblies Rated for 500 percent overload for 0 seconds Field-proven design in use since 1975 Fiber optics gate-fi ring circuit using ring transformer isolation design for superior noise immunity Industrial real world packaging Load break/fault make disconnect switch with door safety interlocking mechanism Isolated, noise-immune low voltage control compartment NEMA 12 enclosure with bypass vacuum contactor included as standard 12 Extra wiring space for MV cables for easy installation Custom engineered systems Available in special enclosures and lineups Numerous control component options including: Reversing contactors Motor protection relays Customer specifi ed devices Horizontal and custom bus interconnects Various motor confi gurations including synchronous, wound rotor and two speed Digital microprocessor control Full featured for fl exibility, including dual ramp and programmable custom start curves LCD status/alarm display and builtin programing keypad Serial communications port standard: RS485 with Modbus RTU protocol or RS232 with Windows interface In-depth motor and system protection monitors Monitors 18 separate parameters and maintains a nonvolatile fault memory 1 13.8 kv softstarters are rated NEMA 1. 2 13.8 kv, 00A softstarters use circuit breakers for isolation and bypass functions..50 Low Voltage Products & Systems AC 1000-11/03 ABB Inc. 888-385-1221 www.abb-control.com

Ratings 1 Soft start with line start section Optional soft start only 2 Volts Max. Nominal Catalog List Catalog List amps max. HP number price number price 200 800 SSM-23200-E-S SSM-23200-E 2300 400 1500 SSM-23400-E-S 3 SSM-23400-E 3 00 2500 SSM-2300-E-S SSM-2300-E 200 1000 SSM-33200-E-S SSM-33200-E 3300 400 1800 SSM-33400-E-S 3 SSM-33400-E 3 00 3000 SSM-3300-E-S SSM-3300-E 200 1250 SSM-41200-E-S SSM-41200-E 410 400 2500 SSM-41400-E-S 3 SSM-41400-E 3 00 5000 SSM-4100-E-S SSM-4100-E 00/ 900 13,800 200 2500 SSM-200-E-S SSM-200-E 400 5000 SSM-400-E-S 3 SSM-400-E 3 00 7500 SSM-00-E-S SSM-00-E 300 7500 SSM-138300-E-S 3 SSM-138300-E 00 15,000 SSM-13800-E-S SSM-13800-E 3 Custom line-up SSM-41200-E-S Catalog number explanation SSM - 23 200 - E - S Softstarter SSM medium voltage Voltage 23 = 2300V 33 = 3300V 41 = 410V = 00/900V 138 =13,800V S = Switchgear line start panel E = NEMA 12 enclosure 45 Amperage 200 = 200A 400 = 400A 00 = 00A 1 Contact factory for higher horsepower and voltage requirements. 2 Must be used with customer supplied line start panel. 3 Consult factory. 4 Consult factory for other enclosure types. 5 13.8 kv softstarters are rated NEMA 1. Low Voltage Products & Systems Discount schedule SSME.51 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03

