Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

Similar documents
Sentry Technical. Miniature Circuit Breakers (MCBs) -s c to +400C. Standards and approvals. Description OFF. Technical specification

l Suitable for most residential, commercial and light industrial applications

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Miniature & Moulded Case

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

NB1 Miniature Circuit Breaker

MINIATURE CIRCUIT BREAKER

Paramount HRC Cartridge

Miniature Circuit-Breakers (MCBs)

Thermal-magnetic Miniature Circuit Breaker 4230-T...

(Miniature Circuit Breaker)

FUSES. Safety through quality

Power systems Protection course

Electronic circuit breaker EBU10-T

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Fuses still the best form of overload protection

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

All round protection guaranteed

1492-CB 1492-GH 1492-GS

Control Circuit Protection

Technical Section: Miniature Circuit Breakers

Phase + Neutral, neutral on right side

Low Voltage A GE Power Controls Company. General catalogue

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

UMBW-UL489 and UL1077 Listed

High-voltage high-breaking capacity VV fuse-links

Miniature Circuit Breaker

Phase + Neutral, neutral on left side

Bulletin 1489 Circuit Breakers. Selection Guide

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

R.C.B.O. SP / 1 module

Effective discrimination of protective devices

FUSE: SAFE & RELIABLE

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

3.2. Current Limiting Fuses. Contents

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

and other modular devices for low voltage installation

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Modular contactors and relays

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

TECHNICAL SPECIFICATION

DX³ RCBO 6000A Phase + Neutral, neutral on left

MAGNETIC MOTOR STARTERS

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

3 - Protection components Motor circuit-breakers

AF series contactors (9 2650)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Btdin RCBO 6000A up to 63A (2P)

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

(1,5 modules per pole)

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

DX³ 4-pole RCBO 6000 A/10 ka

Grosvenor Plus 138 decorative Solid brass highly polished, with rope-edge detail Pre-treated heat-cured powder lacquer finish Total safety

RX 3 M.C.B A up to 63 A

1489-M Circuit Breakers

Miniature circuit breaker Application guide

QUALITY ASSURANCE & DOCUMENTATION

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Selective main circuit breakers S 750 series Technical Data

RX 3 M.C.B A up to 63 A

Jtec 10kA Miniature Circuit Breaker

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

Bussmann series NH catalogue. Leadership in circuit protection

Technical data. Miniature Circuit Breakers. System pro M. System pro M

Air-insulated switchgear UniGear type ZS1

DX³ RCBO 6000A Phase + Neutral, neutral on right

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

Self-protected Combination Starters System PKZ 2-SP

ACS motor protection circuit breakers KT 7 Introduction

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

AF series contactors (9 2650)

Thermal-magnetic Miniature Circuit Breaker 4230-T...

ECET Distribution System Protection. Overcurrent Protection

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

A Special Note To Our Customers

Low Voltage Industrial Type T Fuse Links

S200 UL 489 Series. Miniature Circuit Breakers. Description. Features

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Shared Learning. SL027/18 Selection of Suitable Circuit Protection. 18-Jun-18 / 1

Miniature Circuit-Breakers (MCBs)

Motor & System Protection PKZ2

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

Motor Protection Circuit Breakers 3VU13 and 3VU16

FX Full-Range Current-Limiting Fuse

Jtec 489 UL489 Branch Circuit Breaker

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

ELECTRICAL INSTALLER THEORY EXAMINATION 21 June 2014 QUESTION AND ANSWER BOOKLET

High-voltage high-breaking capacity VV fuse-links

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

SX Full-Range Current-Limiting Fuse. Power & High Voltage Elastimold & Hi-Tech Fuse Products

Manual motor starters Overview and benefits

Fuseology. Dual-Element, Time-Delay Fuse Operation

POWER CAPACITORS. Cylindrical capacitor standard duty

MESG 12 / 17.5 / 24 / 36 KV

Transcription:

543 technical hotline +44 ()1268 56372 Standards and approvals Sentry MCBs are designed to fully comply with the relevant requirements of BS EN 6898: 23. They all feature positive contact status indication in accordance with the 17th Edition IEE Wiring Regulations (537.2.2.1 and 537.3.2.2). Technical specification Electrical Voltage rating: 23V/4V a.c. Operating frequency: 5Hz Rated short circuit capacity Icn: Service short circuit capacity Ics: When backed up by a BS 1361, 1A fuse, then the breaking capacity of the MCB is increased to 16,A. Energy limiting class: 3 Physical Ambient operating temperature: 5 C to +4 C Calibration temperature: +3 C IP rating: Front face IP4X, screw IP2X Terminal capacity: 35mm 2 Tightening torque: 3Nm Max. Max. installation altitude: 2 metres OFF Description ON Sentry MCBs are of the thermo-magnetic, current limiting type and are available with either Type B or Type C operating characteristics. The operating dolly may be locked in either the ON or OFF position without affecting the ability of the trip mechanism to operate. The contacts themselves are manufactured from carefully chosen materials, selected specifically for their low electrical resistance and low propensity to weld under fault conditions. Positive contact status indication When the green indicator is visible, then a contact gap of 4mm has been achieved. Sentry MCBs may therefore be used as single pole isolating switches where appropriate. Terminals The Sentry MCB features tunnel terminals of 35mm 2 capacity on all ratings. Each terminal has a protective shutter to prevent cable being installed incorrectly. The terminal screws are touch proof to IP2X, captive and feature combination heads. Modes of operation The mechanism of the Sentry MCB has been carefully designed and engineered using thermal and magnetic elements to detect over currents due to both overload and fault currents. The MCB will operate and interrupt the supply to prevent damage to the installation. The thermal component is a carefully calibrated, thermally operated bi-metal element. Larger overloads and fault current situations are dealt with using the magnetic tripping mode of the MCB. This acts very quickly, overriding the thermal operation. BS EN 6898 requires the tripping to occur within 1 milliseconds and the design of the Sentry MCB allows fault currents of up to (M6) to be safely interrupted well within this time scale.

