Miniature Circuit Breaker

Similar documents
MINIATURE CIRCUIT BREAKER

Goldline Miniature Circuit Breakers

(Miniature Circuit Breaker)

Jtec 10kA Miniature Circuit Breaker

Perfection that Matters

01 Spectra Plus - Introduction

3 - Protection components Motor circuit-breakers

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

RESIDUAL CURRENT CIRCUIT BREAKER

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Control Circuit Protection

ATyS S - ATyS d S Remotely operated Transfer Switching Equipment from 40 to 125 A

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Miniature Circuit-Breakers (MCBs)

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

The young energy ensures more safety

DX³ RCCBs - ID 4P up to 100 A

Vistop TM isolating switches 63 to 160A

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

D509E. Manual Motor - Starters

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

NB1 Miniature Circuit Breaker

Phase + Neutral, neutral on right side

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Phase + Neutral, neutral on left side

DRX 125 Circuit breaker (not adjustable)

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

cor Long Run Experience

Selection Guide Motor Control Device Solutions

DRX 100 B/N/H Circuit breaker (not adjustable)

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

DRX 250 B/N/H Circuit breaker (not adjustable)

Protection components

For Info: Phone: Fax:

Moulded Case Circuit Breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

IEC Low Voltage General Purpose Protection

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

1489-M Circuit Breakers

DPX moulded case circuit breakers

and other modular devices for low voltage installation

Moulded case circuit breakers

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DPX Magnetic only


, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

AF40... AF96 3-pole contactors Technical data

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

TX³ RCCBs 2P up to 100 A

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Wall mounted switchgear

Miniature circuit-breaker (MCB) SH200M Series

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

R.C.B.O. SP / 1 module

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

MCCB Accessories to suit AF

COMBINATION CIRCUIT BREAKERS RCBO

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

DPX earth leakage DPX 3 -I earth leakage

DX³ 4-pole RCBO 6000 A/10 ka

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal magnetic and trip-free switches

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

Modular contactors and relays

Innovation That Leads the Change

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

Jtec 489 UL489 Branch Circuit Breaker

Manual Motor Starters. Meta-MEC

Technical Information

Industrial Contactors CTX 3 3P 185A - 800A

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Cat N 3. OVERALL DIMENSIONS

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

DPX 1600 Electronic release

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

up to 63 A (1 module per pole)

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

SWITCHGEAR. 4G cam switches

K50H004UP cam changeover switch - 4-pole A - screw mounting

SFS-UFS Single Foot Switches

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

NEW. Moulded Case Circuit Breakers New DU Series 20 A to 250 A

Transcription:

Introduction - Miniature Circuit Breaker (MCB) SALIENT FEATURES SALIENT FEATURES Standards MCBs conform to the latest standard IS 8828: 1996/IEC: 898 1995 Mid-Trip Position The Mid trip position of the knob is visible indication of fault condition. Identification of Faulty circuit becomes very easy. Energy Saving Watt loss - 40%-75% of stipulated values in IS: 1996 / IEC Pub 898 1995, making it one of the most energy efficient MCB s. Low let through energy 2 Under short circuit conditions I t (let through energy) is minimum in Goldline MCBs (Class-3 as per BS EN 60898) - ensuring longer life of contacts and reduces thermal Stresses in the distribution circuits. Safety MCBs have incorporated shrouds to prevent direct touch with live parts ensuring protection against electric shock. Perfect Connections MCBs have been provided with serrated box type terminals with saw tooth type serrations & stirrup type terminal surface on both sides. Thus it ensures perfect grip on conductors. Torque withstand capacity of terminals is more than 2 Nm.

Step mounting clip The MCB has been fitted with 2-step thermoplastic mounting clip which provides convenient mounting and removal of MCBs. CB Certification The only MCB in India under IECEE-CB scheme as per IEC: 898-1995. The CB certificate is acceptable to all member countries globally. CONSTRUCTIONAL FEATURES CONSTRUCTIONAL FEATURES Housing The housing of Goldline MCBs is made of injection moulded thermoplastic polyester (PBT) in RAL 7035 Grey colour, as per international code. This material is fire retardant, Anti tracking and non-hygroscopic. Contacts The contacts are made of Silver-inlaid copper which ensure longer life of contacts. These have low resistance resulting in low watt loss. The contacts are designed to have zero Bounce during closing operation. Operating Mechanism Goldline MCBs have quick make, quick break, trip-free mechanism. Mounting Arrangement Goldline MCBs are installed directly on 35mm DIN Rail in distribution boards / control Panels simply by snapon-fixing, hence saves time in installation or removal. Working Principle Miniature Circuit Breakers are based on thermal magnetic technology. The protection is Provided by combining a temperature sensitive device (bimetal) and a current sensitive electromagnetic device. Both components trigger the mechanism mechanically. The MCB design is based on current limiting technology. Back up Protection Goldline MCBs are capable of handling fault levels of current up to 10,000 A. However, for installations where the fault current is expected to be more than 10,000A, backup can be achieved by using Indo Asian HRC Fuse links 100A, gg type fuse link. Low Watt Loss Goldline MCBs have been designed to minimize energy loss through unique contact Configuration and reduction of hot spots. Watt loss per pole in Goldline MCB is far lower than that specified in IS 8828:1996 / IEC Pub 898-1995. Rated Current (A) Max. allowable Watt loss MCB Max. Watt Per pole as per Loss Per pole IS: 8828-1996, IEC Pub 898 (1995) Rated Current (A) Max. allowable Watt loss per pole as per IS: 8828-1996, IEC Pub 898 (1995) & IEC-60898-1, 2002 Goldline MCB Max. Watt Loss Per pole <10 3.0 1.3 10<In=16 3.5 2.5 16<In=25 4.5 2.7 25<In=32 6.0 4.0 32<In=40 7.5 4.3 40<In=50 9.0 4.5 63 13.0 7.0