Technical data Type of load Three phase medium voltage AC induction motors AC supply voltage 2300, 3300, 410, 00/900, 13,800 VAC +10% to -10% 50/0 Hz line voltages HP ratings 1 Up to 15,000 HP @ 13,800V (00 Amps max) Overload rating 500% 0 Seconds Power circuit Series strings of SCR power modules (2,4 or matched pairs of SCRs per phase depending on voltage rating) SCR peak inverse voltage Amps Line voltage PIV rating 2300 V 500 200 to 3300 V 13,000 400 410 V 13,000 00/900 V 19,500 11-14 kv 39,000 2300 V 7000 3300 V 14,000 00 410 V 14,000 00/900 V 21,000 11-14 kv 39,000 Transient voltage protection dv/dt circuits (1 per SCR power module) Vacuum bypass contactor 3 Standard on all models, line start rated Ambient operating temperature 0 to 50 C (32 F to 122 F) (Optional -20 to 50 C with heaters) Control Digital microprocessor controller with read-out in English text Alphanumeric LCD display Non-volatile memory for programming and faults Opto-isolated inputs Communications RS485 with modbus RTU protocol RS232 with Windows interface Auxiliary contacts FORM C, 8 Amps @ 250V Adjustments Motor FLA Dual adjustments Two independent settings for: Initial voltage 0 100% of nominal voltage Current limit 0 00% of motor FLA Acceleration time 1 120 seconds Deceleration time 1 0 seconds Kick start 0.1 2.0 seconds, 10-100% of line voltage Under voltage trip 70 95% (adjustable trip delay) Over voltage trip 105 130% (adjustable trip delay) Under current trip 20 90% of motor FLA (adjustable trip delay) Over current trip 100-300% of motor FLA (adjustable trip delay) Allowable re-starts 0 10 (adjustable time inhibit) Motor and starter protection Electronic overload Inverse time, 75 150% of motor FLA Electronic shear pin Trips within 1 cycle of setpoint Phase loss One or more phases missing Phase sequence Phase sequency incorrect Over voltage Trips at high line setpoint Under voltage Trips at low line setpoint Stall protection Starting process is not complete Shorted SCR Internal fault detected Error connection Internal fault/motor connection Starter over-temp Heatsink over temperature Metering Current Phase A, B, C & average current Thermal data Thermal capacity of motor Power KVA, KW, KVAR, power factor, KWH Line start section Load break/fault make disconnect switch with automatic grounding arm and viewing window Fuses with blown fuse indicator In-line vacuum contactor3 Control power transformer with fused primary/secondary Packaged in common enclosure with soft start Optional "Soft Start" (requires customer supplied line start panel) Statistical data Total amount of run time since soft start was reset Amount of time it took motor to start during last period Maximum current during last start period Total number of starts since soft start was reset Event history for last 0 events Elevation 1000 m / 3300 ft. without derating (contact factory for higher elevations) Enclosure 2 NEMA 12, top and bottom entrance plates 11 gauge steel ASA #1 gray paint with lifting eyes 1 Consult factory for higher horsepower and voltage requirements. 2 13.8 kv softstarters are rated NEMA 1. 3 13.8 kv, 00A softstarters use circuit breakers for isolation and bypass functions..52 Low Voltage Products & Systems AC 1000-11/03 ABB Inc. 888-385-1221 www.abb-control.com

Approximate dimensions B C A Soft start with line start section (inches) Optional softstart only (inches) Model number A B C Model number A B C SSM-23200-E-S 92 3 30 SSM-23200-E 92 3 30 SSM-23400-E-S 92 3 30 SSM-23400-E 92 3 30 SSM-2300-E-S 92 72 30 SSM-2300-E 92 3 30 SSM-33200-E-S 92 3 30 SSM-33200-E 92 3 30 SSM-33400-E-S 92 3 30 SSM-33400-E 92 3 30 SSM-3300-E-S 92 72 30 SSM-3300-E 92 3 30 SSM-41200-E-S 92 3 30 SSM-41200-E 92 3 30 SSM-41400-E-S 92 3 30 SSM-41400-E 92 3 30 SSM-4100-E-S 92 72 30 SSM-4100-E 92 3 30 SSM-200-E-S 92 72 30 SSM-200-E 92 3 30 SSM-400-E-S 92 72 30 SSM-400-E 92 3 30 SSM-00-E-S 92 72 30 SSM-00-E 92 72 30 SSM-138300-E-S 92 120 44 SSM-138300-E Consult factory SSM-13800-E-S 92 84 9 SSM-13800-E Low Voltage Products & Systems.53 ABB Inc. 888-385-1221 www.abb-control.com AC 1000-11/03

Notes.54 Low Voltage Products & Systems AC 1000-11/03 ABB Inc. 888-385-1221 www.abb-control.com