544 Sentry Technical www.mkelectric.co.uk Description (continued) Operating characteristics TYPE B The magnetic operating limits are between 3 and 5 times the current rating of the MCB. Under these conditions the mechanism of a 1A MCB will operate between and 5A in an overcurrent situation. TYPE C In the case of Type C MCBs, the magnetic operating limits are between 5 and 1 times the current rating of the MCB. Under these conditions the mechanism of a 1A MCB will operate between 5A and 1A in an over current situation. Type C devices are capable of supplying the majority of inductive and capacitive loads such as motors, transformers and tungsten or fluorescent lighting. Time/Current and Energy let through characteristics of Sentry MCBs are shown graphically on the Time current characteristics chart (See separate document). TYPE D The Type D MCB is suitable for applications involving equipment generating very high inrush currents, e.g. x-ray equipment, trans mitters and computer power supplies. The magnetic operating limits are between 1 and 5 times the current rating of the MCB. (For Modular Combi use only) Rating specification Type B Single pole Rating 593s 596s 591s 1A 5916s Features l Meet BS EN and IEE Wiring Regulation requirements l Trip-free mechanism l Positive contact status indicator l Tunnel type, touch-proof, captive terminals l Generous terminal capacity l Can be used as single pole isolating switch l Protective shutter 592s 5925s 5932s 594s 5945s 595s Type C Single pole 873s 876s 871s 8716s 872s 8725s 8732s 874s 875s 2A 25A 4A 5A Rating 1A 2A 25A 4A 5A Installation Selection of the most suitable MCB should take into account the following considerations: 1. Operating voltage and frequencies It is possible to use the Sentry MCB on other voltages than 23/4V a.c. 5Hz, but it should be noted that this takes the MCB outside the scope of BS EN 6898. 2. Type of load RESISTIVE No derating is required in the case of resistive loads. INDUCTIVE In the case of inductive loads from direct-on-line motors, the surge on energisation can produce up to 5 times full load current, which may be present for several seconds. It is therefore recommended that Type C MCBs are used for such circuits. When using assisted start motors, the usually quoted figures are 2.5 times the full load current, for periods generally longer than those for direct-on-line starters. It is thus important to establish the degree of inrush current in order to select a suitable MCB. In all instances, reference should be made to both the motor manufacturer s curves and MK s circuit breaker curves in order to select the compatible miniature circuit breaker. CAPACITIVE Surges on energisation, for example with dis charge lighting, may well reach 25 times the rated current of the device, but only for very short duration. Type B devices will often be adequate, but for more specialised circuits, a Type C may be required. The lighting fitting manufacturer s recommendations should be observed.

545 technical hotline +44 ()1268 56372 3. Fault breaking capacity All Sentry MCBs have a short circuit breaking capacity of 6,A (M6). For applications where the prospective fault current is in excess of this, a BS 1361, 1A (maximum) fuse should be used upstream of the MCB to provide a system breaking capacity of 16,A (in accordance with BS EN 6439-3). 4. Discrimination A Sentry MCB consumer unit will normally be supplied via an HRC fuse. The HRC in such instances will be the major device and remain unaffected by any fault current which causes the MCB to operate. The level of fault current up to which this can be assured is determined by comparing the I 2 t characteristics of the two devices. Discrimi nation will theoretically occur up to the level at which the value of the total operating I 2 t of the MCB is below the minimum pre-arcing I 2 t of the fuse, although in practice, discrimination will be achieved at higher levels than this. 5. Cable protection The current carrying capacity of the cable should always exceed the current rating of the MCB to prevent damage. However, should this not be the case, a further calculation may show that the MCB can still interrupt the current in a sufficiently short time to prevent overheating of the cable insulation. Although this will prevent mechanical damage to the cables, further overload protection should be provided by a separate device, e.g. a motor overload relay. In case of doubt please contact the MK Tech nical Sales and Service Department. Dimensions (mm) 17.5 43.7 83 ON SENTRY 61 6.8 66

546 Sentry Technical www.mkelectric.co.uk Tripping Characteristics Curve Limit specified in BS EN 6898 1: 23 In: Rated Current B TYPE: to 5A C TYPE: to 5A Reference calbi. temp. 3 o C Lower Limit as per Standard Upper Limit as per Standard 1, 1, 5 5 35 35 1 1 1 IN > 1 IN > IN > IN > Time in Seconds 1 Time in Seconds 1 1 1 B-TYPE C-TYPE.1.1.1 1 1.13 1.45 2 2.55 3 5 1 2.1 1 1.13 1.45 2 2.55 3 5 1 2 Multiple of Rated Current B-TYPE Multiple of Rated Current C-TYPE

547 technical hotline +44 ()1268 56372 I 2 t curves 16 B Type -1A 1A 2 C Type -1A 1A 14 12 1 8 6 4 2 18 16 14 12 1 8 6 4 2 5A 15A 6KA 5A 15A 6KA B Type - 2A C Type -2A 2A 25 25 2 2 15 1 15 1 5 5 5A 15A 6KA 5A 15A 6KA 1 B Type 4A- 4A 12 C Type - 4A 9 8 1 7 8 6 5 4 3 6 4 2 2 1 5A 15A 6KA 5A 15A 6KA