APPLICATIONS B Type For protection of Resistive loads such as bulbs, heaters etc. C type For protection of Inductive loads such as motors, air conditioners etc. D type For protection of Cables and highly inductive loads which have high starting current such as transformers. Indo Kopp MCBs for DC application have all features as those of AC MCBs with following additional features making it suitable for DC circuits. FEATURES DC MCB incorporates built in permanent magnet, which directs the arc in to the arc quenching chamber. Free from nuisance tripping caused by vibrations. Clear indication of polarity by the use of stickers, + sign on incoming terminal of single pole and + symbol on first pole/ - symbol on second pole of 2 pole MCBs. Time constant > 5 ms. DC MCB with extended terminals meeting RSDO specification no. SPEC/E-12/1/04 are also available. ACCESSORIES AUXILIARY SWITCH The auxiliary switch is used for remote signalling, auxiliary supplies and other similar functions. The auxiliary switch is switched ON and OFF together with the MCB through internal linkage. This can be used in following configurations application. This is fitted on left side of the MCB. Configuration Combination of Terminals to be used 1. N.C. & N.O.E 21-22, 11-14 2. N.C. & Changover 21-22, 11-12, 14 3. N.C. & N.C. 21-22, 11-12 Technical Data Rated Voltage, Max. Rated Current Conductor Cross section Module Width : 220 V AC 110 V DC : 6 A AC / 1 A DC : up to 1 mm : 9 mm

SHUNT TRIP The shunt trip switch provides the facility of tripping MCBs from remote locations. Depending on the construction and use, this is available in two different versions as described below: 1. Shunt trip function only For tripping, the required tripping voltage is applied across the leads taken out of the Shunt trip. 2. Shunt trip with isolable neutral In this version in addition to shunt coil, the isolable neutral is provided in the same housing. The two leads are taken out for application of tripping voltage to the coil. The instant tripping voltage to the coil can be for less than 100 milliseconds preferably via push button or any other device. In case tripping voltage is continuously applied, for longer, the coil can burn. The shunt trip release is fixed on the right side of the MCB. Technical Data Rated Voltage Un Rated Frequency Break time Module Width Connecting Terminal : 24-415 VAC 24-220 VDC : 50 Hz or D.C. : <0.1 sec. : 17.5 mm. : 6 inch long flexible wires All above accessories are available factory fitted. Technical Specifications AC MCB Specifications : IS 8828: 1996, IEC Pub 898-1995 Number of Poles : 1, 1+N, 2, 3, 3+N & 4 Tripping Characteristic & Rated : B characteristics - 6A to 63A Currents (In) : C characteristics - 0.5A to 63A D characteristics - 0.5A to 63A Rated breaking capacity (Icn) : 10,000 A Energy Limiting Class : Class 3 as per BS EN 60898 Rated Voltages (Ue) Single Pole : 240 / 415 VAC / 60 VDC Multi Pole : 415 VAC / 110 VDC (When 2 poles connected in Series) Insulation Voltage (Ui) : 500V Rated Frequency : 50/60 Hz Impulse withstand voltage (Uimp) : 4 KV (1.2 / 50 u s) Impulse power frequency voltage : 2KV (50 Hz) Housing material : Polybutylene Terephthalate in RAL 7035 Grey colour Degree of Protection : IP 20 as per IS: 13947 / IEC 60529 Mounting Connecting Terminals Electrical Service Life Ambient Temperature : Quick-snap on DIN rails, 35mm : Combination box terminals on incoming and outgoing sides. Suitable for single-core, stranded and flexible conductors upto 25 Sq mm. : Min. 30,000 make/break operations : T max. : +55º C T min.: -25º C

DC MCB Specifications No. of Poles Rated Current Rated Voltage Rated short circuit breaking capacity Insulation Voltage Mounting Connecting Terminals Electrical Service Life Vibration Level : IEC-60898-2-2002/RSDO - SPEC/E-12/1/04 : Single pole, Double Pole : 0.5 to 63A : 220 V DC : at 48V DC-10kA above 48V DC & upto 130 VDC-1kA : 500V : Quick snap to mounts rails 35 mm on mounting bracket for RDSO : Combination box type terminals on both sides and also with extended terminals : 10,000 make/break operations : 3g, 50 cycles ISOLATORS Specifications : IS 13947 Part 3/IEC-60947-3, 1999 Current Ratings : 40, 63, 80,100 and 125A Rated Voltage : 240/415 V Number of Poles : SP, DP, TP & FP Utilization Category : AC23A SHUNT TRIP